SWEET LIBERTY

SWEET LIBERTY is a 1990 passenger vessel (inspected). The Coast Guard has recorded 78 inspections since 1990, most recently in February 2026, along with 123 deficiencies and 2 casualty investigations between 2005 and 2018.

Records from 1990 to 2026. Most recent: inspection, 9 February 2026.

Built
1990
Last inspected
9 February 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDJ2804
355047
Flag
UNITED STATES
367489140
Maury page id
psix-355047

Inspections, by type

…with no type recorded10
Years with a record 31 calendar years (1990–2026)
The 78 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)53.0 ft × 29.0 ft × 6.7 ft
Registered tonnagegross 17 / net 17
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGOLD COAST YACHTS, INC. · ST CROIX, VI, UNITED STATES · built 1990
Hull materialFRP (Fiberglass)
PropulsionGasoline Outboard
Hull shapeSail (Faired Keel)
Hull configurationTwin Hull
Hailing portNAPLES, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 10 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it17 - Simplified, Gross Ton
17 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDJ2804MMSI 367489140 · active · voluntarily equipped · granted 15 November 2016, expires 15 November 2026
WDF7883MMSI 367489140 · cancelled · compulsorily equipped · granted 7 May 2011, cancelled 10 November 2016
WAQ7964MMSI not assigned · expired · compulsorily equipped · granted 28 November 1995, cancelled 1 April 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 78

9 February 2026 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8301617
8 September 2025 Internal Structural Exam · Hull Examination · Drydock Exam · Administrative Inspection · Examination of Repairs · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8220528
6 February 2025 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8067692
21 December 2024 Damage Survey
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8049946
27 February 2024 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7870517
8 February 2024 Damage Survey
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7862928
22 September 2023 Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7750664
28 June 2023 In-Service Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7724618
10 November 2022 Type not recorded
No type recorded · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7592736
4 November 2022 COI Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7589456
18 October 2022 Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7579926
19 May 2022 Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7448298
25 October 2021 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7321593
19 February 2021 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7160918
18 November 2020 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7095929
14 September 2020 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7024003
13 April 2020 Administrative Inspection · In-Service Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6937519
6 November 2019 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6847033
8 October 2019 Administrative Inspection · Examination of Repairs · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6830782
18 April 2019 Damage Survey · Deficiency Check · Administrative Inspection · Examination of Repairs · In-Service Inspection · Construction Oversight
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6681015
7 November 2018 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6575653
30 October 2018 Type not recorded
No type recorded · Station Fort Myers Beach · USCG Southeast District (CGD-SE) · Activity 6571913
20 September 2018 Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6489607
6 March 2018 Type not recorded
No type recorded · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6366850
23 February 2018 In-Service Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6360350
18 September 2017 COI Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6269192
10 August 2017 Internal Structural Exam · Administrative Inspection · Drydock Exam · Examination of Repairs
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6234303
6 June 2017 Administrative Inspection · In-Service Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6167606
17 October 2016 Deficiency Check · Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6006506
14 January 2016 Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5808000
4 September 2015 Drydock Exam · Deficiency Check · Internal Structural Exam · Hull Examination · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5214584
17 August 2015 Damage Survey
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5219296
15 August 2015 Type not recorded
No type recorded · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5219288
1 December 2011 DAPI Audit · Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4198758
8 September 2011 Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4127805
12 August 2011 Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4113573
1 December 2010 Annual Inspection · DAPI Audit · Deficiency Check · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3893310
23 October 2008 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3348363
27 November 2007 Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3087455
23 October 2007 Administrative Inspection · COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3080197
4 January 2007 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2846052
7 February 2006 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2580514
1 November 2005 Hull Examination · Damage Survey
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2526026
24 October 2005 Type not recorded
No type recorded · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2564218
18 August 2005 Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2466126
25 January 2005 Plan Review "T" Boat
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2280348
12 January 2005 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2280787
3 September 2003 Deficiency Check · Hull Examination · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1894994
19 November 2002 Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1708140
7 November 2002 COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1701630
10 December 2001 Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 773059
16 October 2001 Re-Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1436638
31 January 2001 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1058769
16 December 1999 Hull Examination · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1403027
9 November 1999 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1403026
23 November 1998 Re-Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1466018
28 April 1998 Plan Review "T" Boat
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1430540
23 February 1998 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 779585
18 December 1997 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1426013
10 November 1997 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1466487
4 September 1997 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 96148
6 December 1996 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1453299
16 July 1996 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1398493
18 December 1995 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 884465
18 April 1995 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1186018
30 December 1994 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 855638
8 December 1994 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 850630
9 December 1993 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 849308
4 May 1993 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1423772
21 April 1993 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 829715
10 December 1992 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1136947
23 June 1992 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 949804
2 June 1992 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1259103
11 December 1991 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1002874
11 December 1991 Re-Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1263851
26 December 1990 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 904395
21 December 1990 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 942845
9 December 1990 COI Inspection · Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1242364

Deficiency record · 123

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 February 2025 Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Port and Starboard automatic bilge pump visual indicator at the operating station in non-operable. Make permanent repairs and prove proper operation to the attending CG Marine Inspector. 46CFR182.530(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 February 2025
Resolution: A visual indicator is now provided and properly tested for sufficient operation at the operating station to indicate when any automatic bilge pump is operating for both port and starboard hulls.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 February 2025 Resolved
The Preventative Maintenance Plan (PMP) should include an inventory of all rigging components, including the age of component, size, type of material, and a replacement schedule for all rig components based on inspection results, service history, and manufacturer or designer recommendations. 46CFR177.202
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 March 2025
Resolution: The Preventative Maintenance Plan (PMP) now includes an inventory of all rigging components, including the age of component, size, type of material, and a replacement schedule for all rig components based on inspection results, service history, etc.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 February 2025 Resolved
Sail rig aloft inspections are not completed as documented on the vessels Preventative Maintenance Plan PMP as follows: Close inspections aloft conducted by Captain or experienced Crew Member. Checking for missing cotter pins, parted strands on shrouds or stays, splits in swage tails and furling system and halyard attachments. Complete and document maintenance IAW PMP. 46CFR177.330
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 March 2025
Resolution: Sail rig aloft inspections are now completed as documented on the vessels Preventative Maintenance Plan PMP as follows: Close inspections aloft conducted by Captain or experienced Crew Member.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 6 February 2025 Resolved
Except when in the judgment of the cognizant OCMI the operation of a vessel does not present one of the hazards listed, the emergency instruction placard should contain at least the applicable portions of the “Emergency Instructions” listed in § 185.512. The emergency instructions must be designed to address the particular equipment, arrangement, and operation of each individual vessel. The vessel's emergency instructions do not address sail rig equipment and steps that must be taken during an emergency and/or hazardous situation while conducting sailing operations. 46CFR185.510
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 February 2025
Resolution: The vessel's emergency instructions now address sail rig equipment and steps that must be taken during an emergency and/or hazardous situation while conducting sailing operations.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 4 November 2022 Resolved
An inspection for renewal of a Certificate of Inspection is conducted to determine if the vessel is in satisfactory condition, fit for the service intended, and complies with all applicable regulations. It normally includes inspection and testing of the structure, machinery, equipment, and on a sailing vessel, rigging and sails. The owner or operator must conduct all tests as required by the OCMI, and make the vessel available for all specific inspections and drills required by subpart H of this part. In addition, the OCMI may require the vessel to get underway. (b) You must submit your written application for renewal of a Certificate of Inspection to the OCMI at least 30 days prior to the expiration date of the Certificate of Inspection, as required in § 176.105 of this part. COI expired on 18OCT2022. Owner was instructed on 21OCT2022 to not carry passengers until a satisfactory inspection was completed. Owner has been operating with passengers as of this date. COI renewal inspection is now scheduled for 09NOV2022. 46 CFR 176.404
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 November 2022
Resolved 9 November 2022
Resolution: Completed renewal of COI.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 22 June 2022 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. The owner or managing operator shall submit details of any proposed alterations to the cognizant [name withheld] are not required to be submitted for repairs or replacements in kind. The OCMI may require an inspection and testing whenever a repair or alteration is undertaken. The SWEET LIBERTY is outfitted with a three point rigging system. The shrouds are split with a rig tensioner to facilitate removing the flopping or slap in the leeward shroud when tacking. The marine inspector identified a stress point and tension on the port and starboard shroud clevis pins at the attachment to the chain plate. The owner removed the clevis pin for visual inspection and fractures were identified on the end of the clevis pin in the vicinity of the cotter pin attachment. Additional grooving and pitting was observed on the body of the clevis pin. Replace clevis pins and contact USCG for re-inspection once replaced. 46 CFR 176.700
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2022
Resolved 9 November 2022
Resolution: New clevis pins in place.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 June 2022 Resolved
In accordance with 46 CFR 185.602, the subject vessel is required to have draft marks or loading marks. This was indicated on the June 25, 2014 MSC revised stability letter H1-1402245. Per the approved stability letter: A minimum freeboard of at least 4 feet 2 inches to the main deck at amidships must be maintained. This corresponds to a maximum midship draft of 2 feet 3 inches, measured to the bottom of the keel, and 10 inches measured to the design waterline. Amidships is located 26 feet 6 inches aft of the bow. Provide loading marks in accordance with the dimensions listed on the stability letter. 46 CFR 185.602
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 July 2022
Resolved 9 November 2022
Resolution: Loading marks affixed to both port and starboard hulls IAW stability letter.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › UMS - Ship
Issued 25 October 2021 Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. Vessel does not have a Preventative Maintenance Plan (PMP)and could not provide documentation of a recent rigging inspection. No routine or prescriptive maintenance regarding sail rigging could be provided. Coast Guard inspectors have provided guidance and templates of PMPs to owner over the past year for implementation. Prior to carrying passengers, have a 3rd party rigging inspection to include aloft inspection and submit a draft PMP to Coast Guard DDO Fort Myers for review
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 November 2021
Resolved 26 October 2021
Resolution: Received rigging inspection report and template PMP IAW NVIC. Will follow up in 03 months to verify PMP is being utilized.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 25 October 2021 Resolved
Deck rails must be designed to withstand 200 pounds applied at any point. Port quarter hand rail is loose as evident by 02 missing deck bolts. Repair to satisfaction of a Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2021
Resolved 24 November 2021
Resolution: Received photos of repaired stanchion support.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 October 2021 Resolved
A vessel must carry one floating waterlight, waterlight for ring life buoy is inoperable. Restricted to daylight operations only until rectified.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2021
Resolved 26 October 2021
Resolution: Received picture and video of working ring buoy light.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 25 October 2021 Resolved
The marine employer must have a sufficient number of alcohol test devices. No alcohol testing kits are onboard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2021
Resolved 24 November 2021
Resolution: Received photo of newly acquired swabs.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 October 2021 Resolved
All cable and wires must be installed with metal supports, spaced not more than 24 inches apart. Electrical wire for running light on starboard void is laying along bilge, properly secure.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2021
Resolved 24 November 2021
Resolution: Received photo of properly installed electrical wire.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 October 2021 Resolved
A suitable metal marine type strainer, must be fitted in the fuel supply line. Fuel filter installed has plastic drip tray.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2021
Resolved 24 November 2021
Resolution: Received photo of new fuel filters.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 25 October 2021 Resolved
A vessel must carry adequate and up to date, Coast Pilot [name withheld] List and Tide Tables. Provide updated listed publications for navigation area.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2021
Resolved 26 October 2021
Resolution: Received picture of new publications onboard.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 18 November 2020 Resolved
Hydrostatic release unit for the EPIRB expired October 2020. Replace with new unit.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 December 2020
Resolved 9 November 2022
Resolution: Confirmed clear during COI renewal.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 6 November 2019 Resolved
Provide proof of obtaining Marine Operator [name withheld] for capatain's onboard and obtain new Safety Certificate from FCC
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 December 2019
Resolved 5 December 2019
Resolution: Owner submitted photos as proof.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 6 November 2019 Resolved
Provide Proof of vessel logs being recorded and maintained for drills and EPIRB.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 December 2019
Resolved 5 December 2019
Resolution: Owner submitted photos as proof.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 6 November 2019 Resolved
Provide Coast Pilot and update charts
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 November 2019
Resolved 19 November 2019
Resolution: Owner submitted photos as proof.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 November 2019 Resolved
Provide posted Emergency Instructions for fire, rough weather and man overboard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 November 2019
Resolved 19 November 2019
Resolution: Owner submitted photos as proof.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 8 October 2019 Resolved
Hull impact to port catamaran from allision to dock corner.
Action required: 10 - Deficiency Rectified
Resolved 8 October 2019
Resolution: Repair completed, see narrative.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 18 April 2019 Resolved
A-frame is cracked and requires replacement.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 July 2019
Resolution: New A-frame built and installed.
Construction/Loadline › Hull › Bottom Plating
Issued 10 August 2017 Resolved
Renew fiberglass on both hulls where reinforced for beaching (46CFR176.600)
Action required: 705 - Other - as specified
Resolved 14 August 2017
Resolution: Rewnewed fiberglass on both hulls.
Construction/Loadline › Hull › Bracket
Issued 10 August 2017 Resolved
Rewnew end cap for motor mount pin (46CFR176.600)
Action required: 705 - Other - as specified
Resolved 14 August 2017
Resolution: Rewnewed end cap.
Sail Rigging › Catamaran › Crossbeam
Issued 10 August 2017 Resolved
Replace two beams IWO bow area where netting is tied. (46CFR176.600)
Action required: 705 - Other - as specified
Resolved 14 August 2017
Resolution: Replaced two rotted beams with new ones.
Communications › Radio Communications › EPIRB
Issued 17 October 2016 Resolved
Hydrostatic release is expired.
Action required: 705 - Other - as specified
Resolved 18 October 2016
Resolution: New EPIRB purchased.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 17 October 2016 Resolved
Start and maintain logs, lifesaving, EPIRB.
Action required: 705 - Other - as specified
Resolved 19 October 2016
Resolution: Logbook begun.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 17 October 2016 Resolved
Provide current EAP and copy of MIS report.
Action required: 705 - Other - as specified
Resolved 19 October 2016
Resolution: Verified current EAP and MIS report.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 17 October 2016 Resolved
Provide current tide tables.
Action required: 705 - Other - as specified
Resolved 19 October 2016
Resolution: Verified current tide tables on board.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 17 October 2016 Resolved
Provide new first aid kit.
Action required: 705 - Other - as specified
Resolved 19 October 2016
Resolution: New first aid kit purchased and placed on board.
Lifesaving › Hand Flares › Storage
Issued 17 October 2016 Resolved
Place flares in proper, bright, watertight container.
Action required: 705 - Other - as specified
Resolved 19 October 2016
Resolution: Approved container purchased.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 17 October 2016 Resolved
Provide copy of latest rigging report, to include last mast unstepping.
Action required: 705 - Other - as specified
Resolved 18 October 2016
Resolution: Copy of report provided. Last unstepping completed in SEP11.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 17 October 2016 Resolved
Provide evidence of preventative maintenance plan to include, detailed description of the rig and associated gear; drawings/pictures of rig/key components; manufacturer, purchase and installation dates of all components; types of furlers/tensioning systems; description of sea trials.
Action required: 705 - Other - as specified
Resolved 7 November 2018
Resolution: Records maintained by owner/operator.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 28 September 2015 Resolved
Provide 50 additional asprin and ammonia inhalents for first aid kit. IAW 46 CFR 160.041
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 October 2015
Resolved 13 October 2015
Resolution: Aspirin and Ammonia provided onboard.
Navigation › Piloting/Steering › Marine Charts
Issued 28 September 2015 Resolved
Provide current chart on board IAW 46 CFR 184.420.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 October 2015
Resolved 2 October 2015
Resolution: Owner supplied new chart onboard.
Sail Rigging › Deck Hardware › Travellers and Blocks
Issued 11 September 2015 Resolved
Replace both port and stbd deck mounted rigging boards for lifting the dagger boards.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 25 September 2015
Resolution: Both boards replaced with new.
Construction/Loadline › Hull › Hull Plating
Issued 4 September 2015 Resolved
Make permanent repairs to spots identified on port hull.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 25 September 2015
Resolution: Hull areas repaired to original.
Construction/Loadline › Hull › Strut/Cross Tie
Issued 4 September 2015 Resolved
Make repairs to exposed hull areas where rudder cross bar passes through. Prior to credit dry-dock
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 25 September 2015
Resolution: Areas repaired to original.
Engineering › Steering Gear System › Rudder
Issued 4 September 2015 Resolved
Service entire steering system. Most connection points are worn and loose, Prior to credit dry-dock.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 11 September 2015
Resolution: Steering system serviced.
Engineering › Steering Gear System › Cable
Issued 4 September 2015 Resolved
Repair or replace top steering system cable pully bushing, Prior to credit dry-dock.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 11 September 2015
Resolution: Pulley replaced with new.
Sail Rigging › Deck Hardware › Travellers and Blocks
Issued 4 September 2015 Resolved
Replace stbd aft deck mounted rigging block, Prior to credit dry-dock.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 11 September 2015
Resolution: Deck wood block replaced with new.
Construction/Loadline › Hull › Bottom Plating
Issued 4 September 2015 Resolved
Re-build back up bow areas used for beaching operations, IAW CID Note #04, Prior to credit dry-dock.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 25 September 2015
Resolution: Both bow areas built up with 3 layers of fiberglass, with a color scheme of Black, Yellow and Red.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 4 September 2015 Resolved
Tighten all entrance ladder attachment to hull screws, Prior to credit dry-dock.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 11 September 2015
Resolution: All entrance ladder attachment screws tightend.
Stability › Watertight Integrity › Deadlight Cover
Issued 4 September 2015 Resolved
Replace aft portlight, portside window seal and test for water-tightness, Prior to credit dry-dock.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 11 September 2015
Resolution: Window seal replaced with new.
Sail Rigging › Spars › Antennas, Light, Wind Indicators
Issued 4 September 2015 Resolved
Make repairs to mast identified during inspection, and provide rigging report to the CG, Prior to credit dry-dock.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 25 September 2015
Resolution: Mast areas repaired to original.
Construction/Loadline › Hull › Keel Plate
Issued 4 September 2015 Resolved
Romove both dagger boards to make areas available for inspection, Prior to credit dry-dock.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 11 September 2015
Resolution: Both dagger boards removed.
Documentation › Markings/Placards › Warning Signs
Issued 4 September 2015 Resolved
Label escape hatches as required by 46 CFR 185.606.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 October 2015
Resolved 13 October 2015
Resolution: All escape hatches labeled.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 4 September 2015 Resolved
Provide 01 type B-I portable fire extinguisher at the operating station, IAW 46 CFR 181.500.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 October 2015
Resolved 2 October 2015
Resolution: Owner installed B-1 at operating station.
Construction/Loadline › Hull › Hull Plating
Issued 17 August 2015 Resolved
Vessel was struck by lightning while u/w w/ passengers. Vessel's bonding system is not 100% intact. Vessel must haul out and conduct hull inspection including rigging inspection and report and unstep the mast for inspeciton. 46 CFR 176.610
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 September 2015
Resolution: Vessel completed a successful drydock inspection.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 1 December 2011 Resolved
Provide a copy of MIS report for drug testing IAW 46CFR16.
Action required: 705 - Other - as specified
Due 8 December 2011
Resolved 1 December 2011
Operations/Management › Drug and Alcohol Testing › Testing, Serious Marine Incident
Issued 1 December 2011 Resolved
Provide means of alcohol testing after a serious marine incident IAW 46CFR16.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 December 2011
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 1 December 2011 Resolved
Install a 60 foot, bouyant, 5/16 diameter lifeline to ring buoy IAW 46CFR180.70(c).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 December 2011
Lifesaving › Lifebuoys › Serviceable
Issued 1 December 2010 Resolved
Install retroflective tape on ring lifebouy IAW 46CFR185.604(i)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 December 2010
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 1 December 2010 Resolved
Provide an approved first aid kit IAW 46CFR184.710
Action required: 705 - Other - as specified
Due 14 December 2010
Resolved 3 December 2010
Engineering › Bilge Water Management System › Not Installed
Issued 1 December 2010 Resolved
Provide a means to dewater each watertight compartment IAW 46CFR182.25-5(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 December 2010
Communications › Alarms/Indicators › Bilge Alarm
Issued 23 October 2008 Resolved
Repair bilge high alarm
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 October 2008
Communications › Public Address System › Loudspeaker
Issued 23 October 2008 Resolved
Repair PA system
Due 29 October 2008
Resolved 23 October 2008
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 23 October 2008 Resolved
Replace items in first aid kit.
Due 29 October 2008
Resolved 23 October 2008
Communications › Alarms/Indicators › Fire Alarm
Issued 23 October 2008 Resolved
Install smoke detection system sensors
Due 29 October 2008
Resolved 23 October 2008
Engineering › Fuel Oil Service System › Valve
Issued 23 October 2007 Resolved
Re-install fuel shutoff valves.
Due 24 October 2007
Resolved 23 October 2007
Lifesaving › Hand Flares › Expired
Issued 23 October 2007 Resolved
Replace expired flares.
Due 24 October 2007
Resolved 23 October 2007
Documentation › Logs/Records › Drug Test Records
Issued 4 January 2007 Resolved
Provide drug testing documentation copy of latest MIS report .
Due 5 January 2007
Resolved 5 January 2007
Communications › Radio Communications › EPIRB
Issued 4 January 2007 Resolved
Provide registration for EPIRA along with servicing report for hydro test .
Due 11 January 2007
Resolved 10 January 2007
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 4 January 2007 Resolved
Conduct underway emergency drill and test the vessel's propulsion and sails.
Due 11 January 2007
Resolved 10 January 2007
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 4 January 2007 Resolved
Replace expired items in first aid kit.
Due 11 January 2007
Resolved 10 January 2007
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 4 January 2007 Resolved
Service two fire extinguishers.
Due 11 January 2007
Resolved 10 January 2007
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 4 January 2007 Resolved
Mark high level bilge alarm indicator and breaker.
Due 5 January 2007
Resolved 5 January 2007
Engineering › Freshwater Generation System › Piping
Issued 4 January 2007 Resolved
Replace portside fresh water fuel line.
Due 11 January 2007
Resolved 10 January 2007
Electrical › Lighting (service) › Lighting Fixture
Issued 4 January 2007 Resolved
Install missing light cover port side lower deck.
Due 11 January 2007
Resolved 10 January 2007
Stability › Watertight Integrity › General
Issued 4 January 2007 Resolved
Replace damaged O ring forward starboard side lower deck.
Due 5 January 2007
Resolved 5 January 2007
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 4 January 2007 Resolved
Remove paint from the vessel.
Due 5 January 2007
Resolved 5 January 2007
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 7 February 2006 Resolved
Provide evidence of an Employee assistance program and the latest MIS report.
Action required: 705 - Other - as specified
Due 14 February 2006
Resolved 13 February 2006
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 7 February 2006 Resolved
Refresh all expired items in the first aid kit.
Action required: 705 - Other - as specified
Due 14 February 2006
Resolved 13 February 2006
Construction/Loadline › Hull › Bottom Plating
Issued 1 November 2005 Resolved
PROVIDE A DETAILED REPAIR PROPOSAL PRIOR TO INSTALLING NEW WOOD AND FRP TO HULLS WHERE SEVERELY DAMAGED BY HURRICANE WILMA; INCLUDE BUILDER RECCOMENDATIONS, MATERIALS TO BE USED, FRP LAY-UP SCHEDULE ETC.
Due 22 December 2005
Resolved 8 November 2005
Construction/Loadline › Hull › Hull Plating
Issued 1 November 2005 Resolved
PROVIDE A STANDARD REPAIR PROCEDURE FOR THE MINOR HULL DAMAGE THAT DIDN'T PENETRATE THE WOOD BOTTOM.
Due 22 December 2005
Resolved 8 November 2005
Construction/Loadline › Structures › Superstructure
Issued 18 August 2005 Resolved
Provide rigging report to MSD Fort Myers.
Action required: 705 - Other - as specified
Due 25 August 2005
Resolved 25 August 2005
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 12 January 2005 Resolved
PROVIDE A COPY OF CURRENT DRUG TESTING CONSORTIUM CONTRACT.
Due 12 February 2005
Resolved 19 January 2005
Lifesaving › Hand Flares › Quantity
Issued 12 January 2005 Resolved
PROVIDE AN ADDITIONAL 6 HAND HELD FLARES ONBOARD VESSEL.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 February 2005
Resolved 12 January 2005
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 12 January 2005 Resolved
APPLY RETRO TAPE TO RING BOUY.
Due 12 February 2005
Resolved 19 January 2005
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 12 January 2005 Resolved
RENEW EYEWASH AND AMMONIA INHALENTS IN FIRST AID KIT.
Due 12 February 2005
Resolved 19 January 2005
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 12 January 2005 Resolved
PROVIDE A FUEL TANK SHUT-OFF VALVE.
Due 12 February 2005
Resolved 19 January 2005
Construction/Loadline › Hull
Issued 3 September 2003 Resolved
Properly repair small gouges in bottom gelcoat just forward of the centerboard in way of port and starboard hulls. LEGACY COMPONENT DESC: Keel
Due 2 October 2003
Resolved 3 September 2003
Resolution: Repairs in hand during examination. All noted gouges in gelcoat were sanded smooth and resin coated.
Operations/Management › Drug and Alcohol Testing
Issued 3 September 2003 Resolved
Provide copy of Drug and Alcohol testing program contract and MIS report. LEGACY COMPONENT DESC: MIS Submission
Due 3 October 2003
Resolved 25 September 2003
Deck/Cargo
Issued 3 September 2003 Resolved
Provide a copy of the rigging inspection report.
Due 3 October 2003
Resolved 25 September 2003
Lifesaving › Lifebuoys
Issued 3 September 2003 Resolved
Provide a non-alkaline battery w/screw top post terminals for ring bouy light. LEGACY COMPONENT DESC: Self-igniting Lights
Due 3 October 2003
Resolved 25 September 2003
Communications › Alarms/Indicators
Issued 3 September 2003 Resolved
Repair stbd bilge alarm. LEGACY COMPONENT DESC: Bilge Alarm
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 October 2003
Resolved 25 September 2003
Operations/Management › Drills/Instruction
Issued 3 September 2003 Resolved
Conduct underway man overboard and fire drills with a Coast Guard Marine Inspector. LEGACY COMPONENT DESC: Fire
Due 3 October 2003
Resolved 25 September 2003
Construction/Loadline › Structures
Issued 7 November 2002 Resolved
REPAIR FRACTURED LONGITUDINAL DECK STRINGER FORWARD OF CABIN AT PORT HATCH FRAME.
Due 22 November 2002
Resolved 19 November 2002
Electrical › Electrical Distribution System (service)
Issued 7 November 2002 Resolved
PROPERLY SPLICE WIRING IN PORT HULL USING BUTT TYPE CONNECTORS. LEGACY COMPONENT DESC: Wiring
Due 22 November 2002
Resolved 19 November 2002
Engineering › Steering Gear System
Issued 7 November 2002 Resolved
SECURE PORT TILLER CONNECTION WITH COTTER PIN, LOCKNUT, OR DOUBLE NUT. LEGACY COMPONENT DESC: Pin
Due 22 November 2002
Resolved 19 November 2002
Lifesaving › Lifejacket/PFD (Type I)
Issued 7 November 2002 Resolved
PROVIDE 15 ADDITIONAL ADULT TYPE I PFD'S. VESSEL IS RESTRICTED TO CARRYING 37 TOTAL PERSONS UNTIL CORRECTED. LEGACY COMPONENT DESC: Quantity
Due 22 November 2002
Resolved 19 November 2002
Electrical
Issued 7 November 2002 Resolved
RE-ATTACH FAN TO FORWARD PORT BERTH OR REMOVE FAN AND ALL ASSOCIATED WIRING.
Due 22 November 2002
Resolved 19 November 2002
Engineering › Fuel Oil Storage/Transfer System
Issued 7 November 2002 Resolved
PROVIDE A FUEL TANK SHUT-OFF VALVE IAW 46CFR182.455 LEGACY COMPONENT DESC: Valve
Due 22 November 2002
Resolved 19 November 2002
Lifesaving
Issued 16 October 2001 Resolved
PROVIDE TWO TYPE I ADULT PFD'S. VESSEL IS RESTRICTED TO CARRYING 50 ADULTS UNTIL THIS REQUIREMENT IS MET.
Condition: Unknown
Due 16 October 2001
Resolved 16 October 2001
Construction/Loadline
Issued 16 October 2001 Resolved
PROVIDE VISUAL INDICATION AT OPERATING STATION OF BILGE PUMP OPERATION IN BOTH HULLS.
Condition: Unknown
Due 16 October 2001
Resolved 16 October 2001
Lifesaving
Issued 16 October 2001 Resolved
LABEL INSIDE OF EMERGENCY ESCAPE HATCH IAW 46 CFR 185.606
Condition: Unknown
Due 16 October 2001
Resolved 16 October 2001
Lifesaving
Issued 16 October 2001 Resolved
PROVIDE SIX TYPE I CHILD PFD'S. VESSEL RESTRICTED TO CARRYING ONLY ADULTS UNTIL THIS REQUIREMENT IS MET.
Condition: Unknown
Due 16 October 2001
Resolved 16 October 2001
Lifesaving
Issued 16 October 2001 Resolved
PROVIDE CREW TRAINING AND LOG.
Condition: Unknown
Due 16 October 2001
Resolved 16 October 2001
Lifesaving
Issued 16 October 2001 Resolved
REPAIR LIFEFLOATS AT SERVICE FACILITY OR REPLACE. _x001C_
Condition: Unknown
Due 24 October 2001
Resolved 7 November 2002
Documentation
Issued 9 November 1999 Resolved
PROVIDE PROOF OF EAP AND TRAINING IN DRUG TESTING PROGRAM.
Condition: Unknown
Due 19 January 2000
Resolved 19 January 2000
Lifesaving
Issued 9 November 1999 Resolved
RESTOW RING BUOY TO ALLOW FLOAT FREE AND MARK NAME ON BOTH SIDES.
Condition: Unknown
Due 19 January 2000
Resolved 19 January 2000
Lifesaving
Issued 9 November 1999 Resolved
PROVIDE AN APPROVED FIRST AID KIT IN ACCORDANCE WITH 46CFR160.041-4.
Condition: Unknown
Due 19 January 2000
Resolved 19 January 2000
Navigation
Issued 9 November 1999 Resolved
PROVIDE COPY OF NAVIGATION RULES OF THE ROAD.
Condition: Unknown
Due 19 January 2000
Resolved 19 January 2000
Lifesaving
Issued 9 November 1999 Resolved
REPLACE HYDRO RELEASE ON EPIRB.
Condition: Unknown
Due 19 January 2000
Resolved 19 January 2000
Lifesaving
Issued 9 November 1999 Resolved
INSTALL DETACHABLE CLIP ON RING BUOY LIGHT.
Condition: Unknown
Due 19 January 2000
Resolved 19 January 2000
Documentation
Issued 9 November 1999 Resolved
PROVIDE AND POST COPY OF STABILITY LETTER AND SAIL ARRANGEMENT.
Condition: Unknown
Due 19 January 2000
Resolved 19 January 2000
Lifesaving
Issued 9 November 1999 Resolved
PROVIDE WRITTEN PROCEDURE FOR MOB RESCUE, UTILIZE HANDHELD RADIOS TO MAINTAIN CONTACT WITH DECKHAND.
Condition: Unknown
Due 19 January 2000
Resolved 19 January 2000
Lifesaving
Issued 23 November 1998 Resolved
RENEW RETRO TAPE ON NUMEROUS ADULT AND CHILD PFD'S. _x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 December 1998
Resolved 22 December 1998
Lifesaving
Issued 23 November 1998 Resolved
INSTALL 3-6' OF LINE ON RING BUOY WATERLIGHT W/HALYARD CLIP ON END OF LINE THAT ATTACHES TO RING BUOY._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 December 1998
Resolved 22 December 1998
Fire Fighting
Issued 23 November 1998 Resolved
SERVICE ALL FIRE EXTINGUISHERS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 December 1998
Resolved 22 December 1998
Lifesaving
Issued 23 February 1998 Resolved
INSTALL MEANS OF CORDONING OFF AREA FORWARD OF THE DECK HOUSE WITH ROPE, CHAIN OR RAILING ARRANGEMENT THAT CAN BE REMOVED TO ALLOW A DECKHAND TO GO FORWARD WHEN NECESSARY.
Condition: Unknown
Due 23 February 1998
Resolved 23 February 1998
Accommodation/Occupational Safety
Issued 8 December 1994 Resolved
Lable 2 aft hatches "Emergency Escape - Keep Clear".
Condition: Unknown
Due 6 January 1995
Resolved 6 January 1995
Unknown
Issued 8 December 1994 Resolved
Provide proof of drug testing - consortive membership.
Condition: Unknown
Due 6 January 1995
Resolved 6 January 1995
Lifesaving
Issued 8 December 1994 Resolved
Provide 3 additional red flares.
Condition: Unknown
Due 6 January 1995
Resolved 6 January 1995
Lifesaving
Issued 8 December 1994 Resolved
Renew ring buoy or repair beckett line.
Condition: Unknown
Due 6 January 1995
Resolved 6 January 1995
Documentation
Issued 11 December 1991 Resolved
PROVIDE FCC CERT. VESSEL LIMITED TO NOT MORE THAN 1000 FT FROM SHORE UNTIL COMPLETED.
Condition: Unknown
Due 10 February 1992
Resolved 10 February 1992
Lifesaving
Issued 11 December 1991 Resolved
PROVIDE WATERTIGHT CONTAINER FOR SIGNALLING DEVICES.
Condition: Unknown
Due 10 February 1992
Resolved 10 February 1992
Deck/Cargo
Issued 11 December 1991 Resolved
CONDUCT DYE TEST OF FWD STAY SUPPORT IN PRESENCE OF A USCG INSPECTOR
Condition: Unknown
Due 10 February 1992
Resolved 10 February 1992
Lifesaving
Issued 11 December 1991 Resolved
PROVIDE EMERGENCY CHECK-OFF LIST.
Condition: Unknown
Due 10 February 1992
Resolved 10 February 1992
Lifesaving
Issued 11 December 1991 Resolved
PROVIDE ONE ADDITIONAL CHILD PFD. NO MORE THAN 5 CHILD PASSENGERS ALLOWED UNTIL COMPLETED.
Condition: Unknown
Due 10 February 1992
Resolved 10 February 1992
Accommodation/Occupational Safety
Issued 26 December 1990 Resolved
PROVIDE A MEANS TO PUMP SEWAGE TANKS ASHORE TO A RECEPTION FACILITY.
Condition: Unknown
Due 26 December 1990
Resolved 26 December 1990
Accommodation/Occupational Safety
Issued 26 December 1990 Resolved
PROVIDE A MEANS TO SECURE SEWAGE OVERBOARD VALVES IN THE CLOSED POSITION AND POST SIGNS STATING VALVES MUST REMAIN IN THE CLOSED POSITION WHILE OPERATING WITHIN TERRITORIAL WATERS.
Condition: Unknown
Due 26 December 1990
Resolved 26 December 1990
Accommodation/Occupational Safety
Issued 26 December 1990 Resolved
CLOSE IN SPACE BETWEEN RAILING COURSES WITH CHAIN LINK FENCING. WIRE MESH OR THE EQUIVALENT.
Condition: Unknown
Due 26 December 1990
Resolved 26 December 1990
Documentation
Issued 26 December 1990 Resolved
PROVIDE FCC CERTIFICATE.
Condition: Unknown
Due 26 December 1990
Resolved 26 December 1990

Casualty record · 2

24 October 2005Routine · role: Involved in a Marine Casualty · activity 2564218
6 March 2018Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6366850
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.