Records from 2007 to 2026. Most recent: inspection, 9 April 2026.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 18 March 2025
Resolved
U.S. Coast Pilot and CG Light List were outdated. Provide a copy of up to date publications and ensure on board at all times.
46 CFR 185.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2025
Resolved 19 March 2025
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 March 2025
Resolved
Portable fire extinguishers must be located so that they are clearly visible and readily accessible from the space being protected. The installation and location must be to the satisfaction of the Officer in Charge, Marine Inspection. The aft compartment's portable fire extinguisher was not mounted.
46 CFR 181.520
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2025
Resolved 19 March 2025
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 26 April 2022
Resolved
EPIRB registration is expired. 46CFR180.64
Action required: 10 - Deficiency Rectified
Resolved 26 April 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 April 2022
Resolved
Ring Buoy Floating Water Light Battery is expired. 46CFR180.70
Action required: 10 - Deficiency Rectified
Resolved 26 April 2022
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 26 April 2022
Resolved
Pre-Engineered (Fireboy) extinguishing systems manual operation was disable by the installation of the servicing pin at the bottle and the manual pull handle being secured in a way to prevent operation of handle. 46CFR181.420(2)
Action required: 10 - Deficiency Rectified
Resolved 26 April 2022
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 26 April 2022
Resolved
Identified loose rail attachment points on the port and starboard side of the vessel around the mid ship area and port handle on the aft ladder. 46CFR177.900
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2022
Resolved 31 May 2022
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 April 2022
Resolved
Emergency instructions and Radio Operations placards were worn and illegible and require renewal. 46CFR185.510
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2022
Resolved 31 May 2022
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 April 2022
Resolved
Forward Emergency Escape marking needs to be renewed. 46CFR177.500
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2022
Resolved 31 May 2022
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 26 April 2022
Resolved
Vessel does not have a log book on-board. 46CFR185.728
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2022
Resolved 31 May 2022
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 26 May 2021
Resolved
Port main engine alarming on operator's station.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 May 2021
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 6 May 2021
Resolved
Your vessel must undergo an annual inspection within 3 months before or after each anniversary date. Vessel missed annual inspection. 46 CFR 176.500(b)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 June 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 24 August 2020
Resolved
46 CFR 177.1020: Each window and its means of attachment to the hull or deckhouse, must be capable of withstanding the maximum load from wave and wind conditions. Repair or replace cracked starboard side window in passenger accommodation space to as original.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 September 2020
Resolved 14 January 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 24 August 2020
Resolved
46 CFR 177.900(b): Deck rails must be designed and constructed to withstand a point load of 200 pounds applied at any point in any direction. Repair broken starboard side deck rail to as original.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 September 2020
Resolved 14 January 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 August 2020
Resolved
46 CFR 182.520(e)(3): The pump is permanently mounted. Secure strainer for submersible electrical bilge pump in engine room compartment to bilge and properly attach bilge pump to strainer.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 January 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 24 August 2020
Resolved
46 CFR 182.100: All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from machinery failure and personnel injury. Repair hydraulic leak in aft steering.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 January 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 August 2020
Resolved
46 CFR 182.604(h): Each life jacket must be marked with Type I retro-reflective material approved in 46 CFR 164.018. Replace deteriorated retro-reflective tape on 9 x adult and 5 x children life jackets with new. Vessel is restricted to carrying no more than 38 passengers and no children until number of life jackets inspected with damaged/deteriorated retro-reflective tape are replaced with new to the satisfaction of the attending MI.
Action required: 705 - Other - as specified
Resolved 14 January 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 August 2020
Resolved
46 CFR 185.604: The number and identification of the items stowed inside and their sizes, must be marked in clearly legible letters and numbers for life jackets. Visibly mark locations where adult and children life jackets are stored.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 January 2021
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 13 February 2020
Resolved
46 CFR 15.401(a): It was reported by MSST HONO that the operator on SI SIRENA did not have in possession his USCG MMD credential while vessel was carrying passengers for Pending proof of a valid USCG MMD credential or operator in possession of a USCG MMD credential with appropriate tonnage and route, vessel is prohibited from carrying passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 February 2020
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 1 November 2019
Resolved
46 CFR 181.420: Pre-engineered fixe gas fire extinguishing system found not in compliance with manufacturer's instructions. Fusible element missing inside high temperature glass. Vsl rep to replace discharge head with new or entire system in accordance with manufacturer's specifications.
Action required: 705 - Other - as specified
Resolved 14 February 2020
Resolution: New inkind pre-engineered fire extinguishing system from Fireboy installed and inspected by 3rd party.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Other (MARPOL Annex IV)
Issued 1 November 2019
Resolved
33 CFR 151.59:Replace missing placard for prohibiting discharge of sewage within 3 miles from shore.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2019
Resolved 20 November 2019
Resolution: Placard posted IWO MSD overboard valve.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 November 2019
Resolved
46CFR 180.71: Total of 17 adult life jackets to be replaced with new, USCG approved Type 1. Life jackets inspected with multiple tears that penetrate through outerlayer exposing inner core. Vessel is reduced to carrying no more than 32 adult passengers.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 November 2019
Resolved 4 November 2019
Resolution: Adult life jackets with tears replaced with new USCG Type I.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 November 2019
Resolved
46 CFR 180.78: Missing signs where to show where life jackets for adult and children are stowed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 November 2019
Resolution: Signs posted with indication arrows for adult/child life jacket locations.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 November 2019
Resolved
46 CFR 182.465: Openings for port and starboard engine room ventilation above engine room compartment is blocked with new wood and sheet metal preventing airflow across the back of the engine to the front. The ventilation system should sufficiently move air to control temperature in all areas of the engine room. Repair to as original.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 November 2019
Resolved 15 November 2019
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 1 November 2019
Resolved
46 CFR 181.420: Manual pull cable for activiting Fireboy inside the forward passenger cabin to be relocated to the operating station to prevent passengers from accidentally pulling cable. Vsl owner reported to USCG that passengers will play with the cable or remove the pin to keep as a souvenir.
Action required: 705 - Other - as specified
Due 30 December 2020
Resolved 7 June 2021
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 November 2019
Resolved
46 CFR 177.405(f): Replace missing non-combustible receptacles on deck and in forward washroom.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 November 2019
Resolved 20 November 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 7 May 2019
Resolved
Pending satisfactory completion of annual inspection for 2019YR, vessel is prohibited from operating with passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 November 2019
Stability › Watertight Integrity › Coaming
Issued 6 February 2018
Resolved
46 CFR 179.360: Replace watertight gasket for steering room hatch cover with new.
Action required: 705 - Other - as specified
Due 15 February 2018
Resolved 13 February 2018
Fire Fighting › Means of Escape › Escape Route Signs
Issued 6 February 2018
Resolved
46 CFR 185.606: Remark faded emergency exit sign in forward cabin.
Action required: 705 - Other - as specified
Due 15 February 2018
Resolved 13 February 2018
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 6 February 2018
Resolved
46 CFR 180.70: Replace battery with new for ring buoy float light; vessel is restricted to daylight operations pending proof of new battery.
Action required: 705 - Other - as specified
Due 15 February 2018
Resolved 13 February 2018
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 6 February 2018
Resolved
46 CFR 176.25-50: Remove or properly cap off dead end wire below operator station.
Action required: 705 - Other - as specified
Due 15 February 2018
Resolved 13 February 2018
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 6 February 2018
Resolved
46 CFR 180.25-15: Designated storage locations for child life jackets must be marked.
Action required: 705 - Other - as specified
Due 15 February 2018
Resolved 13 February 2018
Fire Fighting › Remote Fuel Shutoff › General
Issued 6 February 2018
Resolved
46 CFR 176.25-50: Install chaffing guards for fuel shutoff pull cables; cables penetrate through sheet metal attached to engine room overhead.
Action required: 705 - Other - as specified
Due 15 February 2018
Resolved 16 March 2018
Navigation › Piloting/Steering › Magnetic Compass
Issued 6 February 2018
Resolved
46 CFR 184.402(c): Prove proper operation of compass light; restricted to daylight operations pending corrective action.
Action required: 705 - Other - as specified
Due 15 February 2018
Resolved 6 March 2018
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 6 February 2018
Resolved
46 CFR 185.604: Remark ring buoy with vessel's name and port in 2" block capital letters.
Action required: 705 - Other - as specified
Due 15 February 2018
Resolved 13 February 2018
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 6 February 2018
Resolved
46 CFR 182.05-1: Submit proof of new tachometer for starboard main engine and estimated date of delivery.
Action required: 705 - Other - as specified
Due 15 February 2018
Resolved 16 March 2018
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 6 February 2018
Resolved
46 CFR 16: Submit proof of enrollment for random drug testing for crewmembers employed in safety sensitive position.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 February 2018
Documentation › Certificates/Documents › Certificate of Inspection
Issued 31 January 2018
Resolved
46 CFR 176.404: Subsequent inspections for COI renewal 3 months overdue. Vessel's COI expired on 18OCT2017.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 February 2018
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 20 January 2017
Resolved
46 CFR 177.405(f): Garbage waste receptacle must be of a non-combustible type.
Due 27 January 2017
Resolved 31 January 2017
Personnel › Training › First Aid/CPR
Issued 20 January 2017
Resolved
NAVIC 1-91: Provide proof of first/aid CPR training for 50% of crew required on board during operations.
Due 28 February 2017
Resolved 1 May 2017
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 20 January 2017
Resolved
46 CFR 183.200(b): Remove all dead end wires in forward void where MSD tank is located.
Due 27 January 2017
Resolved 31 January 2017
Communications › Radio Communications › VHF Radiotelephone
Issued 20 January 2017
Resolved
47 CFR 80.13: MMSI not programmed into VHF radio.
Due 27 January 2017
Resolved 15 February 2017
Fire Fighting › Means of Escape › Escape Route Signs
Issued 20 January 2017
Resolved
46 CFR 177.500: Means of escape must be marked and clear of obstruction.
Due 27 January 2017
Resolved 31 January 2017
Engineering › Bilge Water Management System › Pump
Issued 20 January 2017
Resolved
46 CFR 185.602(g): Replace non-approved bilge pump with UL approved type, UL113, in forward void.
Due 28 February 2017
Resolved 28 February 2017
Operations/Management › Passenger Operations › Safety Orientation
Issued 20 January 2017
Resolved
46 CFR 185.602(g): Clearly mark passenger capacity for upper deck.
Due 27 January 2017
Resolved 31 January 2017
Fire Fighting › Fire Bucket › Capacity
Issued 20 January 2017
Resolved
46 CFR 181.610: Fire buckets must be of 2.5 gallon type.
Due 27 January 2017
Resolved 31 January 2017
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 20 January 2017
Resolved
46 CFR 183.200(b): Repair electrical outlet in forward washroom to as original or prove power secured to prevent from being accidentally used.
Due 27 January 2017
Resolved 31 January 2017
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 13 January 2016
Resolved
Missing bracket for II fire extinguisher, per 46 CFR 181.500.
Action required: 705 - Other - as specified
Due 13 February 2016
Resolved 19 January 2016
Resolution: Owner replaced A-II fire extinguisher with a B-I, extinguisher with an approved mounting bracket.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 13 January 2016
Resolved
46 CFR 177.900 Deck rails must withstand a pointload of 200lbs applied in any direction. Hand rail loose on port side aft superstructure. Repair to original condition.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 January 2016
Resolution: Wasted screws were replaced with new; attending MI verified rails are in accordance with cite.
Fire Fighting › Miscellaneous Items › Insulation (Penetration of Oil/Oil Vapors)
Issued 13 January 2016
Resolved
46 CFR 177.405 (a) The general construction of the vessel must be such as to minimize fire hazards insofar as it is reasonable and practicable.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 January 2016
Resolution: Owner replaced waste/missing heat shields in engine room to include underside of wooden exhaust panel that was replaced with new due to delamination. Corrective action made to the satisfaction of attending MI.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 13 January 2016
Resolved
46 CFR 184.710 A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. Multiple medicines found expired. Replace with new.
Due 13 February 2016
Resolved 19 January 2016
Resolution: Expired medicines replaced and kit found IAW regulatory cite.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 13 January 2016
Resolved
46 CFR 16.260/401: Company policy not established and must be displayed.
Action required: 705 - Other - as specified
Due 22 February 2016
Resolved 15 March 2016
Resolution: Company submitted policy IAW cite. See copy of policy attached under Documents.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 13 January 2016
Resolved
46 CFR 177.405 Exhaust ventilation found not operational-unable to close due to line used to close/open exhaust cover is a fishing line.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 January 2016
Resolution: Corrective action taken by owner and tested by attending MI to be operational.
Engineering › Steering Gear System › Rudder
Issued 13 January 2016
Resolved
46 CFR 182.610: Grounding wire for rudder posts wasted.
Due 13 February 2016
Resolved 19 January 2016
Resolution: Wasted grounding wire replaced with new to the satisfaction of attending MI.