PRIKONISSOS

PRIKONISSOS is a 1981 tank ship. The Coast Guard has recorded 55 inspections since 1990, most recently in June 2006, along with 44 deficiencies and 7 operational controls, 1 with no removal date recorded.

Records from 1990 to 2006. Most recent: inspection, 27 June 2006.

Built
1981
Last inspected
27 June 2006
Documentation
Not in the documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

7905510 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
354593
Flag
LIBERIA
—
Maury page id
psix-354593

Inspections, by type

…with no type recorded28
Years with a record 14 calendar years (1990–2006)
The 55 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 20 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it24870 - Simplified, Net Ton
24870 - Convention (Subpart B), Net Ton
67031 - Dead Weight, Ton
80668 - Displacement, Ton
36902 - Simplified, Gross Ton
36902 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

PREM MALA Tank Ship · MISLE 2281 · 7 June 2005 · activity 2386520

Inspection history · 55

27 June 2006 Deficiency Check
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2692851
5 June 2006 COC-TVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2667123
17 January 2006 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2568453
17 November 2005 Ballast Water Examination · Deficiency Check · Random ISPS/MTSA/PSC
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2536265
16 September 2005 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2494240
7 July 2005 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2418578
7 July 2005 ISPS III Exam · Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2418622
7 June 2005 Random ISPS/MTSA/PSC · MARPOL Annex I Examination · Ballast Water Examination · MARPOL Annex V Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2377113
7 June 2005 MARPOL Annex I Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2384071
7 June 2005 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2386520
26 May 2005 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2368540
21 May 2005 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2363845
19 May 2005 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2568458
17 May 2005 MARPOL Annex I Examination · Ballast Water Examination · MARPOL Annex V Examination · COC-TVE Renew
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2356686
23 March 2005 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2318104
21 March 2005 Administrative Inspection
Administrative · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2315287
1 March 2005 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2315175
22 February 2005 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2297441
21 February 2005 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2296390
5 January 2005 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2269439
8 November 2004 PII Safety Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2236740
5 November 2004 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2235230
28 July 2004 PII Safety Exam · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2147703
17 July 2004 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2136027
28 June 2004 ISPS II Exam
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2114800
28 May 2004 Certificate of Compliance
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2080582
28 June 2003 Annual Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1828168
12 April 2003 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1778261
12 February 2003 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1741717
5 February 2003 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1740032
27 May 2002 Tank Vessel Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1620457
13 May 2002 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1616198
6 May 2002 Ballast Water Examination · Periodic Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1613190
28 February 2002 Damage Survey
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1490215
28 February 2002 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1490328
11 February 2002 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1485337
27 November 2001 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 511678
2 July 2001 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 291519
24 May 2001 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 290260
24 May 2001 Tank Vessel Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1432513
9 May 2000 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 277710
9 May 2000 Tank Vessel Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1471894
9 November 1999 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 434372
6 October 1999 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 433138
27 March 1999 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 426876
27 March 1999 Tank Vessel Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1115122
17 January 1996 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 475483
24 July 1995 Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 685417
18 July 1995 Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 380750
15 December 1993 Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 453741
13 September 1993 Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 834668
26 April 1993 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 483298
18 August 1992 Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1265615
22 April 1991 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 463747
11 September 1990 Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1222726

Deficiency record · 44

Electrical › Electric Generation Source (service) › Panelboard
Issued 5 June 2006 Resolved
Ship electrical control panel in engine control room has panels that will not close.
Action required: 705 - Other - as specified
Due 19 June 2006
Resolved 24 June 2006
Fire Fighting › Structural - A Class Divisions › Flammable Liquids Storage Spaces
Issued 5 June 2006 Resolved
Fire doors do not shut completely on main deck from changing room to engine room and in the main stairway on B-deck, C-deck, and D-deck due to mechanical failures and unauthorized hold-backs.
Action required: 705 - Other - as specified
Due 19 June 2006
Resolved 24 June 2006
Resolution: Received attestation from BV that fire doors have been fixed.
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 17 November 2005 Resolved
Ascertain/Correct why steering unit is returning to 5 degree instead of 0 degree after controller is released. Additionally correct units cavitations on movement of unit. (only during remote steering test mode). Prior to departing the Port.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 18 November 2005
Resolution: Class report# 35A305
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 17 November 2005 Resolved
Ascertain and correct ioperative smoke detectors located throughout engine room. Test all units. Prior to departing the Port of NY
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 18 November 2005
Resolution: Class report# 35A305
Deck/Cargo › Inert Gas System › IGS Scrubber
Issued 17 November 2005 Resolved
Ascertain/correct incorrect reading oxygen @ scrubber analyzer on IGS panel located in IG room (when unit is spanned tested). Also remount the indicator unit (stuck on with electrical tape). To satisfaction of attending class surveyor
Condition: Unknown
Due 17 December 2005
Resolved 18 November 2005
Resolution: Class report# 35A305
Fire Fighting › Means of Escape › Doorways
Issued 7 June 2005 Resolved
Self closing door from engine room to changing room will not close properly due to latch not engaging door frame. Repair to the satisfaction of class prior to 14 JUN 2005.
Action required: 705 - Other - as specified
Due 14 June 2005
Resolved 10 June 2005
Resolution: Received Class report that door is operating properly.
Deck/Cargo › Cargo Heating › General
Issued 7 June 2005 Resolved
Unable to demonstrate operation of Thermo Boiler #1 due to motor for fan not being operational. From a static position it appears there are fuel leaks on the top of boiler adjacent to igniter. Prove proper operation of Thermo boiler to the satisfaction of class prior to 14 JUN 2005.
Action required: 705 - Other - as specified
Due 14 June 2005
Resolved 7 July 2005
Resolution: Recieved class report
Engineering › Lubricating Oil Service System › Purifier
Issued 7 June 2005 Resolved
Prove proper operation of #1 lube oil purifier to the satisfaction of class prior to 14 JUN 2005. SOLAS 60 Amend 1/11
Action required: 705 - Other - as specified
Due 14 June 2005
Resolved 10 June 2005
Resolution: Class provided report attesting to proper operation of purifier.
Deck/Cargo › Ballast › Piping
Issued 7 June 2005 Resolved
Permently repair ballast piping located forward of the starboard ballast pump in ballast pump room. Soft patch has been installed forward at hydraulic valve located on suctioin side of ballst pump . Make repairs to the satisfaction of class prior to 21 JUN 05
Action required: 705 - Other - as specified
Due 21 June 2005
Resolved 7 July 2005
Resolution: recieved class report
Deck/Cargo › Ballast › SBT
Issued 7 June 2005 Resolved
Submit for approval to the U.S. Coast Guard a plan that has been approved bythe classification society or flag rep to reduce to acceptabel levels the H2S and LEL. Additionally provide a report detailing the cause of the ballast tanks contamination. The above to be copleted prior to conducting cargo or departure from St. Croix.
Action required: 15 - Rectify deficiencies by next port
Due 7 June 2005
Resolved 10 June 2005
Resolution: Recieved and approved class approved plan for vessel to offload cargo and proceed to shipyard for inspection of vessels cargo and ballast tanks.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Pressure
Issued 17 May 2005 Resolved
Recharge dry powder extinguisher in paint locker. Space also protected by water spray system but portable dry chem has been discharged. To be corrected to the satisfaction of class or attending Coast Guard inspector.
Due 19 June 2005
Resolved 21 May 2005
Resolution: Extinguisher recharged.
Deck/Cargo › Vapor Control Systems › Vessel Vapor Overpressure/Vacuum Protection
Issued 17 May 2005 Resolved
Provide manual for pressure/vacuum valves in language of the crew or the vessel's working lanuguage of English as stated in SMS.
Action required: 705 - Other - as specified
Due 21 June 2005
Resolved 27 May 2005
Resolution: Received class survey attesting to the deficiency being resolved.
Deck/Cargo › Vapor Control Systems › Vessel Vapor Overpressure/Vacuum Protection
Issued 17 May 2005 Resolved
Conduct required maintenance of pressure/vacuum valves. Evidence of required maintenance to be provided prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 May 2005
Resolution: Maintenance logs produced verifying PV valves have been disassembled and cleaned per PV manufacturers operations manual.
Documentation › Manuals/Policy Documentation › Cargo/Ballast System Instruction Manual
Issued 17 May 2005 Resolved
Manual for "Vapour Alarm System" is for the type AUT-OP15, actual model on vessel is ESA VT60. Provide class or flag approved manual for "Vapour Alarm System" (vapor contol system) prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 May 2005
Resolution: Class verified correct manual for Vapour Alarm System is on board vessel.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 17 May 2005 Resolved
Fire control plan is in spanish. Provide fire control plan in official language of the crew, English, as stated in vessel's SMS.
Action required: 705 - Other - as specified
Due 19 June 2005
Resolved 21 May 2005
Resolution: Fire control plan provided in English.
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 17 May 2005 Resolved
Low level alarm on #1 steering gear not operational. Prove proper operation prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 May 2005
Deck/Cargo › Inert Gas System › Deck Distribution System
Issued 17 May 2005 Resolved
Provide manual for instruction and operation of deck distribution system referred to in class approved IGS manual prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 May 2005
Resolution: Material provided and inserted in IGS manual to the satisfaction of class.
Fire Fighting › Means of Escape › Doorways
Issued 17 May 2005 Resolved
Door from rope store into steering gear room will not open due to grate on floor blocking door. Prove full operation of door prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 May 2005
Resolution: grate removed door fully operational.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 17 May 2005 Resolved
Remove all cargo tank cleaning cans, approximately 40, from steering gear flat prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 May 2005
Resolution: Cans moved to forecastle storage space.
Fire Fighting › Fire Hoses › Connections
Issued 17 May 2005 Resolved
Fire hoses all have different size gaskets that prevent some of them from connecting to one another or to hydrants. Repair hoses to allow them to connect to one another and hydrants as designed.
Action required: 705 - Other - as specified
Due 28 May 2005
Resolved 27 May 2005
Resolution: rECIEVED FAX VIA CLASS ATTESTING TO ALL REPAIRS SATISFACTORY.
Operations/Management › Mandatory Ship Reporting Systems › Entry Report
Issued 1 March 2005 Resolved
Vessel gave late NOA.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 March 2005
Resolved 1 March 2005
Resolution: Vessel was to remain outside US waters until the required 24 hour period for notification has been met.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 8 November 2004 Resolved
Master's Panamanian endorsement did not recognize the correct national liscense. Vessel is to provide a copy by fax of the corrected Panamanian endorsement with the proper corresponding national liscense number.
Due 8 November 2004
Resolved 8 November 2004
Resolution: Recieved copy of the corrected Panamanian endorsment.
Navigation › Collision/Grounding Avoidance › Radar
Issued 28 July 2004 Resolved
Pilot reported radar down during transit into port. Primary + Secondary radars to be inspected by certified technicians and repaired. Techician's report to be received, reviewed and approved by COTP Baltimore prior to permission being granted to leave the Port of Baltimore.
Action required: 17 - Rectify deficiencies prior to departure
Due 29 July 2004
Resolved 1 August 2004
Resolution: Tech report received reviewed and approved by COTP Baltimore. Permission granted to depart.
Deck/Cargo › Inert Gas System › Deck Water Seal
Issued 28 May 2004 Resolved
Deck water seal line low flow deck seal alarm did not make automatic valves to close. Prove current installation manual test procedures are approved and meet class standards.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 June 2004
Resolved 18 July 2004
Resolution: Received class report approving current installation manual and test procedures.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Closure Devices
Issued 28 May 2004 Resolved
Have class survey frank valve indicators and annunciation pannel in CCR to ensure they reflect actual position of valves (open or closed)
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 June 2004
Resolved 18 July 2004
Resolution: Received class report verifying that valve indicators were repaired and operation of valves was found satifactory.
Construction/Loadline
Issued 11 February 2003 Resolved
Make corrections to the Load Line Certificate to reflect hull markings.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 February 2003
Resolution: BV Class surveryor onboard at time of inspection; surveryor made pen and ink change to loadline certificate.
Fire Fighting › Miscellaneous Items
Issued 5 February 2003 Resolved
Spanner wrench(s) required for "ready use" are missing from al interior & exterior fire hose boxes or hydrants. As required by Solas 60 Ch.II Reg.56(f). To be corrected prior to next U.S. Port, after sailing foreign. LEGACY COMPONENT DESC: Spanner Wrenches
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 February 2003
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 5 February 2003 Resolved
Visual alarm light not able to be seen from all areas where cargo transfer takes place. As required by 46 CFR 39.20-7(c)(3). To be corrected prior to next cargo loading in a U.S. port. Class society to attest to the satisfaction condition of the same. LEGACY COMPONENT DESC: Alarms
Action required: 705 - Other - as specified
Resolved 6 February 2003
Resolution: Rcvd class survey report attesting to an additional visual alarm light for high level alarm on deck fitted and tried out satisfactory.
Lifesaving › Hand Flares › Quantity
Issued 5 February 2003 Resolved
(01) required parachute flare missing from Nav bridge. As required by Solas 60 Ch.III Reg.24. To be corrected prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 February 2003
Resolution: Rcvd class report verifying that required flare o/b vsl.
Lifesaving › Inflatable Liferafts
Issued 5 February 2003 Resolved
All liferafts (05) total are off the vsl being serviced. As required by Solas 60 Ch.III Reg.4. To be corrected prior to departure. LEGACY COMPONENT DESC: Servicing
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 February 2003
Resolution: Rcvd service rpt''s for all liferafts, verifying o/b & in satisfactory condition.
Navigation › Piloting/Steering
Issued 5 February 2003 Resolved
Rudder angle indicator differs from 3 to 4 degrees on the port direction; from what is on the rudder post and what is on the bridge helm. As required by Solas 60 Ch.II Reg.29(a)(iv). To be corrected prior to departuer. Class society to attest to the satisfaction condition of the R.A.I. LEGACY COMPONENT DESC: Rudder Angle Indicator
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 February 2003
Resolution: Rcvd class survey rpt attesting to the vsl''s steering gear control arm link was adjusted and found to be w/in 1.5 degrees; and thus, in satisfactory condition.
Fire Fighting › Fixed Deck Foam System › Piping
Issued 5 February 2003 Resolved
The vsl's fixed foam fire extinguishing system not working due to a blown pressure pipe located in the foam room. A requirement of Solas 60 Ch.II Reg.60(a). To be corrected prior to departure. Class society to attest to the satisfaction condition of the system.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 February 2003
Resolution: Rcvd class survey rpt attesting to the satisfactory condition of the vsl''s fixed foam fire fighting system.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 5 February 2003 Resolved
All portable fire fighting extinguishers are past due for servicing. A requirement of Solas 60 Ch.II Reg57(d). To be corrected prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 February 2003
Resolution: Rcvd service reports verifying that all portable f/f ext''s are o/b the vsl & in satisfactory condition.
Documentation › Logs/Records › Ballast Water Reporting Form
Issued 5 February 2003 Resolved
Vessel failed to complete a Ballast water report and fax/e-mail it to the NBIC for entry into the Port of Philadelphia after sailing from a foreign port. A requirement of 33 CFR 151 Subpart D. To be corrected prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 February 2003
Resolution: Rcvd faxed copy of the completed B/W rpt.
Fire Fighting › Self-contained Breathing Apparatus › Air Bottle
Issued 5 February 2003 Resolved
All fire fighting breathing apparatus's used for desginated fireman's outfit(s) are past due for servicing. A requirement of Solas 60 Ch.II Reg.63(b). To be corrected prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 February 2003
Resolution: Rcvd service rpt verifying all b/a''s are o/b the vsl & in satisfactory condition.
Navigation › Piloting/Steering
Issued 10 May 2002 Resolved
Vessel was authorized to deviate from the requirements of 33 CFR 164.35(d) and depart the Port of Corpus Christi with an inoperable gyrocompass with the understanding that the equipment will be operational prior to departure from its next port of call. LEGACY COMPONENT DESC: Gyro Compass
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 May 2002
Resolution: During TVE, verified satisfactory operation of gyrocompass; also reviewed technicians report.
Electrical
Issued 6 October 1999 Resolved
REPAIR AND CALIBRATE THE EDG GOVERNOR AND BATTERY MAINTENANCE. BATTERY CELLS WERE WEAK AND GENERATOR RPMS LOW DUE TO STICKING AND MISADJUSTED GOVERNOR, REQUIRING MANUAL ADJUSTMENT. SOLAS (Unamended)II-1/43/3.1.2
Condition: Unknown
Due 10 November 1999
Resolved 10 November 1999
Lifesaving
Issued 6 October 1999 Resolved
PROVIDE A WEAK LINK AND RE-ATTACH THE STBD. 01 DECK LIFERAFT PAINTER CORRECTLY ALLOWING HYDROSTATIC RELEASE AND SUBMERGED INFLATION, TO THE SATISFACTION OF THE COAST GUARD. SOLAS 74(Unamended) III/29
Condition: Unknown
Due 6 December 1999
Resolved 6 December 1999
Fire Fighting
Issued 6 October 1999 Resolved
REPAIR TO FULL OPERATING PRESSURE CAPABILITY THE #2 SHIPS' MAIN FIRE PUMP, SPECIFICALLY THE WORN BEARINGS. SOLAS 74(Allships) II-2/4/2.12
Condition: Unknown
Due 10 November 1999
Resolved 10 November 1999
Navigation
Issued 6 October 1999 Resolved
REPAIR THE STEERING GEAR REMOTE BRIDGE "LOSS OF POWER" AND LOW HYDRAULIC FLUID AUDIBLE SPEAKER ALARM. SOLAS 74(Unamended) II-1/29/8.4
Condition: Unknown
Due 10 November 1999
Resolved 10 November 1999
Fire Fighting
Issued 6 October 1999 Resolved
REPAIR THE CO2 ROOM VENTILATION FAN AND PROVIDE SERVICE REPORT AND SMS NON-CONFORMITY REPORT TO THE SATISFACTION OF THE COAST GUARD. _x001C_ SOLAS 74 (unamended) II-2/1/13
Condition: Unknown
Due 10 November 1999
Resolved 10 November 1999
Lifesaving
Issued 6 October 1999 Resolved
HAVE CLASS ADDRESS THE DISPARITY BETWEEN AGGREGATE LIFERAFT CAPACITIES ON BOARD AND THE SOLAS SAFETY EQUIPMENT CERTIFICATE. REPORT TO BE SENT TO THE COAST GUARD. SOLAS 74(Unamended) I/12,14
Condition: Unknown
Due 6 December 1999
Resolved 6 December 1999
Documentation
Issued 27 March 1999 Resolved
VESSEL MUST HAVE ORIGINAL COFR CERTIFICATE ONBOARD PRIOR TO NEXT U.S. PORT.VESSEL DOES HAVE VALID COFR AS PER NPFC. 31MAR99 VESSEL HAS COFR ONBOARD. DEFICIENCY CLEARED.
Condition: Unknown
Due 31 March 1999
Resolved 31 March 1999
Construction/Loadline
Issued 18 July 1995 Resolved
Port side plimmsol and loadline mark were not painted. Therefore, the color of the plimsoll was not in contrast with the hull.
Condition: Unknown
Due 20 July 1995
Resolved 20 July 1995

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.