M. S. SHAHAN II

M. S. SHAHAN II is a 1990 passenger vessel (inspected). The Coast Guard has recorded 104 inspections since 1990, most recently in May 2026, along with 106 deficiencies and 10 casualty investigations between 2005 and 2024.

Records from 1990 to 2026. Most recent: inspection, 21 May 2026.

Built
1990
Last inspected
21 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDD7097
353333
Flag
UNITED STATES
367181880
Maury page id
psix-353333

Inspections, by type

…with no type recorded19
Years with a record 35 calendar years (1990–2026)
The 104 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)103.0 ft × 25.1 ft × 9.5 ft
Registered tonnagegross 94 / net 64
ITC dimensions (L × B × D)103.0 ft × 25.1 ft × 9.5 ft
ITC tonnagegross 190 / net 71
BuilderGULF CRAFT INC · PATTERSON, LA, UNITED STATES · built 1990
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portORIENT, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 14 May 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it71 - Convention (Subpart B), Net Ton
64 - Regulatory (Subpart C or D), Net Ton
190 - Convention (Subpart B), Gross Ton
94 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDD7097MMSI 367181880 · active · voluntarily equipped · granted 14 April 2017, expires 21 April 2027
WCX6063MMSI 366736260 · expired · compulsorily equipped · granted 14 July 1997, cancelled 15 September 2007
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 104

21 May 2026 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8377994
30 December 2025 In-Service Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8282538
5 August 2025 COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8178550
15 April 2025 Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8103394
19 December 2024 Internal Structural Exam · Drydock Extension
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8046760
5 June 2024 Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7926322
9 January 2024 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7847546
6 January 2024 Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7847218
3 May 2023 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7662777
19 December 2022 Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7606249
13 April 2022 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7430244
5 November 2021 Annual Inspection · Administrative Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7345837
8 April 2021 Deficiency Check · Deadweight Survey · Plan Review "T" Boat
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7166228
29 January 2021 Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7129117
21 October 2020 Internal Structural Exam · Administrative Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7081818
2 July 2020 COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6984669
28 March 2019 Administrative Inspection · Internal Structural Exam · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6650690
6 February 2019 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6682940
27 September 2018 Deficiency Check · Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6539948
28 August 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6525605
23 March 2018 Administrative Inspection · Internal Structural Exam · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6377361
29 May 2017 Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6137400
5 April 2017 Annual Inspection · Drydock Extension · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6119284
15 September 2016 Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6002251
21 June 2016 Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5914200
9 May 2016 Deficiency Check · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5872383
20 April 2016 Annual Inspection · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5857780
21 July 2015 Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5191575
12 June 2014 Annual Inspection · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4887141
12 June 2014 DAPI Audit
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4887159
13 May 2014 Examination of Repairs · Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4859635
19 June 2012 Annual Inspection · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4348732
30 January 2012 Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4234486
24 January 2012 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4268848
22 October 2010 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3891738
27 July 2009 Damage Survey
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3547756
24 July 2009 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3548765
20 June 2008 Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3247725
6 May 2008 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3202602
14 February 2008 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3147945
18 December 2007 Examination of Repairs · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3114392
12 June 2007 Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2959085
30 May 2007 Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2954068
12 April 2007 Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2906716
27 February 2007 Hull Examination · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2875315
28 September 2006 Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2788912
12 September 2006 Internal Structural Exam · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2776495
15 June 2006 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2686976
3 January 2006 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2561363
1 November 2005 Damage Survey
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2526089
24 October 2005 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2557586
19 July 2005 COI Inspection · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2432136
13 April 2005 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2348228
4 February 2005 Construction Oversight
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2286579
18 November 2004 Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2243560
10 November 2004 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2239783
30 July 2004 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2150625
17 February 2004 Examination of Repairs
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2005966
12 December 2003 Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1965263
19 November 2003 Annual Inspection · Internal Structural Exam
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1951698
24 October 2003 Uninspected Other
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1935190
23 September 2003 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2159669
4 February 2003 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1741261
4 February 2003 Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1742501
16 January 2003 Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1731567
19 December 2002 Internal Structural Exam · Annual Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1721518
12 September 2002 Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1674672
16 August 2002 In-Service Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1663452
16 August 2002 In-Service Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1672054
26 June 2002 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1635599
11 September 2001 Hull Examination · Re-Inspection · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1444607
9 January 2001 Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1056509
25 August 2000 Administrative
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 821921
2 August 2000 Deficiency Check · COI Inspection · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1384523
15 March 2000 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 131807
14 January 2000 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1467
24 August 1999 Re-Inspection · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1395274
23 July 1999 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1427683
28 July 1998 MARPOL Annex V Examination · Re-Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1122758
29 January 1998 Plan Review "T" Boat
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 805645
13 August 1997 Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1120957
12 June 1997 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1115983
6 June 1997 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 774469
3 June 1997 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1439887
26 January 1996 Damage Survey
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 882017
24 January 1996 Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 882590
23 January 1996 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 148025
20 November 1995 COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 879421
8 November 1994 COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1147458
13 October 1994 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1359936
2 August 1994 Excursion Permit
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 869658
30 November 1993 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 855157
24 September 1993 Excursion Permit
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1154737
31 May 1993 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1154928
27 April 1993 Excursion Permit
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 837557
1 December 1992 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 827351
19 October 1992 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1267881
28 August 1992 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 952682
13 August 1992 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1264305
16 July 1992 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1263963
10 March 1992 Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 949988
5 November 1991 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1249987
28 September 1991 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 228732
28 September 1990 Hull Examination · Initial Certification · Initial Construction-Excluding Oversight · Inclining Experiment
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1239089

Deficiency record · 106

02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 5 June 2024 Resolved
Inspection of all accessible parts of the exterior and interior of the hull, watertight bulkheads and weather decks are to be checked. Damaged weld was found on the weather deck in vicinity of aft starboard rub rail, affecting the watertight integrity of the ER space.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2024
Resolved 17 June 2024
Resolution: Repaired and tested; all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 June 2024 Resolved
Number of life jackets stowed inside each storage location must be marked in clearly identifiable letters and numers, at least 2 inches high. The label that states the number of life jackets was missing.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2024
Resolved 17 June 2024
Resolution: Placards were installed.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 13 April 2022 Resolved
Make repairs to machine space bilge suction and prove proper operation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 April 2022
Resolution: bilge suction has been repaired and is working
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 November 2021 Resolved
Provide MSC with an updated drawing that addresses the comments listed in MSC letter E2-2103244
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 December 2021
Resolution: Recieved MSC approval letter
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 5 November 2021 Resolved
A loop for the engine room CO2 fixed system had excessive wear and required replacing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 November 2021
Resolution: loop was replaced
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 November 2021 Resolved
Life jacket stowage at the bow area required labeling.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 November 2021
Resolution: Life jacket stowage has been labeled
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 November 2021 Resolved
Repairs or alterations to machinery or equipment that effect the safety of the vessel must not be made without the approval of the OCMI. Vessel repowered. Provide MSC approval letter for reference (a) through (d) in MSC Letter Serial: E2-2103244 dated October 25, 2021.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 November 2021
Resolved 5 November 2021
Resolution: Inspected electrical installation on throttle system to comply with comments in MSC letter E2-2103244
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 9 September 2021 Resolved
If during the inspection of a vessel, the vessel is found not to conform to the requirements of the regulations the MI will point out deficiency to Representative. Crack on main deck port side IWO engine room/house corner discovered during E/R inspection. Make repairs to the satisfaction of attending MI.
Action required: 705 - Other - as specified
Due 23 September 2021
Resolved 23 September 2021
Resolution: Repairs complete. NDT conducted using vacuum box. All sat.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 8 April 2021 Resolved
If during the inspection of a vessel, the vessel is found not to conform to the requirements of the regulations the MI will point out deficiency to Representative. Crack on main deck stbd side IWO engine room discovered during inspection of port side. Make repairs to the satisfaction of attending MI.
Action required: 705 - Other - as specified
Due 23 September 2021
Resolved 23 September 2021
Resolution: Repairs complete. NDT conducted using vacuum box. All sat.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 29 January 2021 Resolved
Repairs or alterations that affect the safety of the vessel include, but are not limited to: replacement and repairs to steering. OCMI may require an inspection and testing whenever a repair is undertaken. Pitting found on outboard fwd portion of both rudders. Make repairs to the satisfaction of attending Marine Inspector (MI).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 February 2021
Resolved 15 July 2021
Resolution: See activity #7166228.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 29 January 2021 Resolved
Repairs or alterations that affect the safety of the vessel include, but are not limited to: replacement and repairs to structural members. Foundation brackets of MSD transfer tank have cracks. Make repairs to the satisfaction of attending MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 February 2021
Resolved 9 September 2021
Resolution: See activity #7166228.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 29 January 2021 Resolved
Repairs or alterations that affect the safety of the vessel include, but are not limited to: replacement and repairs to structural members. Repair 04 cracked welds found on STBD bow bulwarks.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 February 2021
Resolved 9 September 2021
Resolution: See activity #7166228
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 29 January 2021 Resolved
Repairs or alterations that affect the safety of the vessel include, but are not limited to: replacement and repairs to structural members. Port aft corner of bulwarks has damage. Make repairs to the satisfaction of attending MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 February 2021
Resolved 9 September 2021
Resolution: See activity #7166228
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 September 2018 Resolved
Properly repair/replace the leaky seal and worn coupler on the bow thruster
Action required: 705 - Other - as specified
Due 27 October 2018
Resolved 23 October 2018
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 September 2018 Resolved
Remove all oil form the bilges in the forepeak space
Action required: 705 - Other - as specified
Due 27 October 2018
Resolved 26 October 2018
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 27 September 2018 Resolved
Properly repair the deck fitting or remove for the phone wire on the port side aft
Action required: 705 - Other - as specified
Due 27 October 2018
Resolved 23 October 2018
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 28 August 2018 Resolved
Vsl is broadcasting broadcasting incorrect Name and greater than expected vessel length
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 November 2018
Resolved 25 June 2019
Resolution: Verified CG NAVCEN VIVS, no AIS deficiencies pending per website.
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder Liner
Issued 15 September 2016 Resolved
Port engine overheated, bad cylinder cooling nozzel.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 September 2016
Resolved 15 September 2016
Resolution: Repairs completed to port main diesel.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 15 September 2016 Resolved
Cacked propeller shaft.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 September 2016
Resolved 15 September 2016
Resolution: New shaft installed, operational test sat.
Construction/Loadline › Hull › Hull Plating
Issued 20 April 2016 Resolved
Clean/inspect/repair pitting below PS battery box in transom.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 May 2016
Resolved 23 May 2016
Construction/Loadline › Penetrations › Pipe Flange
Issued 20 April 2016 Resolved
Seal all wiring/piping penetrations all water tight bulkheads
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 20 May 2016
Resolved 21 June 2016
Resolution: All penetrations sealed.
Engineering › Steering Gear System › Hydraulic Hose
Issued 20 April 2016 Resolved
Repair hydraulic hose STBD located in void 1 for bow thruster.
Action required: 705 - Other - as specified
Due 20 May 2016
Resolved 21 June 2016
Resolution: Hydraulic hose replaced.
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 12 June 2014 Resolved
Replace 03 hydrostatic release units on life rafts.
Due 30 June 2014
Resolved 8 July 2014
Resolution: Hydrostatic releases replaced.
Construction/Loadline › Penetrations › Weld
Issued 21 December 2007 Resolved
Port and stbd deck penetrations for midship mooring bits must be completed and hose tested.
Action required: 705 - Other - as specified
Due 4 January 2008
Resolved 26 December 2007
Resolution: Inspected welds for both port and starboard amidship mooring bits and completed satisfactory hose test.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 30 May 2007 Resolved
Repair or replace the pull handles on the main deck.
Due 29 June 2007
Resolved 15 June 2007
Resolution: Cleared via faxed receipt of fire system servicing.
Construction/Loadline › Structures › Deck Plating
Issued 9 March 2007 Resolved
Submit for approval to the local OCMI permanent repair plan for cracked welds noted on the doubler of the 2nd stbd bit from aft at the deck line.
Action required: 705 - Other - as specified
Due 9 April 2007
Resolved 30 May 2007
Resolution: Discussed permanent repairs with vessel rep.
Engineering › Thrusters › Motor
Issued 9 March 2007 Resolved
Replace in kind bow thruster muffler located on the stbd side in lazarette for holes noted in the spark/flame arrester at bottom of unit. Temp repair of martex approved until replacement unit is delivered or due date.
Action required: 705 - Other - as specified
Due 9 April 2007
Resolved 11 April 2007
Resolution: New Muffler installed
Construction/Loadline › Hull › Hull Plating
Issued 12 September 2006 Resolved
Repair Crack on port quarter.
Due 26 September 2006
Resolved 28 September 2006
Resolution: Cleared via email with pictures.
Electrical › Electric Generation Source (service) › Panelboard
Issued 19 July 2005 Resolved
Replace 1 volt meter on switchboard.
Condition: Improper Installation
Due 15 August 2005
Resolved 8 August 2005
Resolution: 08/08/05: Replaced Volt Meter. Cleared [name withheld]
Engineering › Thrusters › Piping
Issued 19 July 2005 Resolved
Repair all union leaks on bow thruster hydraulic systems.
Condition: Unknown
Due 8 August 2005
Resolved 8 August 2005
Resolution: 08/08/05: Visited vessel to perform DEF check on remaining DEF. Problem corrected. cleared DEF. [name withheld]
Fire Fighting › Ventilation Systems › Ducts
Issued 19 July 2005 Resolved
Prove proper operation of vent closures for E/R compt.
Due 8 August 2005
Resolved 8 August 2005
Resolution: 08/08/05: Ventilation system repaired. Cleared [name withheld]
Construction/Loadline › Structures › Door
Issued 19 July 2005 Resolved
Adjust all watertight doors below deck as needed.
Due 8 August 2005
Resolved 8 August 2005
Resolution: 08/08/05: All watertight doors inspected SAT. Cleared [name withheld]
Electrical › Lighting (service) › Lighting Feeder
Issued 19 July 2005 Resolved
replace missing light cover in E/R vestibule.
Condition: Unknown
Due 8 August 2005
Resolved 8 August 2005
Resolution: 08/08/05: Replaced Light Cover in Engine Room. Cleared. [name withheld]
Engineering › Pressure Vessel › Relief Valve
Issued 19 July 2005 Resolved
Conduct pressure test of new air receiver relief valve and front plug.
Due 8 August 2005
Resolved 8 August 2005
Resolution: 08/08/05: Conducted Pressure test of Pressure Vessel and relief Valve. Test Sat. Cleared [name withheld]
Operations/Management › Ballast Water Managment › Submission of Report
Issued 4 February 2005 Resolved
Provide plans for newly installed bilge system.
Due 25 April 2005
Resolved 1 August 2005
Resolution: Bigle systme and piping was not altered only renewed.
Documentation › Safety/Response Plans/Programs › General Arrangement Plans
Issued 4 February 2005 Resolved
Provide approved copies of submitted plans for: electrical system, Engine controls, air reciever, hot water heating plan.
Due 25 April 2005
Resolved 1 August 2005
Resolution: Plans received.
Lifesaving › Inflatable Liferafts › Markings
Issued 10 November 2004 Resolved
provide life raft lauching instructions.
Due 17 November 2004
Resolved 18 November 2004
Resolution: Sighted instructions
Electrical › Electrical Distribution System (service) › Switchboard
Issued 10 November 2004 Resolved
Provide proper mat for switchboard.
Due 17 November 2004
Resolved 18 November 2004
Resolution: sighted mat.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 10 November 2004 Resolved
prove servicing of fixed CO2 system.
Due 17 November 2004
Resolved 18 November 2004
Resolution: Sighted servicing report
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 10 November 2004 Resolved
Reinstall engine exhaust lagging where missing.
Due 17 November 2004
Resolved 18 November 2004
Resolution: Sighted lagging installed
Engineering › Sea-water System (primary cooling) › Piping
Issued 10 November 2004 Resolved
Replace outboard P/S MDE raw water hoses.
Due 17 November 2004
Resolved 18 November 2004
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 10 November 2004 Resolved
Prove proper operation of ground fault detection.
Due 17 November 2004
Resolved 12 September 2006
Resolution: graound fault dection is sat
Documentation › Certificates/Documents › Certificate of Inspection
Issued 10 November 2004 Resolved
Vessel was overdue for annual exam by 7 days.
Due 10 November 2004
Resolved 10 November 2004
Resolution: Exam conducted
Construction/Loadline › Structures
Issued 19 November 2003 Resolved
Repair all cracks, stbd fwd, bulwark at upper rail, including bits and center frams.
Due 5 December 2003
Resolved 12 December 2003
Construction/Loadline › Structures
Issued 19 November 2003 Resolved
Repair cracked welds port side, fwd rail
Due 5 December 2003
Resolved 12 December 2003
Resolution: Sighted repairs
Accommodation/Occupational Safety › Occupational Safety
Issued 19 November 2003 Resolved
Repair exterior ladder starboard side, cracked weld. replace bolt on port rail. LEGACY COMPONENT DESC: Deck Rail
Due 5 December 2003
Resolved 12 December 2003
Resolution: Sighted repairs
Accommodation/Occupational Safety › Occupational Safety
Issued 19 November 2003 Resolved
Replace/provide proper labels throughout vsl, ie; child lifejackets, forepeak shut off and fire station #2. LEGACY COMPONENT DESC: Labels
Due 5 December 2003
Resolved 12 December 2003
Resolution: Sighted labels
Engineering › Diesel Engine (propulsion/auxiliary-electric)
Issued 19 November 2003 Resolved
Repair exhaust leak, stbd generator. LEGACY COMPONENT DESC: Piping (exhaust)
Due 5 December 2003
Resolved 12 December 2003
Resolution: Test ran SSDG
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 19 November 2003 Resolved
Replace engine room lagging as needed LEGACY COMPONENT DESC: Piping (exhaust)
Due 5 December 2003
Resolved 12 December 2003
Resolution: Lagging replaced
Engineering › Diesel Engine (propulsion/auxiliary-electric)
Issued 19 November 2003 Resolved
Repair fuel leak on generator return line. LEGACY COMPONENT DESC: Fuel return line
Due 5 December 2003
Resolved 12 December 2003
Resolution: Fuel line repaired
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 19 December 2002 Resolved
Prove monthly portable fire extinguishing maintenance is completed. LEGACY COMPONENT DESC: Monthly Inspection
Condition: Improper/Lack of Maintenance
Due 19 January 2003
Resolved 16 January 2003
Resolution: Portable fire extinguishers serviced as required.
Documentation › Certificates/Documents
Issued 19 December 2002 Resolved
Mount COI with all pages visible to passengers. LEGACY COMPONENT DESC: Certificate of Inspection
Due 19 January 2003
Resolved 16 January 2003
Resolution: COI mounted as required.
Electrical › Electrical Distribution System (service)
Issued 19 December 2002 Resolved
Remove extention cord from under the aft bridge shelf and hard wire the computer with power strip. LEGACY COMPONENT DESC: Wiring
Due 19 January 2003
Resolved 16 January 2003
Resolution: Extension cord removed and wire as required.
Accommodation/Occupational Safety › Medical/First Aid
Issued 19 December 2002 Resolved
Provide asprin for the first aid kit. LEGACY COMPONENT DESC: Medicine Chest
Due 19 January 2003
Resolved 16 January 2003
Resolution: First aid kit sat.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 19 December 2002 Resolved
Install new fixed CO2 system to the satisfaction of attending marine inspector. LEGACY COMPONENT DESC: New system
Due 30 May 2003
Resolved 22 March 2005
Resolution: All seamed co2 piping removed and non seamless piping installed.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 19 December 2002 Resolved
Replace stbd. outboard MDE stbd turbo hose to the MDE LEGACY COMPONENT DESC: Turbo hose
Due 19 January 2003
Resolved 16 January 2003
Resolution: Hose renewed.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 19 December 2002 Resolved
Replace the stbd inboard MDE raw water discharge hose. LEGACY COMPONENT DESC: Raw water discharge hose
Due 19 January 2003
Resolved 16 January 2003
Resolution: Hose renewed; operational test sat.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 19 December 2002 Resolved
Replace the stbd. inboard MDE gasket on the stbd inbd turbo. LEGACY COMPONENT DESC: Turbocharger
Due 19 January 2003
Resolved 16 January 2003
Resolution: Gasket replaced; operational test sat.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 19 December 2002 Resolved
Make proper repairs to strb inbd MDE stbd exhaust pipe. LEGACY COMPONENT DESC: Piping (exhaust)
Due 19 January 2003
Resolved 16 January 2003
Resolution: Operational test sat.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 19 December 2002 Resolved
Replace stbd inbd MDE raw water discharge hose. LEGACY COMPONENT DESC: Raw water hose
Due 19 January 2003
Resolved 16 January 2003
Resolution: Hose renewed; operational test sat.
Construction/Loadline › Hull
Issued 19 December 2002 Resolved
Re-seal all deck hatches over MDE's. LEGACY COMPONENT DESC: Soft patches over MDE''''s
Due 19 January 2003
Resolved 16 January 2003
Resolution: Seals renewed; hose test sat.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 19 December 2002 Resolved
Port outbd MDE outbd turbo replace hose and tighten hose clamps. LEGACY COMPONENT DESC: Turbo
Due 19 January 2003
Resolved 16 January 2003
Resolution: Hose renewed; operational test sat.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 19 December 2002 Resolved
Port outbd MDE turbo stbd side make repairs to stop oil leak. LEGACY COMPONENT DESC: Turbo
Due 19 January 2003
Resolved 16 January 2003
Resolution: Operational test sat.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 19 December 2002 Resolved
Replace head cover gasket on port outboard MDE LEGACY COMPONENT DESC: Cylinder Head
Due 19 January 2003
Resolved 16 January 2003
Resolution: Head bolts tightened; operational test sat; new gasket on order.
Electrical › Electric Generation Source (service)
Issued 19 December 2002 Resolved
Stbd generator cooling water leak in cooling system hose. LEGACY COMPONENT DESC: Water leak
Due 19 January 2003
Resolved 16 January 2003
Resolution: Hose renewed; test run sat.
Navigation › Piloting/Steering
Issued 19 December 2002 Resolved
Tighten rudder post bolts on port side. LEGACY COMPONENT DESC: Rudder post
Due 19 January 2003
Resolved 16 January 2003
Resolution: Bolts tightened; operational test sat.
Engineering › Compressed Air System (start air)
Issued 19 December 2002 Resolved
Prove proper operation of 2 relief valves on strb and one on the port air compressers LEGACY COMPONENT DESC: Valve
Due 19 January 2003
Resolved 16 January 2003
Resolution: New relief valves installed and hand relief test sat.
Operations/Management › Drills/Instruction
Issued 19 December 2002 Resolved
Provide written directions for bilge and fire systems. LEGACY COMPONENT DESC: Fire
Due 19 January 2003
Resolved 16 January 2003
Resolution: Bilge/fire system directions posted.
Electrical › Electric Generation Source (service)
Issued 19 December 2002 Resolved
Provide proper lagging for stbd generator exhust system. LEGACY COMPONENT DESC: lagging
Due 19 January 2003
Resolved 16 January 2003
Resolution: Lagging installed as required.
Electrical › Electric Generation Source (service)
Issued 19 December 2002 Resolved
Provide voltmeter for the port generator. LEGACY COMPONENT DESC: volt meter
Due 19 January 2003
Resolved 16 January 2003
Resolution: Local meter removed, switchboard meter test sat.
Electrical › Electric Generation Source (service)
Issued 19 December 2002 Resolved
Make proper repairs to stbd generator exhaust leak. LEGACY COMPONENT DESC: Exhaust leak
Due 19 January 2003
Resolved 16 January 2003
Resolution: Repairs made and test run sat.
Construction/Loadline › Hull
Issued 19 December 2002 Resolved
Make proper repair to open seam in hull, stern section aft stbd side in corner above the rub rail LEGACY COMPONENT DESC: Hull Plating
Due 31 January 2003
Resolved 3 February 2003
Resolution: Witnessed satisfactory hose test of repair.
Pollution Prevention/Response
Issued 16 August 2002 Resolved
Excess of oily wast in the bilge. LEGACY COMPONENT DESC: Oil and fuel in the bilge
Due 16 August 2002
Resolved 16 August 2002
Resolution: Wast was removed.
Engineering › Bilge Water Management System
Issued 26 June 2002 Resolved
Pump bound up. LEGACY COMPONENT DESC: Pump
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 July 2002
Resolved 16 July 2002
Resolution: COTP LI [name withheld] cleared.
Engineering › Bilge Water Management System
Issued 26 June 2002 Resolved
Provide documentation attesting that "dresser couplers" style 38 installed on bilge suction lines are acceptable for vital systems IAW sub T. LEGACY COMPONENT DESC: Piping
Condition: Improper Installation
Due 30 July 2004
Resolved 13 September 2002
Resolution: Spoke with the Dresser Company and found the style 38 fitting approprate for the aplication. Ref. G-MSC-2 letter dated June 1988 and approved coupler in discharge side of bilge line.
Construction/Loadline
Issued 2 August 2000 Resolved
Provide audible alarms for bilge high level alarm system
Condition: Unknown
Due 2 September 2000
Resolved 12 September 2000
Construction/Loadline
Issued 2 August 2000 Resolved
Repair holes in bilge piping in way of bilge manifold
Condition: Unknown
Due 17 August 2000
Resolved 12 September 2000
Construction/Loadline
Issued 2 August 2000 Resolved
Demonstrate satisfactory operation of bilge pumping system
Condition: Unknown
Due 17 August 2000
Resolved 12 September 2000
Lifesaving
Issued 2 August 2000 Resolved
provide copies of August 2000 training/drill logs
Condition: Unknown
Due 2 September 2000
Resolved 12 September 2000
Engineering
Issued 2 August 2000 Resolved
Repair port outboard MDE low water alarm
Condition: Unknown
Due 2 September 2000
Resolved 12 September 2000
Engineering
Issued 24 August 1999 Resolved
PROVE PROPER OPERATION OF SHIP'S HEATER SAFETY DEVICES AS INSTALLED.
Condition: Unknown
Due 24 August 1999
Resolved 24 August 1999
Engineering
Issued 24 August 1999 Resolved
EXTEND PRESSURE/TEMP DISCHARGE PIPE TO TERMINATE 1" OFF OF THE DECK.
Condition: Unknown
Due 24 August 1999
Resolved 24 August 1999
Documentation
Issued 24 August 1999 Resolved
COMPLETE ANNUAL DAPI COMMENTS BASED UPON ANNUAL REVIEW.
Condition: Unknown
Due 24 August 1999
Resolved 24 August 1999
Fire Fighting
Issued 24 August 1999 Resolved
PROVIDE ADDITIONAL HOSE STATIONS AS REQUIRED TO MEET 46 CFR 181.15-5 (OLD SUB T). PRIOR TO FIRE MAIN MODIFICATIONS, PROVIDE PLANS TO THE COGNIZANT OCMI FOR APPROVAL.
Condition: Unknown
Due 24 August 1999
Resolved 24 August 1999
Fire Fighting
Issued 24 August 1999 Resolved
PROVIDE PIPE CERTIFICATION OF TYPE FOR CO2 SYSTEM PIPING.
Condition: Unknown
Due 6 October 1999
Resolved 6 October 1999
Lifesaving
Issued 23 July 1999 Resolved
Remove oil from bilge in void 2 (MSD Void), repair leaks in hydraulic linesto bow thruster at unions and at 45 degree elbow on aft bulkhead.
Condition: Unknown
Due 23 July 1999
Resolved 23 July 1999
Construction/Loadline
Issued 23 July 1999 Resolved
Submit plans for approval for additional high level alarm required in generator room. Upon approval install required alarm.
Condition: Unknown
Due 23 July 1999
Resolved 23 July 1999
Lifesaving
Issued 28 July 1998 Resolved
APPLY REFLECTIVE TAPE IN EACH QUADRANT, BOTH SIDES, ON THE ORANGE RING BUOYOUTSIDE THE BRIDGE.
Condition: Unknown
Due 28 July 1998
Resolved 28 July 1998
Documentation
Issued 28 July 1998 Resolved
PROVIDE RADIO OPERATOR'S PERMIT FOR MASTER AND RADIO TELEPHONY CERTIFICATE.
Condition: Unknown
Due 28 July 1998
Resolved 28 July 1998
Accommodation/Occupational Safety
Issued 28 July 1998 Resolved
PRESSURE TEST BOTH AIR RECIEVERS' RELIEF VALVES.
Condition: Unknown
Due 28 July 1998
Resolved 28 July 1998
Electrical
Issued 28 July 1998 Resolved
DEMONSTRATE OPERATION OF STBD GENERATOR.
Condition: Unknown
Due 28 July 1998
Resolved 28 July 1998
Accommodation/Occupational Safety
Issued 28 July 1998 Resolved
LOCK CLOSED THE MSD OVERBOARD VALVE.
Condition: Unknown
Due 28 July 1998
Resolved 28 July 1998
Navigation
Issued 12 June 1997 Resolved
PROVE PROPER OPERATION OF PORT SIDE RADAR.
Condition: Unknown
Due 12 June 1997
Resolved 12 June 1997
Fire Fighting
Issued 6 June 1997 Resolved
Submit plans to G-MSC for approval on the newly installed fixed CO2 systemsin the machinery and generator spaces.
Condition: Unknown
Due 6 June 1997
Resolved 6 June 1997
Lifesaving
Issued 6 June 1997 Resolved
Properly install the inflatable liferafts.
Condition: Unknown
Due 6 June 1997
Resolved 6 June 1997
Fire Fighting
Issued 6 June 1997 Resolved
Prove proper operation of the fire pump guage.
Condition: Unknown
Due 6 June 1997
Resolved 6 June 1997
Navigation
Issued 6 June 1997 Resolved
Prove proper operation of the starboard side radar.
Condition: Unknown
Due 6 June 1997
Resolved 6 June 1997
Lifesaving
Issued 6 June 1997 Resolved
Complete underway man overboard and fire drills to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 6 June 1997
Resolved 6 June 1997
Construction/Loadline
Issued 24 January 1996 Resolved
VESSEL GRANTED PERMISSION TO PROCEED TO SHIPYARD IN PROVIDENCE, RI FOR DRYDOCKING AND REPAIRS. NO PASSENGERS NOR CARGO ARE TO BE CARRIED. [name withheld], RI SHALL BE CONTACTED IMMEDIATELY UPON ARRIVAL AND DAMAGE SURVEY OF THE VESSEL CONDUCTED.
Condition: Unknown
Due 24 January 1996
Resolved 24 January 1996
Fire Fighting
Issued 8 November 1994 Resolved
RENEW GAUGE ON FIRE MAIN.
Condition: Unknown
Due 8 November 1994
Resolved 8 November 1994
Construction/Loadline
Issued 8 November 1994 Resolved
REPLACE WASTED SECTION OF CROSSOVER PIPING BETWEEN BILGE AND FIRE PUMPS.
Condition: Unknown
Due 8 November 1994
Resolved 8 November 1994
Deck/Cargo
Issued 8 November 1994 Resolved
MAKE PERMANENT REPAIRS TO DECK CAPSTAIN.
Condition: Unknown
Due 8 November 1994
Resolved 8 November 1994
Documentation
Issued 2 August 1994 Resolved
DRYDOCK VESSEL FOR EXAMINATION NLT 15OCT94. A 45 DAY EXTENSION OF THE DRYDOCK INTERVAL HAS BEEN GRANTED EFFECTIVE 02AUG94.
Condition: Unknown
Due 29 October 1994
Resolved 29 October 1994
Construction/Loadline
Issued 13 August 1992 Resolved
CROP OUT AND RENEW ALL WASTED SEACHEST SCREEN MOUNTING BRACKETS.
Condition: Unknown
Due 9 November 1992
Resolved 9 November 1992
Construction/Loadline
Issued 16 July 1992 Resolved
MAKE PERMANENT REPAIR IN WAY OF TEMPORARY REPAIRS TO BILGE DISCHARGE PIPING.
Condition: Unknown
Due 16 July 1992
Resolved 16 July 1992
Construction/Loadline
Issued 16 July 1992 Resolved
PROVIDE A PLAN FOR ELIMINATION OF ELECTROLYSIS IN VESSELS FIRE AND BILGE PIPING SYSTEM._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 July 1992
Resolved 16 July 1992

Casualty record · 10

13 April 2005Routine · role: Involved in a Marine Casualty · activity 2348228
24 October 2005Routine · role: Involved in a Marine Casualty · activity 2557586
3 January 2006Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2561363
15 June 2006Routine · role: Involved in a Marine Casualty · activity 2686976
14 February 2008Routine · role: Involved in a Marine Casualty · activity 3147945
24 July 2009Routine · role: Involved in a Marine Casualty · activity 3548765
22 October 2010Routine · role: Involved in a Marine Casualty · activity 3891738
24 January 2012Routine · role: Involved in a Marine Casualty · activity 4268848
6 February 2019Routine · role: Involved in a Marine Casualty · activity 6682940
6 January 2024Routine · role: Involved in a Marine Casualty · activity 7847218
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.