MAURY USCG vessel records Sign in
← All vessels

SI SIRENA

SI SIRENA is a 1990 passenger vessel (inspected). The Coast Guard has recorded 91 inspections since 1990, most recently in April 2026, along with 276 deficiencies, 4 operational controls and 7 casualty investigations between 2007 and 2013.

Records from 1990 to 2026. Most recent: inspection, 9 April 2026.

Built
1990
Last inspected
9 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WED6334
353891
Flag
UNITED STATES
366140000
Maury page id
psix-353891

Inspections, by type

…with no type recorded18
Years with a record 34 calendar years (1990–2026)
The 91 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)50.3 ft × 15.0 ft × 3.5 ft
Registered tonnagegross 17 / net 14
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNOVA MARINE CO LTD · TAIWAN · built 1990
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portAGAT, GU
Trade endorsementsRegistry
DocumentationValid · issued 12 May 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it17 - Simplified, Gross Ton
14 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDQ8969MMSI 366140000 · active · compulsorily equipped · granted 11 April 2026, expires 11 April 2036
WDI5610MMSI 366140000 · cancelled · compulsorily equipped · granted 26 November 2025, cancelled 8 April 2026
WDE6334MMSI 367378920 · expired · compulsorily equipped · granted 1 October 2008, cancelled 1 December 2018
WCQ9632MMSI not assigned · expired · compulsorily equipped · granted 27 April 1995, cancelled 2 July 2005
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 91

9 April 2026 Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8345086
8 May 2025 Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8130125
17 March 2025 Annual Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8095408
13 March 2024 Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7878853
17 May 2023 In-Service Inspection · Internal Structural Exam · Drydock Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7691819
11 January 2023 COI Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7616011
26 April 2022 Annual Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7438940
26 May 2021 Annual Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7207056
11 May 2021 Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7193041
6 May 2021 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7190467
14 January 2021 Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7151554
5 May 2020 Annual Inspection · Administrative Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6951216
13 February 2020 Administrative Inspection · Deficiency Check · Spot Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6908893
13 February 2020 Type not recorded
No type recorded · Maritime Safety & Security Team Honolulu (91107) · Activity 6909044
1 November 2019 Deficiency Check · Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6848268
3 May 2019 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6682679
24 November 2018 Type not recorded
No type recorded · Station Apra Harbor · USCG Oceania District (CGD-O) · Activity 6585671
31 January 2018 COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6346717
28 May 2017 Drydock Extension · Internal Structural Exam · Drydock Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6157359
20 January 2017 Annual Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6073730
13 January 2016 Deficiency Check · Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5795544
14 June 2012 Spot Check · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4343325
8 June 2012 DAPI Audit
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4337056
13 December 2011 Deficiency Check · Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4206928
22 July 2011 Damage Survey
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4090130
27 October 2010 DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3878393
11 January 2010 Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3661671
9 July 2009 Deficiency Check · Damage Survey
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3529671
8 July 2009 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3529796
27 January 2009 Annual Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3400539
26 January 2009 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3418652
19 February 2008 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3149438
1 February 2008 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3139964
1 December 2007 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3113776
25 October 2007 COI Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3086580
1 October 2007 Hull Examination
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3070900
27 March 2007 Type not recorded
No type recorded · USCGC ASSATEAGUE (WPB 1337) · USCG Oceania District (CGD-O) · Activity 2910581
14 October 2006 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2801196
23 August 2006 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2764475
27 January 2006 Type not recorded
No type recorded · District 14 (OAX) · USCG Oceania District (CGD-O) · Activity 2574907
27 October 2005 Annual Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2522933
19 September 2005 Hull Examination
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2496557
22 August 2005 Type not recorded
No type recorded · USCGC GALVESTON ISLAND (WPB 1349) · USCG Oceania District (CGD-O) · Activity 2479127
18 November 2004 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 2243219
29 October 2004 Annual Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 2230586
23 December 2003 Annual Inspection · Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1968569
3 September 2003 Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1890562
26 October 2002 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1734163
23 October 2002 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1694587
3 October 2002 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1683519
3 October 2001 Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1370386
6 August 2001 Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1366492
9 June 2000 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1050580
18 May 2000 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1049794
7 November 1999 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 806706
6 October 1999 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1402954
26 August 1999 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 780232
25 August 1999 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 780230
12 July 1999 Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1381620
4 June 1999 Administrative
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 811013
9 May 1999 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1129101
3 April 1999 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 785387
5 January 1999 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 815041
22 October 1998 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 801342
2 October 1998 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 802895
24 September 1998 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1368864
4 February 1998 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1107853
4 November 1997 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1368460
3 November 1997 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 782206
9 October 1997 Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1364396
10 June 1997 Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 775616
11 April 1997 Administrative
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1091276
3 April 1997 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1094626
17 December 1996 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1101863
2 October 1996 COI Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1143587
21 June 1996 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1090298
26 April 1996 Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1083098
12 April 1995 Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1357125
1 November 1994 Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1177652
25 October 1993 COI Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 838520
22 April 1993 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 215799
5 April 1993 Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1147735
21 December 1992 Administrative
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1136327
15 December 1992 Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 830987
24 August 1992 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 945501
20 May 1992 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 57944
25 December 1991 Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 962393
21 November 1991 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1247627
15 October 1991 Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 941285
16 December 1990 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1240757
9 October 1990 COI Inspection · Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 904672

Deficiency record · 276

10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 18 March 2025 Resolved
U.S. Coast Pilot and CG Light List were outdated. Provide a copy of up to date publications and ensure on board at all times. 46 CFR 185.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2025
Resolved 19 March 2025
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 March 2025 Resolved
Portable fire extinguishers must be located so that they are clearly visible and readily accessible from the space being protected. The installation and location must be to the satisfaction of the Officer in Charge, Marine Inspection. The aft compartment's portable fire extinguisher was not mounted. 46 CFR 181.520
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2025
Resolved 19 March 2025
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 26 April 2022 Resolved
EPIRB registration is expired. 46CFR180.64
Action required: 10 - Deficiency Rectified
Resolved 26 April 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 April 2022 Resolved
Ring Buoy Floating Water Light Battery is expired. 46CFR180.70
Action required: 10 - Deficiency Rectified
Resolved 26 April 2022
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 26 April 2022 Resolved
Pre-Engineered (Fireboy) extinguishing systems manual operation was disable by the installation of the servicing pin at the bottle and the manual pull handle being secured in a way to prevent operation of handle. 46CFR181.420(2)
Action required: 10 - Deficiency Rectified
Resolved 26 April 2022
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 26 April 2022 Resolved
Identified loose rail attachment points on the port and starboard side of the vessel around the mid ship area and port handle on the aft ladder. 46CFR177.900
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2022
Resolved 31 May 2022
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 April 2022 Resolved
Emergency instructions and Radio Operations placards were worn and illegible and require renewal. 46CFR185.510
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2022
Resolved 31 May 2022
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 April 2022 Resolved
Forward Emergency Escape marking needs to be renewed. 46CFR177.500
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2022
Resolved 31 May 2022
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 26 April 2022 Resolved
Vessel does not have a log book on-board. 46CFR185.728
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2022
Resolved 31 May 2022
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 26 May 2021 Resolved
Port main engine alarming on operator's station.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 May 2021
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 6 May 2021 Resolved
Your vessel must undergo an annual inspection within 3 months before or after each anniversary date. Vessel missed annual inspection. 46 CFR 176.500(b)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 June 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 24 August 2020 Resolved
46 CFR 177.1020: Each window and its means of attachment to the hull or deckhouse, must be capable of withstanding the maximum load from wave and wind conditions. Repair or replace cracked starboard side window in passenger accommodation space to as original.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 September 2020
Resolved 14 January 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 24 August 2020 Resolved
46 CFR 177.900(b): Deck rails must be designed and constructed to withstand a point load of 200 pounds applied at any point in any direction. Repair broken starboard side deck rail to as original.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 September 2020
Resolved 14 January 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 August 2020 Resolved
46 CFR 182.520(e)(3): The pump is permanently mounted. Secure strainer for submersible electrical bilge pump in engine room compartment to bilge and properly attach bilge pump to strainer.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 January 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 24 August 2020 Resolved
46 CFR 182.100: All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from machinery failure and personnel injury. Repair hydraulic leak in aft steering.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 January 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 August 2020 Resolved
46 CFR 182.604(h): Each life jacket must be marked with Type I retro-reflective material approved in 46 CFR 164.018. Replace deteriorated retro-reflective tape on 9 x adult and 5 x children life jackets with new. Vessel is restricted to carrying no more than 38 passengers and no children until number of life jackets inspected with damaged/deteriorated retro-reflective tape are replaced with new to the satisfaction of the attending MI.
Action required: 705 - Other - as specified
Resolved 14 January 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 August 2020 Resolved
46 CFR 185.604: The number and identification of the items stowed inside and their sizes, must be marked in clearly legible letters and numbers for life jackets. Visibly mark locations where adult and children life jackets are stored.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 January 2021
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 13 February 2020 Resolved
46 CFR 15.401(a): It was reported by MSST HONO that the operator on SI SIRENA did not have in possession his USCG MMD credential while vessel was carrying passengers for Pending proof of a valid USCG MMD credential or operator in possession of a USCG MMD credential with appropriate tonnage and route, vessel is prohibited from carrying passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 February 2020
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 1 November 2019 Resolved
46 CFR 181.420: Pre-engineered fixe gas fire extinguishing system found not in compliance with manufacturer's instructions. Fusible element missing inside high temperature glass. Vsl rep to replace discharge head with new or entire system in accordance with manufacturer's specifications.
Action required: 705 - Other - as specified
Resolved 14 February 2020
Resolution: New inkind pre-engineered fire extinguishing system from Fireboy installed and inspected by 3rd party.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Other (MARPOL Annex IV)
Issued 1 November 2019 Resolved
33 CFR 151.59:Replace missing placard for prohibiting discharge of sewage within 3 miles from shore.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2019
Resolved 20 November 2019
Resolution: Placard posted IWO MSD overboard valve.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 November 2019 Resolved
46CFR 180.71: Total of 17 adult life jackets to be replaced with new, USCG approved Type 1. Life jackets inspected with multiple tears that penetrate through outerlayer exposing inner core. Vessel is reduced to carrying no more than 32 adult passengers.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 November 2019
Resolved 4 November 2019
Resolution: Adult life jackets with tears replaced with new USCG Type I.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 November 2019 Resolved
46 CFR 180.78: Missing signs where to show where life jackets for adult and children are stowed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 November 2019
Resolution: Signs posted with indication arrows for adult/child life jacket locations.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 November 2019 Resolved
46 CFR 182.465: Openings for port and starboard engine room ventilation above engine room compartment is blocked with new wood and sheet metal preventing airflow across the back of the engine to the front. The ventilation system should sufficiently move air to control temperature in all areas of the engine room. Repair to as original.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 November 2019
Resolved 15 November 2019
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 1 November 2019 Resolved
46 CFR 181.420: Manual pull cable for activiting Fireboy inside the forward passenger cabin to be relocated to the operating station to prevent passengers from accidentally pulling cable. Vsl owner reported to USCG that passengers will play with the cable or remove the pin to keep as a souvenir.
Action required: 705 - Other - as specified
Due 30 December 2020
Resolved 7 June 2021
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 November 2019 Resolved
46 CFR 177.405(f): Replace missing non-combustible receptacles on deck and in forward washroom.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 November 2019
Resolved 20 November 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 7 May 2019 Resolved
Pending satisfactory completion of annual inspection for 2019YR, vessel is prohibited from operating with passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 November 2019
Stability › Watertight Integrity › Coaming
Issued 6 February 2018 Resolved
46 CFR 179.360: Replace watertight gasket for steering room hatch cover with new.
Action required: 705 - Other - as specified
Due 15 February 2018
Resolved 13 February 2018
Fire Fighting › Means of Escape › Escape Route Signs
Issued 6 February 2018 Resolved
46 CFR 185.606: Remark faded emergency exit sign in forward cabin.
Action required: 705 - Other - as specified
Due 15 February 2018
Resolved 13 February 2018
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 6 February 2018 Resolved
46 CFR 180.70: Replace battery with new for ring buoy float light; vessel is restricted to daylight operations pending proof of new battery.
Action required: 705 - Other - as specified
Due 15 February 2018
Resolved 13 February 2018
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 6 February 2018 Resolved
46 CFR 176.25-50: Remove or properly cap off dead end wire below operator station.
Action required: 705 - Other - as specified
Due 15 February 2018
Resolved 13 February 2018
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 6 February 2018 Resolved
46 CFR 180.25-15: Designated storage locations for child life jackets must be marked.
Action required: 705 - Other - as specified
Due 15 February 2018
Resolved 13 February 2018
Fire Fighting › Remote Fuel Shutoff › General
Issued 6 February 2018 Resolved
46 CFR 176.25-50: Install chaffing guards for fuel shutoff pull cables; cables penetrate through sheet metal attached to engine room overhead.
Action required: 705 - Other - as specified
Due 15 February 2018
Resolved 16 March 2018
Navigation › Piloting/Steering › Magnetic Compass
Issued 6 February 2018 Resolved
46 CFR 184.402(c): Prove proper operation of compass light; restricted to daylight operations pending corrective action.
Action required: 705 - Other - as specified
Due 15 February 2018
Resolved 6 March 2018
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 6 February 2018 Resolved
46 CFR 185.604: Remark ring buoy with vessel's name and port in 2" block capital letters.
Action required: 705 - Other - as specified
Due 15 February 2018
Resolved 13 February 2018
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 6 February 2018 Resolved
46 CFR 182.05-1: Submit proof of new tachometer for starboard main engine and estimated date of delivery.
Action required: 705 - Other - as specified
Due 15 February 2018
Resolved 16 March 2018
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 6 February 2018 Resolved
46 CFR 16: Submit proof of enrollment for random drug testing for crewmembers employed in safety sensitive position.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 February 2018
Documentation › Certificates/Documents › Certificate of Inspection
Issued 31 January 2018 Resolved
46 CFR 176.404: Subsequent inspections for COI renewal 3 months overdue. Vessel's COI expired on 18OCT2017.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 February 2018
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 20 January 2017 Resolved
46 CFR 177.405(f): Garbage waste receptacle must be of a non-combustible type.
Due 27 January 2017
Resolved 31 January 2017
Personnel › Training › First Aid/CPR
Issued 20 January 2017 Resolved
NAVIC 1-91: Provide proof of first/aid CPR training for 50% of crew required on board during operations.
Due 28 February 2017
Resolved 1 May 2017
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 20 January 2017 Resolved
46 CFR 183.200(b): Remove all dead end wires in forward void where MSD tank is located.
Due 27 January 2017
Resolved 31 January 2017
Communications › Radio Communications › VHF Radiotelephone
Issued 20 January 2017 Resolved
47 CFR 80.13: MMSI not programmed into VHF radio.
Due 27 January 2017
Resolved 15 February 2017
Fire Fighting › Means of Escape › Escape Route Signs
Issued 20 January 2017 Resolved
46 CFR 177.500: Means of escape must be marked and clear of obstruction.
Due 27 January 2017
Resolved 31 January 2017
Engineering › Bilge Water Management System › Pump
Issued 20 January 2017 Resolved
46 CFR 185.602(g): Replace non-approved bilge pump with UL approved type, UL113, in forward void.
Due 28 February 2017
Resolved 28 February 2017
Operations/Management › Passenger Operations › Safety Orientation
Issued 20 January 2017 Resolved
46 CFR 185.602(g): Clearly mark passenger capacity for upper deck.
Due 27 January 2017
Resolved 31 January 2017
Fire Fighting › Fire Bucket › Capacity
Issued 20 January 2017 Resolved
46 CFR 181.610: Fire buckets must be of 2.5 gallon type.
Due 27 January 2017
Resolved 31 January 2017
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 20 January 2017 Resolved
46 CFR 183.200(b): Repair electrical outlet in forward washroom to as original or prove power secured to prevent from being accidentally used.
Due 27 January 2017
Resolved 31 January 2017
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 13 January 2016 Resolved
Missing bracket for II fire extinguisher, per 46 CFR 181.500.
Action required: 705 - Other - as specified
Due 13 February 2016
Resolved 19 January 2016
Resolution: Owner replaced A-II fire extinguisher with a B-I, extinguisher with an approved mounting bracket.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 13 January 2016 Resolved
46 CFR 177.900 Deck rails must withstand a pointload of 200lbs applied in any direction. Hand rail loose on port side aft superstructure. Repair to original condition.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 January 2016
Resolution: Wasted screws were replaced with new; attending MI verified rails are in accordance with cite.
Fire Fighting › Miscellaneous Items › Insulation (Penetration of Oil/Oil Vapors)
Issued 13 January 2016 Resolved
46 CFR 177.405 (a) The general construction of the vessel must be such as to minimize fire hazards insofar as it is reasonable and practicable.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 January 2016
Resolution: Owner replaced waste/missing heat shields in engine room to include underside of wooden exhaust panel that was replaced with new due to delamination. Corrective action made to the satisfaction of attending MI.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 13 January 2016 Resolved
46 CFR 184.710 A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. Multiple medicines found expired. Replace with new.
Due 13 February 2016
Resolved 19 January 2016
Resolution: Expired medicines replaced and kit found IAW regulatory cite.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 13 January 2016 Resolved
46 CFR 16.260/401: Company policy not established and must be displayed.
Action required: 705 - Other - as specified
Due 22 February 2016
Resolved 15 March 2016
Resolution: Company submitted policy IAW cite. See copy of policy attached under Documents.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 13 January 2016 Resolved
46 CFR 177.405 Exhaust ventilation found not operational-unable to close due to line used to close/open exhaust cover is a fishing line.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 January 2016
Resolution: Corrective action taken by owner and tested by attending MI to be operational.
Engineering › Steering Gear System › Rudder
Issued 13 January 2016 Resolved
46 CFR 182.610: Grounding wire for rudder posts wasted.
Due 13 February 2016
Resolved 19 January 2016
Resolution: Wasted grounding wire replaced with new to the satisfaction of attending MI.
Lifesaving › Lifebuoys › Serviceable
Issued 14 June 2012 Resolved
Replace ring buoy.
Due 21 June 2012
Resolved 22 June 2012
Resolution: Ring buoy replaced.
Communications › Alarms/Indicators › Bilge Alarm
Issued 14 June 2012 Resolved
Label high water bilge alarms.
Due 21 June 2012
Resolved 22 June 2012
Resolution: Alarms labeled.
Communications › Radio Communications › EPIRB
Issued 14 June 2012 Resolved
Mark expiration date on EPIRB hydrostatic release.
Due 21 June 2012
Resolved 24 June 2012
Resolution: Expiration date marked.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 13 December 2011 Resolved
Provide documentation of annual servicing of installed FFE and portable fire extinguishers.
Action required: 705 - Other - as specified
Due 22 December 2011
Resolved 22 December 2011
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 13 December 2011 Resolved
Place on board a complete first aid kit.
Action required: 705 - Other - as specified
Due 22 December 2011
Resolved 22 December 2011
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 13 December 2011 Resolved
Place a "DO NOT DISCHARGE WITHIN 3 MILES OF SHORE" IWO sewage overboard.
Action required: 705 - Other - as specified
Due 22 December 2011
Resolved 22 December 2011
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 13 December 2011 Resolved
Remove or repair installed commode. Toilet does not seal properly to prevent sewage fumes from entering bathroom.
Action required: 705 - Other - as specified
Due 22 December 2011
Resolved 22 December 2011
Engineering › Bilge Water Management System › Pump
Issued 13 December 2011 Resolved
Stern bilge pump must have an manual operation mode.
Action required: 705 - Other - as specified
Due 22 December 2011
Resolved 22 December 2011
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 23 November 2010 Resolved
Ensure member of crew has a Marine Radio Operator Permit.
Due 23 November 2010
Resolved 31 May 2011
Resolution: Proof provided as required.
Electrical › Electrical Distribution System (service) › Overcurrent Device
Issued 23 November 2010 Resolved
Remove unprotected (no circuit protection) wire from battery (red wire ~14awg) to terminal block in machinery space and ensure all circuits are protected.
Due 30 November 2010
Resolved 30 November 2010
Resolution: Wire removed from battery. New 12awg wire routed to main panel, fused w/6amp fuse. Per crew, circuit was for mach space bilge high water alarm. Tested sat.
Electrical › Electrical Distribution System (service) › Wiring
Issued 23 November 2010 Resolved
Replace non-marine wires from Fireboy pressure switch to control module with correct marine grade wire/cable (i.e. UL Boat).
Due 30 November 2010
Resolved 30 November 2010
Operations/Management › Drills/Instruction › Fire
Issued 18 November 2010 Resolved
New master not knowledgeable of vessels safety equipment (fire, lifesaving) and procedures.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 November 2010
Resolved 19 November 2010
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 November 2010 Resolved
Re-hang wires over the SME. Wires moved to gain access to mach space vent.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 November 2010
Resolved 19 November 2010
Engineering › Fuel Oil Storage/Transfer System › Manifold
Issued 18 November 2010 Resolved
Remove diesel fuel soaked sorbents from bilge. Cause determined to be damaged fuel/water separator bowl, make proper permanent repairs.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 November 2010
Resolved 22 November 2010
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 2 November 2010 Resolved
Secure for sea the refer in aft salon.
Action required: 705 - Other - as specified
Resolved 18 November 2010
Engineering › Fuel Oil Service System › Vent Pipe
Issued 2 November 2010 Resolved
Ensure P/S fuel tank vents have flame screens. Ensure the port fuel tank vents outside of space (crew unable to find vent or where vent hose led to).
Due 16 November 2010
Resolved 18 November 2010
Communications › Alarms/Indicators › Bilge Alarm
Issued 2 November 2010 Resolved
Repair E/R bilge high water alarm (visual).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 November 2010
Lifesaving › Hand Flares › Quantity
Issued 2 November 2010 Resolved
Ensure vsl has correct number of distress signals. (missing 1 smoke or hand flare)
Due 16 November 2010
Resolved 18 November 2010
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 November 2010 Resolved
Remove/properly terminate all dead-ended wires under helm. Ensure all connections are proper.
Due 16 November 2010
Resolved 19 November 2010
Communications › Public Address System › Loudspeaker
Issued 2 November 2010 Resolved
Install/repair PA system.
Due 16 November 2010
Resolved 18 November 2010
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 27 October 2010 Resolved
Replace port navlight due to excessive wastage.
Action required: 705 - Other - as specified
Resolved 18 November 2010
Construction/Loadline › Hull › Longitudinal Frame
Issued 27 October 2010 Resolved
Aft deck supports (4 total) installed improperly in lazarette. Make permanent attachment.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 2 November 2010
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 27 October 2010 Resolved
Bilge pumps installed with no permament mount. Mount all bilge pumps to hull.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 2 November 2010
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 27 October 2010 Resolved
Install bilge pump to space forward of machinery space.
Action required: 705 - Other - as specified
Resolved 2 November 2010
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 27 October 2010 Resolved
Floating water light missing clip. Install clip.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 2 November 2010
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 27 October 2010 Resolved
Replace retroreflective material as necessary to as new.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 2 November 2010
Documentation › Certificates/Documents › Certificate of Inspection
Issued 27 October 2010 Resolved
Certificate of Inspection not mounted in plain view. Mount COI.
Action required: 705 - Other - as specified
Resolved 2 November 2010
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 27 October 2010 Resolved
No proof of enrollment in drug testing program. Provide documentation for all employees in safety sensitive positions.
Action required: 705 - Other - as specified
Resolved 19 November 2010
Stability › Weathertight Integrity › General
Issued 27 October 2010 Resolved
Forward and aft weather hatches require labeling as escape hatches on inner portion of the respective compartments.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 2 November 2010
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 27 October 2010 Resolved
Proove proper EAP training for Supervisor and crewmembers.
Action required: 705 - Other - as specified
Due 28 November 2010
Resolved 31 May 2011
Resolution: Proof provided as required.
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 27 October 2010 Resolved
Provide evidence of pre-employment testing for employees.
Action required: 705 - Other - as specified
Due 28 November 2010
Resolved 18 November 2010
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 27 October 2010 Resolved
Provide policy statement for Drug and Alcohol Program.
Action required: 705 - Other - as specified
Due 28 November 2010
Resolved 31 May 2011
Resolution: Provided proof as required.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 27 October 2010 Resolved
Repair aft cockpit door gunwale.
Action required: 705 - Other - as specified
Resolved 2 November 2010
Stability › Weathertight Integrity › General
Issued 27 October 2010 Resolved
Repair aft weathertight window/hatch.
Action required: 705 - Other - as specified
Resolved 2 November 2010
Personnel › Certificates/Documents/Licenses › License, Master
Issued 27 October 2010 Resolved
Ensure vessel is in command of someone with proper license endorsement. Master only had inland waters 50GT master's license.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 November 2010
Documentation › Certificates/Documents › FCC SSL
Issued 27 October 2010 Resolved
Correct FCC safety radio certificate to 5 year validity vice 6 year validity. (14March2008 to 14March2013)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 November 2010
Documentation › Logs/Records › Logbook (official)
Issued 27 October 2010 Resolved
Provide passenger manifest for 24OCT2010 voyage where vessel log shows vessel was carrying 55 passengers. Vessel only certificated for 47 passengers at the time.
Action required: 705 - Other - as specified
Resolved 2 November 2010
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 27 October 2010 Resolved
Ensure a child Type1 PFD is provided for every child less than 90 pounds. Vessel had only 7 child PFDs onboard, 2 were condemned during the inspection. Vessel log showed numerous dates within past two months where more than 7 children were onboard.
Action required: 705 - Other - as specified
Resolved 2 November 2010
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 27 October 2010 Resolved
Ensure all crewmembers are enrolled in a drug testing program. Current master reportedly is in previous employer's program but has no documentation for sharing crew members. Temporary master is not listed in company's drug testing program. Deck hand during inspection has never been enrolled or pre-employment drug tested.
Action required: 705 - Other - as specified
Resolved 19 November 2010
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 27 October 2010 Resolved
Repair/provide portable bilge pump.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 November 2010
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 27 October 2010 Resolved
Determine why vessel does not have a collision bulkhead. Submit written proposal for collision bhd installation meeting 46 CFR 179.310 (new T) or 46 CFR 171.085 (old-S). Install collision bhd per approved submitted plans. Vsl restricted to protected waters (LBS) until corrected.
Action required: 705 - Other - as specified
Resolved 18 November 2010
Operations/Management › Vessel Safety Management › Emergency Preparedness
Issued 27 October 2010 Resolved
Label emergency exits.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 November 2010
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 27 October 2010 Resolved
Label hailing port on stern.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 November 2010
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 27 October 2010 Resolved
Install vent closures for machinery space.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 November 2010
Electrical › Electrical Distribution System (service) › Wiring
Issued 27 October 2010 Resolved
Properly hang electrical wires in lazarette.
Action required: 705 - Other - as specified
Resolved 2 November 2010
Engineering › Steering Gear System › Linkage
Issued 27 October 2010 Resolved
Tighten steering connecting arm-to-rudder bolts.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 November 2010
Stability › Watertight Integrity › General
Issued 27 October 2010 Resolved
Make lazarette hatch watertight.
Action required: 705 - Other - as specified
Resolved 2 November 2010
Operations/Management › Drills/Instruction › Not Conducted
Issued 27 October 2010 Resolved
Complete drills to satisfaction of attending Coast Guard marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 November 2010
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 27 October 2010 Resolved
Install impingement bowl on starboard engine fuel filter.
Action required: 705 - Other - as specified
Due 7 December 2010
Resolved 8 December 2010
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 27 October 2010 Resolved
Repair fuel leak on port fuel tank return line.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 November 2010
Fire Fighting › Fixed Halon Fire Extinguishing System › Quantity of Halon
Issued 27 October 2010 Resolved
Conduct annual service on mahinery space pre-engineered fire fighting system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 November 2010
Construction/Loadline › Structures › Deck Plating
Issued 27 October 2010 Resolved
Ensure deck supports on port side of machinery space are properly fastened.
Action required: 705 - Other - as specified
Resolved 2 November 2010
Electrical › Electric Supply System (service) › Battery Installation
Issued 27 October 2010 Resolved
Install covers on batteries.
Action required: 705 - Other - as specified
Resolved 18 November 2010
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 27 October 2010 Resolved
Repair/replace Fireboy audible indicator.
Due 16 November 2010
Resolved 18 November 2010
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 11 January 2010 Resolved
Show proof of drug consortium.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 January 2010
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 11 January 2010 Resolved
Proof test pre-engineered fire suppression system and show proof of fire system servicing.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 January 2010
Resolution: Tested Sat!
Electrical › Electric Supply System (service) › Battery Charger
Issued 11 January 2010 Resolved
Replace missing alternator on starboard main engine.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 January 2010
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 11 January 2010 Resolved
Darken upper deck markings for maximum number of passengers as required by stability letter.
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 January 2010
Resolved 15 January 2010
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 11 January 2010 Resolved
Starboard nav light inop show proof of proper operation.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 January 2010
Navigation › Piloting/Steering › Marine Charts
Issued 11 January 2010 Resolved
Update charts.
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 January 2010
Resolved 15 January 2010
Navigation › Piloting/Steering › Coast Guard Light List
Issued 11 January 2010 Resolved
Show proof of navigational pubs to include: CG light list for Guam, current tide and current tables, US coast pilot for Guam, and CG Rules of the road.
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 January 2010
Resolved 15 January 2010
Engineering › Bilge Water Management System › Interface Detector
Issued 11 January 2010 Resolved
Show proof of operation of bilge high water alarms which are required in engine room, lazarette, and in any area with a through hull. Indicator should be audio and visually alarm at the control station.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 January 2010
Resolution: Tested all with SAT results!
Engineering › Diesel Engine (propulsion-electric) › Piping (exhaust)
Issued 11 January 2010 Resolved
Generator hose is crimped remove crimp in hose.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 January 2010
Resolution: Installed support hose; tested SSDG with SAT results.
Deck/Cargo › Holds/Tanks › Independent Tank
Issued 11 January 2010 Resolved
Cap off bottom fuel tank drain valve port side.
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 January 2010
Resolved 15 January 2010
Electrical › Electric Generation Source (service) › Grounding Conductor
Issued 11 January 2010 Resolved
Reconnect ground wire under port main engine aft.
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 January 2010
Resolved 15 January 2010
Fire Fighting › Means of Escape › Blocked
Issued 11 January 2010 Resolved
Secure cable/wire with metal hangers every 24-inches as required in engine room.
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 January 2010
Resolved 15 January 2010
Engineering › Fuel Oil Service System › Valve
Issued 11 January 2010 Resolved
Label fuel oil emergency shut off valves.
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 January 2010
Resolved 15 January 2010
Resolution: All labelled sat.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 11 January 2010 Resolved
Put chaffing pads on hoses as needed to prevent possible damage to pressure hoses.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 25 January 2010
Resolved 15 January 2010
Electrical › Electric Generation Source (service) › Grounding Conductor
Issued 11 January 2010 Resolved
Forward galley bilge ground wire needs to be connected.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 January 2010
Resolved 15 January 2010
Resolution: Vessel owner removed.
Engineering › Bilge Water Management System › Pump
Issued 11 January 2010 Resolved
All automatic bilge pumps are required to have a visual indicator at the operation station. Show proof as required for all automatic bilge pumps.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 January 2010
Resolution: Tested SAT.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 9 July 2009 Resolved
Clean-remove excessive oil/water in mach space.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 July 2009
Resolved 13 July 2009
Resolution: Vessels reps cleaned bilges with sat rsults.
Fire Fighting › Structural Fire Protection - General › Fiber Reinforced Plastic
Issued 9 July 2009 Resolved
Re-attach all falling insulation on mach space overhead. Insulation hanging on M/E exhaust.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 July 2009
Resolved 13 July 2009
Resolution: vessels reps repaired sagging insulation.
Fire Fighting › Fixed Gas Fire Extinguishing System › Quantity of Gas
Issued 9 July 2009 Resolved
Install correct size pre-engineered fire system in mach space. COI lists 600ft3 system, currently a 200ft3 system is installed.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 July 2009
Resolved 13 July 2009
Resolution: Vessels reps had installed an approved size 1000 firboy unit until the new size 600 arrives on Island.
Engineering › Sea-water System (primary cooling) › Piping
Issued 9 July 2009 Resolved
Ensure all hoses are double hose clamped.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 July 2009
Resolved 13 July 2009
Resolution: Vessels reps installed double clamps through out the r/w system.
Electrical › Electrical Distribution System (service) › Cable
Issued 27 January 2009 Resolved
Repair /remove all open wire in FWD void under galley.
Due 28 February 2009
Resolved 3 February 2009
Resolution: Completed satisfactory repairs.
Electrical › Electrical Distribution System (service) › Cable
Issued 27 January 2009 Resolved
Remove wire nuts on death end wires in engine room.
Due 28 February 2009
Resolved 3 February 2009
Electrical › Lighting (service) › Lighting Fixture
Issued 27 January 2009 Resolved
Repair loose light fixtures FWD & AFT in engine room.
Due 28 February 2009
Resolved 3 February 2009
Resolution: Completed a satisfactory repairs.
Electrical › Lighting (service) › Grounding Conductor
Issued 27 January 2009 Resolved
Repair loose ground wires in engine room.
Due 28 February 2009
Resolved 3 February 2009
Resolution: Completed a satisfactory repairs.
Construction/Loadline › Hull › Hull Plating
Issued 27 January 2009 Resolved
Provide a repair proposal for hull damage in steering room. Water was observed entering the space from outside below water line.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 February 2009
Resolution: Completed satisfactory repairs. Damage deck was initially thought to be a major hull damage; however, after further inspection by the operator, the damage was over void filled with fresh water.
Construction/Loadline › Structures › Deck Plating
Issued 27 January 2009 Resolved
Repair a damaged deck in AFT cabin
Due 28 February 2009
Resolved 30 April 2009
Construction/Loadline › Structures › Deck Plating
Issued 27 January 2009 Resolved
Repair a fractured bilge access cover FWD cabin.
Due 28 February 2009
Resolved 3 February 2009
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 27 January 2009 Resolved
Replace missing exhuast hose clamp in steering room starboard exhaust.
Due 28 February 2009
Resolved 3 February 2009
Engineering › Sea-water System (primary cooling) › Piping
Issued 27 January 2009 Resolved
Replace missing hose clamp on Generator salt water system.
Due 28 February 2009
Resolved 3 February 2009
Engineering › Sea-water System (primary cooling) › Pump
Issued 27 January 2009 Resolved
Replace a worned salt water pump diven belt on both main diesel engine.
Due 28 February 2009
Resolved 3 February 2009
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 27 January 2009 Resolved
Repair/tight loose port main engine rear outboard foundation bolt.
Due 28 February 2009
Resolved 3 February 2009
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 27 January 2009 Resolved
Trouble shoot & repair fuel leak on port fuel tank in engine room.
Due 28 February 2009
Resolved 30 April 2009
Engineering › Steering Gear System › Linkage
Issued 27 January 2009 Resolved
Replace a worn out tie rod and bolt.
Due 28 February 2009
Resolved 3 February 2009
Engineering › Lubricating Oil Service System › Piping
Issued 27 January 2009 Resolved
Repair lube oil leak on port engine lube oil cooler outlet piping.
Due 28 February 2009
Resolved 6 February 2009
Engineering › Lubricating Oil Service System › Hose
Issued 27 January 2009 Resolved
Replace C-clamp on oil line for both main engine transmision selector valve.
Due 28 February 2009
Resolved 3 February 2009
Construction/Loadline › Hull › Hull Plating
Issued 27 January 2009 Resolved
Remove PCV nipple on through hull fittings.
Due 28 February 2009
Resolved 3 February 2009
Resolution: Replaced with metal plug.
Construction/Loadline › Hull › Hull Plating
Issued 27 January 2009 Resolved
Replace PCV plug on through hull fittings that are not been used.
Due 28 February 2009
Resolved 3 February 2009
Resolution: Replaced with metal plug.
Lifesaving › Hand Flares › Not on Board
Issued 27 January 2009 Resolved
Purchase 6 ( not expired) new hand flares for night time.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 February 2009
Resolution: Purchased 6 new flares.
Electrical › Lighting (service) › Lighting Fixture
Issued 27 January 2009 Resolved
Repair AFT cabin light fixture.
Due 28 February 2009
Resolved 30 April 2009
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 27 January 2009 Resolved
Provide a update report from Reliance to include [name withheld].
Due 28 February 2009
Resolved 6 February 2009
Electrical › Electric Supply System (service) › Battery Installation
Issued 27 October 2005 Resolved
Install battery box in Fwd accomodation space.
Due 10 November 2005
Resolved 10 November 2005
Engineering › Bilge Water Management System › Not Operational
Issued 27 October 2005 Resolved
Remove unused auto bilge switch in aft steering compartment.
Due 10 November 2005
Resolved 10 November 2005
Construction/Loadline › Penetrations › Gasket
Issued 27 October 2005 Resolved
Replace gasket material on steering compartment hatch.
Due 10 November 2005
Resolved 10 November 2005
Communications › Radio Communications › VHF Radiotelephone
Issued 27 October 2005 Resolved
Provide valid station license.
Due 10 November 2005
Resolved 10 November 2005
Navigation › Piloting/Steering › Magnetic Compass
Issued 27 October 2005 Resolved
Repair/replace compass light.
Due 10 November 2005
Resolved 11 November 2005
Communications › Audible Communications › Horn/Whistle
Issued 27 October 2005 Resolved
Repair vessel's horn.
Due 10 November 2005
Resolved 10 November 2005
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 29 October 2004 Resolved
Prove operation of anchor light.
Action required: 705 - Other - as specified
Due 16 November 2004
Resolved 18 November 2004
Fire Fighting › Fire Bucket › Availability
Issued 29 October 2004 Resolved
Place 3 fire buckets on board the vessel.
Action required: 705 - Other - as specified
Due 9 November 2004
Resolved 18 November 2004
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 29 October 2004 Resolved
Repair stbd engine heat exchanger.
Action required: 705 - Other - as specified
Due 9 November 2004
Resolved 18 November 2004
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 29 October 2004 Resolved
Replace reflective tape on lifejackets.
Action required: 705 - Other - as specified
Due 9 November 2004
Resolved 18 November 2004
Navigation › Piloting/Steering › Magnetic Compass
Issued 29 October 2004 Resolved
Prove operation of compass light.
Action required: 705 - Other - as specified
Due 9 November 2004
Resolved 18 November 2004
Communications › Audible Communications › Horn/Whistle
Issued 29 October 2004 Resolved
Prove operation of ship's horn.
Action required: 705 - Other - as specified
Due 9 November 2004
Resolved 18 November 2004
Documentation › Certificates/Documents
Issued 23 December 2003 Resolved
Provide valid radio safety certificate.
Due 23 January 2004
Resolved 7 January 2004
Lifesaving › Lifebuoys
Issued 23 December 2003 Resolved
Replace ring life buoy.
Due 23 January 2004
Resolved 7 January 2004
Communications › Radio Communications
Issued 23 December 2003 Resolved
Replace hydro-static release on EPIRB. LEGACY COMPONENT DESC: EPIRB
Due 6 January 2004
Resolved 7 January 2004
Accommodation/Occupational Safety › Medical/First Aid
Issued 23 December 2003 Resolved
Provide complete first aid kit.
Due 23 January 2004
Resolved 7 January 2004
Documentation › Markings/Placards
Issued 23 December 2003 Resolved
Provide emergency broadcast placard.
Due 23 January 2004
Resolved 7 January 2004
Electrical › Lighting (service)
Issued 23 December 2003 Resolved
Replace lighting covers on aft deck.
Due 23 January 2004
Resolved 7 January 2004
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 23 December 2003 Resolved
Re-stensil emergency escape hatch.
Due 23 January 2004
Resolved 7 January 2004
Engineering
Issued 23 December 2003 Resolved
Replace clamps on stbd exhaust and stbd sea strainers.
Due 23 January 2004
Resolved 7 January 2004
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 23 December 2003 Resolved
Provide proof of servicing for portable fire extinguishers. LEGACY COMPONENT DESC: Service
Due 23 January 2004
Resolved 7 January 2004
Documentation › Certificates/Documents
Issued 3 October 2002 Resolved
PROVIDE A CURRENT CERTIFICATE OF DOCUMENTATION. LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Due 3 November 2002
Resolved 23 October 2002
Resolution: Document on board.
Lifesaving › Buoyant Apparatus
Issued 3 October 2002 Resolved
REPLACE CURRENT BUOYANT APPARATUS WITH A EPIRB, LIFE FLOAT OR INFLATABLE BUOYANT APPARATUS.
Condition: Improper/Lack of Maintenance
Due 2 November 2002
Resolved 23 October 2002
Resolution: Vessel owner has installed an EPIRB.
Accommodation/Occupational Safety › Medical/First Aid
Issued 3 October 2002 Resolved
PLACE INVENTORY OF FIRST AID KIT CONTENTS IN SAME. LEGACY COMPONENT DESC: Medicine Chest
Condition: Unknown
Due 2 November 2002
Resolved 23 October 2002
Resolution: Inventory placed.
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 3 October 2002 Resolved
HAVE ALL PORTABLE FIRE EXTINGUISHERS SERVICED.
Due 2 November 2002
Resolved 23 October 2002
Resolution: All extinguishers serviced.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 3 October 2002 Resolved
PROVE PROPER OPERATION OF ENGINE SHUTDOWNS AND OVER-RIDES (FIXED F/F SYSTEM).
Due 2 November 2002
Resolved 23 October 2002
Resolution: Operates properly.
Construction/Loadline › Penetrations
Issued 3 October 2002 Resolved
INSTALL CHECK VALVE IN WAY OF SEWAGE OVERBOARD DISCHARGE LINE.
Due 2 November 2002
Resolved 23 October 2002
Resolution: Check valve installed.
Electrical › Electric Supply System (service)
Issued 3 October 2002 Resolved
PROPERLY MARK BATTERY DISCONNECT SWITCH TO SHOW "ON-OFF" POSITION. LEGACY COMPONENT DESC: Battery Conductor
Due 2 November 2002
Resolved 23 October 2002
Resolution: Marked.
Communications › Internal Communications System
Issued 3 October 2002 Resolved
INSTALL PUBLIC ADDRESS SYSTEM.
Due 2 November 2002
Resolved 23 October 2002
Resolution: Installed and functioning.
Navigation › Piloting/Steering
Issued 3 October 2002 Resolved
PROVIDE A CURRENT COPY OF NAVIGATION RULES. LEGACY COMPONENT DESC: Inland Navigation Rules
Due 2 November 2002
Resolved 23 October 2002
Resolution: On board.
Documentation
Issued 3 October 2001 Resolved
Provide proof of enrollment of all crewmembers in a random drug testing program.
Condition: Unknown
Due 29 October 2001
Resolved 29 October 2001
Accommodation/Occupational Safety
Issued 3 October 2001 Resolved
Several windows in passenger accomodation spaces contain multiple fractures. Owner says cause is passenger leaning against window. Replace/repair IAW regulations.
Condition: Unknown
Due 29 October 2001
Resolved 29 October 2001
Lifesaving
Issued 18 May 2000 Resolved
Conduct quarterly man overboard and fire fighting drills and make proper log enteries for same.
Condition: Unknown
Due 18 May 2000
Resolved 18 May 2000
Navigation
Issued 18 May 2000 Resolved
Obtain and make corrections to Apra Harbor Chart.
Condition: Unknown
Due 18 May 2000
Resolved 18 May 2000
Lifesaving
Issued 6 October 1999 Resolved
Provide one oar for vessels lifefloat.
Condition: Unknown
Due 17 October 1999
Resolved 6 October 1999
Electrical
Issued 6 October 1999 Resolved
Use pressure type connectors for splice for aft cabin bilge pump.
Condition: Unknown
Due 17 October 1999
Resolved 6 October 1999
Navigation
Issued 6 October 1999 Resolved
Provide chart #81408 which covers entire operating area.
Condition: Unknown
Due 17 October 1999
Resolved 6 October 1999
Electrical
Issued 6 October 1999 Resolved
Support all cables and wires with metal supports not more than 24" apart.
Condition: Unknown
Due 17 October 1999
Resolved 6 October 1999
Accommodation/Occupational Safety
Issued 6 October 1999 Resolved
Remove, or provide technical data for vessel's hot water heater.
Condition: Unknown
Due 17 October 1999
Resolved 6 October 1999
Lifesaving
Issued 6 October 1999 Resolved
Mark location for storage of childs lifejackets.
Condition: Unknown
Due 17 October 1999
Resolved 6 October 1999
Unknown
Issued 6 October 1999 Resolved
All crew are required to attend drug and alcohol awareness and recognition training.
Condition: Unknown
Due 6 October 1999
Resolved 6 October 1999
Construction/Loadline
Issued 6 October 1999 Resolved
Double hose clamp all bilge pump hoses for aft cabin bilge pump.
Condition: Unknown
Due 17 October 1999
Resolved 6 October 1999
Unknown
Issued 6 October 1999 Resolved
Prove compliance with required drug testing program.
Condition: Unknown
Due 17 October 1999
Resolved 6 October 1999
Navigation
Issued 6 October 1999 Resolved
Provide operators permit for VHF-FM radio.
Condition: Unknown
Due 17 October 1999
Resolved 6 October 1999
Electrical
Issued 6 October 1999 Resolved
Remove light fixture from aft shower.
Condition: Unknown
Due 17 October 1999
Resolved 6 October 1999
Electrical
Issued 6 October 1999 Resolved
Remove dead end wires from overhead in aft cabin.
Condition: Unknown
Due 17 October 1999
Resolved 6 October 1999
Documentation
Issued 25 August 1999 Resolved
Attach current document sticker to vessel's Certificate of Documentation.
Condition: Unknown
Due 25 August 1999
Resolved 25 August 1999
Navigation
Issued 25 August 1999 Resolved
Prove operation of stern light.
Condition: Unknown
Due 25 August 1999
Resolved 25 August 1999
Lifesaving
Issued 25 August 1999 Resolved
Replace expired flares and smoke signal devices prior to the carriage of passengers for hire.
Condition: Unknown
Due 25 August 1999
Resolved 25 August 1999
Construction/Loadline
Issued 9 May 1999 Resolved
Provide proof of installation of bilge hi-level alarm & indicators meeting 46 CFR 182.530 for each space with a through hull fitting, machinery space,or space with a non-watertight hatch. Vessel COI will be revoked & vessel limited to nmt 6 passengers, without proof of installation by 10JUN99.
Condition: Unknown
Due 9 May 1999
Resolved 9 May 1999
Fire Fighting
Issued 9 May 1999 Resolved
Provide proof of purchase of a fixed fire extinguishing system, meeting requirements of 46 CFR 181.400, for each space containing an internal combustion engine. Vessel COI will be revoked and vessel limited to not more than 6 passengers without proof of purchase by 28MAY99.
Condition: Unknown
Due 9 May 1999
Resolved 9 May 1999
Accommodation/Occupational Safety
Issued 24 September 1998 Resolved
Provide a suitable ladder for the forward emergency escape hatch.
Condition: Unknown
Due 24 September 1998
Resolved 24 September 1998
Engineering
Issued 24 September 1998 Resolved
Properly install exhaust lagging (insulation) on the port main diesel engine exhaust piping up to the point of water injection.
Condition: Unknown
Due 24 September 1998
Resolved 24 September 1998
Electrical
Issued 24 September 1998 Resolved
Properly install a battery emergency disconnect switch between the battery and the generator starter.
Condition: Unknown
Due 24 September 1998
Resolved 24 September 1998
Engineering
Issued 24 September 1998 Resolved
Renew in kind the deteriorated exhaust hose on the generator. The hose shall be double clamped at each end.
Condition: Unknown
Due 24 September 1998
Resolved 24 September 1998
Navigation
Issued 24 September 1998 Resolved
Provide current charts for the vessel's operating area, navigation rules ofthe road pub and tide/current tables.
Condition: Unknown
Due 24 September 1998
Resolved 24 September 1998
Construction/Loadline
Issued 24 September 1998 Resolved
Provide documentation from the vessel's manufacturer indicating what type of resin was used in vessel construction. Vessel must comply with the fireequivalencies of NVIC 8-87 if the vessel was constructed with non fire retardant resin.
Condition: Unknown
Due 24 September 1998
Resolved 24 September 1998
Lifesaving
Issued 24 September 1998 Resolved
Conduct emergency drills with all crew members and log in accordance with 46 CFR 185.
Condition: Unknown
Due 24 September 1998
Resolved 24 September 1998
Lifesaving
Issued 24 September 1998 Resolved
Provide a suitable first aid kit in accordance with 46 CFR 184.710.
Condition: Unknown
Due 24 September 1998
Resolved 24 September 1998
Lifesaving
Issued 24 September 1998 Resolved
Conduct weekly, monthly and annual life saving equipment inspections in accordance with 46 CFR 185.
Condition: Unknown
Due 24 September 1998
Resolved 24 September 1998
Navigation
Issued 24 September 1998 Resolved
Permanently reinforce (backing plate) the deteriorated rudder actuator foundation.
Condition: Unknown
Due 24 September 1998
Resolved 24 September 1998
Electrical
Issued 24 September 1998 Resolved
Remove or properly dead-end in a junction box astray wiring located behind the 110 volt receptacle on the forward engine room bulkhead.
Condition: Unknown
Due 24 September 1998
Resolved 24 September 1998
Electrical
Issued 24 September 1998 Resolved
Properly dead-end in a junction box astray wiring located in the vicinity of the Fireboy Auto Engine Shutdown Control box.
Condition: Unknown
Due 24 September 1998
Resolved 24 September 1998
Documentation
Issued 24 September 1998 Resolved
Provide a valid FCC marine operators permit for each person who operates the VHF radio.
Condition: Unknown
Due 24 September 1998
Resolved 24 September 1998
Construction/Loadline
Issued 24 September 1998 Resolved
Renew defective hose clamps on the port and stbd propeller shaft stuffing tube hoses. Each hose shall have four stainless steel clamps installed.
Condition: Unknown
Due 24 September 1998
Resolved 24 September 1998
Engineering
Issued 24 September 1998 Resolved
Double clamp the stbd fuel fill hose at the tank connection.
Condition: Unknown
Due 24 September 1998
Resolved 24 September 1998
Electrical
Issued 24 September 1998 Resolved
Replace the 110 volt receptacle located on the engine room forward bulkheadwith a proper marine grade receptacle and box.
Condition: Unknown
Due 24 September 1998
Resolved 24 September 1998
Lifesaving
Issued 24 September 1998 Resolved
Identify remote cable and re-attach, if necessary, cable located at forwardbulkhead of engine room.
Condition: Unknown
Due 24 September 1998
Resolved 24 September 1998
Lifesaving
Issued 24 September 1998 Resolved
Re-attach the Fireboy Auto Engine Shutdown Control box to the engine room bulkhead.
Condition: Unknown
Due 24 September 1998
Resolved 24 September 1998
Engineering
Issued 24 September 1998 Resolved
Renew in kind deteriorated cooling water hoses on main diesel engines and coolers.
Condition: Unknown
Due 24 September 1998
Resolved 24 September 1998
Accommodation/Occupational Safety
Issued 24 September 1998 Resolved
Provide hatches which can be opened/closed from both sides of the hatch forthe forward and aft emergency escape hatches.
Condition: Unknown
Due 24 September 1998
Resolved 24 September 1998
Electrical
Issued 24 September 1998 Resolved
Re-secure capacitor to the washdown pump located in the engine room.
Condition: Unknown
Due 24 September 1998
Resolved 24 September 1998
Construction/Loadline
Issued 24 September 1998 Resolved
Double clamp the discharge hose connections on the wash down pump.
Condition: Unknown
Due 24 September 1998
Resolved 24 September 1998
Accommodation/Occupational Safety
Issued 24 September 1998 Resolved
Provide locking device for each MSD overboard valve and post a warning signat each valve (keep valve closed within 3 miles of shore).
Condition: Unknown
Due 24 September 1998
Resolved 24 September 1998
Lifesaving
Issued 24 September 1998 Resolved
Replace the defective retro-reflective tape on six adult PFDs.
Condition: Unknown
Due 24 September 1998
Resolved 24 September 1998
Lifesaving
Issued 24 September 1998 Resolved
Provide watertight, bright in color container for the distress signals.
Condition: Unknown
Due 24 September 1998
Resolved 24 September 1998
Lifesaving
Issued 24 September 1998 Resolved
Post radio emergency broadcast placard and emergency instruction checklist.
Condition: Unknown
Due 24 September 1998
Resolved 24 September 1998
Lifesaving
Issued 24 September 1998 Resolved
Properly install 12 foot pendants (festooned) on the buoyant apparatus and the lifefloat.
Condition: Unknown
Due 24 September 1998
Resolved 24 September 1998
Construction/Loadline
Issued 24 September 1998 Resolved
Renew as original the rotten decking in the forward and aft salons.
Condition: Unknown
Due 24 September 1998
Resolved 24 September 1998
Construction/Loadline
Issued 24 September 1998 Resolved
Provide suction strainer and adequate length suction and discharge hoses for the portable hand bilge/fire pump.
Condition: Unknown
Due 24 September 1998
Resolved 24 September 1998
Lifesaving
Issued 4 November 1997 Resolved
Demonstrate to the satisfaction of the OCMI that drug testing program meetsrequirements of 46 CFR 16.
Condition: Unknown
Due 4 November 1997
Resolved 4 November 1997
Electrical
Issued 9 October 1997 Resolved
Provide second emergency flashlight per 46 CFR 183.430.
Condition: Unknown
Due 9 October 1997
Resolved 9 October 1997
Construction/Loadline
Issued 9 October 1997 Resolved
Permanently wire bilge pump in lazerrette per 46 CFR 183.340.
Condition: Unknown
Due 9 October 1997
Resolved 9 October 1997
Construction/Loadline
Issued 9 October 1997 Resolved
Renew lazerrete bilge pump float switch.
Condition: Unknown
Due 9 October 1997
Resolved 9 October 1997
Construction/Loadline
Issued 9 October 1997 Resolved
Renew deteriorated lazerrete hatch cover gasket per 46 CFR 179.369.
Condition: Unknown
Due 9 October 1997
Resolved 9 October 1997
Electrical
Issued 9 October 1997 Resolved
Replace missing main deck light cover.
Condition: Unknown
Due 9 October 1997
Resolved 9 October 1997
Fire Fighting
Issued 9 October 1997 Resolved
Recharge or replace discharged Type B:C Size 1 fire extinguisher on stbd side aft deck.
Condition: Unknown
Due 9 October 1997
Resolved 9 October 1997
Engineering
Issued 9 October 1997 Resolved
Replaced damaged and corroded fuel tank vent flame screens with 30 x 30 mesh per 46 CFR 182.450.
Condition: Unknown
Due 9 October 1997
Resolved 9 October 1997
Lifesaving
Issued 9 October 1997 Resolved
Secure bitter end of anchor cable to prevent loss during deployment.
Condition: Unknown
Due 9 October 1997
Resolved 9 October 1997
Construction/Loadline
Issued 9 October 1997 Resolved
Provide intake hose for portable hand pump.
Condition: Unknown
Due 9 October 1997
Resolved 9 October 1997
Lifesaving
Issued 9 October 1997 Resolved
Master not aware of stability requirements. Master shall determine vessel's compliance with stability letter prior to vessel's departure from dock per 46 CFR 185.315.
Condition: Unknown
Due 9 October 1997
Resolved 9 October 1997
Lifesaving
Issued 9 October 1997 Resolved
Renew lifeline pendants on Jim-Buoy 48" x 48" x 9" buoyant apparatus to standards of 46 CFR 160.010.
Condition: Unknown
Due 9 October 1997
Resolved 9 October 1997
Lifesaving
Issued 9 October 1997 Resolved
Post PFD donning instructions per 46 CFR 185.516.
Condition: Unknown
Due 9 October 1997
Resolved 9 October 1997
Lifesaving
Issued 9 October 1997 Resolved
Refasten aft deck ladder steps.
Condition: Unknown
Due 9 October 1997
Resolved 9 October 1997
Lifesaving
Issued 9 October 1997 Resolved
Reinstall cabin window securing dogs.
Condition: Unknown
Due 9 October 1997
Resolved 9 October 1997
Lifesaving
Issued 9 October 1997 Resolved
Renew Jim-Buoy 63" x 37" x 9" buoyant apparatus to standards of 46 CFR 160.10.
Condition: Unknown
Due 9 October 1997
Resolved 9 October 1997
Lifesaving
Issued 9 October 1997 Resolved
Replace existing lanyards between buoyant apparatus' and water lights with ones at least 18 feet in length.
Condition: Unknown
Due 9 October 1997
Resolved 9 October 1997
Lifesaving
Issued 9 October 1997 Resolved
Demonstrate operation of ring buoy light.
Condition: Unknown
Due 9 October 1997
Resolved 9 October 1997
Lifesaving
Issued 9 October 1997 Resolved
Provide sixty foot line for ring buoy.
Condition: Unknown
Due 9 October 1997
Resolved 9 October 1997
Navigation
Issued 9 October 1997 Resolved
Demonstrate operation of compass light per 46 CFR 184.402.
Condition: Unknown
Due 9 October 1997
Resolved 9 October 1997
Construction/Loadline
Issued 2 October 1996 Resolved
Make necessary repairs to deteriating deck in aft cabin.
Condition: Unknown
Due 2 October 1996
Resolved 2 October 1996
Lifesaving
Issued 2 October 1996 Resolved
Repair or replace ring bouy that is splitting at seams.
Condition: Unknown
Due 2 October 1996
Resolved 2 October 1996
Lifesaving
Issued 2 October 1996 Resolved
Stow weak link with line attached under canister holding line.
Condition: Unknown
Due 2 October 1996
Resolved 2 October 1996
Fire Fighting
Issued 2 October 1996 Resolved
Obtain one more B-II fire extinguisher for engineroom, stow near access to engineroom.
Condition: Unknown
Due 2 October 1996
Resolved 2 October 1996
Construction/Loadline
Issued 2 October 1996 Resolved
Provide handle to manualy operated fixed engineroom bilge pump.
Condition: Unknown
Due 2 October 1996
Resolved 2 October 1996
Construction/Loadline
Issued 2 October 1996 Resolved
Provide hand operated bilge/fire pump.
Condition: Unknown
Due 2 October 1996
Resolved 2 October 1996
Documentation
Issued 2 October 1996 Resolved
Obtain FCC Communications Act Safety Radiotelephony Certificate.
Condition: Unknown
Due 2 October 1996
Resolved 2 October 1996
Lifesaving
Issued 2 October 1996 Resolved
Replace all expired smoke and flard pyrotecnic signaling devices.
Condition: Unknown
Due 2 October 1996
Resolved 2 October 1996
Construction/Loadline
Issued 2 October 1996 Resolved
Replace missing access cover plate on fwd cabin/anchor chain locker bulkhead.
Condition: Unknown
Due 2 October 1996
Resolved 2 October 1996
Engineering
Issued 26 April 1996 Resolved
Double clamp all sea water cooling water lines.
Condition: Unknown
Due 26 April 1996
Resolved 26 April 1996
Electrical
Issued 26 April 1996 Resolved
Prove satisfactory operation of vessels generator.
Condition: Unknown
Due 26 April 1996
Resolved 26 April 1996
Engineering
Issued 26 April 1996 Resolved
Clear access to stbd engine emergency fuel cutoff valves.
Condition: Unknown
Due 26 April 1996
Resolved 26 April 1996
Deck/Cargo
Issued 26 April 1996 Resolved
Prove operation of anchor windlass.
Condition: Unknown
Due 26 April 1996
Resolved 26 April 1996
Navigation
Issued 26 April 1996 Resolved
Prove operation of port running light.
Condition: Unknown
Due 26 April 1996
Resolved 26 April 1996
Lifesaving
Issued 26 April 1996 Resolved
Repair "cracks" in bouyant apparatus.
Condition: Unknown
Due 26 April 1996
Resolved 26 April 1996
Lifesaving
Issued 26 April 1996 Resolved
Install proper sized weak link on bouyant apparatus.
Condition: Unknown
Due 26 April 1996
Resolved 26 April 1996
Fire Fighting
Issued 26 April 1996 Resolved
Service engineroom fixed halon system.
Condition: Unknown
Due 26 April 1996
Resolved 26 April 1996
Lifesaving
Issued 26 April 1996 Resolved
Remove and replace deteriated bouyant apparatus.
Condition: Unknown
Due 26 April 1996
Resolved 26 April 1996
Construction/Loadline
Issued 26 April 1996 Resolved
Reinstall missing "manhole" cover for chain locker.
Condition: Unknown
Due 26 April 1996
Resolved 26 April 1996
Engineering
Issued 26 April 1996 Resolved
Repair inoperative port engine bridge tach.
Condition: Unknown
Due 26 April 1996
Resolved 26 April 1996
Electrical
Issued 26 April 1996 Resolved
Install generator starting battery.
Condition: Unknown
Due 26 April 1996
Resolved 26 April 1996
Documentation
Issued 26 April 1996 Resolved
Obtain FCC required safety inspection for radiotelephone.
Condition: Unknown
Due 26 April 1996
Resolved 26 April 1996
Accommodation/Occupational Safety
Issued 26 April 1996 Resolved
Repair door handle main deck door, port side.
Condition: Unknown
Due 26 April 1996
Resolved 26 April 1996
Accommodation/Occupational Safety
Issued 26 April 1996 Resolved
Lock shut all Marine Sanitation Device overboard discharge valves.
Condition: Unknown
Due 26 April 1996
Resolved 26 April 1996
Lifesaving
Issued 26 April 1996 Resolved
Mark the proper number and type of lifejackets in their locations.
Condition: Unknown
Due 26 April 1996
Resolved 26 April 1996
Lifesaving
Issued 26 April 1996 Resolved
Obtain waterlight for ring bouy.
Condition: Unknown
Due 26 April 1996
Resolved 26 April 1996
Lifesaving
Issued 26 April 1996 Resolved
Attach bouyant apparatus to existing line with weak link.
Condition: Unknown
Due 26 April 1996
Resolved 26 April 1996
Fire Fighting
Issued 26 April 1996 Resolved
Install B-I portable extinguisher on bridge.
Condition: Unknown
Due 26 April 1996
Resolved 26 April 1996
Engineering
Issued 9 October 1990 Resolved
PROVIDE A MEANS OF SECURING THE MAIN ENGINES FROM THE AFT CONTROL STATION AS REQUIRED BY 46 CFR 179.10-29
Condition: Unknown
Due 9 October 1990
Resolved 9 October 1990

Casualty record · 7

1 December 2007Routine · role: Involved in a Marine Casualty · 1 dead · activity 3113776
8 July 2009Routine · role: Involved in a Marine Casualty · activity 3529796
26 August 2009Routine · role: Involved in a Marine Casualty · activity 3577787
3 March 2011Routine · role: Involved in a Marine Casualty · activity 3958697
25 June 2011Routine · role: Involved in a Marine Casualty · activity 4060067
5 November 2011Routine · role: Involved in a Marine Casualty · activity 4184482
26 January 2013Routine · role: Involved in a Marine Casualty · activity 4532398
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.