MAURY USCG vessel records Sign in
← All vessels

MISS ALLISON

MISS ALLISON is a 1990 passenger vessel (inspected). The Coast Guard has recorded 26 inspections since 1990, most recently in October 2003, along with 10 deficiencies.

Records from 1990 to 2003. Most recent: inspection, 28 October 2003.

Built
1990
Last inspected
28 October 2003
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCV5697
353335
Flag
UNITED STATES
366540000 (licence lapsed)
Maury page id
psix-353335

Inspections, by type

…with no type recorded5
Years with a record 14 calendar years (1990–2003)
The 26 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 23 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it94 - Regulatory (Subpart C or D), Gross Ton
211 - Convention (Subpart B), Gross Ton
64 - Regulatory (Subpart C or D), Net Ton
63 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WCV5697MMSI 366540000 · cancelled · compulsorily equipped · granted 29 October 1998, cancelled 7 April 2004
WAP2987MMSI not assigned · expired · compulsorily equipped · granted 2 August 1995, cancelled 7 January 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 26

28 October 2003 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1937835
27 March 2002 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1598935
20 March 2001 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1412244
22 March 2000 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1395404
22 March 1999 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1461112
4 March 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 804665
12 August 1998 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1415037
3 October 1997 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 11967
13 August 1997 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1400621
24 February 1997 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1413120
23 July 1996 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1383300
16 September 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 54546
12 September 1995 Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 873257
11 September 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 12677
25 July 1995 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1402073
3 March 1995 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1355117
2 August 1994 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1435520
10 August 1993 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1415868
15 May 1993 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1410816
13 November 1992 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 50798
14 August 1992 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1373745
28 June 1992 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 81518
25 February 1992 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1262425
25 September 1991 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1243928
12 September 1991 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1251283
14 September 1990 Initial Certification · Inclining Experiment · Hull Examination · Initial Construction-Excluding Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1222999

Deficiency record · 10

Engineering › Steering Gear System
Issued 27 March 2002 Resolved
PORT RUDDER STOP BRACKET CRACKED. LEGACY COMPONENT DESC: Bracket/Clamp
Due 27 March 2002
Resolved 27 March 2002
Stability › Watertight Integrity
Issued 27 March 2002 Resolved
DECK VENT PLUGS WASTED. LEGACY COMPONENT DESC: DECK VENTS
Action required: 17 - Rectify deficiencies prior to departure
Due 27 March 2002
Resolved 27 March 2002
Engineering › Reduction Gearing/Clutches
Issued 27 March 2002 Resolved
REDUCTION GEAR HOSES CHAFFING ON FRAME. LEGACY COMPONENT DESC: HOSES
Due 27 March 2002
Resolved 27 March 2002
Lifesaving
Issued 27 March 2002 Resolved
HYDROSTATIC RELEASE MARKED WITH WRONG DATE. LEGACY COMPONENT DESC: EPIRB
Action required: 17 - Rectify deficiencies prior to departure
Due 27 March 2002
Resolved 27 March 2002
Stability › Watertight Integrity
Issued 27 March 2002 Resolved
ALL WATERTIGHT DOORS OUT OF ADJUSTMENT. LEGACY COMPONENT DESC: DOORS
Action required: 17 - Rectify deficiencies prior to departure
Due 27 March 2002
Resolved 27 March 2002
Fire Fighting › Ventilation Systems
Issued 27 March 2002 Resolved
FLAME SCREEN ON SEWAGE VENT RUPTURED. LEGACY COMPONENT DESC: FLAME SCREEN
Action required: 17 - Rectify deficiencies prior to departure
Due 27 March 2002
Resolved 27 March 2002
Documentation
Issued 22 March 2000 Resolved
PROVIDE RADIO EMERGENCY BROADCAST INSTRUCTIONS.
Condition: Unknown
Due 27 March 2000
Resolved 5 April 2000
Navigation
Issued 22 March 2000 Resolved
REPACK STARBAORD SIDE RUDDER POST PACKING GLAND.
Condition: Unknown
Due 27 March 2000
Resolved 5 April 2000
Navigation
Issued 22 March 2000 Resolved
REPAIR STARBOARD SIDE SPOTLIGHT.
Condition: Unknown
Due 27 March 2000
Resolved 5 April 2000
Electrical
Issued 22 March 2000 Resolved
PROVIDE METAL SUPPORTS FOR ELECTRICAL WIRING UNDE FORWARD STEERING CONSOLE.
Condition: Unknown
Due 27 March 2000
Resolved 5 April 2000

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.