MAURY USCG vessel records
← All vessels

M. S. SHAHAN II

Built
1990
Last inspected
21 May 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 21 May 2026
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDD7097
353333
Flag
UNITED STATES
Maury page id
psix-353333

Documentation record

Registered dimensions (L × B × D)103.0 ft × 25.1 ft × 9.5 ft
Registered tonnagegross 94 / net 64
ITC dimensions (L × B × D)103.0 ft × 25.1 ft × 9.5 ft
ITC tonnagegross 190 / net 71
BuilderGULF CRAFT INC · PATTERSON, LA, UNITED STATES · built 1990
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portORIENT, NY
Endorsements, as the file codes themcw_un
DocumentationValid · issued 14 May 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it71 - Convention (Subpart B), Net Ton
64 - Regulatory (Subpart C or D), Net Ton
190 - Convention (Subpart B), Gross Ton
94 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 27 inspections, each with its date, unit and type; 22 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 27

21 May 2026 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8377994
30 December 2025 In-Service Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8282538
5 August 2025 COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8178550
15 April 2025 Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8103394
19 December 2024 Internal Structural Exam · Drydock Extension
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8046760
5 June 2024 Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7926322
9 January 2024 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7847546
6 January 2024 Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7847218
3 May 2023 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7662777
19 December 2022 Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7606249
13 April 2022 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7430244
5 November 2021 Annual Inspection · Administrative Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7345837
8 April 2021 Deficiency Check · Deadweight Survey · Plan Review "T" Boat
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7166228
29 January 2021 Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7129117
21 October 2020 Internal Structural Exam · Administrative Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7081818
2 July 2020 COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6984669
28 March 2019 Administrative Inspection · Internal Structural Exam · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6650690
6 February 2019 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6682940
27 September 2018 Deficiency Check · Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6539948
28 August 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6525605
23 March 2018 Administrative Inspection · Internal Structural Exam · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6377361
29 May 2017 Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6137400
5 April 2017 Annual Inspection · Drydock Extension · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6119284
15 September 2016 Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6002251
21 June 2016 Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5914200
9 May 2016 Deficiency Check · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5872383
20 April 2016 Annual Inspection · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5857780

Deficiency record · 22

02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 5 June 2024 Resolved
Inspection of all accessible parts of the exterior and interior of the hull, watertight bulkheads and weather decks are to be checked. Damaged weld was found on the weather deck in vicinity of aft starboard rub rail, affecting the watertight integrity of the ER space.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2024
Resolved 17 June 2024
Resolution: Repaired and tested; all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 June 2024 Resolved
Number of life jackets stowed inside each storage location must be marked in clearly identifiable letters and numers, at least 2 inches high. The label that states the number of life jackets was missing.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2024
Resolved 17 June 2024
Resolution: Placards were installed.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 13 April 2022 Resolved
Make repairs to machine space bilge suction and prove proper operation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 April 2022
Resolution: bilge suction has been repaired and is working
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 November 2021 Resolved
Provide MSC with an updated drawing that addresses the comments listed in MSC letter E2-2103244
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 December 2021
Resolution: Recieved MSC approval letter
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 5 November 2021 Resolved
A loop for the engine room CO2 fixed system had excessive wear and required replacing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 November 2021
Resolution: loop was replaced
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 November 2021 Resolved
Life jacket stowage at the bow area required labeling.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 November 2021
Resolution: Life jacket stowage has been labeled
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 November 2021 Resolved
Repairs or alterations to machinery or equipment that effect the safety of the vessel must not be made without the approval of the OCMI. Vessel repowered. Provide MSC approval letter for reference (a) through (d) in MSC Letter Serial: E2-2103244 dated October 25, 2021.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 November 2021
Resolved 5 November 2021
Resolution: Inspected electrical installation on throttle system to comply with comments in MSC letter E2-2103244
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 9 September 2021 Resolved
If during the inspection of a vessel, the vessel is found not to conform to the requirements of the regulations the MI will point out deficiency to Representative. Crack on main deck port side IWO engine room/house corner discovered during E/R inspection. Make repairs to the satisfaction of attending MI.
Action required: 705 - Other - as specified
Due 23 September 2021
Resolved 23 September 2021
Resolution: Repairs complete. NDT conducted using vacuum box. All sat.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 8 April 2021 Resolved
If during the inspection of a vessel, the vessel is found not to conform to the requirements of the regulations the MI will point out deficiency to Representative. Crack on main deck stbd side IWO engine room discovered during inspection of port side. Make repairs to the satisfaction of attending MI.
Action required: 705 - Other - as specified
Due 23 September 2021
Resolved 23 September 2021
Resolution: Repairs complete. NDT conducted using vacuum box. All sat.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 29 January 2021 Resolved
Repairs or alterations that affect the safety of the vessel include, but are not limited to: replacement and repairs to steering. OCMI may require an inspection and testing whenever a repair is undertaken. Pitting found on outboard fwd portion of both rudders. Make repairs to the satisfaction of attending Marine Inspector (MI).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 February 2021
Resolved 15 July 2021
Resolution: See activity #7166228.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 29 January 2021 Resolved
Repairs or alterations that affect the safety of the vessel include, but are not limited to: replacement and repairs to structural members. Foundation brackets of MSD transfer tank have cracks. Make repairs to the satisfaction of attending MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 February 2021
Resolved 9 September 2021
Resolution: See activity #7166228.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 29 January 2021 Resolved
Repairs or alterations that affect the safety of the vessel include, but are not limited to: replacement and repairs to structural members. Repair 04 cracked welds found on STBD bow bulwarks.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 February 2021
Resolved 9 September 2021
Resolution: See activity #7166228
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 29 January 2021 Resolved
Repairs or alterations that affect the safety of the vessel include, but are not limited to: replacement and repairs to structural members. Port aft corner of bulwarks has damage. Make repairs to the satisfaction of attending MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 February 2021
Resolved 9 September 2021
Resolution: See activity #7166228
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 September 2018 Resolved
Properly repair/replace the leaky seal and worn coupler on the bow thruster
Action required: 705 - Other - as specified
Due 27 October 2018
Resolved 23 October 2018
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 September 2018 Resolved
Remove all oil form the bilges in the forepeak space
Action required: 705 - Other - as specified
Due 27 October 2018
Resolved 26 October 2018
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 27 September 2018 Resolved
Properly repair the deck fitting or remove for the phone wire on the port side aft
Action required: 705 - Other - as specified
Due 27 October 2018
Resolved 23 October 2018
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 28 August 2018 Resolved
Vsl is broadcasting broadcasting incorrect Name and greater than expected vessel length
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 November 2018
Resolved 25 June 2019
Resolution: Verified CG NAVCEN VIVS, no AIS deficiencies pending per website.
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder Liner
Issued 15 September 2016 Resolved
Port engine overheated, bad cylinder cooling nozzel.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 September 2016
Resolved 15 September 2016
Resolution: Repairs completed to port main diesel.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 15 September 2016 Resolved
Cacked propeller shaft.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 September 2016
Resolved 15 September 2016
Resolution: New shaft installed, operational test sat.
Construction/Loadline › Hull › Hull Plating
Issued 20 April 2016 Resolved
Clean/inspect/repair pitting below PS battery box in transom.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 May 2016
Resolved 23 May 2016
Construction/Loadline › Penetrations › Pipe Flange
Issued 20 April 2016 Resolved
Seal all wiring/piping penetrations all water tight bulkheads
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 20 May 2016
Resolved 21 June 2016
Resolution: All penetrations sealed.
Engineering › Steering Gear System › Hydraulic Hose
Issued 20 April 2016 Resolved
Repair hydraulic hose STBD located in void 1 for bow thruster.
Action required: 705 - Other - as specified
Due 20 May 2016
Resolved 21 June 2016
Resolution: Hydraulic hose replaced.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.