MAURY USCG vessel records Sign in
← All vessels

MEGAN STAR

MEGAN STAR is a 1981 freight ship. The Coast Guard has recorded 22 inspections since 1990, most recently in October 2008, along with 22 deficiencies — 1 with no resolution recorded — and 1 operational control.

Records from 1990 to 2008. Most recent: inspection, 1 October 2008.

Built
1981
Last inspected
1 October 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

354198
Flag
PANAMA
—
Maury page id
psix-354198

Inspections, by type

…with no type recorded19
Years with a record 13 calendar years (1990–2008)
The 22 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it1619 - Regulatory (Subpart C or D), Net Ton
2798 - Regulatory (Subpart C or D), Gross Ton
4700 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 22

1 October 2008 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3336265
3 February 2003 Annual Inspection · Ballast Water Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1739045
28 November 2001 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 295870
22 September 2000 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 282339
8 March 1999 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 426465
20 January 1999 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 424575
10 December 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 410722
15 September 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 407988
24 June 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 392582
23 February 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 388350
29 August 1995 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 382204
6 January 1995 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 373882
17 August 1994 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 369356
7 January 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 363702
16 April 1993 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 357680
7 January 1993 Uninspected Other
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1463066
11 May 1992 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 674645
30 April 1992 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 504624
16 April 1992 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 350114
16 October 1991 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 346699
22 March 1991 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 461795
4 September 1990 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 339131

Deficiency record · 22

Operations/Management › Equipment Service/Testing
Issued 31 January 2003 Resolved
Replace expired hydrostatic release for EPIRB, prior to departure. LEGACY COMPONENT DESC: EPIRB
Action required: 705 - Other - as specified
Resolved 6 February 2003
Resolution: New hydrostatic release purchased from ATLAS Ship Services, Inc. invoice #887 dtd 4Feb03. Hydrostatic released installed to the satisfaction of attending class surveyor.
Construction/Loadline › Hull
Issued 31 January 2003 Resolved
Noted torn and wasted framing and side shell protection in #2 cargo hold. Also holes between cargo hold #1 & #2. Make repairs prior to departure to the satisfaction of an attending flag rep. LEGACY COMPONENT DESC: Side Shell
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 6 February 2003
Resolution: Torn and wasted framing and side shell protection in #2 cargo hold and holes between cargo hold #1 & #2 have been temporarly repaired to the satisfaction of the attending flag surveyor. Permanent repairs to be completed in drydock.
Lifesaving › Launching Appliances
Issued 31 January 2003 Resolved
Noted wire rope certificate for life boats dated 1997. No record of renewal. LEGACY COMPONENT DESC: Falls
Action required: 705 - Other - as specified
Resolved 6 February 2003
Resolution: Vessel purchased new wire ropes for both life boats and installed to the satisfaction of the attendingFlag surveyor. Wire rope purchased from Atlas Ship Services, Inc. on invoice #886 dtd 3Feb03.
Navigation › Piloting/Steering
Issued 31 January 2003 Resolved
Replace outdated 1993 Coast Pilot prior to departure. Noted to be currently corrected but nearly unsuable. LEGACY COMPONENT DESC: US Coast Pilot
Action required: 705 - Other - as specified
Resolved 6 February 2003
Resolution: New US Coast Pilot 5, 2003, 30th Edition (Gulf of Mexico, Puerto Rico and Virgin Islands) purchased from Atlas Ship Services, INC. on invoice #886 dtd 3Feb02.
Construction/Loadline › Penetrations
Issued 31 January 2003 Resolved
Noted gasket missing for battery room door. Also noted workshop door between cargo holds #1 and #2 unable to close due to warpage.. LEGACY COMPONENT DESC: Gasket
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 6 February 2003
Resolution: Vsl supplied and installed new gasket for battery room''''s watertight door. Vsl also purchased 3 watertight doors and were installed to the structure between cargo holds by Bender Shipbuilding & Repair Co., Inc. Invoice #14829F dtd 4Feb03.
Lifesaving › Inflatable Liferafts
Issued 31 January 2003 Resolved
Replace hydrostatic releases for liferafts that expired 01FEB03 prior to departure. LEGACY COMPONENT DESC: Hydrostatic Release Unit
Action required: 705 - Other - as specified
Resolved 6 February 2003
Resolution: Vessel purchased new hyrostatic releases for liferafts and installed to the satisfaction of the attending Flag surveyor. Releases were purchased from Atlas Ship Services, Inc. dtd 3Feb03.
Lifesaving › Lifeboat Equipment
Issued 31 January 2003 Resolved
Provide sail for portside unpowered lifeboat, prior to departure.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 February 2003
Resolution: Vessel made a new sail for the unpowered life boat port side to the satisfaction of the attending Flag surveyor.
Lifesaving › Lifeboat
Issued 31 January 2003 Resolved
Noted temporary repairs to lifeboat handrails. Flag/Class to make recommendations for permanent repairs. Also provide reflective tape. LEGACY COMPONENT DESC: Handholds/Handrails
Action required: 705 - Other - as specified
Resolved 6 February 2003
Resolution: Temporary repairs to life boat handrails to be permanently fixed in drydock. Reflective tape was provided and placed on life boats.
Construction/Loadline › Hull
Issued 31 January 2003 Resolved
Noted large cement box in engine room on hull next to hydro tank. Flag Rep. to inspect and make recommendation for repair. LEGACY COMPONENT DESC: Hull Plating
Action required: 705 - Other - as specified
Resolved 6 February 2003
Resolution: Cement box in Engine room portside between frames 18 and 21 to be repaired permanently in drydocking. Class surveyor attested to tempory repair (doubler plate).
Lifesaving › Lifejacket/PFD (General)
Issued 31 January 2003 Resolved
Provide whistles for all lifejackets prior to departure. LEGACY COMPONENT DESC: Whistles
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 6 February 2003
Resolution: Whistles for lifejackets were provided and placed on lifejackets to the satisfaction of the attendingflag rep. Whistles purchased from Atlas Ship Services, Inc. dtd 3Feb03.
Lifesaving › Lifebuoys
Issued 31 January 2003 Resolved
Replace at least (3) wasted life ring buoys prior to departure.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 6 February 2003
Resolution: Vessel purchased and replaced 3 wasted life ring buoys to the satisfaction of the attending Flag rep. Life ring buoys were purchased from Atlas Ship Services, Inc. dtd 3Feb03.
Engineering › Sea-water System (primary cooling)
Issued 31 January 2003 Resolved
Noted wasted saltwater service pump. Flag Rep. to address. LEGACY COMPONENT DESC: Pump
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 6 February 2003
Resolution: Temporary repairs made by ship''s crew. Working condition inspected by Flag rep. and attested too as being in proper operation on 6Feb02.
Documentation › Logs/Records
Issued 31 January 2003 No resolution recorded
Noted no shoreside disposal for plastics since 27JUN02. Noted clinkers in incinerator ash. No stored clinkers on board or ceciepts for disposal shoreside. Also noted incomplete garbage log book entries. Ship to provide LOU for $31.5, prior to departure. LEGACY COMPONENT DESC: Garbage Record keeping
Action required: 17 - Rectify deficiencies prior to departure
Resolution: Vessel provided a garbage disposal reciept show that the vessel had discharged garbage to shore while in the Port of Kingston, Jamaica dtd 27 Nov 02. Vessel was no longer required to provide Letter of Undertaking.
Personnel › Certificates/Documents/Licenses
Issued 31 January 2003 Resolved
Provide Panamanian licenses for all officers with exception of C.E. prior to departure. LEGACY COMPONENT DESC: STCW Endorsement
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 February 2003
Resolution: Panamanian Licenses for all officers were received on board 6Feb03.
Construction/Loadline
Issued 20 January 1999 Resolved
AFT CARGO HOLD COAMING IS CRACKED IN THE FORWARD STARBOARD CORNER, MAKE REPAIRS.
Condition: Unknown
Due 12 March 1999
Resolved 12 March 1999
Unknown
Issued 15 September 1997 Resolved
INADEQUATE/MISSING DISCHARGE CONTAINMENT FOR VESSEL'S BULK LUBE OIL FILL PIPES AND VENTS, PORT AND STARBOARD TANKS._x001C_ _x001C_ 33 CFR 155.320
Condition: Unknown
Due 10 December 1997
Resolved 10 December 1997
Lifesaving
Issued 15 September 1997 Resolved
PORT AND STARBOARD LIFE BOAT LIMIT SWITCHES INOPERATIVE._x001C_ _x001C_ SOLAS 74(UNAMENDED) REG III/36(k)
Condition: Unknown
Due 10 December 1997
Resolved 10 December 1997
Fire Fighting
Issued 17 August 1994 Resolved
Improper fire hose nozzles aboard. Adequate replacement nozzles purchased approved by class.
Condition: Unknown
Due 22 August 1994
Resolved 22 August 1994
Electrical
Issued 17 August 1994 Resolved
Lights in foc'sle missing protective covers.
Condition: Unknown
Due 22 August 1994
Resolved 22 August 1994
Fire Fighting
Issued 17 August 1994 Resolved
Emergency fire pump had inadequate pressure. Pump housing cleaned and resealed, the pump pressure increased from 1.5 Kg to 3.0 Kg. Solas requiredpressure is 2.1 Kg, existing vessel. Class attended vessel approved all repairs.
Condition: Unknown
Due 22 August 1994
Resolved 22 August 1994
Lifesaving
Issued 17 August 1994 Resolved
Watertight door, port side fwd cargo house, not sealing properly. Ship crewcorrected.
Condition: Unknown
Due 22 August 1994
Resolved 22 August 1994
Engineering
Issued 16 April 1992 Resolved
NO MECHANICAL MEANS OF CLOSING EACH DRAIN FOR DISCHARGE CONTAINMENT. NEEDEDA SCREW TYPE PLUG IN DISCHARGE CONTAINMENT.
Condition: Unknown
Due 7 May 1992
Resolved 7 May 1992

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.