ZERA L. TANNER

Built
1989
Last inspected
12 February 2026
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the School Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 12 February 2026
…with no type recorded4
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8835217
354827
Flag
UNITED STATES
Maury page id
psix-354827

Documentation record

Tonnage as PSIX records it13319 - Regulatory (Subpart C or D), Gross Ton
12542 - Convention (Subpart B), Gross Ton
7158 - Regulatory (Subpart C or D), Net Ton
3762 - Convention (Subpart B), Net Ton
16278 - Displacement, Ton
6864 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 41 inspections, each with its date, unit and type; 64 deficiencies with the resolution recorded against each, 5 without one; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 41

12 February 2026 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 8309893
16 March 2025 In-Service Inspection · Plan Review (Other than "T") · COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8112945
7 January 2025 Underwater Inspection in lieu of Drydock · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8060025
16 July 2024 Administrative Inspection
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7959878
4 April 2024 Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7891592
27 March 2024 COI Inspection · MTSA/ISPS Verification · DAPI Audit
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7885572
20 June 2023 Administrative Inspection
Administrative · Activities Europe · Activity 7719673
17 May 2023 Damage Survey
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7690357
15 March 2023 COI Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7651475
3 November 2022 Administrative Inspection
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7591866
27 June 2022 Administrative Inspection
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7488403
21 June 2022 Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7495892
13 April 2022 DAPI Audit
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7430810
17 February 2022 MTSA/ISPS Verification · COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7397705
5 January 2022 Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7380105
22 November 2021 Damage Survey
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7355487
19 October 2021 Administrative Inspection
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7336381
3 May 2021 Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7187844
1 March 2021 MTSA/ISPS Verification · COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7148323
2 November 2020 Administrative Inspection
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7088271
30 March 2020 COI Inspection · Underwater Inspection in lieu of Drydock · MARPOL Annex IV Survey · MARPOL Annex I Examination · MARPOL Annex VI Survey · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6933387
30 October 2019 Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6846201
27 August 2019 Administrative Inspection
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6796494
17 June 2019 Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6812993
7 June 2019 Administrative Inspection
Administrative · Activities Europe · Activity 6717447
5 April 2019 Administrative Inspection
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6659562
15 March 2019 MARPOL Annex IV Survey · MARPOL Annex I Examination · Examination of Repairs · MTSA/ISPS Verification · MARPOL Annex VI Survey · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6643141
27 August 2018 Damage Survey
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6524432
9 April 2018 Deficiency Check · MARPOL Annex I Examination · COI Inspection · DAPI Audit · MARPOL Annex IV Survey · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6387847
22 August 2017 Drydock Exam · Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6249631
28 July 2017 Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6223622
25 July 2017 Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6220002
6 July 2017 Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6214362
9 March 2017 MTSA/ISPS Verification · Examination of Repairs · COI Inspection · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6102391
29 July 2016 Administrative Inspection
Administrative · Activities Europe · Activity 5956461
25 July 2016 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5952714
15 July 2016 Type not recorded
No type recorded · Activities Europe · Activity 5941395
3 June 2016 Excursion Permit
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 5899528
31 May 2016 Deficiency Check · In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5893060
19 May 2016 Administrative Inspection
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 5881474
4 April 2016 MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 5835103

Deficiency record · 64

11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 9 October 2025 No resolution recorded
Tests and inspections of the lifesaving equipment shall be carried out during each inspection for renewal of certification and periodic inspection, and shall include, as applicable, a demonstration of — (1) The proper condition and operation of the survival craft and rescue boat launching appliances at loads ranging from light load to full load. Multiple crew members were required to manipulate falls and remote brake release wires during lowering and retrieval of lifeboats #1 and #4. Additionally, lowering speed of lifeboats is in question which measured at approximately .03 meters per second (6 feet per minute). Demonstrate satisfactory tests of launching appliances to satisfaction of MI prior to vessel operations. 46 CFR 199.45(b), 705c
Action required: 705 - Other - as specified
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 10 July 2025 No resolution recorded
Acceptance of lifesaving appliances and arrangements will remain in effect unless—(1) The OCMI deems their condition to be unsatisfactory or unfit for the service intended. During follow-on inspection, lifeboat davits #2 and #3 were found with falls chaffing against the davit structure as a result of insufficient clearance at the davit pedestal on #2 and aft pad eye bracket where the falls terminate on #3. Due to the observed condition, the following restrictions are applied until repairs are made to the satisfaction of the OMCI: - Vessel is required to lock/tag out davits #2 and #3 to prevent inadvertent use - Vessel is limited to carry 186 total persons onboard (including crew) 46 CFR 199.40(f)(1)
Action required: 705 - Other - as specified
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 June 2025 Resolved
Electric installations on vessels must ensure: Protection of passengers, crew, other persons, and the vessel from electrical hazards. Shaft Alley Electric Panel PF411 was not properly secured. Repair to the satisfaction of the MI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2025
Resolved 10 July 2025
Resolution: Secured panel
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 June 2025 No resolution recorded
Periodic Safety tests must demonstrate the proper operation of the primary and alternate controls, alarms, power sources, transfer override arrangements, interlocks, and safety controls. Systems addressed must include fire detection and extinguishing, flooding safety, propulsion, maneuvering, electric power generation and distribution, and emergency internal communications. PSTPs did not match expected operation of the equipment. Update PSTPs and submit for approval within 90 days.
Action required: 705 - Other - as specified
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 25 June 2025 No resolution recorded
Machinery driving forced-draft and induced-draft fans, fuel-oil transfer pumps, fuel-oil unit and service pumps, and similar fuel-oil pumps must be fitted with remote controls from a readily accessible position outside the space concerned so that the fans or pumps may be stopped in case of fire in the compartment in which they are located. The controls must be suitably protected against accidental operation and against tampering and must be suitably marked. Fuel Oil Purifiers did not have remote stops. Add remote stops prior to credit drydock.
Action required: 705 - Other - as specified
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 25 June 2025 Resolved
The inspectors will examine all pumps, hose, and other fire apparatus and will see that the hose is subjected to a pressure of 100 pounds to the square inch at each annual inspection and that the hose couplings are securely fastened. Vessel’s emergency fire pump sea water suction remote control valve is inoperable. Repair to satisfaction of MI
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 August 2025
Resolution: Valve repaired
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 25 June 2025 Resolved
The inspectors will examine all pumps, hose, and other fire apparatus and will see that the hose is subjected to a pressure of 100 pounds to the square inch at each annual inspection and that the hose couplings are securely fastened. Vessel’s fire and general service pump discharge valve does not close due to “valve jamming” error. Repair to satisfaction of MI.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 August 2025
Resolution: Actuator was replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 June 2025 Resolved
04 remote fuel shutoff valves did not properly close. - SSDG DFM Day tank #1 High Suction (2-144-1) - DFM Storage Tank - Transfer (5-47-1) - HFO Settling Tank - Low Suction (3-144-1) - HFO Storage Tank - Transfer (3-144-4) Show proper operation to the attending MI. 46CFR61.20-3(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 June 2025
Resolution: Repaired valves
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 June 2025 Resolved
Life jackets are missing in ECR. Provide proper amount and type life jackets in the ECR. 46CFR167.35-1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 June 2025
Resolution: Lifesaving equipment onboard
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 June 2025 Resolved
During testing of machinery intermittent ground faults were found on 1S and 2S bus. Identify and correct ground faults to the satisfaction of the attending MI. 46CFR111.05-3
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 August 2025
Resolution: Ground discovered and repaired
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 June 2025 Resolved
During M/E testing a cooling water leak was found on the #2 cylinder. Repair leak to the satisfaction of the attending MI. 46CFR58.05-1(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 June 2025
Resolution: Leak repaired
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 June 2025 Resolved
Space heater found through out the ship improperly wired. Remove all portable space heaters on board the vessel. 46CFR167.40-1(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 June 2025
Resolution: Heaters removed
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 June 2025 Resolved
HFO slop pump and sentry alarm system found wired through extension cord to power outlet. Properly wire systems ensuring proper wiring and over current protection. 46CFR167.40-1(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 July 2025
Resolution: Installed wiring
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 June 2025 Resolved
Control light indicators at shaft alley control station do not work. Repair to the satisfaction of the attending MI. 46CFR167.40-1
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 August 2025
Resolution: Light replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 June 2025 Resolved
Main engine side local panel selector switch not properly labeled to determine local or remote controls selected. Properly label selector switch to the satisfaction of the attending MI. 46CFR167.15-20(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 July 2025
Resolution: Labels installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 12 June 2025 No resolution recorded
CPP OD box has small leaking coming from fwd and aft seals. Proper repairs to be completed prior to next credit dry dock. Due October 2027 46CFR167.15-25
Action required: 705 - Other - as specified
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 12 June 2025 Resolved
Tests and inspections of the lifesaving equipment shall be carried out during each inspection for renewal of certification of the proper condition and operation of lifeboats and rescue boats. The following conditions were observed: Rescue boat #1 has two areas of exposed fiberglass on the hull from damage. Rescue boat #2 was found full of water in all compartments with water was seeping through cracks in the starboard side hull and a leaking sponson. Make authorized repairs to satisfaction of MI. 46 CFR 199.45(b)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 July 2025
Resolution: Repairs made to rescue boats and vessel found dry.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 12 June 2025 Resolved
Tests and inspections of the lifesaving equipment shall be carried out during each inspection for renewal of certification of the proper condition and operation of the survival craft and rescue boat launching appliances. During lowering, lifeboat davits #1 & #3 were noted with seized sheeves on the davit arms. Lifeboat davit #2 was found with a frayed remote brake release wire. Additionally, all lifeboat davit falls and fittings need to be greased. Service launching appliances to satisfaction of MI. 46 CFR 199.45(b)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 August 2025
Resolution: Davits have been serviced.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 12 June 2025 Resolved
Electric installations and electric equipment must be inspected at the inspection for certification and periodic inspection to determine mechanical and electrical condition and performance. Emergency lighting throughout accommodation spaces was found extinguished. Repair to satisfaction of MI. 46 CFR 110.30-5
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 August 2025
Resolution: Bulbs replaced for extinguished emergency lighting.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 12 June 2025 Resolved
Tests and inspections of the lifesaving equipment shall be carried out during each inspection for renewal of certification of the proper condition of flotation equipment such as lifebuoys, lifejackets, immersion suits, work vests, lifefloats, buoyant apparatus, and associated equipment. Immersion suits have not been maintained/pressure tested. Test or replace immersion suits to satisfaction of MI. 46 CFR 199.45(b)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 July 2025
Resolution: Immersion suits pressure tested.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 June 2025 Resolved
At each inspection for certification and periodic inspection the marine inspector must conduct such tests and inspections of the main propulsion and auxiliary machinery and of its associated equipment, including the fluid control systems, as they feel necessary to check safe operation. During testing, directional control valve for anchor windlass did not stay in the neutral position allowing unintended movement of the anchor with no valve manipulation. Repair to satisfaction of MI. 46 CFR 61.20-3(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 June 2025
Resolution: Witnessed satisfactory test of anchor windlass.
10 - Safety of Navigation › N/A - No Subsystem › Electronic charts (ECDIS)
Issued 12 June 2025 Resolved
No person may operate or cause the operation of a vessel unless the vessel has the marine charts, publications, and equipment as required by §§ 164.33 through 164.41 of this part. Vessel’s electronic charts and publications are not up-to-date. Update charts and publications to satisfaction of MI. 33 CFR 164.30
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 August 2025
Resolution: Charts and pubs updated and loaded onto ECDIS
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 12 June 2025 Resolved
Piping systems must be installed so that under no condition will the operation of safety or relief valves be impaired. Port side fire main pressure relief valve is broken and a temporary cap/plug has been installed on the discharge piping. Repair valve to satisfaction of MI. 46 CFR 56.50-1(f)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 August 2025
Resolution: Cap removed and new valve installed
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 12 June 2025 Resolved
Each lifeboat, rigid liferaft, and rescue boat, unless otherwise stated in this paragraph, must carry the equipment listed in this paragraph and specified for it in table 1 to this section under the vessel's category of service. Both rescue boats have expired medical kits. All four lifeboats have expired sea sickness pills. Lifeboat #4 has expired water. Replace expired items to satisfaction of MI. 46 CFR 199.175(b)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 August 2025
Resolution: Equipment replaced
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 8 May 2024 Resolved
Provide OEM report attesting to repairs of #4 davit, and satisfactory condition of davits 1,2, and 3 to include satisfactory light load testing in the presence of a Coast Guard Marine Inspector. 705: Vessel is restricted to operating on a Lakes, Bays, and Sounds route in the waters of Penobscot Bay.
Action required: 705 - Other - as specified
Due 8 June 2024
Resolved 28 May 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 8 May 2024 Resolved
Reeplace damaged tricing strap on #4 lifeboat. 705: Vessel is restricted to operating on a Lakes, Bays, and Sounds route in the waters of Penobscot Bay.
Action required: 705 - Other - as specified
Due 8 June 2024
Resolved 28 May 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 8 May 2024 Resolved
Provide assessment (OEM) of damage to #4 lifeboat or davit and make report of the same available to attending Marine Inspector. 705: Vessel is restricted to operating on a Lakes, Bays, and Sounds route in the waters of Penobscot Bay.
Action required: 705 - Other - as specified
Due 8 June 2024
Resolved 28 May 2024
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 27 March 2024 Resolved
Provide an "as built" drawing fire detection system as installed to the USCG Marine Safety Center for review and approval. The submittal shall include a one-line diagram of the detector layout showing the arrangement of all strings and/or loops in the system.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 April 2024
Resolved 12 April 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 17 May 2023 Resolved
At least two of the steering-gear power units on the vessel are in operation when such units are capable of simultaneous operation. Port Steering system failure alarm received on steering stand. Observed that rudder will only turn to starboard on from the steering stand while on port (#2) steering system. Diagnose, correct and test remote port steering system to ensure full operational status. Any movement of vessel crew must monitor the steering system from the local control station in addition to bridge control.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 17 May 2023
Resolved 18 May 2023
Resolution: Received class report attesting to proper repairs. See attached.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 5 April 2023 Resolved
Demonstrate satisfactory launching of the ship's lifeboats from the stowed position. The action shall be performed only by personnel in an assigned billet for that purpose. The lifeboats must be lowered safely and in a timely manner would support a 30 minute launch requirement from an abandon ship signal. Installed equipment must operate without failure and in a manner acceptable to the OCMI.
Action required: 17 - Rectify deficiencies prior to departure
Due 5 May 2023
Resolved 10 May 2023
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 5 April 2023 Resolved
Install adequate drain piping where temporary hose is currently installed for deck drains at the forward end of the aft superstructure, port and starboard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2023
Resolved 10 May 2023
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 5 April 2023 Resolved
Prove operation of telephone in 02 Aft Lounge.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2023
Resolved 10 May 2023
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 5 April 2023 Resolved
Repair exit light in 02 Aft Lounge.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2023
Resolved 10 May 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 April 2023 Resolved
Address exposed wiring in Fan room 02-68-0.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2023
Resolved 10 May 2023
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 5 April 2023 Resolved
Relocate plywood in focsle so that it does not obstruct access to forepeak access or electrical panels.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2023
Resolved 10 May 2023
12 - Dangerous Goods › N/A - No Subsystem › Fire protection cargo deck area
Issued 5 April 2023 Resolved
Relocate sterno fuel in 1-60-0 to liquid flammable stores locker.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2023
Resolved 10 May 2023
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 5 April 2023 Resolved
Install firestop as needed in cableway, overhead in passage 1-75-0 IWO galley door.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2023
Resolved 10 May 2023
09 - Working and Living Conditions › 092 - Working Conditions › Holds and tanks safety
Issued 5 April 2023 Resolved
Secure CO2 cylinders in rack from transverse movement (laundry room).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2023
Resolved 10 May 2023
09 - Working and Living Conditions › 091 - Living Conditions › Furnishings
Issued 5 April 2023 Resolved
Repair broken sink in stateroom 02-118-2.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2023
Resolved 10 May 2023
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 5 April 2023 Resolved
Prove operation of damper 1-134-12 in fan room 2-124-2.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2023
Resolved 10 May 2023
08 - Alarms › N/A - No Subsystem › General alarm
Issued 5 April 2023 Resolved
Provide General Alarm placard in deck lab 2-160-2.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2023
Resolved 10 May 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 April 2023 Resolved
Investigate/address unlabeled tagout in feeder panel 6L159 in passage outside stateroom 01-137-2.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 April 2023
Resolved 10 May 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 April 2023 Resolved
Prove operation of followup control panel indicators on steering stand panel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2023
Resolved 10 May 2023
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 5 April 2023 Resolved
Loosen/free up port side stanchion on 04 level liferaft.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2023
Resolved 10 May 2023
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 5 April 2023 Resolved
Provide Firestop in cable pass through, deck lab 1-160-2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2023
Resolved 10 May 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 March 2023 Resolved
Label circuit breaker assignments on panel directory in chart room feeder panel 1L150.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2023
Resolved 10 May 2023
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 April 2022 Resolved
Marine Employers shall establish programs for random chemical testing for crew members listed in 46 CFR 16.230, notably those that perform duties and functions of patrolman or watchmen to meet the Coast Guard's 50% requirement. 46 CFR 16.107 allows for requesting a waiver that may lower this percentage for cadets. Initiate a plan for compliance within 30 days and show progress within 90 days to meet this requirement 12 months from the date of this inspection/audit.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 April 2025
Resolved 19 May 2022
Resolution: Marine Employer is on track to meet the requirements for 2022-2023.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 April 2022 Resolved
Marine Employers must submit drug program data required by 49 CFR 40.26 and appendix H of 49 CFR part 40. The Management Information System (MIS) form can be downloaded from: http://www.uscg.mil/hq/g-m/moa/dapip.htm This form must be submitted by March 15 every year following the date of this inspection.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 April 2023
Resolved 16 August 2022
Resolution: Marine Employer has provided sufficient information to prove they will meet DAPI requirements for this period.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 22 November 2021 Resolved
The installation of all systems of a marine engineering nature, together with the details of design, construction, and installation, shall be in accordance with the requirements of subchapter F (Marine Engineering) of this chapter. Drain piping from main deck scuttle drain found to have two small holes, resulting in an intake of water in unassigned space 2-104-1. One hole is located 12 inches above overboard penetration and the other located just below the same penetration at the weld.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 December 2021
Resolved 8 February 2022
Resolution: Attended vessel. Witnessed and tested satisfactory repair of drain pipe.
10 - Safety of Navigation › N/A - No Subsystem › Speed and distance indicator
Issued 19 October 2021 Resolved
Make repairs to transducer and prove operation of the doppler speed log unit. Deficiency to be corrected not later than completion of the next credit Drydock.
Action required: 705 - Other - as specified
Due 28 February 2023
Resolved 3 April 2023
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 25 March 2021 Resolved
Swing Compass/Update deviation card.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 April 2021
Resolved 3 May 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 March 2021 Resolved
Provide proper lock/tagout for CB10, fan room 02-68-0. Also, panel cover cannot be closed with that lock in place.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2021
Resolved 8 April 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 25 March 2021 Resolved
Repair delaminated seat on lifeboat #2.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 April 2021
Resolved 14 April 2021
08 - Alarms › N/A - No Subsystem › Closing water-tight doors alarm
Issued 25 March 2021 Resolved
Prove operation of of fwd proximity switch on 2-86-0 (WTD alarm).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2021
Resolved 8 April 2021
02 - Structural Conditions › N/A - No Subsystem › Openings to cargo area, doors, ... scuttles
Issued 25 March 2021 Resolved
Install missing bolts on manhole cover in storeroom 3-75-2 (Macerator Access).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2021
Resolved 8 April 2021
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 25 March 2021 Resolved
Provide clear access to exits from Coasl Room (locks, vidmar cabinet).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2021
Resolved 8 April 2021
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 27 August 2019 Resolved
The installed Fire Detection system is comprised of components from three different systems and is not installed IAW Type Approval Documents. Prove that the system is approved and complies with Type Approval Documentation. Any proposals for a new system or modfications to the existing system are to be reviewed and approved by Marine Safety Center. Deficiency is to be corrected no later than completion of the next credit drydock.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 May 2022
Resolved 26 March 2024
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 7 June 2019 Resolved
the vessel's port steering system has experienced an episode of port rudder angle being applied without any helm command given.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2019
Resolved 20 June 2019
Resolution: ABS witnessed sat steering test after renewal of follow up amplifier board.
Engineering › Diesel Engine (propulsion-direct drive) › Gear/Clutch Starter (air motor)
Issued 25 July 2017 Resolved
Maine Engine Clutch is not engaging when prompted. Vessel system is being operated with a by-pass to the clutch and manual governer actuation.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 July 2017
Resolved 28 July 2017
Resolution: Vessel rep. repaired the air system feeding the M/E clutch. Clutch and air system satisfactory tested.
Engineering › Steam Boiler (auxiliary/waste heat) › Valve, Relief
Issued 8 May 2017 Resolved
Test Exhaust Gas Boiler operation and safeties once the vsl goes u/w.
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 12 May 2017
Resolution: Boiler tested by the C/E, all SAT.
Operations/Management › Drug and Alcohol Testing › Testing, Serious Marine Incident
Issued 29 July 2016 Resolved
Conduct drug and alcohol program (DAPI) audit within 30 days of vessel return to homeport.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 October 2016
Resolved 29 August 2016
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder Head
Issued 31 May 2016 Resolved
See MISLE Act #5881474
Due 31 May 2016
Resolved 31 May 2016
Resolution: Rcvd ABS Class report. See attached documents.
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder Head
Issued 19 May 2016 Resolved
Make repairs to the broken head bolt on the #4 main engine cylinder.
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 26 July 2016
Electrical › Electrical Distribution System (service) › Wiring
Issued 4 April 2016 Resolved
Repair cable sheathing on sideshell floodlights where needed.
Action required: 705 - Other - as specified
Due 9 June 2016
Resolved 16 May 2016
Resolution: Chief Mate provided photos of repaired cable sheathing.