LYKTOS

LYKTOS is a 1986 freight ship. The Coast Guard has recorded 95 inspections since 1990, most recently in February 2026, along with 51 deficiencies and 12 operational controls, 1 with no removal date recorded.

Records from 1990 to 2026. Most recent: inspection, 12 February 2026.

Built
1986
Last inspected
12 February 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

8401145 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
355179
Flag
MARSHALL ISLANDS
—
Maury page id
psix-355179

Inspections, by type

…with no type recorded45
Years with a record 28 calendar years (1990–2026)
The 95 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it15375 - Convention (Subpart B), Gross Ton
6014 - Convention (Subpart B), Net Ton
9338 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 95

12 February 2026 PSC B · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8309339
30 September 2025 PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8237309
23 July 2025 Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8192476
23 March 2025 PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8094989
22 January 2025 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8067578
20 September 2024 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8006412
22 August 2023 Explosive Handling Operation-Commercial
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7770306
24 July 2023 Explosive Handling Operation-Commercial
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7750985
7 July 2023 Explosive Handling Operation-Commercial
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7735785
20 June 2023 Explosive Handling Operation-Commercial
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7714178
30 May 2023 Explosive Handling Operation-Commercial
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7700648
20 May 2023 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7692612
15 May 2023 Explosive Handling Operation-Administrative
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7688537
27 April 2023 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7676895
25 April 2023 ISPS Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7675469
17 April 2023 Explosive Handling Operation-Commercial
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7670281
14 March 2023 Explosive Handling Operation-Commercial
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7650809
21 February 2023 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7639266
21 February 2023 Explosive Handling Operation-Commercial
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7639517
10 February 2023 Explosive Handling Operation-Commercial
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7634926
7 January 2023 Explosive Handling Operation-Commercial
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7617852
7 August 2022 Explosive Handling Operation-Commercial
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7526718
1 August 2022 Explosive Handling Operation-Commercial
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7522362
5 May 2022 Administrative Inspection · ISPS Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7444368
15 March 2022 PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7410546
7 September 2021 Ballast Water Examination · PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7301004
23 March 2021 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7162882
22 March 2021 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7160719
16 March 2021 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7157196
6 March 2021 PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7150783
28 February 2021 ISPS Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7147479
14 February 2021 ISPS Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7140547
2 September 2020 PSC B
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7048174
11 June 2020 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6973603
10 June 2020 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6972805
4 March 2020 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6920246
2 March 2020 PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6916889
27 August 2019 Ballast Water Examination · ISPS II Exam · PI Safety Exam · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6768701
6 August 2019 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6768485
8 March 2009 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3420310
9 August 2008 MARPOL Annex I Examination · ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3293481
2 January 2008 ISPS II Exam · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3123312
21 April 2007 ISPS II Exam · PII Safety Exam · Ballast Water Examination · STCW 95 Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2912260
25 September 2006 Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2786287
24 September 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2785762
4 April 2006 NPV Safety Exam · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2616781
8 February 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2581745
1 February 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2577582
2 August 2005 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2448681
21 July 2005 NPV Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2434765
22 May 2005 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2364594
27 April 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2343991
4 April 2005 Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2326732
7 February 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2287981
19 November 2004 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2244588
15 October 2004 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2221690
12 October 2004 NPV Safety Exam · Ballast Water Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2218772
29 June 2004 Random ISPS/MTSA/PSC
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2115524
12 January 2004 Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1981822
15 May 2003 Administrative Inspection
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1794053
11 March 2003 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1755977
29 July 2002 Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1653488
5 March 2002 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1491222
4 February 2002 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1485088
6 August 2001 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 292659
5 July 2001 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 291584
6 January 2000 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 273380
1 December 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 435260
7 April 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 484228
30 November 1998 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 423121
4 November 1998 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 422296
8 March 1998 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 158904
1 October 1997 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 408503
3 January 1997 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 399113
8 September 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 395272
2 June 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 391854
3 March 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 388532
3 September 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 382372
30 July 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 381266
13 August 1994 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1180955
2 August 1994 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 369095
30 April 1994 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 61972
17 August 1993 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 360549
17 July 1993 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 359952
7 February 1993 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 356257
2 July 1992 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 672125
3 June 1992 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 490116
21 May 1992 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 351009
24 April 1992 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 350649
27 January 1992 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 348473
27 January 1992 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 672124
7 October 1991 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 672127
7 August 1991 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 346339
3 April 1991 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 914966
28 September 1990 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 339587

Deficiency record · 51

07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 February 2026 Resolved
FIRE EXTINGUISHERS SHALL BE PERIODICALLY EXAMINED AS THE ADMINISTRATION MAY REQUIRE. PSCO OBSERVED MONTHLY CHECK TAGS ON EXTINGUISHERS THAT HAD NOT BEEN FILLED OUT IN UP TO 7 MONTHS THROUGHOUT THE SHIP, THEREFORE, PSCO COULD NOT DETERMINE IF MONTHS CHECKS IAW SMS PROCEDURES WERE CARRIED OUT. UPON REVIEW OF THE VESSELS SMS AND DISCUSSION WITH CREW, PSCO DETERMINED 3RD OFFICER DID NOT CONDUCT CHECKS IAW THE SMS. 74 SOLAS II-2/7(e) 16AC
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 February 2026
Resolved 26 February 2026
Resolution: Reviewed class report, attests to proper recordkeeping and verification of FF equipment.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 February 2026 Resolved
BEFORE THE SHIP LEAVES PORT AND AT ALL TIMES DURING THE VOYAGE ALL LIFESAVING APPLIANCES SHALL BE IN WORKING ORDER AND READY FOR IMMEDIATE USE. 02 LIFEJACKETS IN THE PASSAGE WAY ABOVE THE ECR LOCATED IN THE ENGINE ROOM HAD INOPERABLE LIGHTS.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 February 2026
Resolved 12 February 2026
Resolution: VERIFIED CORRECTION PRIOR TO DEPARTURE.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 12 February 2026 Resolved
PLANS AND BOOKLETS SHALL BE KEPT UP TO DATE, ANY ALTERATIONS BEING RECORDED THEREON AS SOON AS PRACTIBLE. PSCO OBSERVED STOWAGE OF LIFE JACKETS AND IMMERSION SUITS STOWED OUTSIDE OF THE ENGINE CONTROL ROOM AS INDICATED IN THE FIRE CONTROL PLAN.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 February 2026
Resolved 12 February 2026
Resolution: VERIFIED CORRECTION PRIOR TO DEPARTURE.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 12 February 2026 Resolved
BEFORE THE SHIP LEAVES PORT AND AT ALL TIMES DURING THE VOYAGE ALL LIFESAVING APPLIANCES SHALL BE IN WORKING ORDER AND READY FOR IMMEDIATE USE. 01 IMMERSION SUIT LOCATED IN THE ENGINE ROOM HAD INOPERABLE LIGHTS. 74 SOLAS(2020) III/20.2 16AC
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 February 2026
Resolved 12 February 2026
Resolution: VERIFIED CORRECTION PRIOR TO DEPARTURE.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 February 2026 Resolved
THE SELF IGNIGHTING LIGHT SHALL BE CAPABLE OF BURNING FOR NOT LESS THAT 45 MINUTES AND SHALL HAVE A LUMINOUS INTENSITY OF NOT LESS THAN 2 CANDELAS. PSCO OBSERVED 02 INOPERABLE LIFE BUOYS LIGHT LOCATED ON THE PORTSIDE DECK. 74SOLAS III/21(f) 16AC
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 February 2026
Resolved 12 February 2026
Resolution: VERIFIED CORRECTION PRIOR TO DEPARTURE.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 May 2023 Resolved
Vessel experienced loss of propulsion due to faulty oil filtering equipment.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 May 2023
Resolved 20 May 2023
Resolution: Filter replaced, class survey submitted. Review documents.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 March 2021 Resolved
Lifebuoys complying with the requirements of paragraph 7.1.1 of the code shall be stowed as to be capable of being rapidly cast loose and not permenently secured in any way. Port side quick release lifebuoy was not able to cast losse when released. Cite: 74 SOLAS(14)111 7.1.1.2
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 6 March 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 March 2021 Resolved
The steering gear compartment shall be provided with suitable arragnments to ensure working access to steering gear machinery and controls. These arrangments shall include hand rails and gratings or other non-slip surfaces to ensure sutable working conditions in the even of hydraulic fluid leakage. Floor was slick leading to steering gear with build up of fluid. Cite: 74 SOLAS(81)11-1 29.13.2
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2021
Resolved 22 March 2021
Resolution: Recieved pictures from vessel captain showing appropriate non-slip surfaces and hand rails being implemented.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 6 March 2021 Resolved
Every ship of 110 gross tonnage and above, and every ship which is certified to carry 15 or more person shall carry a garbage management plan which the crew shall follow. PSCOs observed crew violating plan as far as garbage segregation. Cite: MARPOL Annex V 10.2
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2021
Resolved 16 March 2021
Resolution: Vessel provided documentation showing proper segregation of garbage.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 March 2021 Resolved
The ring lines and letters shall be pained in white or yellow on a dark ground or in black on a light ground. Deck line and load lines are not painted and deck line is not easily noticeable. Cite: ICLL 8
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 March 2021
Resolution: Vessel provided pictures as evidence of re-painting deck line and load lines.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 March 2021 Resolved
No person may cause a vessel to enter into the navigable waters of the United States unless no more than 12 hrs before entering the following equipment outlined in 33CFR164.25(a) is checked. PSCOs could not locate prior to entry checks. Cite: 33CFR164.25
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 March 2021
Resolution: Vessel provided a copy of pre-arrival checklist and logbook entry dated 07MAR21
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 27 August 2019 Resolved
A daylight signaling lamp or other means to communicate by light during day and night using an energy source of electrical power not solely dependent upon ship’s power supply. The vessel does not have a portable battery for the daylight signaling lamp.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 September 2019
Resolved 9 September 2019
Resolution: recieved images of operational signaling lamp and battery
14 - Pollution Prevention › 141 - MARPOL Annex I › Retention of oil on board
Issued 27 August 2019 Resolved
Every ship other than an oil tanker 400 gross tons and above shall carry onboard a shipboard oil pollution emergency plan approved b the Administration. A sparking shovel was discovered in the SOPEP locker.
Action required: 10 - Deficiency Rectified
Resolved 27 August 2019
Resolution: Deficiency fixed on the spot.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 9 August 2008 Resolved
Have Flag provide test/periodic exam requirments.
Action required: 705 - Other - as specified
Due 8 September 2008
Resolved 19 September 2008
Resolution: Ship provided Sector Miami with Maintenance and Inspection of Fire-Protection Systems and Appliances attesting to the inspection of the fire extinguishers every two years.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 9 August 2008 Resolved
Have Flag attest to update of Ship's Saftey Management System annual test requirements for portable fire extinguishers.
Action required: 705 - Other - as specified
Due 8 September 2008
Resolved 19 September 2008
Resolution: Ship provided Sector Miami with Maintenance and Inspection of Fire-Protection Systems and Appliances attesting to the inspection of the fire extinguishers every two years.
Personnel › Training › Familiarization Training
Issued 21 April 2007 Resolved
Master (Preben K. Jensen) and Chief Engineer (Stefan S. Knudsen) do not have STCW training within past 5 years, waived by administration. Provide record of exemption by flag.
Action required: 705 - Other - as specified
Due 5 May 2007
Resolved 25 June 2007
Resolution: Letter provided by flag.
Documentation › Certificates/Documents › International Load Line Certificate
Issued 21 April 2007 Resolved
Loadline certificate with valid dates not available on vessel. Vessel has documentation for renewal survey.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 25 June 2007
Resolution: Faxed document to office.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 21 April 2007 Resolved
Fire suit found in fire locker not SOLAS approved.
Due 5 May 2007
Resolved 25 June 2007
Resolution: Receipt faxed to office.
Engineering › Electric Propulsion System › Wiring
Issued 21 July 2005 Resolved
Provide Classification Society Report attesting to proper operation of main engine controllable pitch propellar system prior to departure in accordance with SOLAS Ch. II-1/Part C/Reg. 26
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 August 2005
Resolution: Admin faxed survey to [name withheld] attesting to the proper operation of engine controllable pitch propeller.
Engineering › Steering Gear System › Pump
Issued 22 May 2005 Resolved
#1 Steering Pump is inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 May 2005
Engineering › Diesel Engine (propulsion-direct drive) › Turbocharger
Issued 15 October 2004 Resolved
Provide report by Classification Society identifying the cause of the main engine turbocharger failure and provide report attesting to the repair and satisfactory operation. "
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 October 2004
Resolution: Turbo was overhauled by Turbousa Inc. and certified by DNV Surveyor Nils-Bjorn Raae from New Orleans.
Fire Fighting › Structural - A Class Divisions
Issued 29 July 2002 Resolved
Repair/replace FSD (Fire Screen Door) leading to 2nd Deck from work shop excessive wastage on bottom of door. Door does not close properly. Have class attest to the repair. LEGACY COMPONENT DESC: Openings - Fire Doors
Due 29 August 2002
Resolved 19 August 2002
Resolution: Door and framing was repaired, and Class approved repair.
Fire Fighting › Structural - A Class Divisions
Issued 29 July 2002 Resolved
Have class address hole in bulkhead in workshop leading to the boiler room. LEGACY COMPONENT DESC: Bulkheads - Workshops
Due 29 August 2002
Resolved 19 August 2002
Resolution: New plating was installed.
Lifesaving › Launching Appliances
Issued 29 July 2002 Resolved
Repair stbd wench drum guard (Fly Wheel Guard) so that polyline is not used to secure the system and wheel is not rubbing on guard. LEGACY COMPONENT DESC: Winch Brake
Due 29 August 2002
Resolved 19 August 2002
Resolution: Hardware was installed to correct problem.
Lifesaving › Lifebuoys
Issued 29 July 2002 Resolved
Replace all poly line on life rings both grab line and buoyant lifeline IAW SOLAS (2001 Consolidated) III/7.1. LEGACY COMPONENT DESC: Buoyant Lifeline
Due 29 August 2002
Resolved 19 August 2002
Resolution: All life rings were checked and were sat.
Engineering › Steam System (auxiliary)
Issued 29 July 2002 Resolved
Repair lagging on hot water pipe on 1st deck, FR 157 (Hot opened piping). LEGACY COMPONENT DESC: Lagging/Insulation
Due 29 August 2002
Resolved 19 August 2002
Resolution: New lagging was installed.
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 29 July 2002 Resolved
Provide operating instructions on or near "Halon Release Cabinet" stbd side aft. LEGACY COMPONENT DESC: Operating Controls
Due 29 August 2002
Resolved 19 August 2002
Resolution: Instructions have been placed inside of control cabinet.
Navigation › Piloting/Steering
Issued 29 July 2002 Resolved
Update compass deviation table. LEGACY COMPONENT DESC: Deviation Table/Graph
Action required: 15 - Rectify deficiencies by next port
Resolved 19 August 2002
Resolution: An updated compass deviation table has been placed on bridge.
Lifesaving
Issued 5 July 2001 Resolved
Provide nonconductive mat in way of emergency diesel generator switchboard.
Condition: Unknown
Due 8 August 2001
Resolved 8 August 2001
Lifesaving
Issued 5 July 2001 Resolved
Provide lifeboat launching instructions in language of crew at embarkation deck (port & stbd).
Condition: Unknown
Due 8 August 2001
Resolved 8 August 2001
Navigation
Issued 5 July 2001 Resolved
Provide emergency steering instructions and block diagram in steering flat.
Condition: Unknown
Due 5 July 2001
Resolved 5 July 2001
Documentation
Issued 1 December 1999 Resolved
Prior to next U.S. port, provide medical certificates for all crewmembers. Certificates may be faxed to MSO Miami.
Condition: Unknown
Due 6 January 2000
Resolved 6 January 2000
Engineering
Issued 4 November 1998 Resolved
Provide class report addressing operation of Oily water separator. Chief engineer ordered sensor and alarm and once installed, class will test operation. Class surveyor in attendance of exam.
Condition: Unknown
Due 30 November 1998
Resolved 30 November 1998
Documentation
Issued 4 November 1998 Resolved
Provide SOLAS training manual for lifesaving in language of crew (Croatian)._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 November 1998
Resolved 30 November 1998
Documentation
Issued 4 November 1998 Resolved
Provide firefighting manual in language of crew (Croatian)._x001C_
Condition: Unknown
Due 30 November 1998
Resolved 30 November 1998
Navigation
Issued 8 September 1996 Resolved
REPAIR LEAKING PACKING FROM AFT HYDRAULICS/EMERGENCY STEERING.
Condition: Unknown
Due 4 January 1997
Resolved 4 January 1997
Navigation
Issued 8 September 1996 Resolved
PROVIDE CURRENT COPY OF THE TIDAL CURRENT TABLES IAW 33 CFR 164.33.
Condition: Unknown
Due 4 January 1997
Resolved 4 January 1997
Unknown
Issued 8 September 1996 Resolved
Conduct fire and abandon ship drills in the presence of a marine inspector after return from drydock.
Condition: Unknown
Due 4 January 1997
Resolved 4 January 1997
Electrical
Issued 30 July 1995 Resolved
Provide documentation from class society that annual automation survey- required for periodically unattended machinery spaces- has been completed satisfactorily. The vessel has a reduced manning for engineers, see safe manning certificate._x001C_
Condition: Unknown
Due 4 August 1995
Resolved 14 August 1995
Fire Fighting
Issued 30 July 1995 Resolved
Certification from class society on repairs to Halon system._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 September 1995
Resolved 3 September 1995
Fire Fighting
Issued 2 August 1994 Resolved
REPAIR #1 FIRE PUMP AND PROVIDE CERTIFICATION FROM CLASS THAT PUMP OPERATESSATISFACTORY.
Condition: Unknown
Due 19 August 1994
Resolved 19 August 1994
Unknown
Issued 2 August 1994 Resolved
FREE UP VENT COVERS FOR THE EMERGENCY GENERATOR
Condition: Unknown
Due 11 August 1994
Resolved 11 August 1994
Navigation
Issued 2 August 1994 Resolved
PROVIDE BLOCK DIAGRAM OF EMERGENCY STEERING CHANGE OVER
Condition: Unknown
Due 19 August 1994
Resolved 19 August 1994
Unknown
Issued 2 August 1994 Resolved
FREE UP BOLTS ON INTERNATIONAL SHORE CONNECTION
Condition: Unknown
Due 11 August 1994
Resolved 11 August 1994
Unknown
Issued 2 August 1994 Resolved
REPAIR REMOTE STOPS FOR EMERGENCY GENERATOR AND DIRTY OIL PUMP AND PROVIDE CLASS CERTIFICATION
Condition: Unknown
Due 19 August 1994
Resolved 19 August 1994
Engineering
Issued 2 August 1994 Resolved
REPAIR AUTOMATIC OPERATION OF OWS AND PROVIDE CERTIFICATION FROM CLASS THATSYSTEM OPERATES IAW ALL CURRENT REGULATIONS (OWS ONLY OPERATES IN MANUAL MODE).
Condition: Unknown
Due 19 August 1994
Resolved 19 August 1994
Fire Fighting
Issued 2 August 1994 Resolved
PROVIDE CERTIFICATION FROM CLASS THAT PORTABLE FIRE EXTINGUISHERS CAN STORED IN A CENTRAL LOCKER
Condition: Unknown
Due 19 August 1994
Resolved 19 August 1994
Documentation
Issued 24 April 1992 Resolved
A violation of 46CFR42.07-05(a) in that the deckline was not permanently marked on the side of the vessel. Vessel subject to U.S. regulations per 46CFR2.01-13(b).
Condition: Unknown
Due 16 June 1992
Resolved 16 June 1992
Construction/Loadline
Issued 27 January 1992 Resolved
"A violation of 46CFR42.07-5(a) in that the deckline was not permanently marked on the side of the vessel. Vessel subject to U.S. regulations per 46CFR 2.01-13(b)_x001C_ _x001C_
Condition: Unknown
Due 16 June 1992
Resolved 16 June 1992
Documentation
Issued 7 August 1991 Resolved
Oil transfer procedures was missing (a)(1)(i), (a)(2)(iii), (a)(7), (a)(8) of 33 CFR 155.750.
Condition: Unknown
Due 27 January 1992
Resolved 27 January 1992
Construction/Loadline
Issued 7 August 1991 Resolved
"A violation of 46 CFR 42.07-1(a) in that the deckmark was not permanently marked on the side of the vessel. Vessel subject to U. S. regulations per 46 CFR 2.01-13(b)."_x001C_ _x001C_
Condition: Unknown
Due 16 June 1992
Resolved 16 June 1992

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.