← All vessels
M. S. SHAHAN II
Passenger (Inspected) · Passenger Ship class · Built 1990s · USCG Northeast District (CGD-NE) · Other hulls named M. S. SHAHAN II
M. S. SHAHAN II is a 1990 passenger vessel (inspected). The Coast Guard has recorded 104 inspections since 1990, most recently in May 2026, along with 106 deficiencies and 10 casualty investigations between 2005 and 2024.
Records from 1990 to 2026. Most recent: inspection, 21 May 2026.
- Built
- 1990
- Last inspected
- 21 May 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Inspections
- 104
- Deficiencies
- 106 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 10 investigations · 2005–2024
Identity
967696
WDD7097
353333
Flag
UNITED STATES
367181880
Maury page id
psix-353333
Inspections, by type
…with no type recorded19
Years with a record
35 calendar years (1990–2026)
The 104 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)103.0 ft × 25.1 ft × 9.5 ft
Registered tonnagegross 94 / net 64
ITC dimensions (L × B × D)103.0 ft × 25.1 ft × 9.5 ft
ITC tonnagegross 190 / net 71
BuilderGULF CRAFT INC · PATTERSON, LA, UNITED STATES · built 1990
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portORIENT, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 14 May 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it71 - Convention (Subpart B), Net Ton
64 - Regulatory (Subpart C or D), Net Ton
190 - Convention (Subpart B), Gross Ton
94 - Regulatory (Subpart C or D), Gross Ton
64 - Regulatory (Subpart C or D), Net Ton
190 - Convention (Subpart B), Gross Ton
94 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDD7097MMSI 367181880 · active · voluntarily equipped · granted 14 April 2017, expires 21 April 2027
WCX6063MMSI 366736260 · expired · compulsorily equipped · granted 14 July 1997, cancelled 15 September 2007
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 104
21 May 2026
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8377994
30 December 2025
In-Service Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8282538
5 August 2025
COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8178550
15 April 2025
Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8103394
19 December 2024
Internal Structural Exam · Drydock Extension
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8046760
5 June 2024
Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7926322
9 January 2024
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7847546
6 January 2024
Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7847218
3 May 2023
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7662777
19 December 2022
Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7606249
13 April 2022
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7430244
5 November 2021
Annual Inspection · Administrative Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7345837
8 April 2021
Deficiency Check · Deadweight Survey · Plan Review "T" Boat
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7166228
29 January 2021
Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7129117
21 October 2020
Internal Structural Exam · Administrative Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7081818
2 July 2020
COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6984669
28 March 2019
Administrative Inspection · Internal Structural Exam · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6650690
6 February 2019
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6682940
27 September 2018
Deficiency Check · Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6539948
28 August 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6525605
23 March 2018
Administrative Inspection · Internal Structural Exam · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6377361
29 May 2017
Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6137400
5 April 2017
Annual Inspection · Drydock Extension · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6119284
15 September 2016
Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6002251
21 June 2016
Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5914200
9 May 2016
Deficiency Check · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5872383
20 April 2016
Annual Inspection · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5857780
21 July 2015
Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5191575
12 June 2014
Annual Inspection · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4887141
12 June 2014
DAPI Audit
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4887159
13 May 2014
Examination of Repairs · Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4859635
19 June 2012
Annual Inspection · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4348732
30 January 2012
Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4234486
24 January 2012
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4268848
22 October 2010
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3891738
27 July 2009
Damage Survey
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3547756
24 July 2009
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3548765
20 June 2008
Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3247725
6 May 2008
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3202602
14 February 2008
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3147945
18 December 2007
Examination of Repairs · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3114392
12 June 2007
Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2959085
30 May 2007
Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2954068
12 April 2007
Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2906716
27 February 2007
Hull Examination · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2875315
28 September 2006
Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2788912
12 September 2006
Internal Structural Exam · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2776495
15 June 2006
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2686976
3 January 2006
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2561363
1 November 2005
Damage Survey
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2526089
24 October 2005
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2557586
19 July 2005
COI Inspection · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2432136
13 April 2005
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2348228
4 February 2005
Construction Oversight
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2286579
18 November 2004
Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2243560
10 November 2004
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2239783
30 July 2004
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2150625
17 February 2004
Examination of Repairs
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2005966
12 December 2003
Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1965263
19 November 2003
Annual Inspection · Internal Structural Exam
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1951698
24 October 2003
Uninspected Other
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1935190
23 September 2003
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2159669
4 February 2003
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1741261
4 February 2003
Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1742501
16 January 2003
Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1731567
19 December 2002
Internal Structural Exam · Annual Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1721518
12 September 2002
Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1674672
16 August 2002
In-Service Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1663452
16 August 2002
In-Service Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1672054
26 June 2002
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1635599
11 September 2001
Hull Examination · Re-Inspection · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1444607
9 January 2001
Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1056509
25 August 2000
Administrative
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 821921
2 August 2000
Deficiency Check · COI Inspection · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1384523
15 March 2000
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 131807
14 January 2000
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1467
24 August 1999
Re-Inspection · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1395274
23 July 1999
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1427683
28 July 1998
MARPOL Annex V Examination · Re-Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1122758
29 January 1998
Plan Review "T" Boat
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 805645
13 August 1997
Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1120957
12 June 1997
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1115983
6 June 1997
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 774469
3 June 1997
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1439887
26 January 1996
Damage Survey
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 882017
24 January 1996
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 882590
23 January 1996
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 148025
20 November 1995
COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 879421
8 November 1994
COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1147458
13 October 1994
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1359936
2 August 1994
Excursion Permit
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 869658
30 November 1993
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 855157
24 September 1993
Excursion Permit
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1154737
31 May 1993
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1154928
27 April 1993
Excursion Permit
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 837557
1 December 1992
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 827351
19 October 1992
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1267881
28 August 1992
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 952682
13 August 1992
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1264305
16 July 1992
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1263963
10 March 1992
Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 949988
5 November 1991
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1249987
28 September 1991
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 228732
28 September 1990
Hull Examination · Initial Certification · Initial Construction-Excluding Oversight · Inclining Experiment
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1239089
Deficiency record · 106
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 5 June 2024
Resolved
Inspection of all accessible parts of the exterior and interior of the hull, watertight bulkheads and weather decks are to be checked. Damaged weld was found on the weather deck in vicinity of aft starboard rub rail, affecting the watertight integrity of the ER space.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 June 2024
Resolved
Number of life jackets stowed inside each storage location must be marked in clearly identifiable letters and numers, at least 2 inches high. The label that states the number of life jackets was missing.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 13 April 2022
Resolved
Make repairs to machine space bilge suction and prove proper operation.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 November 2021
Resolved
Provide MSC with an updated drawing that addresses the comments listed in MSC letter E2-2103244
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 5 November 2021
Resolved
A loop for the engine room CO2 fixed system had excessive wear and required replacing.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 November 2021
Resolved
Life jacket stowage at the bow area required labeling.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 November 2021
Resolved
Repairs or alterations to machinery or equipment that effect the safety of the vessel must not be made without the approval of the OCMI. Vessel repowered. Provide MSC approval letter for reference (a) through (d) in MSC Letter Serial: E2-2103244 dated October 25, 2021.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 9 September 2021
Resolved
If during the inspection of a vessel, the vessel is found not to conform to the requirements of the regulations the MI will point out deficiency to Representative. Crack on main deck port side IWO engine room/house corner discovered during E/R inspection. Make repairs to the satisfaction of attending MI.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 8 April 2021
Resolved
If during the inspection of a vessel, the vessel is found not to conform to the requirements of the regulations the MI will point out deficiency to Representative. Crack on main deck stbd side IWO engine room discovered during inspection of port side. Make repairs to the satisfaction of attending MI.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 29 January 2021
Resolved
Repairs or alterations that affect the safety of the vessel include, but are not limited to: replacement and repairs to steering. OCMI may require an inspection and testing whenever a repair is undertaken. Pitting found on outboard fwd portion of both rudders. Make repairs to the satisfaction of attending Marine Inspector (MI).
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 29 January 2021
Resolved
Repairs or alterations that affect the safety of the vessel include, but are not limited to: replacement and repairs to structural members. Foundation brackets of MSD transfer tank have cracks. Make repairs to the satisfaction of attending MI.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 29 January 2021
Resolved
Repairs or alterations that affect the safety of the vessel include, but are not limited to: replacement and repairs to structural members. Repair 04 cracked welds found on STBD bow bulwarks.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 29 January 2021
Resolved
Repairs or alterations that affect the safety of the vessel include, but are not limited to: replacement and repairs to structural members. Port aft corner of bulwarks has damage. Make repairs to the satisfaction of attending MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 September 2018
Resolved
Properly repair/replace the leaky seal and worn coupler on the bow thruster
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 September 2018
Resolved
Remove all oil form the bilges in the forepeak space
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 27 September 2018
Resolved
Properly repair the deck fitting or remove for the phone wire on the port side aft
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 28 August 2018
Resolved
Vsl is broadcasting broadcasting incorrect Name and greater than expected vessel length
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder Liner
Issued 15 September 2016
Resolved
Port engine overheated, bad cylinder cooling nozzel.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 15 September 2016
Resolved
Cacked propeller shaft.
Construction/Loadline › Hull › Hull Plating
Issued 20 April 2016
Resolved
Clean/inspect/repair pitting below PS battery box in transom.
Construction/Loadline › Penetrations › Pipe Flange
Issued 20 April 2016
Resolved
Seal all wiring/piping penetrations all water tight bulkheads
Engineering › Steering Gear System › Hydraulic Hose
Issued 20 April 2016
Resolved
Repair hydraulic hose STBD located in void 1 for bow thruster.
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 12 June 2014
Resolved
Replace 03 hydrostatic release units on life rafts.
Construction/Loadline › Penetrations › Weld
Issued 21 December 2007
Resolved
Port and stbd deck penetrations for midship mooring bits must be completed and hose tested.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 30 May 2007
Resolved
Repair or replace the pull handles on the main deck.
Construction/Loadline › Structures › Deck Plating
Issued 9 March 2007
Resolved
Submit for approval to the local OCMI permanent repair plan for cracked welds noted on the doubler of the 2nd stbd bit from aft at the deck line.
Engineering › Thrusters › Motor
Issued 9 March 2007
Resolved
Replace in kind bow thruster muffler located on the stbd side in lazarette for holes noted in the spark/flame arrester at bottom of unit. Temp repair of martex approved until replacement unit is delivered or due date.
Construction/Loadline › Hull › Hull Plating
Issued 12 September 2006
Resolved
Repair Crack on port quarter.
Electrical › Electric Generation Source (service) › Panelboard
Issued 19 July 2005
Resolved
Replace 1 volt meter on switchboard.
Engineering › Thrusters › Piping
Issued 19 July 2005
Resolved
Repair all union leaks on bow thruster hydraulic systems.
Fire Fighting › Ventilation Systems › Ducts
Issued 19 July 2005
Resolved
Prove proper operation of vent closures for E/R compt.
Construction/Loadline › Structures › Door
Issued 19 July 2005
Resolved
Adjust all watertight doors below deck as needed.
Electrical › Lighting (service) › Lighting Feeder
Issued 19 July 2005
Resolved
replace missing light cover in E/R vestibule.
Engineering › Pressure Vessel › Relief Valve
Issued 19 July 2005
Resolved
Conduct pressure test of new air receiver relief valve and front plug.
Operations/Management › Ballast Water Managment › Submission of Report
Issued 4 February 2005
Resolved
Provide plans for newly installed bilge system.
Documentation › Safety/Response Plans/Programs › General Arrangement Plans
Issued 4 February 2005
Resolved
Provide approved copies of submitted plans for: electrical system, Engine controls, air reciever, hot water heating plan.
Lifesaving › Inflatable Liferafts › Markings
Issued 10 November 2004
Resolved
provide life raft lauching instructions.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 10 November 2004
Resolved
Provide proper mat for switchboard.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 10 November 2004
Resolved
prove servicing of fixed CO2 system.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 10 November 2004
Resolved
Reinstall engine exhaust lagging where missing.
Engineering › Sea-water System (primary cooling) › Piping
Issued 10 November 2004
Resolved
Replace outboard P/S MDE raw water hoses.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 10 November 2004
Resolved
Prove proper operation of ground fault detection.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 10 November 2004
Resolved
Vessel was overdue for annual exam by 7 days.
Construction/Loadline › Structures
Issued 19 November 2003
Resolved
Repair all cracks, stbd fwd, bulwark at upper rail, including bits and center frams.
Construction/Loadline › Structures
Issued 19 November 2003
Resolved
Repair cracked welds port side, fwd rail
Accommodation/Occupational Safety › Occupational Safety
Issued 19 November 2003
Resolved
Repair exterior ladder starboard side, cracked weld. replace bolt on port rail. LEGACY COMPONENT DESC: Deck Rail
Accommodation/Occupational Safety › Occupational Safety
Issued 19 November 2003
Resolved
Replace/provide proper labels throughout vsl, ie; child lifejackets, forepeak shut off and fire station #2. LEGACY COMPONENT DESC: Labels
Engineering › Diesel Engine (propulsion/auxiliary-electric)
Issued 19 November 2003
Resolved
Repair exhaust leak, stbd generator. LEGACY COMPONENT DESC: Piping (exhaust)
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 19 November 2003
Resolved
Replace engine room lagging as needed LEGACY COMPONENT DESC: Piping (exhaust)
Engineering › Diesel Engine (propulsion/auxiliary-electric)
Issued 19 November 2003
Resolved
Repair fuel leak on generator return line. LEGACY COMPONENT DESC: Fuel return line
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 19 December 2002
Resolved
Prove monthly portable fire extinguishing maintenance is completed. LEGACY COMPONENT DESC: Monthly Inspection
Documentation › Certificates/Documents
Issued 19 December 2002
Resolved
Mount COI with all pages visible to passengers. LEGACY COMPONENT DESC: Certificate of Inspection
Electrical › Electrical Distribution System (service)
Issued 19 December 2002
Resolved
Remove extention cord from under the aft bridge shelf and hard wire the computer with power strip. LEGACY COMPONENT DESC: Wiring
Accommodation/Occupational Safety › Medical/First Aid
Issued 19 December 2002
Resolved
Provide asprin for the first aid kit. LEGACY COMPONENT DESC: Medicine Chest
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 19 December 2002
Resolved
Install new fixed CO2 system to the satisfaction of attending marine inspector. LEGACY COMPONENT DESC: New system
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 19 December 2002
Resolved
Replace stbd. outboard MDE stbd turbo hose to the MDE LEGACY COMPONENT DESC: Turbo hose
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 19 December 2002
Resolved
Replace the stbd inboard MDE raw water discharge hose. LEGACY COMPONENT DESC: Raw water discharge hose
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 19 December 2002
Resolved
Replace the stbd. inboard MDE gasket on the stbd inbd turbo. LEGACY COMPONENT DESC: Turbocharger
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 19 December 2002
Resolved
Make proper repairs to strb inbd MDE stbd exhaust pipe. LEGACY COMPONENT DESC: Piping (exhaust)
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 19 December 2002
Resolved
Replace stbd inbd MDE raw water discharge hose. LEGACY COMPONENT DESC: Raw water hose
Construction/Loadline › Hull
Issued 19 December 2002
Resolved
Re-seal all deck hatches over MDE's. LEGACY COMPONENT DESC: Soft patches over MDE''''s
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 19 December 2002
Resolved
Port outbd MDE outbd turbo replace hose and tighten hose clamps. LEGACY COMPONENT DESC: Turbo
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 19 December 2002
Resolved
Port outbd MDE turbo stbd side make repairs to stop oil leak. LEGACY COMPONENT DESC: Turbo
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 19 December 2002
Resolved
Replace head cover gasket on port outboard MDE LEGACY COMPONENT DESC: Cylinder Head
Electrical › Electric Generation Source (service)
Issued 19 December 2002
Resolved
Stbd generator cooling water leak in cooling system hose. LEGACY COMPONENT DESC: Water leak
Navigation › Piloting/Steering
Issued 19 December 2002
Resolved
Tighten rudder post bolts on port side. LEGACY COMPONENT DESC: Rudder post
Engineering › Compressed Air System (start air)
Issued 19 December 2002
Resolved
Prove proper operation of 2 relief valves on strb and one on the port air compressers LEGACY COMPONENT DESC: Valve
Operations/Management › Drills/Instruction
Issued 19 December 2002
Resolved
Provide written directions for bilge and fire systems. LEGACY COMPONENT DESC: Fire
Electrical › Electric Generation Source (service)
Issued 19 December 2002
Resolved
Provide proper lagging for stbd generator exhust system. LEGACY COMPONENT DESC: lagging
Electrical › Electric Generation Source (service)
Issued 19 December 2002
Resolved
Provide voltmeter for the port generator. LEGACY COMPONENT DESC: volt meter
Electrical › Electric Generation Source (service)
Issued 19 December 2002
Resolved
Make proper repairs to stbd generator exhaust leak. LEGACY COMPONENT DESC: Exhaust leak
Construction/Loadline › Hull
Issued 19 December 2002
Resolved
Make proper repair to open seam in hull, stern section aft stbd side in corner above the rub rail LEGACY COMPONENT DESC: Hull Plating
Pollution Prevention/Response
Issued 16 August 2002
Resolved
Excess of oily wast in the bilge. LEGACY COMPONENT DESC: Oil and fuel in the bilge
Engineering › Bilge Water Management System
Issued 26 June 2002
Resolved
Pump bound up. LEGACY COMPONENT DESC: Pump
Engineering › Bilge Water Management System
Issued 26 June 2002
Resolved
Provide documentation attesting that "dresser couplers" style 38 installed on bilge suction lines are acceptable for vital systems IAW sub T. LEGACY COMPONENT DESC: Piping
Construction/Loadline
Issued 2 August 2000
Resolved
Provide audible alarms for bilge high level alarm system
Construction/Loadline
Issued 2 August 2000
Resolved
Repair holes in bilge piping in way of bilge manifold
Construction/Loadline
Issued 2 August 2000
Resolved
Demonstrate satisfactory operation of bilge pumping system
Lifesaving
Issued 2 August 2000
Resolved
provide copies of August 2000 training/drill logs
Engineering
Issued 2 August 2000
Resolved
Repair port outboard MDE low water alarm
Engineering
Issued 24 August 1999
Resolved
PROVE PROPER OPERATION OF SHIP'S HEATER SAFETY DEVICES AS INSTALLED.
Engineering
Issued 24 August 1999
Resolved
EXTEND PRESSURE/TEMP DISCHARGE PIPE TO TERMINATE 1" OFF OF THE DECK.
Documentation
Issued 24 August 1999
Resolved
COMPLETE ANNUAL DAPI COMMENTS BASED UPON ANNUAL REVIEW.
Fire Fighting
Issued 24 August 1999
Resolved
PROVIDE ADDITIONAL HOSE STATIONS AS REQUIRED TO MEET 46 CFR 181.15-5 (OLD SUB T). PRIOR TO FIRE MAIN MODIFICATIONS, PROVIDE PLANS TO THE COGNIZANT OCMI FOR APPROVAL.
Fire Fighting
Issued 24 August 1999
Resolved
PROVIDE PIPE CERTIFICATION OF TYPE FOR CO2 SYSTEM PIPING.
Lifesaving
Issued 23 July 1999
Resolved
Remove oil from bilge in void 2 (MSD Void), repair leaks in hydraulic linesto bow thruster at unions and at 45 degree elbow on aft bulkhead.
Construction/Loadline
Issued 23 July 1999
Resolved
Submit plans for approval for additional high level alarm required in generator room. Upon approval install required alarm.
Lifesaving
Issued 28 July 1998
Resolved
APPLY REFLECTIVE TAPE IN EACH QUADRANT, BOTH SIDES, ON THE ORANGE RING BUOYOUTSIDE THE BRIDGE.
Documentation
Issued 28 July 1998
Resolved
PROVIDE RADIO OPERATOR'S PERMIT FOR MASTER AND RADIO TELEPHONY CERTIFICATE.
Accommodation/Occupational Safety
Issued 28 July 1998
Resolved
PRESSURE TEST BOTH AIR RECIEVERS' RELIEF VALVES.
Electrical
Issued 28 July 1998
Resolved
DEMONSTRATE OPERATION OF STBD GENERATOR.
Accommodation/Occupational Safety
Issued 28 July 1998
Resolved
LOCK CLOSED THE MSD OVERBOARD VALVE.
Navigation
Issued 12 June 1997
Resolved
PROVE PROPER OPERATION OF PORT SIDE RADAR.
Fire Fighting
Issued 6 June 1997
Resolved
Submit plans to G-MSC for approval on the newly installed fixed CO2 systemsin the machinery and generator spaces.
Lifesaving
Issued 6 June 1997
Resolved
Properly install the inflatable liferafts.
Fire Fighting
Issued 6 June 1997
Resolved
Prove proper operation of the fire pump guage.
Navigation
Issued 6 June 1997
Resolved
Prove proper operation of the starboard side radar.
Lifesaving
Issued 6 June 1997
Resolved
Complete underway man overboard and fire drills to the satisfaction of the attending marine inspector.
Construction/Loadline
Issued 24 January 1996
Resolved
VESSEL GRANTED PERMISSION TO PROCEED TO SHIPYARD IN PROVIDENCE, RI FOR DRYDOCKING AND REPAIRS. NO PASSENGERS NOR CARGO ARE TO BE CARRIED. [name withheld], RI SHALL BE CONTACTED IMMEDIATELY UPON ARRIVAL AND DAMAGE SURVEY OF THE VESSEL CONDUCTED.
Fire Fighting
Issued 8 November 1994
Resolved
RENEW GAUGE ON FIRE MAIN.
Construction/Loadline
Issued 8 November 1994
Resolved
REPLACE WASTED SECTION OF CROSSOVER PIPING BETWEEN BILGE AND FIRE PUMPS.
Deck/Cargo
Issued 8 November 1994
Resolved
MAKE PERMANENT REPAIRS TO DECK CAPSTAIN.
Documentation
Issued 2 August 1994
Resolved
DRYDOCK VESSEL FOR EXAMINATION NLT 15OCT94. A 45 DAY EXTENSION OF THE DRYDOCK INTERVAL HAS BEEN GRANTED EFFECTIVE 02AUG94.
Construction/Loadline
Issued 13 August 1992
Resolved
CROP OUT AND RENEW ALL WASTED SEACHEST SCREEN MOUNTING BRACKETS.
Construction/Loadline
Issued 16 July 1992
Resolved
MAKE PERMANENT REPAIR IN WAY OF TEMPORARY REPAIRS TO BILGE DISCHARGE PIPING.
Construction/Loadline
Issued 16 July 1992
Resolved
PROVIDE A PLAN FOR ELIMINATION OF ELECTROLYSIS IN VESSELS FIRE AND BILGE PIPING SYSTEM._x001C_ _x001C_ _x001C_
Casualty record · 10
13 April 2005Routine · role: Involved in a Marine Casualty · activity 2348228
24 October 2005Routine · role: Involved in a Marine Casualty · activity 2557586
3 January 2006Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2561363
15 June 2006Routine · role: Involved in a Marine Casualty · activity 2686976
14 February 2008Routine · role: Involved in a Marine Casualty · activity 3147945
24 July 2009Routine · role: Involved in a Marine Casualty · activity 3548765
22 October 2010Routine · role: Involved in a Marine Casualty · activity 3891738
24 January 2012Routine · role: Involved in a Marine Casualty · activity 4268848
6 February 2019Routine · role: Involved in a Marine Casualty · activity 6682940
6 January 2024Routine · role: Involved in a Marine Casualty · activity 7847218
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.