← All vessels
VANGUARD
Passenger (Inspected) · Passenger Ship class · Built 1990s · USCG Southwest District (CGD-SW) · Other hulls named VANGUARD
VANGUARD is a 1990 passenger vessel (inspected). The Coast Guard has recorded 77 inspections since 1991, most recently in March 2025, along with 214 deficiencies, 1 operational control and 2 casualty investigations between 2006 and 2009.
Records from 1991 to 2025. Most recent: inspection, 13 March 2025.
- Built
- 1990
- Last inspected
- 13 March 2025
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 214 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 2 investigations · 2006–2009
Identity
968507
WDJ5807
354274
Flag
UNITED STATES
367161070
Maury page id
psix-354274
Inspections, by type
…with no type recorded9
Years with a record
32 calendar years (1991–2025)
The 77 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)64.8 ft × 19.2 ft × 8.0 ft
Registered tonnagegross 66 / net 53
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBY GLEN & RUTH GALBRAITH · OXNARD, CA, UNITED STATES · built 1990
Hull materialWood
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portOXNARD, CA
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 19 November 2025 · expires 30 November 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it66 - Simplified, Gross Ton
53 - Simplified, Net Ton
53 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDJ5807MMSI 367161070 · active · compulsorily equipped · granted 27 May 2017, expires 27 May 2027
WDD5619MMSI 367161070 · expired · compulsorily equipped · granted 17 January 2007, cancelled 25 March 2017
WCX4004MMSI not assigned · expired · compulsorily equipped · granted 15 April 1997, cancelled 16 June 2007 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 77
13 March 2025
COI Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 8087306
17 April 2024
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7896380
30 November 2023
Administrative Inspection · Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7831689
13 April 2023
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7650540
21 April 2022
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7411846
13 December 2021
Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7361071
18 November 2021
Administrative Inspection
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7353616
12 May 2021
Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7196337
13 April 2021
Damage Survey · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7157456
2 March 2020
Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6919322
5 September 2019
Hull Examination · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6805018
5 September 2019
In-Service Inspection · Administrative Inspection · Plan Review "T" Boat
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6862265
30 April 2019
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6671274
12 April 2018
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6388023
12 December 2017
Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6313639
29 November 2017
Administrative Inspection
Administrative · Navigation Center · Activity 6314792
16 March 2017
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6102216
9 March 2016
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5825788
5 November 2015
Deficiency Check · Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5758093
6 December 2011
Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 4275401
17 March 2010
COI Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3696014
24 February 2010
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3686026
6 May 2009
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3468698
24 June 2008
Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3246675
5 May 2008
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3199644
9 January 2008
Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3126663
9 May 2007
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2926763
28 July 2006
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2759788
27 April 2006
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2635904
15 September 2005
Damage Survey · Hull Examination · Construction Oversight
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2493531
13 April 2005
Deficiency Check · COI Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2334044
19 May 2004
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2072098
20 January 2004
Hull Examination · In-Service Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 1996307
5 June 2003
Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 1810616
7 May 2003
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 1788753
18 December 2002
Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 1721188
29 July 2002
Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 1655131
17 July 2002
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 1655077
25 October 2001
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1076058
13 June 2001
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1403418
18 March 2001
Examination of Repairs
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1429504
16 March 2001
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 27919
15 February 2001
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1432501
25 January 2001
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1056956
25 October 2000
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 664273
23 October 2000
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1425001
25 August 2000
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1421919
29 June 2000
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1051663
21 April 2000
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1361409
16 June 1999
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1420152
25 February 1999
Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1369045
10 January 1999
Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 789900
8 December 1998
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1397039
9 November 1998
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1375555
25 October 1998
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 152136
3 September 1998
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 797090
20 August 1998
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1458557
30 July 1998
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1131142
30 July 1998
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1364777
26 January 1998
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 784338
3 December 1997
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1437335
16 June 1997
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1110687
23 May 1997
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1105772
13 May 1997
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1406110
1 May 1996
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1394527
29 November 1995
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1355557
20 April 1995
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1360079
22 June 1994
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1171711
12 May 1994
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1419263
20 April 1994
Damage Survey
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 861524
19 April 1994
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 111419
7 December 1993
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1387435
9 June 1993
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1393960
1 March 1993
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1148656
22 June 1992
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 945404
10 June 1992
Re-Inspection · Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1410737
14 May 1991
Hull Examination · Initial Certification · Initial Construction-Excluding Oversight
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1252776
Deficiency record · 214
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 April 2024
Resolved
Waste receptacles. Unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle, waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom. Vessel has combustible waste receptacles on board the vessel. Replace combustible waste receptacles with metal or an approved non-combustible material IAW 46 CFR § 164.009.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 17 April 2024
Resolved
The Rules concerning shapes shall be complied with by day. Vessel is required to carry shapes for signaling purposes for restricted in ability to maneuver (ball, diamond, ball) and vessel not under command (ball, ball). Provide day shapes to the satisfaction of the attending marine inspector.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 17 April 2024
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. Burn gel was expired (7/22). Replace burn gel to the satisfaction of the attending marine inspector.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 13 April 2023
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules, except that a vessel of more than 19.8 meters (65 feet) in length must also have navigation lights that meet UL 1104, “Standards for Marine Navigation Lights,” or other standard specified by the Commandant. Port running light showed significant etching which degraded light visibility. Repair or replace light.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 21 April 2022
Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. Alcohol testing devices were not available on board the vessel. Provide approved and current testing devices.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 21 April 2022
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: (1) Charts of large enough scale to make safe navigation possible; (2) U.S. Coast Pilot or similar publication; (3) Coast Guard Light List; (4) Tide tables; and (5) Current tables, or a river current publication issued by the U.S. Army Corps of Engineers or a river authority. Current nautical publications and charts were not available on board. Provide current publications and charts.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 April 2022
Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets and immersion suits. Identification of the items may be in words, or the appropriate symbols in IMO Resolution A.760(18) (incorporated by reference; see 46 CFR 175.600). Letters and numbers must be at least 50 millimeters (2 inches) high. Symbols must be at least 100 mm (4 inches) square. Markings were not accurate for current stowage of lifejackets. Provide accurate markings.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 21 April 2022
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. First aid kit was found with expired eye wash. Provide complete first aid kit with current contents.
12 - Dangerous Goods › N/A - No Subsystem › Dangerous goods / harmful substances in pack. form
Issued 18 November 2021
Resolved
No person may transport a hazardous material in commerce unless the hazardous material is transported in accordance with applicable requirements of this subchapter, or an exemption or special permit, approval, or registration issued under this subchapter or subchapter A of this chapter. Vessel transports hazardous material in the form of camp sotve fuel brought on by passengers. Vessel must fully comply with the applicable requirements of 49 CFR 171-176 or apply for a special permit under 49 CFR 107.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 April 2021
Resolved
Pilot house requires 10-B:C portable fire extinguisher, but was found with a 2-B:C extinguisher. Provide fire extinguisher of at least 10-B:C size for pilot house.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 13 April 2021
Resolved
Vessel's safety radio telephony certificate expired. Provide current certificate.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 April 2021
Resolved
Upper deck life ring buoy worn and degraded. Replace.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 13 April 2021
Resolved
First aid kit missing tourniquet. Provide compelte first aid kit that meets 46 CFR 160.041.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 13 April 2021
Resolved
Vessel did not log monthly fire extinguisher inspections. Log monthly fire extinguisher inspections.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 2 March 2020
Resolved
Provide current COD.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 2 March 2020
Resolved
Provide current FCC station certificate.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 March 2020
Resolved
Provide wire hangers every 24".
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 2 March 2020
Resolved
Provide updated pubs & charts.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 2 March 2020
Resolved
Label amount of pax authorized on upper deck.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 30 April 2019
Resolved
Provide complete and current first aid kit.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 30 April 2019
Resolved
Provide DSC VHF radio programmed with MMSI and GPS input.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 30 April 2019
Resolved
Provide current coast pilot and light list on board.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 30 April 2019
Resolved
Forepeak bilge valve not operable from outside the space.
Fire Fighting › Means of Escape › Blocked
Issued 12 December 2017
Resolved
Make all emergency escape hatches accessible from both sides.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 16 March 2017
Resolved
Relocate fireboy shut down control terminal outside of engine room.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 16 March 2017
Resolved
Repair forward hatch closure arm.
Construction/Loadline › Structures › Superstructure
Issued 16 March 2017
Resolved
Replace cracked window port aft accommodation space.
Documentation › Certificates/Documents › FCC SSL
Issued 16 March 2017
Resolved
Renew FCC SSL.
Electrical › Lighting (service) › Lighting Fixture
Issued 16 March 2017
Resolved
Install light cover in forward berthing.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 10 December 2015
Resolved
Install rail courses so that distance between qunwale/rail does not exceed 12".
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 17 March 2010
Resolved
Provide 16 Type I adult L/Js. Vessel ltd to no more than 68 adults (+9 persons <90 lbs) pending replacement.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 17 March 2010
Resolved
Update Coast Pilot & Light List
Fire Fighting › Ventilation Systems › Operating Controls
Issued 17 March 2010
Resolved
E/R vent closures: replace rope pulls with wire rope pulls.
Documentation › Markings/Placards › Warning Signs
Issued 17 March 2010
Resolved
E/R: label 120VAC panel exterior, and breakers.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 24 February 2010
Resolved
Provide adequate railing at top of ladder to upper deck in way of passenger entry way.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 6 May 2009
Resolved
Re-position mast head light to allow full 225 degree visibility.
Engineering › Fuel Oil Service System › Valve, Control
Issued 6 May 2009
Resolved
Adjust port aft fuel shut-off to ensure proper closure.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 6 May 2009
Resolved
Update USCG Light List
Navigation › Piloting/Steering › Coast Guard Light List
Issued 6 May 2008
Resolved
Update CG Light List
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 May 2008
Resolved
Hardwire battery charger in E/R. Remove old 110 receptacle, and if still desired, replace w/ covered receptacle.
Engineering › Fuel Oil Service System › Hose
Issued 6 May 2008
Resolved
Replace leaking fuel hose w/ end fitting, port side E/R.
Navigation › Collision/Grounding Avoidance › Day Shapes
Issued 6 May 2008
Resolved
Provide anchor day shape.
Engineering › Bilge Water Management System › Piping
Issued 6 May 2008
Resolved
Fwd storesbilge: replace hose connector in bilge line w/Pedro hose.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 6 May 2008
Resolved
Replace forepeak captive chain.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 9 January 2008
Resolved
Install additional railing course between gunwale and rail iaw 46 CFR 177.35-1(b).
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 9 May 2007
Resolved
Provide fire extinguisher service report.
Navigation › Piloting/Steering › US Coast Pilot
Issued 9 May 2007
Resolved
Provide current US coast pilot and light list for area.
Electrical › Electric Supply System (service) › Battery Installation
Issued 9 May 2007
Resolved
Provide battery box (w/ cover) for battery in pilot house.
Electrical › Electrical Distribution System (service) › Busway
Issued 9 May 2007
Resolved
Provide cover for electrical bus under pilot house.
Electrical › Electrical Distribution System (service) › Wiring
Issued 9 May 2007
Resolved
Remove excess and dead end electrical wires (under pilot house, e/r, laz).
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 9 May 2007
Resolved
Replace grabline on stbd life ring.
Lifesaving › Lifefloat › Markings
Issued 9 May 2007
Resolved
Stencil main deck life floats with carrying capacity (22 persons ea).
Operations/Management › Equipment Service/Testing › EPIRB
Issued 9 May 2007
Resolved
Mark name of vessel on epirb.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 9 May 2007
Resolved
Replace expired items in first aid kit.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 9 May 2007
Resolved
Repair stbd nav light.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 9 May 2007
Resolved
Repair lighting in crew quarters (port and stbd).
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 9 May 2007
Resolved
Replace cracked windows (port and stbd) in galley area.
Operations/Management › Drills/Instruction › Safety Orientation
Issued 9 May 2007
Resolved
Provide PFD doning instructions for passengers.
Engineering › Steering Gear System › Ram
Issued 9 May 2007
Resolved
Provide repair proposal for steering arm.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 9 May 2007
Resolved
Provide current Cert of Documentation.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 27 April 2006
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Navigation › Piloting/Steering › US Coast Pilot
Issued 27 April 2006
Resolved
Update Coast Pilot
Electrical › Electrical Distribution System (service) › Bus Bar Connection
Issued 27 April 2006
Resolved
Cover bus bar on bridge console or relocate below console.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 27 April 2006
Resolved
Remove 110V AC extension strip from bridge. If more receptacles necessary, submit wiring diagram for approval/installation.
Fire Fighting › Means of Escape › Doorways
Issued 27 April 2006
Resolved
Install closures operable from both sides on three emergency escape hatches.
Lifesaving › Lifefloat › Lifeline
Issued 27 April 2006
Resolved
Re-rig lifefloat pendant ties.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 27 April 2006
Resolved
Re-stencil lifejackets as necessary
Electrical › Electrical Distribution System (service) › Wiring
Issued 27 April 2006
Resolved
Terminate electrical wiring in galley, or re-install fixture.
Construction/Loadline › Structures › Ventilators
Issued 9 January 2006
Resolved
Install adequate ventilation for all compartments as discussed.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 9 January 2006
Resolved
Post current COI aboard vessel.
Deck/Cargo › Mooring/Anchoring › Winch
Issued 9 January 2006
Resolved
Repair anchor winch motor.
Construction/Loadline › Hull › Longitudinal Frame
Issued 9 January 2006
Resolved
Make complete repair to the centerline deck beam iwo collision compartment.
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 9 January 2006
Resolved
Service fixed F/F system prior to operating w/passengers.
Documentation › Markings/Placards › Capacity Marking
Issued 9 January 2006
Resolved
Stencil location/identification, etc. of lifesaving appliances.
Construction/Loadline › Hull › Side Shell
Issued 15 September 2005
Resolved
Prior to operating with passengers, haul out vessel and make available for further inspection of the hull.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 13 April 2005
Resolved
Retroreflective material on various PFDs showing wear. Vessel crew renewed with reflective tape prior to restowage of PFDs.
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 13 April 2005
Resolved
Noted waterlight on one of the 12 person life floats did not work. Vsl crew replace battery and corrected problem.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 13 April 2005
Resolved
Lanyard for waterlight was spliced into the throw line. Vessel crew removed and properly installed waterlight lanyard for ring buoy waterlight.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 13 April 2005
Resolved
Renew vessel anchor light due to excessive U/V crazing of lense. Vessel crew purchase new light and installed.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 13 April 2005
Resolved
Prove proper operation of stern light. Vsl crew replace bulb and corrected deficiency.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 13 April 2005
Resolved
Properly install starboard running light. Running light was not displaying the proper arc rqmts per COLREGS. Vsl crew corrected.
Communications › Visual Communication › Warning Sign (gangway)
Issued 13 April 2005
Resolved
Stencil "Emergency Exit, Keep Clear" on exterior of all emergency exits. Vsl crew had stencil made and painted on exterior of exits.
Communications › Audible Communications › SPD (Other)
Issued 13 April 2005
Resolved
Smoke detectors in port and stbd bunkrooms did not operate when tested. Vsl crew replaced batteries and proved proper operation.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 13 April 2005
Resolved
Replace broken deck plywood for fwd section of port bunkroom. Vsl crew replaced broken section of plywood on deck.
Fire Fighting › Ventilation Systems › Ducts
Issued 13 April 2005
Resolved
Reroute wires or prove proper closure for starboard engine room ventilation closure.
Navigation › Piloting/Steering
Issued 19 May 2004
Resolved
Provide current Navigational Publications (Lightlist and NAV Rules).
Navigation › Collision/Grounding Avoidance
Issued 19 May 2004
Resolved
Renew Port running light. Vessel is restricted to daylight operations until corrected. LEGACY COMPONENT DESC: Navigation Lights
Communications › Alarms/Indicators
Issued 19 May 2004
Resolved
Prove proper operation of bilge alarms. LEGACY COMPONENT DESC: Bilge Alarm
Accommodation/Occupational Safety › Medical/First Aid
Issued 19 May 2004
Resolved
Renew out-dated medication in first aid kit. LEGACY COMPONENT DESC: Medicine Chest
Lifesaving › Buoyant Apparatus
Issued 19 May 2004
Resolved
Renew weak link for the 12 person life float.
Communications › Radio Communications
Issued 19 May 2004
Resolved
Prove proper operation of 406 EPIRB float free device. LEGACY COMPONENT DESC: EPIRB
Lifesaving › Lifejacket/PFD (Type I)
Issued 19 May 2004
Resolved
Properly mark life preserver stowage.
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 7 May 2003
Resolved
Renew engine room fixed fire extinguishing system operating instructions. Instructions found faded and barely ledgeable with lamination pealing away.
Engineering › Bilge Water Management System
Issued 7 May 2003
Resolved
Double clamp pedro connections as necessary throughout bilge piping system. Noted several pedro connections that were only single clamped. LEGACY COMPONENT DESC: Piping
Engineering › Sea-water System (primary cooling)
Issued 7 May 2003
Resolved
Double clamp pedro connection at port main engine cooling water intake. Pedro connection on inboard side of skin valve found double clamped on one side but single clamped on the other side. LEGACY COMPONENT DESC: Piping
Electrical › Electric Generation Source (service)
Issued 7 May 2003
Resolved
Repair or renew negative ground battery cable to port main engine starter. Found small section of insulation on cable worn through to metallic wire. LEGACY COMPONENT DESC: Grounding Conductor
Accommodation/Occupational Safety › Sleeping Accommodations
Issued 7 May 2003
Resolved
Reconfigure ladder arrangement for emergency exit from forward berthing space.
Accommodation/Occupational Safety › Sleeping Accommodations
Issued 7 May 2003
Resolved
Label above and below emergency exit from forward berthing space in accordance with 46 CFR 185.606.
Pollution Prevention/Response › Prevention Equipment
Issued 7 May 2003
Resolved
Provide suitable means for locking overboard discharge valves for port and starboard MSD holding tanks. LEGACY COMPONENT DESC: Sewage System Piping
Engineering › Steering Gear System
Issued 7 May 2003
Resolved
Provide positive means for securing rudder post bolt. LEGACY COMPONENT DESC: Pin
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 7 May 2003
Resolved
Install belly bands for portabnle fire extinguishers.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 7 May 2003
Resolved
Found 5 PFD shoulder lights that were not functional. Vessel operator corrected prior to the completion of the inspection.
Lifesaving › Buoyant Apparatus
Issued 7 May 2003
Resolved
Found waterlight on one of the vessel's 12 person life floats not working. Vessel O/O renewed waterlight prior to the completion of the inspection.
Pollution Prevention/Response › Prevention Equipment
Issued 17 July 2002
Resolved
Renew flex hose and hose clamps for hose in port sewage overboard line. LEGACY COMPONENT DESC: Marine Sanitation Device, Type III
Lifesaving › Visual Distress Signals (General) › Condition
Issued 17 July 2002
Resolved
Repair and prove proper operation of water light for life float.
Accommodation/Occupational Safety › Occupational Safety
Issued 17 July 2002
Resolved
Install retaining chain/cable for water tight hatch cover for lazarette.
Communications › Alarms/Indicators › Bilge Alarm
Issued 17 July 2002
Resolved
Repair and prove proper operation of visual high water alarms for bow bunk room and steering compartment bilges. Audible alarm worked but visual indicator was inoperative when tested.
Documentation › Certificates/Documents
Issued 17 July 2002
Resolved
Provide proof of current Certificate of Documentation. O/O has current COD but did not have document on board. LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Communications › Visual Communication
Issued 17 July 2002
Resolved
Stencil PFD storage locations and emergency fuel shut-off valve reach rod locations. O/O just completed repainting vessel and markings had not been repainted.
Construction/Loadline
Issued 13 June 2001
Resolved
CAP OFF UNUSED THROUGH-HULL VALVE IN ENGINE ROOM.
Electrical
Issued 13 June 2001
Resolved
PROPERLY SPLICE WIRING IN WAY OF BATTERY BOX IN CREW COMPARTMENT AND ON FIRE PUMP AS PER 46 CFR 183.340.
Documentation
Issued 13 June 2001
Resolved
PROVIDE PROOF OF PROPER WASTE MANAGEMENT PLAN AS PER 33 CFR 151.57.
Lifesaving
Issued 13 June 2001
Resolved
PROPERLY ATTACH LIFEFLOAT PAINTERS TO FLOAT-FREE LINKS AS PER 46 CFR 180.137(D)(2). VESSEL NOT TO CARRY PASSENGERS FOR HIRE UNTIL CORRECTED.
Lifesaving
Issued 13 June 2001
Resolved
MARK RING BUOY WITH NAME OF VESSEL AS PER 46 CFR 185.604(B).
Construction/Loadline
Issued 23 October 2000
Resolved
Install new love-joy coupling in bilge pump drive.
Construction/Loadline
Issued 23 October 2000
Resolved
Repair as new main deck above the starboard engine where removed for enginerenewal. (Currently the deck is not weather or water tight and the deck beams are providing no structural support)
Lifesaving
Issued 23 October 2000
Resolved
Remove gasoline from stern of vessel, COI does not allow gasoline on boat.
Construction/Loadline
Issued 23 October 2000
Resolved
Renew water tight hatch on bow. (Current hatch has no fasteners, is not easily accessible, and is not watertight)
Engineering
Issued 23 October 2000
Resolved
Bolt down starboard engine using good marine practice. This requirement included alignment of starboard engine. (currently the starboard engine foundation bolts are missing the securing nuts)
Fire Fighting
Issued 23 October 2000
Resolved
Repair as new engine room fixed fire extinguishing system. (Currently machinery does not shut down when tested) Vessel shall not sail with passengers until this requirement has been corrected and accepted by the attending Marine Inspector.
Construction/Loadline
Issued 23 October 2000
Resolved
Make engine and main deck available for inspection. Vessel is restriced from sailing with passengers until this requirement is met.
Fire Fighting
Issued 25 August 2000
Resolved
INSTALL ADDITIONAL B-II FIRE EXTINGUISHER TO SERVICE GALLEY AS REQUIRED BY [name withheld] 06 JUL 2000.
Fire Fighting
Issued 25 August 2000
Resolved
SUBMIT PLANS TO INSTALL FIRE DETECTION SYSTEM FOR GALLEY GREASE EXTRACTION HOOD IAW MOC POLICY LETTER 4-98
Engineering
Issued 29 June 2000
Resolved
REPAIR AS NEW EXHAUST SYSTEM LEAK IN WAY OF COOLING INJECTION LINE FOR BOTHP/S ENGINES.
Construction/Loadline
Issued 21 April 2000
Resolved
RENEW LAZARETTE SCUTTLE OR MAKE WATERTIGHT.
Lifesaving
Issued 21 April 2000
Resolved
RESTOW LIFEFLOATS AND LIFEFLOAT LIGHTS CORRECTLY.
Lifesaving
Issued 21 April 2000
Resolved
UPDATE FIRST AID KIT
Fire Fighting
Issued 21 April 2000
Resolved
REPAIR AS NEW SMOKE DETECTORS IN WAY OF ACCOMMODATION SPACE.
Lifesaving
Issued 21 April 2000
Resolved
CLEAN GALLEY VENTILATOR HOOD DUCTING.
Construction/Loadline
Issued 21 April 2000
Resolved
CLEAN BILGES AND MAKE OIL FREE.
Electrical
Issued 21 April 2000
Resolved
REPAIR AS NEW EMERGENCY LIGHTING TO STBD ACCOMMODATION SPACE.
Construction/Loadline
Issued 21 April 2000
Resolved
RE-PLUMP BILGE OVERBOARD. BILGE PIPING CANNOT BE INJECTED INTO EXHAUST SYSTEM.
Lifesaving
Issued 21 April 2000
Resolved
REPAIR AS NEW OR REPLACE 29 ADULT PFDS
Construction/Loadline
Issued 21 April 2000
Resolved
LABEL BILGE VALVES.
Engineering
Issued 21 April 2000
Resolved
REPAIR AS NEW EXHAUST SYSTEM LEAK IN WAY OF COOLING INJECTION LINE BOTH P/SENGINES
Accommodation/Occupational Safety
Issued 21 April 2000
Resolved
CLEAN REFRIGERATOR AS IT IS CURRENTLY UNSANITARY.
Engineering
Issued 21 April 2000
Resolved
RENEW FUEL HOSE ON ALL FUEL OIL TANK FILLS. USE A-I, A-II, B-I, OR B-II RATED FUEL HOSE.
Engineering
Issued 21 April 2000
Resolved
RENEW F/O LINE TO VACUUM GAGE WITH "APPROVED" HOSE MEETING OR EXCEEDING SAEJ 1942.
Engineering
Issued 21 April 2000
Resolved
RENEW F/O LINES ON GENERATOR IN WAY OF FILTER TO CYL HEAD, & RACOR FILTER TO PUMP. USE "APPROVED" HOSE MEETING OR EXCEEDING SAE J1942.
Engineering
Issued 21 April 2000
Resolved
RENEW LUBE OIL LINE TO GENERATOR GOVERNOR. USE SAE J 1942 STYLE HOSE.
Construction/Loadline
Issued 21 April 2000
Resolved
MAKEHOLES IN AFT ENGINE ROOM BULKHEAD WATERTIGHT.
Engineering
Issued 21 April 2000
Resolved
TIGHTEN ALL ENGIN FOUNDATION BOLTS
Engineering
Issued 21 April 2000
Resolved
RENEW R/W COOLING LINES ON GENERATOR EXPANSION TANK.
Engineering
Issued 21 April 2000
Resolved
REPAIR AS NEW GENERATOR V BELT GUARD.
Documentation
Issued 16 June 1999
Resolved
Post waste management plan per 33 CFR 151.57
Documentation
Issued 16 June 1999
Resolved
Change certificate of documentation to reflect vessel's actual length as required by 46 CFR 67.319
Lifesaving
Issued 16 June 1999
Resolved
Clean galley range vent hood and make grease free.
Documentation
Issued 16 June 1999
Resolved
Renew Certificate of Documentation.
Lifesaving
Issued 16 June 1999
Resolved
REPAIR OR RENEW 56 ADULT & 1 CHILD PFD. VESSEL IS RESTRICTED TO 28 ADULT AND 7 CHILD PASSENGERS UNTIL COMPLETED
Fire Fighting
Issued 16 June 1999
Resolved
POST OPERATING INSTRUCTIONS FOR FIXED FIRE GIGHTING SYSTEM SERVICING ENGINEROOM
Lifesaving
Issued 16 June 1999
Resolved
Mark upper decks for maximum number of passengers per 46 CFR 185.620(g)
Documentation
Issued 16 June 1999
Resolved
Log training per 46 CFR 185.420
Documentation
Issued 16 June 1999
Resolved
Show proof of payment of user fees
Lifesaving
Issued 16 June 1999
Resolved
INSTALL GREASE EXTRACTION HOOD AS REQUIRED BY 46 CFR 181.425
Documentation
Issued 8 December 1998
Resolved
SUBMIT PLAN FOR BILGE ALARMS
Engineering
Issued 8 December 1998
Resolved
REPAIR AS NEW EMERGENCY F/O STOP VALVES
Documentation
Issued 8 December 1998
Resolved
SUBMIT PROPOSAL TO REPAIR AS NEW STBD AFT QUARTER FRAMING AT TURN OF BILGE IN WAY OF DE-LAMINATING FRAMES
Construction/Loadline
Issued 8 December 1998
Resolved
OPEN FOR INSPECTION AREA AS INDICATED IN ITEM #4
Engineering
Issued 8 December 1998
Resolved
TIGHTEN MOTOR MOUNTS
Documentation
Issued 9 November 1998
Resolved
Prove actual vessel length end over end over the deck excluding sheer or remeasure vessel in presence of attending marine inspector.
Accommodation/Occupational Safety
Issued 9 November 1998
Resolved
Make permanent repairs to cracked welds on embarkation/disembarkation ladder.
Construction/Loadline
Issued 9 November 1998
Resolved
Make permanent repairs to starbord side transom above the water line damaged by impact.
Accommodation/Occupational Safety
Issued 9 November 1998
Resolved
Make permanent reapairs to fractured weld at base of hand supports.
Engineering
Issued 20 August 1998
Resolved
REPAIR AS NEW MORSE CONTROL CABLE TO STBD MAIN ENGINES
Lifesaving
Issued 30 July 1998
Resolved
MAKE ENGIEROOM BILGES FREE FROM OIL.
Engineering
Issued 30 July 1998
Resolved
RENEW AS ORIGINAL BME EXHAUST HOSE IN WAY OF ENGINEROOM USING APPROVED HOSE
Engineering
Issued 30 July 1998
Resolved
REPAIR AS NEW EXHAUST LAGGING TO BOTH MAIN ENGINES AND SUBMIT REPAIR PROPOSAL TO REPLACE ROPE STRAPS ON PORT ENGINE EXHAUST SYSTEM.
Electrical
Issued 30 July 1998
Resolved
INSTALL WIRING CLAMPS EVERY 12" TO 18" ON WIRING IN BRIDGE.
Lifesaving
Issued 30 July 1998
Resolved
STOW WORK VESTS SEPERATE FROM PASSENGER VESTS
Accommodation/Occupational Safety
Issued 30 July 1998
Resolved
REPAIR AS NEW EMERGENCY LIGHTING PER 46 CFR 184.30
Engineering
Issued 30 July 1998
Resolved
REPAIR AS NEW ENGINE TACHOMETER TO STBD ENGINE
Construction/Loadline
Issued 30 July 1998
Resolved
MAKE ALL DECK HATCHES WATERTIGHT
Engineering
Issued 30 July 1998
Resolved
REPAIR EMERGENCY F/O STOP VALVE TO STBD AFT F/O TANK
Engineering
Issued 30 July 1998
Resolved
TIGHTEN ENGINE FOUNDATION BOLTS
Documentation
Issued 30 July 1998
Resolved
KEEP LOGS AS REQ FOR EPIRB, LIFESAVING, DRILL/TRAINING PER 46 CFR 185
Engineering
Issued 30 July 1998
Resolved
REPAIR AS NEW V-BELT GUARD ON GENSET
Documentation
Issued 30 July 1998
Resolved
POST STATION BILL AS REQUIRED BY 46 CFR 185
Fire Fighting
Issued 30 July 1998
Resolved
PROVIDE PROOF OF SERVICING PORTABLE FIRE EXTINGUISHERS
Lifesaving
Issued 30 July 1998
Resolved
CLEAR DECK OF LOOSE DEBRIS
Lifesaving
Issued 30 July 1998
Resolved
PROVIDE APPROVED FIRST AID KIT
Navigation
Issued 30 July 1998
Resolved
REPAIR AS NEW STEERING SYSTEM IN WAY OF LAZARETTE
Lifesaving
Issued 30 July 1998
Resolved
MOUNT 406 EPIRB
Accommodation/Occupational Safety
Issued 30 July 1998
Resolved
INSTALL LOCKING DEVICE ON MSD OVERBOARD
Lifesaving
Issued 30 July 1998
Resolved
INSTALL SPACERS BETWEEN LIFE FLOATS
Lifesaving
Issued 30 July 1998
Resolved
POST PLACARD "FOR CREW ONLY NO PASSENGERS" FWD COMPARTMENT
Lifesaving
Issued 30 July 1998
Resolved
INSTALL RETROREFLECTIVE TAPE ON ALL LIFE RING BUOYS, INSTALL LIGHT ON ONE 1LIFERING BOUY W/ CORROSION REISTANT DETACHABLE LINK.
Engineering
Issued 30 July 1998
Resolved
REPAIR AS NEW EXPANSION TANK TO COOLING SYSTEM ON GENSET.
Fire Fighting
Issued 30 July 1998
Resolved
PROVIDE NOZZLE FOR FIRE HOSE.
Navigation
Issued 30 July 1998
Resolved
POST EMERGENCY BROADCAST PLACARD
Navigation
Issued 30 July 1998
Resolved
PROVIDE CURRENT AND UPDATED COPY OF T REGULATIONS, LIGHTLISTS, TIDE TABLES,AND CHARTS FOR OPERATING ZONE.
Lifesaving
Issued 30 July 1998
Resolved
INSTALL COVER ON LIGHTS IN ENGINEROOM.
Engineering
Issued 30 July 1998
Resolved
REPAIR AS NEW ENGINE STOPS ON BMDE
Unknown
Issued 3 December 1997
Resolved
Replace both head discharge valves.
Unknown
Issued 3 December 1997
Resolved
Conduct an underway sea trial after hull exam, with a Coast Guard marine inspector presence.
Navigation
Issued 13 May 1997
Resolved
Provide a compass deviation card.
Construction/Loadline
Issued 13 May 1997
Resolved
Make the bow hatch water tight.
Electrical
Issued 13 May 1997
Resolved
Install fuse in line from the battery to the 12 volt water pump.
Engineering
Issued 13 May 1997
Resolved
Install guard for tail shafts.
Fire Fighting
Issued 13 May 1997
Resolved
Service fire extinguishers.
Construction/Loadline
Issued 29 November 1995
Resolved
Replace wasted bilge piping to after steering compartment. Steering compartment bilge suction must be tested in the presence of a marine inspector. This item to be completed before vessel operates with passengers.
Construction/Loadline
Issued 29 November 1995
Resolved
Replace valve handle on forepeak bilge suction valve and make operable remote valve closure. This item to be completed before vessel operates withpassengers.
Lifesaving
Issued 29 November 1995
Resolved
Vessel primary lifesaving for oceans route two (2) shy of the required 50. Reduced total passengers allowed by two (2) when vessel operating on the oceans route.
Lifesaving
Issued 12 May 1994
Resolved
REPLACE TWO RING BUOYS_x001C_ _x001C_ _x001C_ _x001C_
Electrical
Issued 12 May 1994
Resolved
CLEAN UP THE WIRING CONNECTIONS TO BATTERIES WITH PROPER CONECTORS.
Electrical
Issued 12 May 1994
Resolved
BLOCK THE BATTERIES IN THE BATTERY BOX.
Lifesaving
Issued 12 May 1994
Resolved
GET THE VESSEL UNDERWAY WITH A COAST GUARD INSPECTOR AND CONDUCT EMERGENCY DRILLS.
Documentation
Issued 12 May 1994
Resolved
SUPPLY THE VESSEL WITH REQUIRED PUBLICATIONS AS PER 46 CFR 185.20-35.
Lifesaving
Issued 12 May 1994
Resolved
PROVIDE 5 ADDITIONAL COAST GUARD APPROVED TYPE 1 ADULT LIFEJACKETS PRIOR TOCARRING MORE THAT 79 ADULTS.
Accommodation/Occupational Safety
Issued 12 May 1994
Resolved
LOCK THE MSD OVERBOARD VALVES.
Navigation
Issued 10 June 1992
Resolved
Repair and prove proper operation of navigation lights. Vessel is not to operate until this requirement is satisfied.
Fire Fighting
Issued 10 June 1992
Resolved
Service vessel's fire extinguishers.
Accommodation/Occupational Safety
Issued 10 June 1992
Resolved
Clean bilges under forward berthing.
Documentation
Issued 10 June 1992
Resolved
Provde vessel with waste disposal plan, post same on board vessel. Provideproof of enrollment in a substance abuse testing program.
Lifesaving
Issued 10 June 1992
Resolved
Provide vessel with six (06) additional adult P.F.D.'s. Vessel may only carry a total forty-six (46) persons on board until this requirement is satisfied.
Casualty record · 2
28 July 2006Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2759788
27 November 2009Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3657562
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.