MAURY USCG vessel records Sign in
← All vessels

ARAYA

ARAYA is a 2001 freight ship. The Coast Guard has recorded 13 inspections since 2002, most recently in June 2017, along with 4 deficiencies and 1 operational control.

Records from 2002 to 2017. Most recent: inspection, 6 June 2017.

Built
2001
Last inspected
6 June 2017
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9224843 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
MALTA
—
Maury page id
psix-35488

Inspections, by type

…with no type recorded2
Years with a record 7 calendar years (2002–2017)
The 13 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it17697 - Regulatory (Subpart C or D), Gross Ton
35084 - Displacement, Metric Ton
28741 - Dead Weight, Metric Ton
10238 - Regulatory (Subpart C or D), Net Ton
17697 - Convention (Subpart B), Gross Ton
10238 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 13

6 June 2017 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6161198
12 February 2010 Ballast Water Examination · ISPS I Exam · PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3677699
9 February 2010 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3677417
1 October 2008 PII Safety Exam · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3335894
24 June 2007 MARPOL Annex I Examination · PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2972070
22 July 2005 ISPS II Exam · PII Safety Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2436787
22 December 2003 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1968516
8 October 2003 MARPOL Annex I Examination · Ballast Water Examination · Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1920765
8 October 2003 Type not recorded
No type recorded · Sector Astoria · USCG Northwest District (CGD-NW) · Activity 1924257
5 November 2002 Re-Inspection · Ballast Water Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1701390
22 July 2002 Administrative Inspection
Administrative · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 1648453
27 February 2002 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1489987
15 February 2002 Annual Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1485147

Deficiency record · 4

Documentation › Certificates/Documents
Issued 8 October 2003 Resolved
Include the " Waste O.T. for Incin" capacity 1176 Ltrs in Block 3.1 of the IOPP. MARPOL 73/78. LEGACY COMPONENT DESC: IOPP Certificate
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 23 December 2003
Resolution: IOPP amended by class.
Documentation › Logs/Records
Issued 8 October 2003 Resolved
Commence recording the Transfer to the "Waste O.T. for Incin" of sludge under the C-12-2 code found in Appendix III of Annex I of MARPOL 73/78. LEGACY COMPONENT DESC: Oil Record Book
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 23 December 2003
Resolution: Entries recorded in Oil Record Book.
Fire Fighting › Structural Fire Protection - General
Issued 8 October 2003 Resolved
Provide protection of oil system. SOLAS 74 and II-2/15.9. LEGACY COMPONENT DESC: Oil System
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 23 December 2003
Resolution: Outer high pressure fuel line jacket provided for the emergency generator.
Construction/Loadline › Structures
Issued 27 February 2002 Resolved
The watertight panel is missing from the STBD side of the rudder. Chief Engineer said he suspected that the bolts had vibrated loose. LEGACY COMPONENT DESC: Manhole
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 6 March 2002
Resolved 2 March 2002
Resolution: Recieved class report. Cleared deficiency.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.