Records from 1990 to 2026. Most recent: inspection, 29 April 2026.
Documentation record
Registered dimensions (L × B × D)36.0 ft × 12.0 ft × 2.5 ft
Registered tonnagegross 9 / net 9
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNETWORK MARINE INC · BELLE RIVER, LA, UNITED STATES · built 1990
Hull materialAluminum
PropulsionGasoline Outboard
Hull shapeBox
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 31 July 2026 · expires 31 August 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it9 - Simplified, Gross Ton
9 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 43
29 April 2026
Annual Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8345392
21 March 2025
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8097671
30 April 2024
Internal Structural Exam · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7894137
18 April 2023
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7666514
24 February 2022
COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7393598
1 December 2020
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7092344
17 January 2020
Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6891761
2 December 2019
Annual Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6850156
1 November 2018
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6568421
11 December 2017
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6314761
19 October 2016
COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6021900
2 November 2015
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5753285
21 October 2014
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5006351
18 October 2010
Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3859452
27 October 2008
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3342146
9 May 2008
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3202692
31 October 2007
Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3090726
22 October 2007
Administrative Inspection · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3077845
24 October 2006
COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2804567
1 February 2006
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2576571
3 February 2005
Hull Examination
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2285990
14 October 2004
Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2221063
2 December 2003
Deficiency Check
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1957815
12 November 2003
Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1946524
7 October 2002
Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1685717
15 October 2001
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1431117
23 July 2001
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1370299
26 July 2000
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1449353
29 February 2000
Hull Examination · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1452634
2 February 2000
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 814782
28 July 1999
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1361027
22 December 1998
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 807569
20 August 1998
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1400814
30 July 1997
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1380946
30 July 1996
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1460019
30 August 1995
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 886143
7 August 1995
Deficiency Check · Re-Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1357280
25 July 1994
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1458180
10 September 1993
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1436796
11 September 1992
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1254619
11 September 1991
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1247203
19 September 1990
Initial Certification
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1219612
7 September 1990
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 911776
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 April 2024
Resolved
The frame or support of each semi-portable fire extinguisher permitted by paragraph (a) of this section must be welded or otherwise permanently attached to a bulkhead or deck. Portable fire extinguisher bracket was found cracked and non serviceable.
46 CFR 181.500(d) 16C
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2024
Resolved 3 May 2024
Resolution: Operator replaced broken extinguisher bracket with a new, approved replacement and provided photos of installation to the satisfaction of the attending MI.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 December 2020
Resolved
Each life jacket must be approved in accordance with either 160.002, 160.005, or 160.055 in subchapter Q of this chapter. Lifejacket was deterioriating and had a rip in it. Replace to the satisfaction of the Marine Inspector.
Action required: 10 - Deficiency Rectified
Resolved 1 December 2020
Resolution: Corrected on the Spot.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 December 2020
Resolved
Each floating waterlight, on a vessel carrying only one ring buoy, must be attached to the lanyard with a corrosion resistant clip. The waterlight line was attached to the bouy with a knot. Replace to the satisfaction of the Marine Inspector.
Action required: 10 - Deficiency Rectified
Resolved 1 December 2020
Resolution: Corrected on the Spot.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 December 2019
Resolved
Each life jacket must be in accordance with applicable regulations within 46 CFR Subchapter Q. Identified 11 lifejackets that were dry-rotted and an additional 02 requiring new SOLAS Retro Reflective tape. Max passenger count reduced from 62 to 49 until lifejackets replaced or repaired to satisfaction of marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 2 December 2019
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 2 December 2019
Resolved
All small passenger vessels must have navigation lights that are in compliance with the applicable sections of Inland Navigation Rules. Vessel's running lights were found to not be operable. Prior to night time operations, correct to satisfaction of marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 6 December 2019
Resolution: 06DEC19: Recieved pictures of all navigations lights onboard the vessel operating properly. Cleared def, allowed vessel to operate at night if desired.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 December 2019
Resolved
Life buoys must meet the standards of 46 CFR 160.050. Life buoy grab line found to be deteriorated and fraying. Within two weeks, complete repairs to satisfaction of USCG marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 December 2019
Resolution: Recieved picture of life buoy grab line w/ new black line attached.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 11 December 2017
Resolved
Vessel must conduct mandated crew training of lifesaving and firefighting drills every 3 months, as per 46CFR185.420.
Condition: Invalid
Action required: 705 - Other - as specified
Due 11 December 2017
Resolved 11 December 2017
Resolution: Discussed with vessel master the frequency of crew training drills, and expectations of training and logging.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 18 October 2010
Resolved
Vessel missing one floating waterlight. Connect a floating waterlight with a clip on the vessels lifebuoy. Vessel restricted to daylight operations until resolved.
Action required: 705 - Other - as specified
Due 18 November 2010
Resolved 29 November 2010
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 18 October 2010
Resolved
Mast light has burned out bulb. Replace with new bulb. Vessel restircted to day light operations until resolved.
Action required: 705 - Other - as specified
Due 18 November 2010
Resolved 29 November 2010
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 22 October 2007
Resolved
6 Lifejackets were taken out of service due to dry rot. Vessels passenger capacity is reduced to 57 until Damaged Lifejackets have been replaced.
Condition: Unknown
Due 1 November 2007
Resolved 31 October 2007
Resolution: Attending Marine inspector received receipt of new replacement life jackets.
Fire Fighting › Fire Bucket › Capacity
Issued 24 October 2006
Resolved
Replace three 5 gallon fire buckets with three 2.5 gallon fire buckets.
Due 24 November 2006
Resolved 31 October 2006
Resolution: Received receipt for 2.5 gallon fire buckets for SWAMP QUEEN III.
Electrical › Electrical Distribution System (service)
Issued 12 November 2003
Resolved
Provide wire supports for all wiring on vessel in 24" lengths. LEGACY COMPONENT DESC: Wiring
Action required: 705 - Other - as specified
Due 12 December 2003
Resolved 2 December 2003
Resolution: Wire supports were provided.
Accommodation/Occupational Safety
Issued 2 February 2000
Resolved
PROVIDE A USCG APPROVED MARINE SANITATION DEVICE FOR THE INSTALLED TOILET IAW 33CFR159.
Condition: Unknown
Due 2 February 2000
Resolved 2 February 2000
Construction/Loadline
Issued 20 August 1998
Resolved
CROP AND RENEW WASTED BULKHEAD BETWEEN SEWAGE TANK AND AFT VOID. REPAIRS TO BE WITNESSED BY COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 20 August 1998
Resolved 20 August 1998
Documentation
Issued 25 July 1994
Resolved
LOCATE AND PLACE COPY OF VESSEL'S FCC STATION LICENSE ABOARD VESSEL.
Condition: Unknown
Due 25 July 1994
Resolved 25 July 1994
Documentation
Issued 25 July 1994
Resolved
LOCATE AND PLACE ORIGINAL CERTIFICATE OF DOCUMENTATION ABOARD VESSEL.
Condition: Unknown
Due 25 July 1994
Resolved 25 July 1994
Engineering
Issued 10 September 1993
Resolved
MAKE ADEQUATE CHANGE TO FUEL TANK ARRANGEMENT TO MAKE INDEPENDENT OF VESSEL'S HULL (46CFR182.15-25)
Condition: Unknown
Due 10 September 1993
Resolved 10 September 1993