CHIOS FIGHTER
CHIOS FIGHTER is a 1973 freight ship. The Coast Guard has recorded 29 inspections since 1990, most recently in July 1998, along with 182 deficiencies and 4 operational controls.
Records from 1990 to 1998. Most recent: inspection, 29 July 1998.
- Built
- 1973
- Last inspected
- 29 July 1998
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 182 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
7354917 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
3ESN5
354445
Flag
PANAMA
—
Maury page id
psix-354445
Inspections, by type
…with no type recorded29
Years with a record
6 calendar years (1990–1998)
The 29 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 28 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it5992 - Regulatory (Subpart C or D), Net Ton
16142 - Dead Weight, Ton
9921 - Regulatory (Subpart C or D), Gross Ton
16142 - Dead Weight, Ton
9921 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 29
29 July 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 717497
28 July 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 418853
4 July 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 106418
4 July 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 130868
20 January 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 38040
20 January 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 412382
14 November 1997
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 410056
12 June 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 404742
15 April 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 402724
26 February 1997
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 400877
3 January 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 399257
29 November 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 398034
8 June 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 392092
1 May 1996
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 390713
27 December 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 677718
6 November 1995
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 384410
25 September 1995
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 677713
21 September 1995
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 382871
26 July 1995
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 380920
21 July 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 381005
11 May 1995
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 378315
3 April 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 376905
1 April 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 112901
4 January 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 373952
24 December 1994
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1163850
31 August 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 677714
4 August 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 369133
4 August 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1174443
7 August 1990
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 339336
Deficiency record · 182
Engineering
Issued 28 July 1998
Resolved
Improve the overall condition of the machinery spaces (oil, housekeeping, etc.) prior to departure. _x001C_ _x001C_ SOLAS 60 I/11
Electrical
Issued 28 July 1998
Resolved
Provide a class report addressing the proper installation of the generator on the stern of the vessel prior to departure. _x001C_ _x001C_ SOLAS 60 II/27
Lifesaving
Issued 28 July 1998
Resolved
Provide lifejackets for the watch in the machinery space prior to departure. _x001C_ _x001C_ SOLAS 60 III/22
Electrical
Issued 28 July 1998
Resolved
Provide proper ventilation for the emergency batteries prior to departure. _x001C_ _x001C_ SOLAS 60 II/27
Fire Fighting
Issued 28 July 1998
Resolved
Replace the numerous missing portable fire extinguishers through the vesselprior to departure. _x001C_ _x001C_ SOLAS 60 II/57
Electrical
Issued 28 July 1998
Resolved
Repair the exhaust leak on the number one generator engine exhaust line prior to returning to a U. S. port. _x001C_ _x001C_ SOLAS 60 I/11
Engineering
Issued 28 July 1998
Resolved
Demonstrate proper operation of the vent fan in the engine control space prior to departure. _x001C_ _x001C_ SOLAS 60 I/11
Electrical
Issued 28 July 1998
Resolved
Remove the temporary generator arrangement from the WX deck (about the stack) and repair the inoperative port generator engine prior to return to a U. S. port. _x001C_ SOLAS 60 II/26
Lifesaving
Issued 28 July 1998
Resolved
Permanently repair the air motor for the lifeboat davits and prove proper operation prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 60 III/4
Fire Fighting
Issued 28 July 1998
Resolved
Permanently repair the fwd main fire pump (rewind, etc.) and prove proper operation prior to return to a U. S. port._x001C_ _x001C_ SOLAS 60 II/56
Engineering
Issued 28 July 1998
Resolved
Make permanent repairs to the exhaust leak on the stbd generator engine prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 60 I/11
Fire Fighting
Issued 28 July 1998
Resolved
Assure hold back hooks are removed from all machinery space fire doors prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 60 II/54
Engineering
Issued 28 July 1998
Resolved
Have class evaluate the need for the fuel solenoid valve on the auxiliary boiler and repair system as necessary prior to return to a U. S. port. _x001C_ SOLAS 60 I/11
Engineering
Issued 28 July 1998
Resolved
Repair the fuel leaks about the pump that is adjacent to the auxiliary boiler and clean all fuel from the bilges prior to return to a U. S. port. _x001C_ SOLAS 60 I/11
Fire Fighting
Issued 28 July 1998
Resolved
Repair the hold in the bulkhead adjacent to the port fire door (adjacent tothe auxiliary boiler) prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 60 II/54
Fire Fighting
Issued 28 July 1998
Resolved
Assure all fire nozzles in the machinery space are spray type prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 60 II/56
Fire Fighting
Issued 28 July 1998
Resolved
Perform a close / internal evaluation of the strainers on both main fire pumps as they are heavily patched & wasted. Make necessary repairs prior to return to a U. S. port. _x001C_ SOLAS 60 II/56
Electrical
Issued 28 July 1998
Resolved
Provide a cover for the flywheel, replace the missing air filter assembly, and clean the oil from about the stbd generator engine prior to return to aU. S. port. _x001C_ SOLAS 60 I/11
Engineering
Issued 28 July 1998
Resolved
Replace the missing belt drive cover on the OWS pump prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 60 I/11
Accommodation/Occupational Safety
Issued 28 July 1998
Resolved
Patch the hole in the deck that is above the aft M/E turbo charger (leadingto the stairs) prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 60 I/11
Engineering
Issued 28 July 1998
Resolved
Completely evaluate the cast steel head on the stbd air compressor and replace / repair as required by class. Also replace the missing flywheel cover. Complete prior to return to a U. S. port. _x001C_ SOLAS 60 I/27
Navigation
Issued 28 July 1998
Resolved
Make a complete evaluation of the #1 steering pump assembly and make any adjustments / repairs as required. Under local control, the #1 pump is very difficult to operate as compared to the #2 local system (>60 sec to move 30 degrees). Complete prior to return to a U. S. port. SOLAS 60 II/29
Fire Fighting
Issued 28 July 1998
Resolved
Repair, renew or clean the sight glasses on the emergency fire pump fuel tank and foam tanks (levels are unreadable) prior to return to a U. S. port. _x001C_ SOLAS 60 II/56
Construction/Loadline
Issued 28 July 1998
Resolved
Make a complete evaluation of the hole in the main hatch covers and make necessary repairs prior to return to a U. S. port._x001C_ _x001C_ ICLL 66 II/15
Lifesaving
Issued 28 July 1998
Resolved
Have class evaluate the need for the quick release system on the stbd lifeboat and repair or remove. The system is disabled about the stern. Complete prior to return to a U. S. port. _x001C_ SOLAS 60 III/5
Deck/Cargo
Issued 28 July 1998
Resolved
Make permanent repairs to the leaking hydraulic systems about the main deckand contain all oil to prevent entry into the water. (crane winches, fore/aft windlasses) Complete prior to return to a U. S. port._x001C_ 33 CFR 151.10(b)
Accommodation/Occupational Safety
Issued 28 July 1998
Resolved
Replace all burned out lighting in the machinery space prior to return to aU. S. port. _x001C_ _x001C_ SOLAS 60 I/11
Navigation
Issued 28 July 1998
Resolved
Repair the phone connection between the bridge & steering gear space prior to departure from port. _x001C_ _x001C_ SOLAS 60 II/33
Fire Fighting
Issued 28 July 1998
Resolved
Demonstrate that the emergency fire pump can provide adequate pressure to fight a fire prior to departure. _x001C_ _x001C_ SOLAS 60 II/56
Engineering
Issued 28 July 1998
Resolved
Clean all oil from about the machinery bilges, drip trays, engines, and decks prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 60 I/11
Accommodation/Occupational Safety
Issued 28 July 1998
Resolved
Repair or replace all stanchions on the port side accommodation ladder prior to departure from port. _x001C_ _x001C_ SOLAS 74 amd V/17(b)(ii)
Lifesaving
Issued 28 July 1998
Resolved
Demonstrate proper operation of both lifeboats (lowering / running of engines) prior to departure from port. _x001C_ _x001C_ SOLAS 74 amd II/19-2
Fire Fighting
Issued 28 July 1998
Resolved
Prove proper operation of the #2 main fire pump prior to departure from port._x001C_ _x001C_ SOLAS 60 II/56
Construction/Loadline
Issued 20 January 1998
Resolved
REMOVE EXCESS OIL OF 2ft FROM BILGE (SOLAS 60 REG 2-34).
Lifesaving
Issued 20 January 1998
Resolved
REPLACE LIFE JACKET IN CONTROL ROOM (SOLAS 60REG 3/22).
Fire Fighting
Issued 20 January 1998
Resolved
#1 MAIN FIRE PUMP IS INOPERATIVE. (SOLAS 60 REG 2/56)
Fire Fighting
Issued 20 January 1998
Resolved
REPAIR/REPLACE FIRE HOSE BOX IN ENGINE ROOM FROZEN SHUT. (SOLAS 74 (AMEND) REG 2/2-21).
Construction/Loadline
Issued 20 January 1998
Resolved
MSDS IS INOPERABLE. PVC PIPES ARE NOT WELDED TOGETHER. MISSING PLACARD AND IS NOT CERTIFIED. (33 C.F.R. 159).
Documentation
Issued 20 January 1998
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Lifesaving
Issued 20 January 1998
Resolved
STARBOARD LIFEBOAT IS UNABLE TO BE LOWERED. (SOLAS 74 (AMEND) REG 3 19/2)
Documentation
Issued 20 January 1998
Resolved
INVALID COFR (33 C.F.R. ---)
Lifesaving
Issued 20 January 1998
Resolved
STARBOARD LIFE BOAT MAKE REPAIRS TO PELICAN HOOK BRACKETS INSIDE BOAT.( SOLAS 74 (AMEND) REG 3 19-2)
Lifesaving
Issued 20 January 1998
Resolved
PROVE PROPER OPERATION OF LIFE BOAT. (SOLAS 74 (AMEND) REG 3 /19-2)
Electrical
Issued 20 January 1998
Resolved
LIGHT PANEL IN ENGINE CONTROL ROOM IS INOPERABLE. (SOLAS 60 REG 2/27)
Accommodation/Occupational Safety
Issued 20 January 1998
Resolved
DECK INSERT ON FOCSALE IS NOT PROPERLY WELDED UNDERNEATH. (ILCC 66 ANNEX 11/1)
Fire Fighting
Issued 26 February 1997
Resolved
RENEW/REPAIR THE SEA WATER STRAINER FOR THE MAIN FIRE PUMP LOCATED ON THE PORT SIDE LOWER LEVEL ENGINE ROOM._x001C_ SOLAS 74 (AMENDED) I/11(a) & II-2/21
Accommodation/Occupational Safety
Issued 26 February 1997
Resolved
RENEW AS ORIGINAL THE DETERIORATED/LEAKING STEAM LINES LOCATED ON THE 2ND LEVEL OF THE ENGINEROOM, PORT SIDE, NEXT TO THE FIRE HOSE STATION #108._x001C_ SOLAS 74 (AMENDED) I/11(a)
Accommodation/Occupational Safety
Issued 26 February 1997
Resolved
RENEW AS ORIGINAL THE DETERIORATED BALLAST PIPES LOCATED ABOVE THE LUBE OILPURIFIERS IN THE ENGINE ROOM, 3RD LEVEL FORWARD OF THE ENGINE COOLERS._x001C_ SOLAS 74 (AMENDED) I/11(a)_x001C_
Lifesaving
Issued 26 February 1997
Resolved
POST EMERGENCY MUSTER LIST IN THE MAIN ENGINE CONTROL ROOM._x001C_ SOLAS 74 (AMENDED) III/8.3
Accommodation/Occupational Safety
Issued 26 February 1997
Resolved
RENEW AS ORIGINAL THE DETERIORATED SEA WATER LINE LOCATED ON THE UPPER LEVEL OF THE ENGINE ROOM FORWARD OF THE MAIN LUBE OIL
Accommodation/Occupational Safety
Issued 26 February 1997
Resolved
RENEW AS ORIGINAL THE DETERIORATED STEAM DISCHARGE LINE LOCATED AT THE STEAM CONDENSER COOLER UPPER LEVEL OF THE ENGINE ROOM. _x001C_ SOLAS 74 (AMENDED) I/11(a)
Fire Fighting
Issued 26 February 1997
Resolved
RENEW/REPAIR THE DETERIORATED/INOPERABLE VENT CLOSURE LOCATED THE PORT SIDEOFFICERS DECK._x001C_ SOLAS 60 II/47(a)
Fire Fighting
Issued 26 February 1997
Resolved
REMOVE THE ELECTRICAL CABLE AND RUBBER TUBING FROM THE MUSHROOM VENT LOCATED ON THE AFT PORT BRIDGE WING SO THAT THE CLOSURE IS FULLY OPERATIONAL._x001C_ SOLAS 60 II/47 (a)
Construction/Loadline
Issued 26 February 1997
Resolved
RENEW/REPAIR ALL MISSING DOGS FOR THR ENGINE ROOM SKY LIGHTS LOCATED ON THE03 DECK._x001C_ ICCL ANNEX I/17
Construction/Loadline
Issued 26 February 1997
Resolved
REPAIR THE MAIN ENGINE STACK CASING WHERE DETERIORATED ON THE FORWARD SIDE OF THE STACK ON THE 03 DECK._x001C_ ICLL ANNEX I/17
Electrical
Issued 26 February 1997
Resolved
PROVE THE PROPPER OPERATION OF ALL DECK LIGHTS THROUGHOUT THE VESSEL._x001C_ SOLAS 74 (AMENDED) I/11(a)
Fire Fighting
Issued 26 February 1997
Resolved
RENEW/REPAIR THE BROKEN FIRE BOX LOCATED ON THE POOP DECK ._x001C_ SOLAS 74 (AMENDED) II-2/21
Fire Fighting
Issued 26 February 1997
Resolved
RENEW THE BROKEN FIRE HYDRANT HANDLE LOCATED ON THE PORT SIDE NEXT TO THE FIRE PLAN._x001C_ SOLAS 74 (AMENDED) II-2/21
Accommodation/Occupational Safety
Issued 26 February 1997
Resolved
REPAIR ALL MISSING/DETERIORATED GUARD RAILS THROUGHOUT THE VESSEL._x001C_ ICLL 66 ANNEX I/25
Construction/Loadline
Issued 26 February 1997
Resolved
REPAIR DETERIORATED KNIFE EDGE LOCATED ON THE WEATHERTIGHT DOOR ON THE AFT PORT MAIN DECK, GOING INTO THE MAIN HOUSE._x001C_ ICLL ANNEX I/18
Construction/Loadline
Issued 26 February 1997
Resolved
RENEW THE DETERIORATED STANCHION FOR THE PILOT LADDER DAVIT._x001C_ SOLAS 74 (AMMENDED) V/17(a)(i)
Electrical
Issued 26 February 1997
Resolved
RENEW/REPAIR THE BROKEN DECK LIGHT MOUNTING BRACKET LOCATED ON THE PORT SIDE, AFT MAIN DECK._x001C_ SOLAS 74 (AMENDED) I/11(a)
Construction/Loadline
Issued 26 February 1997
Resolved
RENEW/REPAIR THE DETERIORATED KNIFE EDGE FOR THE WEATHERTIGHT DOOR LOCATED ON THE STARBOARD SIDE OF THE #1 DECK HOUSE._x001C_ ICLL 66 ANNEX I/18
Fire Fighting
Issued 26 February 1997
Resolved
RENEW THE DETERIORATED VENTILATOR AND CLOSURE FOR THE #4 TOP SIDE TANK._x001C_ ICLL 66 ANNEX I/19
Fire Fighting
Issued 26 February 1997
Resolved
RENEW THE DETERIORATED VENT CLOSURE FOR THE TOP SIDE TANK #3 LOCATED ON THEPORT SIDE OF #3 CARGO HOLD._x001C_ ICLL 66 ANNEX I/19
Fire Fighting
Issued 26 February 1997
Resolved
RENEW/REPAIR THE DETERIORATED VENT CLOSURES AND VENTILATORS LOCATED ON THE FORWARD FORECASTLE._x001C_ ICLL 66 ANNEX I/19 _x001C_
Construction/Loadline
Issued 26 February 1997
Resolved
RENEW/REPAIR ALL DETERIORATED SUPPORT FRAMING FOR THE CARGO HATCH COVER COAMINGS THROUGHOUT THE VESSEL. _x001C_ ICLL I/1
Construction/Loadline
Issued 26 February 1997
Resolved
RENEW/REPAIR THE DETERIORATED BULWARK FRAMING LOCATED ON THE FORECASTLE._x001C_ ICLL 66 ANNEX I/25
Fire Fighting
Issued 26 February 1997
Resolved
RENEW/REPAIR THE DETERIORATED VENT CLOSURE LOCATED ON THE PORT SIDE OF THE FORECASTLE, OUTBOARD OF THE MOORING BITS._x001C_ ICLL 66 ANNEX I/19
Accommodation/Occupational Safety
Issued 26 February 1997
Resolved
RENEW AS ORIGINAL WITH FIXED PIPING THE DISCHARGE PIPING FOR THE FORWARD AND AFT REEFER COMPRESSOR COOLERS LOCATED ON THE PORT SIDE, FORWARD, AFT BOATSWAIN STORES._x001C_ SOLAS 74 (AMENDED) I/11(a)
Fire Fighting
Issued 26 February 1997
Resolved
RENEW THE MISSING CLOSURE DOG FOR THE WEATHER TIGHT HATCH LOCATED ON THE FORWARD FORECASTLE._x001C_ ICLL 66 ANNEX I/18
Construction/Loadline
Issued 26 February 1997
Resolved
NOTED SEVERE PITTING ON THE FORECASTLE. HAVE DECK PLATING GAUGED AND PROVIDE RESULTS OF THE GAUGING REPORT AND CLASS RECOMENDATIONS. _x001C_ ICLL 66 ANNEX I/19
Construction/Loadline
Issued 26 February 1997
Resolved
RENEW/REPAIR THE DETERIORATED BULK HEAD OF THE #1 DECK HOUSE STBD SIDE._x001C_ ICLL 66 ANNEX I/1
Fire Fighting
Issued 26 February 1997
Resolved
RENEW AS ORIGINAL THE DETERIORATED FIREMAIN PIPING LOCATED ON THE FORWARD STARBOARD BOAT DECK. HYDRANT IS COMPLETELY SEVERED FROM FIREMAIN._x001C_ SOLAS 74 (AMENDED) II-2/21
Lifesaving
Issued 26 February 1997
Resolved
RENEW/INSTALL THE HYDROSTATIC RELEASE FOR THE PORT LIFE RAFT._x001C_ SOLAS 74 (AMENDED) III/19.9.1
Fire Fighting
Issued 26 February 1997
Resolved
RENEW THE BROKEN/INOPERABLE FIREHOSE BOX LOCATED FORWARD OF THE #2 CARGO HOLD._x001C_ SOLAS 74 (AMENDED) II-2/21
Fire Fighting
Issued 26 February 1997
Resolved
RENEW AS ORIGINAL THE DETERIORATED FIREMAIN PIPING LOCATED ON THE STARBOARDSIDE, FORWARD OF CARGO HOLD #2._x001C_ SOLAS 74 (AMENDED)II-2/21
Lifesaving
Issued 26 February 1997
Resolved
INSTALL MACHINERY GUARDS ON THE EMERGENCY FIRE PUMP._x001C_ SOLAS 74 (AMENDED) I/11(a)
Construction/Loadline
Issued 26 February 1997
Resolved
RENEW/REPAIR THE DETERIORATED OVERHEAD IN THE AFT BOATSWIN STORAGE SPACE LOCATED ON THE STARBOARD AFT AT SERN OF VESSEL._x001C_
Accommodation/Occupational Safety
Issued 26 February 1997
Resolved
RENEW AS ORIGINAL THE DETERIORATED DRAIN PIPE LOCATED ON THE STARBOARD SIDE, AFT OF THE BOATSWAIN STORES._x001C_ ICLL 66 ANNEX I/1
Engineering
Issued 26 February 1997
Resolved
RENEW AS ORIGINAL THE DETERIORATED MAIN ENGINE SEA WATER COOLING PIPE FOR THE MAIN ENGINE LOCATED ON THE LOWER LEVEL OF THE ENGINE ROOM, INBOARD OF THE MAIN ENGINE SEA WATER COOLING PUMP._x001C_ SOLAS 74 (AMENDED) I/11(a)
Lifesaving
Issued 26 February 1997
Resolved
ENSURE ALL OXYGEN, ACETYLENE, AND FREON COMPRESSED GAS CYLINDERS THROUGHOUTTHE VESSEL ARE SECURLEY STORED IN THE DESIGNATED STORAGE SPACE._x001C_ SOLAS 74 (AMENDED) I/11(a)
Accommodation/Occupational Safety
Issued 26 February 1997
Resolved
RENEW AS ORIGINAL THE OVERBOARD DISCHARGE PIPE FOR THE REFRIGERATION/AIR CONDITIONING SYSTEM LOCATED ON THE LOWER LEVEL OF THE ENGINE ROOM, PORT SIDE, OUTBOARD OF THE MAIN ENGINE._x001C_ SOLAS 74 (AMENDED) I/11 (a)
Accommodation/Occupational Safety
Issued 26 February 1997
Resolved
RENEW AS ORIGINAL THE SEVERLY DETERIORATED DRAIN PIPING LOCATED IN THE OVERHEAD OF THE UPPER LEVEL OF THE ENGINE ROOM._x001C_ SOLAS 74 I/11(u)
Construction/Loadline
Issued 26 February 1997
Resolved
RENEW/REPAIR ALL DETERIORATED BULWARK SUPPORT FRAMING THROUGHOUT THE MAIN DECK._x001C_ ICLL ANNEX I/25
Fire Fighting
Issued 26 February 1997
Resolved
RENEW AS ORIGINAL THE DETERIORATED FIREMAIN PIPING LOCATED ON THE STARBOARDSIDE OF CARGO HOLD NO1._x001C_ SOLAS 74 (AMENDED) II-2/21
Construction/Loadline
Issued 26 February 1997
Resolved
RENEW THE MISSING DOGS FOR THE WEATHER TIGHT HATCH LOCATED ON THE PORT SIDEOF THE POOP DECK._x001C_ ICLL 66 ANNEX I/18
Fire Fighting
Issued 26 February 1997
Resolved
RENEW THE SEVERLY DETERIORATED VENT AND CLOSURE LOCATED ON THE AFT STBD SIDE OF THE BOAT DECK._x001C_ SOLAS 60 II/47(a)
Accommodation/Occupational Safety
Issued 26 February 1997
Resolved
RENEW AS ORIGINAL THE DETERIORATED ANCHOR WASH PIPING LOCATED IN THE FORECASTLE._x001C_ SOLAS 74 (AMENDED) I/11(a)
Fire Fighting
Issued 26 February 1997
Resolved
RENEW THE INOPERABLE FIRE HOSE BOX LOCATED ON THE 01 DECK FORWARD OF THE MAIN HOUSE._x001C_ SOLAS 74 (AMENDED) II-2/21
Fire Fighting
Issued 26 February 1997
Resolved
RENEW AS ORIGINAL DETERIORATED/HOLED FIREMAIN PIPING LOCATED ON THE STARBOARD SIDE BRIDGE WING._x001C_ SOLAS 74 (AMENDED) II-2/21
Lifesaving
Issued 26 February 1997
Resolved
REMOVE ALL EXCESS OIL FROM THE ENGINE ROOM BILGES, ENGINE CASING, ENGINE ROOM DECK PLATES, AND AND SURROUNDING MACHINERY IN THE ENGINE ROOM. THE SLOP TANK MUST BE LESS THAN 50% FULL PRIOR TO DEPARTURE._x001C_ SOLAS 74 (AMENDED) I/11(a)
Fire Fighting
Issued 26 February 1997
Resolved
RENEW AS ORIGINAL THE MISSING SEAWATER COOLING PIPE FOR THE EMERGENCY FIRE PUMP._x001C_ SOLAS 74 (AMENDED) II-2/21
Fire Fighting
Issued 26 February 1997
Resolved
RENEW/REPAIR THE DETERIORATED VENTILATOR AND CLOSURE LOCATED ON THE AFT STARBOARD SIDE OF THE POOP DECK._x001C_ ICLL 66 ANNEX I/19
Engineering
Issued 26 February 1997
Resolved
RENEW/REPAIR THE DETERIORATED/HOLED SEA WATER COOLING PIPE FOR THE DECK WINCHES LOCATED ON THE PORT SIDE OF CARGO HOLD #3._x001C_ SOLAS 74 (AMENDED) I/11(a)_x001C_ _x001C_
Fire Fighting
Issued 26 February 1997
Resolved
RENEW REPAIR THE INOPERABLE VENT CLOSURE LOCATED ON THE PORT SIDE FORWARD OF THE FIRE CONTROL PLAN._x001C_ SOLAS 60 II/47(a)
Electrical
Issued 3 January 1997
Resolved
Prove proper operation of reverse power relay to diesel generators. SOLAS 60/I/10.
Lifesaving
Issued 3 January 1997
Resolved
Install limit switches on port & stbd lifeboat davits. SOLAS 60/III/36K
Electrical
Issued 3 January 1997
Resolved
Repair RPM indicator to stbd diesel generator. SOLAS 60/I/10.
Deck/Cargo
Issued 3 January 1997
Resolved
Crop and renew all wasted hydraulic lines for cargo winches and hatch coveroperating winches. This includes all ground tackle hydraulic lines and return lines that run fwd/aft iaw class rpt. SOLAS 60/I/10.
Engineering
Issued 3 January 1997
Resolved
Clean and repair guage glasses of all storage and expansion tanks for cooling water lube and fuel oil tanks. SOLAS 60/I/10.
Construction/Loadline
Issued 3 January 1997
Resolved
Make permanent repairs to wasted general service/fire pump suction piping and main engine sea water cooling piping. SOLAS 60/I/10.
Engineering
Issued 3 January 1997
Resolved
Make permanent repair to burner system to boiler/demonstrate running in automatic condition. SOLAS 60/I/10.
Electrical
Issued 3 January 1997
Resolved
Provide proper light covers for all lights throughout ship. SOLAS 60/II/27(a).
Accommodation/Occupational Safety
Issued 3 January 1997
Resolved
Crop and renew all wasted and patched piping in crews toilet space. ILO 147.
Engineering
Issued 3 January 1997
Resolved
Make permanent repairs to wasted foundation for main engine sea water cooling pump and general service fire pump. SOLAS 60/I/10
Lifesaving
Issued 3 January 1997
Resolved
Replace missing reflective tape on all lifejackets, lifebuoys and lifeboats. SOLAS 60/III/4c
Lifesaving
Issued 3 January 1997
Resolved
Classification society to complete full survey of deck, machinery and lifesaving equipment. Provide results to USCG inspectors. USCG to conductfull annual PSC exam upon completion of class survey and appropriate repairs.
Lifesaving
Issued 3 January 1997
Resolved
Make permanent repairs to stbd lifeboat cable reels. SOLAS 60/III/4.
Lifesaving
Issued 3 January 1997
Resolved
Replace wasted grab rail on port and stbd lifeboats. SOLAS 60/III/4.
Lifesaving
Issued 3 January 1997
Resolved
Replace lights for lifebuoys aft of bridge on lifeboat deck. SOLAS 60/III/4.
Lifesaving
Issued 3 January 1997
Resolved
Renew port and starboard lifeboat falls. SOLAS 60/III/4c
Lifesaving
Issued 3 January 1997
Resolved
Replace wasted wood supports on port and starboard lifeboat lifelines. SOLAS 60/III/4.
Lifesaving
Issued 3 January 1997
Resolved
Replace all lifejackets iaw Safety Equipment Certificate. SOLAS 74 AMD/ III/19.2.
Accommodation/Occupational Safety
Issued 3 January 1997
Resolved
Remove all unauthorized personnel from vsl's hospital space. ILO 147.
Lifesaving
Issued 3 January 1997
Resolved
Make permanent repairs to lifebuoy quick release on stbd bridge wing. SOLAS 60/III/4.
Unknown
Issued 1 May 1996
Resolved
GENERAL HOUSEKEEPING OF MACHINERY SPACE UNSAT. SOLAS 74/78 R II 7 PART C
Fire Fighting
Issued 1 May 1996
Resolved
PROVE PROPER OPERATION OF EMERGENCY FIRE PUMP. SOLAS 74/78Rii Rii2/6
Unknown
Issued 1 May 1996
Resolved
REMOVE EXCESSIVE OIL FROM MACHINERY SPACE BILDGE SOLAS 74/78 R 11-1 PART C
Unknown
Issued 1 May 1996
Resolved
PROVE PROPER OPERATION OF OWS
Engineering
Issued 1 May 1996
Resolved
PROPERLY INSTALL FLAME SCREENS ON FUEL TANK VENTS
Accommodation/Occupational Safety
Issued 1 May 1996
Resolved
PROVE PROPER OPERATION OF THE MSD
Accommodation/Occupational Safety
Issued 6 November 1995
Resolved
MAKE REPAIRS TO ALL WATER TIGHT FITTINGS._x001C_ DOORS, VENTS AND BULKHEADS NOT WATER TIGHT. CLASS TO VERIFIY REPAIRS.
Deck/Cargo
Issued 6 November 1995
Resolved
MAKE REPAIRS TO WASTAGE AT ANCHOR AND MOORING WINDLASS FOUNDATION. CLASS TOVERIFY REPAIR.
Fire Fighting
Issued 6 November 1995
Resolved
REPAIR FIRE MAIN SYSTEM._x001C_ (PIN HOLE LEAKS, SOFT PATCHS, AND VALVES PAINTED SHUT)_x001C_ (CLASS TO VERIFY REPAIR)
Fire Fighting
Issued 6 November 1995
Resolved
SERVICE ALL FIRE EXTINGUSHERS AND PLACE ON STATION._x001C_ (FIRE EXTINGUISHERS NOT ON STATION, BEYOND SERVICE DATE AND DISCHARGED)_x001C_ (CLASS TO VERIFY SERVICABILITY)
Engineering
Issued 6 November 1995
Resolved
REPAIR LEAKING VALVES ON FUEL OIL TANK._x001C_ (CLASS TO VERIFY REPAIR)
Lifesaving
Issued 6 November 1995
Resolved
REMOVE OILY RAGS & CLEAN CONTROL ROOM. POOR HOUSKEEPING. (OILY RAGS STREWN ABOUT THE ENGINE CONTROL ROOM)
Engineering
Issued 6 November 1995
Resolved
MAKE REPAIRS TO LOWER LEVEL ENGINE ROOM RETURN WATER LINE. LEAKING SOFT PATCH. CLASS TO VERIFIY REPAIR.
Deck/Cargo
Issued 6 November 1995
Resolved
MAKE PERMANENT REPAIR TO SOFT PATHCES ON HYDRAULIC RETURN LINE TO ANCHOR WINDLASS._x001C_ CLASS TO VERIFY REPAIRS.
Construction/Loadline
Issued 6 November 1995
Resolved
REPAIR WASTED DECK FITTINGS (EG., BITTS AND CHOCKS)_x001C_ CLASS TO VERIFIY.
Accommodation/Occupational Safety
Issued 6 November 1995
Resolved
CLEAN SPILLED FUEL OIL ON DECK IN MAIN PASSAGEWAY/CREW LIVING AREA._x001C_ FIRE SAFETY HAZARD.
Accommodation/Occupational Safety
Issued 6 November 1995
Resolved
REPAIR HOLED GREY WATER PIPING (OVERHEAD MAIN DECK PASSAGEWAY AND DRY FOOD STORES). CLASS TO VERIFIY REPAIRS.
Lifesaving
Issued 6 November 1995
Resolved
POST MISSING INSTRUCTION FOR LIFE RAFTS._x001C_
Electrical
Issued 6 November 1995
Resolved
PROVIDE MISSING NON-CONDUCTIVE MATTING FOR CONTROL ROOM (ENGINE ROOM), AND BATTERY ROOM._x001C_
Lifesaving
Issued 6 November 1995
Resolved
STOCK LIFE BOATS WITH REQUIRED MISSING EQUIPMENT._x001C_ CLASS TO VERIFIY.
Lifesaving
Issued 6 November 1995
Resolved
REPAIR OR REPLACE MISSING HAND RAILS IN ENGINE ROOM AND MAIN DECK._x001C_ CLASS TO VERIFY REPAIR.
Lifesaving
Issued 6 November 1995
Resolved
POST MISSING INSTRUCTIONS FOR BOTH LIFE BOATS._x001C_
Accommodation/Occupational Safety
Issued 6 November 1995
Resolved
REPAIRE GRAY WATER DRAIN LINE LEAKING IN DRY STORES ROOM._x001C_ CLASS TO VERFIY.
Accommodation/Occupational Safety
Issued 6 November 1995
Resolved
REMOVE UNIDENTIFIED CYLINDERS FROM LIVING SPACE._x001C_ (ACETYLENE, OIL, UNKNOWN CYLINDERS IN LIVING AREA)
Accommodation/Occupational Safety
Issued 6 November 1995
Resolved
CLEAN AND REMOVE "LIVE IN" CREWMAN FROM HOSPITAL SPACE._x001C_ (SECOND MATE LIVING IN SPACE)
Electrical
Issued 6 November 1995
Resolved
REMOVE ALL UNUSED AND BARE ENDED ELECTRICAL WIRES THROUGHOUT THE SHIP._x001C_ UNPROTECTED WIRE EXPOSED.
Electrical
Issued 6 November 1995
Resolved
REPLACE PROTECTIVE COVERS ON LIGHTING THROUGHOUT THE VESSEL._x001C_ (LIGHT GUARDS MISSING)._x001C_
Documentation
Issued 21 September 1995
Resolved
VESSEL ENTERED THE PORT OF NEW YORK WITH OIL TRANSFER PROCEDURES MISSING CONTENTS REQUIRED BY 33 CFR 155.750.
Lifesaving
Issued 26 July 1995
Resolved
PROPERLY RIG WEAK LINKS ON PORT/STBD LIFERAFT._x001C_ _x001C_ _x001C_ _x001C_
Lifesaving
Issued 26 July 1995
Resolved
REPLACE BATTERIES ON LIFERING LIGHT, PORT SIDE LIFEBOAT DECK.
Accommodation/Occupational Safety
Issued 4 January 1995
Resolved
VESSEL DID NOT HAVE A POLLUTION PLACARD ONBROAD.
Accommodation/Occupational Safety
Issued 4 January 1995
Resolved
VESSEL WAS MISSING PLACARD FOR MSD.
Navigation
Issued 4 January 1995
Resolved
VESSEL CHARTS 11361,11364,11368 AND 11370 WERE NOT CURRENTLY CORRECTED FORTRANSITING THE AREA.
Navigation
Issued 4 August 1994
Resolved
VESSEL'S ECHO DEPTH SOUNDER WAS INOPERABLE.
Navigation
Issued 4 August 1994
Resolved
VESSEL'S CAPTAIN DID NOT REPORT TO THE COTP NEW ORLEANS THE ECHO DEPTH SOUNDER FAILURE.
Lifesaving
Issued 4 August 1994
Resolved
REPLACE WASTED SEA ANCHOR IN STARBOARD LIFEBOAT.
Lifesaving
Issued 4 August 1994
Resolved
REPLACE WASTED WOODEN STRUCTURES IN STARBOARD LIFEBOAT.
Accommodation/Occupational Safety
Issued 4 August 1994
Resolved
RENEW RAILS AROUND STARBOARD LIFEBOAT PLATFORM.
Lifesaving
Issued 4 August 1994
Resolved
PROVIDE RING BOUY LIGHTS FOR BOTH RING BOUYS ON LIFEBOAT DECK AS PER FIRE AND SAFETY PLAN.
Lifesaving
Issued 4 August 1994
Resolved
RENEW OUTBOARD HANDRAIL ON THE PORT LIFEBOAT.
Lifesaving
Issued 4 August 1994
Resolved
ATTACH ALL OARLOCKS IN STARBOARD LIFEBOAT.
Lifesaving
Issued 4 August 1994
Resolved
REPLACE WASTED SOLAS COVER IN STARBOARD LIFEBOAT.
Lifesaving
Issued 4 August 1994
Resolved
PROVIDE SOLAS COVER FRAME FOR STARBOARD LIFEBOAT.
Electrical
Issued 4 August 1994
Resolved
REMOVE DEAD END WIRES ON AFT LIFEBOAT DECK ON BOTH SIDES.
Lifesaving
Issued 4 August 1994
Resolved
PROVIDE A NEW SAIL FOR THE PORT LIFEBOAT.
Lifesaving
Issued 4 August 1994
Resolved
PROVIDE A NEW SOLAS COVER FOR THE PORT LIFEBOAT.
Lifesaving
Issued 4 August 1994
Resolved
PROVIDE SOLAS COVER FRAME FOR PORT LIFEBOAT.
Fire Fighting
Issued 4 August 1994
Resolved
REPLACE MISSING FIRE HOSE STATION ON PORT SIDE LIFEBOAT DECK.
Construction/Loadline
Issued 4 August 1994
Resolved
REPAIR HOLE IN BULKHEAD TO ENGINEROOM PORT SIDE LIFEBOAT DECK.
Construction/Loadline
Issued 4 August 1994
Resolved
PATCH HOLE IN BULKHEAD TO HOLD ACCESS BETWEEN #1 AND #2 CARGO HOLDS ON THE STARBOARD SIDE IN WAY OF STEP INTO DOOR.
Electrical
Issued 4 August 1994
Resolved
RENEW ALL ELECTRICAL LIGHTING IN THE FORECASTLE WITH ACCEPTABLE MARINE FIXTURES WITH GLASS GLOBE.
Construction/Loadline
Issued 4 August 1994
Resolved
RENEW BOTH CHAIN LOCKER HATCHES IN THE FORECASTLE.
Electrical
Issued 4 August 1994
Resolved
RENEW CABLE PIPING PORT SIDE FROM HOUSE TO FORECASTLE.
Construction/Loadline
Issued 4 August 1994
Resolved
RENEW CIRCULAR HATCH ON FORECASTLE AND REPLACE MISSING DOGS.
Construction/Loadline
Issued 4 August 1994
Resolved
RENEW MISSING DOG TO DOOR PORT SIDE BETWEEN CARGO HOLDS #3 & #4.
Construction/Loadline
Issued 4 August 1994
Resolved
RENEW DOGS (3) TO HATCH ENTRY INTO CARGO HOLD #4.
Electrical
Issued 4 August 1994
Resolved
REMOVE DEAD END WIRE IN PORT SIDE LINE STORAGE LOCKER BETWEEN CARGO HOLDS #3 & #4.
Electrical
Issued 4 August 1994
Resolved
PROVIDE GLOBES ON ELECTIRCAL LIGHTING IN ENGINEERING STORES ON MAIN DECK AND STEERING GEAR ROOM.
Fire Fighting
Issued 4 August 1994
Resolved
RENEW VENT DAMPERS TO A/C VENTING MAIN DECK ACCOMODATION SPACES.
Construction/Loadline
Issued 4 August 1994
Resolved
RENEW DOGS MISSING ON HATCH TO AFTER STEERING.
Fire Fighting
Issued 4 August 1994
Resolved
PROVIDE SPANNER WRENCHES FOR ALL FIRE STATIONS.
Lifesaving
Issued 4 August 1994
Resolved
RENEW BOTH HANDRAILS ON THE STARBOARD LIFEBOAT.
Construction/Loadline
Issued 4 August 1994
Resolved
RENEW WASTED WATERTIGHT DOOR ON FANTAIL PORT SIDE.
Construction/Loadline
Issued 4 August 1994
Resolved
RENEW WASTED WATERTIGHT DOOR PORT SIDE LIFE BOAT DECK.
Construction/Loadline
Issued 4 August 1994
Resolved
PROVIDE CLASSIFICATION SOCIETY EVALUATION REPORT ON SEAWORTHYNESS OF ALL CARGO HOLD HATCH COAMINGS WHERE STIFFINERS ARE WASTED.
Electrical
Issued 4 August 1994
Resolved
PROVIDE GLOBES ON ALL ELECTIRCAL LIGHTNG IN PORT SIDE LINE STORAGE LOCKER BETWEEN CARGO HOLDS #3 & #4.