MAURY USCG vessel records Sign in
← All vessels

KRITON

KRITON is a 1990 freight ship. The Coast Guard has recorded 22 inspections since 1990, most recently in May 2006, along with 21 deficiencies and 2 operational controls.

Records from 1990 to 2006. Most recent: inspection, 13 May 2006.

Built
1990
Last inspected
13 May 2006
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8906834 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
354059
Flag
SINGAPORE
—
Maury page id
psix-354059

Inspections, by type

…with no type recorded16
Years with a record 12 calendar years (1990–2006)
The 22 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 20 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it13807 - Regulatory (Subpart C or D), Net Ton
13807 - Convention (Subpart B), Net Ton
23274 - Regulatory (Subpart C or D), Gross Ton
23274 - Convention (Subpart B), Gross Ton
42007 - Dead Weight, Ton
48754 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 22

13 May 2006 Type not recorded
No type recorded · Station Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2648653
12 May 2006 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2647305
12 May 2006 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2647898
8 May 2005 MARPOL Annex I Examination · Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2350885
7 July 2004 NPV Safety Exam
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2125161
9 June 2004 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2094310
17 November 2003 Annual Inspection · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1950318
28 March 2001 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 289001
12 August 1999 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 191644
12 August 1999 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 764236
12 June 1999 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 429525
2 June 1999 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 429263
10 January 1997 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 399435
30 October 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 371803
30 October 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 866981
18 August 1994 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 369866
18 August 1994 MARPOL Annex V Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1173929
21 April 1993 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 674548
16 April 1993 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 520631
14 October 1992 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 518857
17 October 1991 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 482170
3 October 1990 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 339604

Deficiency record · 21

Fire Fighting › Emergency Fire Pumps › Pressure
Issued 12 May 2006 Resolved
When emergency fire pump is energized it fails to provide pressure to any of the fire hoses.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 May 2006
Resolved 17 May 2006
Resolution: Flag attested to proper operation of #2 fire pump.
Engineering › Steering Gear System › Motor
Issued 12 May 2006 Resolved
Rudder will stick when hard over at 35 degrees to starboard side.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 18 May 2006
Resolved 17 May 2006
Resolution: Flag state attested to proper operation and USCG inspectors observed proper operation of pump.
Construction/Loadline › Hull › Weld
Issued 12 May 2006 Resolved
Hand rail supports on starboard side outside of No.5 cargo hold are wasted at the bottom near the deck.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 May 2006
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 12 May 2006 Resolved
Numerous buckets in engine room full of waste oil and oily rags and excess fuel/lube oil in way off generators.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 May 2006
Resolved 17 May 2006
Resolution: Removd buckets form engine rom.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 12 May 2006 Resolved
Vessel did not maintain the condition of the HFO settling tank vent and return lines in accordance with SOLAS 74/Ch.1/Reg 11.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 May 2006
Resolved 17 May 2006
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 12 May 2006 Resolved
Wasted platform for main fire pump to be repaired in accordance with ILO-147
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 May 2006
Resolution: Repaired platform.
Engineering › Freshwater System (jacketwater cooling) › Valve
Issued 12 May 2006 Resolved
Excessive Jacket water leaks for #3 and #4 cylinders need to be repaired IAW SOLAS 74/Ch.1/Reg.II
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 May 2006
Resolved 17 May 2006
Engineering › Fuel Oil Service System › Valve
Issued 12 May 2006 Resolved
Supply line valve from HFO purifiers to engine in way of excessive leak must be repaired IAW SOLAS 74/Ch.1.Reg.II. Also the oil saturated insulation around the HFO lines and filters needs to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 May 2006
Resolved 17 May 2006
Resolution: Supply lines renewed and insulation was ordered to be replaced at next port of call.
Electrical › Lighting (service) › Lighting Fixture
Issued 12 May 2006 Resolved
Multiple light globes and guards missing in machinery spaces, wet spaces, crew's berthing and food storage spaces. Deficiency to be rectified with in 30 days.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2006
Resolved 17 May 2006
Resolution: Electrician made roper replacements to globes and guards.
Engineering › Sea-water System (primary cooling) › Piping
Issued 9 June 2004 Resolved
Steam leak near diesel generator #1. Leading from boiler. Provide proof of repair.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 July 2004
Resolution: Received receipt of repair by fax.
Engineering › Fuel Oil Service System › Piping
Issued 9 June 2004 Resolved
Fuel oil leak at inlet of diesel generator #1 and #2. Provide proof of repair.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 July 2004
Resolution: Received receipt of repair by fax.
Engineering › Fuel Oil Service System › Piping
Issued 9 June 2004 Resolved
Fuel oil leak at main engine. Provide proof of repair.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 July 2004
Resolution: Received receipt of repair by fax.
Navigation › Piloting/Steering › Magnetic Compass
Issued 9 June 2004 Resolved
Provide current servicing report for magnetic compass.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 July 2004
Resolution: Received receipt of repair by fax.
Fire Fighting
Issued 2 June 1999 Resolved
PRIOR TO NEXT U.S. PORT, ENSURE FIRE SCREEN DOORS CLOSE PROPERLY IN ENGINE ROOM ESCAPE TRUNK AND MAIN HOUSE STAIR TOWER. HAVE CLASS VERIFY PROPER OPERATION AND PROVIDE REPORT TO U.S. COAST GUARD.
Condition: Unknown
Due 3 June 1999
Resolved 3 June 1999
Electrical
Issued 2 June 1999 Resolved
PRIOR TO NEXT U.S. PORT, REPAIR LIGHT FIXTURE AND REPLACE MISSING GLOBE IN FORWARD BOSUN'S LOCKER.
Condition: Unknown
Due 14 June 1999
Resolved 14 June 1999
Fire Fighting
Issued 2 June 1999 Resolved
PRIOR TO DEPARTURE PROVE PROPER OPERATION OF EMERGENCY FIRE PUMP TO CLASS SOCIETY AND PROVIDE REPORT TO MSO TAMPA.
Condition: Unknown
Due 3 June 1999
Resolved 3 June 1999
Lifesaving
Issued 18 August 1994 Resolved
LIFE RAFTS IMPROPERLY RIGGED, SEA PAINTERS TIED TO VESSEL'S HULL WITH NO WEAK LINKS.
Condition: Unknown
Due 25 August 1994
Resolved 25 August 1994
Navigation
Issued 3 October 1990 Resolved
CHART NO. 18521 NOT CORRECTED UP TO DATE.
Condition: Unknown
Due 25 August 1994
Resolved 25 August 1994
Navigation
Issued 3 October 1990 Resolved
CHART NO. 18523 NOT CORRECTED UP TO DATE.
Condition: Unknown
Due 25 August 1994
Resolved 25 August 1994
Navigation
Issued 3 October 1990 Resolved
CHART NO. 18524 NOT CORRECTED UP TO DATE.
Condition: Unknown
Due 25 August 1994
Resolved 25 August 1994
Navigation
Issued 3 October 1990 Resolved
CHART NO. 18526 NOT CORRECTED UP TO DATE.
Condition: Unknown
Due 25 August 1994
Resolved 25 August 1994

Ownership record