MAURY USCG vessel records Sign in
← All vessels

BOA CANOPUS

BOA CANOPUS is a 1976 offshore supply vessel. The Coast Guard has recorded 7 inspections since 1993, most recently in March 2008, along with 16 deficiencies — 3 with no resolution recorded — and 1 operational control.

Records from 1993 to 2008. Most recent: inspection, 21 March 2008.

Built
1976
Last inspected
21 March 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7413622 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
355032
Flag
MEXICO
—
Maury page id
psix-355032

Inspections, by type

…with no type recorded3
…past their stated due date1
Years with a record 6 calendar years (1993–2008)
The 7 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it1093 - Convention (Subpart B), Net Ton
2133 - Dead Weight, Ton
3644 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 7

21 March 2008 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3170130
17 March 2006 In-Service Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2604432
11 February 2006 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2583631
3 August 2004 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2155144
19 November 2002 Annual Inspection · Ballast Water Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1715459
7 April 1997 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 400010
18 September 1993 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 113328

Deficiency record · 16

Documentation › Safety/Response Plans/Programs › SOPEP
Issued 21 March 2008 No resolution recorded
1705 - SOPEP missing or deficient - SOPEP contacts not updated since 2005. Marpol 73/78 Annex I/37 70 (c)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 21 March 2008 No resolution recorded
0199 - Other(Certificate) - The vessel has not prepared or submitted to the USCG a NTVRP. 33 USC 1321 (J)(5)
Due 21 March 2008 — due date passed with no resolution recorded
Construction/Loadline › Markings › Load Line Mark
Issued 11 February 2006 Resolved
01 1299 Load lines on ship rusted over and port markings blocked by tire fender, to be descaled and painted in contrasting colors IAW ILLC Annex I / reg 8 (17 b +c)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 March 2006
Resolution: Vessel has repainted the ILLC load line marks.
Pollution Prevention/Response › Prevention Equipment › Garbage Grinder/Comminuter
Issued 11 February 2006 Resolved
02 2055 Garbage Log does not indicate discharge of Reciepts of discharge o/b, however, log does not denote transfer IAW MARPOL V/ Reg 9/3/a (17 b+c)
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 March 2006
Resolution: Garbage log has been properly filled out all entries are correct
Navigation › Piloting/Steering › Maneuvering Information Fact Sheet
Issued 11 February 2006 No resolution recorded
03 2055 Ship lacks manuevering fact sheet on bridge to be provided IAW 33CFR 164 (17 b +c)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolution: manuevering fact sheet is now on the bridge
Electrical › Lighting (service) › Lighting Feeder
Issued 11 February 2006 Resolved
04 1499 All light fixtures in staterooms and open electrical junction box in way of main deck isolation valve to be enclosed and fit IAW SOLAS 60/ II E Reg 56 (e)(ii) (17 b )
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 March 2006
Resolution: All covers were in place.
Fire Fighting › Fire Main › Valves
Issued 11 February 2006 Resolved
05 0799 Fire main isolation valve for segregation of engineering and deck level fire main found frozen. Valve to be rebuilt or replaced to the working condition IAW SOLAS 60/II/ E Reg 56 (e)(ii) (17 b + c)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 March 2006
Resolution: Isolation valve was renewed and demonstrated operational.
Pollution Prevention/Response › Prevention Equipment › Garbage Grinder/Comminuter
Issued 11 February 2006 Resolved
06 (2055) Garbage plan is not ship specific. Plan is company directive with no approval for vessel plan o/b. Company to provide ship specific plan IAW MARPOL V/ Reg 9 (2) (17 b and c)
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 March 2006
Resolution: Garbage plan is now ship specific
Construction/Loadline › Hull › Bottom Plating
Issued 11 February 2006 Resolved
07 1499 Ship to address and class to survey scaled and wasted longitudinal and tranverse plate in eng rm between fresh water tk in stbd fwd ERspace tank top in way of SSG#4 +tk plating in aft eng tk top adjacent to f.o.tk port aft corner.Class to include repairs in class report to be provided IAW SOLAS60/II/Reg36 (17 b+c)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 March 2006
Resolution: Class has reported that all these issue have been corrected in dry dock. the repairs have been approved and the vessel will remain classed
Fire Fighting › Fire Main › Material
Issued 11 February 2006 Resolved
08 0799 Fire main sections on main deckin way of fire sta #17 and 18 stbd/port aft of house severly scaled to be assessed by class for scantling sufficiency and crop and renew as needed with class report issued IAW SOLAS 60/II/56(e) + ch I/10 (17 b+c)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 March 2006
Resolution: vessel fire main has been renewed
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 11 February 2006 Resolved
09 0695 SOLAS training manual to be translated into Spanish or language of crew prior to return to U.S. port. IAW SOLAS 74allship/ III/ Reg35 (70 c)
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 March 2006
Resolution: SOLAS TRAINING MANUAL IS NOW IN WORKING LANGUAGE
Navigation
Issued 7 April 1997 Resolved
PROVE THE PROPER OPERATION OF THE VESSEL'S RADAR._x001C_ SOLAS 74 (AMENDED) V/12(G)
Condition: Unknown
Due 8 April 1997
Resolved 9 April 1997
Navigation
Issued 7 April 1997 Resolved
PROVE THE PROPER OPERATION OF THE VESSELS GYROCOMPASS._x001C_ SOLAS 74 (AMENDED) V/17 (d),(e).
Condition: Unknown
Due 8 April 1997
Resolved 9 April 1997
Navigation
Issued 7 April 1997 Resolved
PROVE THE PROPER OPERATION OF THE VESSELS STEERING GEAR AND CONTROLS IN ALLMODES._x001C_ SOLAS 74(AMENDED)V/19-2
Condition: Unknown
Due 8 April 1997
Resolved 9 April 1997
Fire Fighting
Issued 7 April 1997 Resolved
RENEW AS ORIGINAL THE DETERIORATED FIREMAIN PIPING LOCATED ON THE STARBOARDOF THE ENGINE ROOM, IN THE OVERHEAD._x001C_ SOLAS 74(AMENDED) II-2/21
Condition: Unknown
Due 8 April 1997
Resolved 9 April 1997
Engineering
Issued 7 April 1997 Resolved
PROVE THE PROPER OPERATION OF THE VESSELS OILY WATER SEPARATOR._x001C_ MARPOL 73/78 ANNEX I/16 (7) & 33 CFR 155.380(b)
Condition: Unknown
Due 8 April 1997
Resolved 9 April 1997

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.