MAURY USCG vessel records
← All vessels

RIVER RUNNER

RIVER RUNNER is a 1990 passenger vessel (inspected). The Coast Guard has recorded 12 inspections since 2016, most recently in June 2025, along with 14 deficiencies — 1 with no resolution recorded —.

Records from 2016 to 2025. Most recent: inspection, 18 June 2025.

Built
1990
Last inspected
18 June 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 18 June 2025
…past their stated due date1
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDN7500
354382
Flag
UNITED STATES
Maury page id
psix-354382

Documentation record

Registered dimensions (L × B × D)38.0 ft × 10.0 ft × 3.0 ft
Registered tonnagegross 7 / net 6
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMAURELL PRODUCTS INC · OWOSSO, MI, UNITED STATES · built 1990
Hull materialAluminum
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationMonohull
Hailing portCRYSTAL RIVER, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 4 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it7 - Simplified, Gross Ton
6 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 12

18 June 2025 Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8150076
1 May 2024 Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7896930
8 June 2023 COI Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7703786
5 April 2023 Drydock Exam · Administrative Inspection · Internal Structural Exam · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7663233
2 February 2023 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7631218
25 May 2021 Annual Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7193829
20 April 2020 Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6941292
15 April 2020 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6935913
8 May 2019 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6678268
5 March 2018 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6361753
16 May 2017 COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6143233
22 April 2016 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5860402

Deficiency record · 14

01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 18 June 2025 Resolved
Any vessel of at least five net tons which engages in the fisheries on the navigable waters of the United States or in the Exclusive Economic Zone, or Coastwise trade, must have a Certificate of Documentation bearing a valid endorsement appropriate for the activity in which engaged. Vessel did not have a current valid COD on board. 46 CFR 67.7
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 June 2025
Resolved 24 June 2025
Resolution: Received satisfactory photo evidence of correction. Validity of COD verified in MISLE.
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 18 June 2025 Resolved
Employers must maintain records of chemical tests. Vessel did not have current record of drug and alcohol consortium enrollment or proof of chemical testing for crewmembers, or current (2024) MIS report data from consortium. 46 CFR 16.260
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 June 2025
Resolved 24 June 2025
Resolution: Received satisfactory photo evidence of correction.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 18 June 2025 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Vessel's starboard running light was inoperable and the stern light lens was severely hazy due to UV damage. Vessel is restricted to daytime operations only until light/lens is replaced. 46 CFR 183.420
Action required: 705 - Other - as specified
Due 18 June 2025
Resolved 24 June 2025
Resolution: Received satisfactory photo evidence of correction.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 18 June 2025 Resolved
The required fire, man overboard and abandon ship drills and training shall be logged. MI observed insufficient proof that drills were being performed. 46 CFR 185.520(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2025
Resolved 26 June 2025
Resolution: Received satisfactory photo evidence of correction.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 18 June 2025 Resolved
The required fire extinguisher maintenance (monthly checks) shall be logged. MI observed insufficient proof that maintenance was being performed. 46 CFR 176.810(b)(1)(iv)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2025
Resolved 26 June 2025
Resolution: Received satisfactory photo evidence of correction.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 18 June 2025 Resolved
As appropriate for intended voyage, a vessel must carry adequate and up-to-date: U.S. Coast Pilot or similar publication (Inland Navigation Rules), Coast Guard Light List and Tide tables. Extracts from the publications listed above for the areas to be transited may be provided instead of the complete publication. Vessel did not have the above listed navigation publications onboard. 46 CFR 184.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2025
Resolved 26 June 2025
Resolution: Received satisfactory photo evidence of correction.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 1 May 2024 Resolved
Gauges to indicate cooling water discharge temperature and lubricating oil pressure shall be provided for all propulsion engines and located so as to be in the view of the operator. Vessel's oil alarm indicator for the port side outboard engine was flashing during routine operation of the vessel. Determine cause and take corrective action for oil alarm. 46 CFR 182.15-5(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 May 2024
Resolved 6 May 2024
Resolution: Received invoice evidence for servicing of outboard engines.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 June 2023 Resolved
The minimum number of portable fire extinguishers on a vessel must not be fewer than the minimum required by Table 181.500(b). Vessel is missing a size 10 B:C portable fire extinguisher for the operating station. 46 CFR 181.500(a)(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2023
Resolved 15 August 2023
Resolution: Verified the addition of a portable fire extinguisher for the operating station.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 June 2023 Resolved
Overcurrent protection: Fuses must be of the cartridge type only and be listed by the Underwriters Laboratory (UL) or another independent laboratory recognized by the Commandant. Vessel has blade style fuses installed between the 12 volt batteries and the motor control units. 46 CFR 183.380(l)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2023
Resolved 15 August 2023
Resolution: Verified the installation of proper cartridge fuses for motor control units.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 8 June 2023 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date navigation publications necessary for voyage. Vessel did not have navigation publications onboard. Obtain proper copies of the Inland Navigation Rules, light lists, and tide prediction tables for vessel's intended area of operation. 46 CFR 184.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2023
Resolved 23 August 2023
Resolution: Received photo evidence of required navigation chart and publications onboard.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 24 April 2023 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. Vessel's first aid kit was missing several of the required contents or contents were expired. Vessel must acquire a complete first-aid kit prior to operation with passengers.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 April 2023
Resolved 31 May 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 May 2021 No resolution recorded
Where flexible nonmetallic hose is permitted for use in piping systems by this section, it must meet SAE J-1942. The fuel tanks' flexible nonmetallic hoses did not meet SAE- J-1942 and were unservicable. Replace complete fuel hose assemblies with SAE J-1942 hoses.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 June 2021 — due date passed with no resolution recorded
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 16 May 2017 Resolved
x11 lifejackets deteriorated around strap attachemnts or reflective tape deteriorated. Corrected on the spot.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 May 2017
Resolution: Replaced x11 lifejackets.
Lifesaving › Lifebuoys › Serviceable
Issued 16 May 2017 Resolved
Hand line on Life ring found deteriorated.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 May 2017
Resolution: RCVD Sufficient evidence that life ring was replaced with new.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.