Records from 1990 to 2025. Most recent: inspection, 23 May 2025.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 34
23 May 2025
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8142347
20 October 2023
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7791033
14 October 2022
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7576651
12 October 2021
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7330874
29 July 2020
COI Inspection · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7013429
24 October 2019
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6840877
2 January 2019
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6604890
15 December 2017
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6305457
6 October 2016
Internal Structural Exam · Administrative Inspection · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6016521
16 October 2015
Drydock Exam · Internal Structural Exam · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5744272
28 September 2010
Hull Examination · Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3859016
7 January 2010
Examination of Repairs
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3660762
9 December 2009
Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3647469
15 January 2009
Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3394860
1 July 2008
Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3257737
21 February 2007
Administrative Inspection · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2864717
28 November 2005
COI Inspection · Hull Examination
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2538989
30 September 2004
Annual Inspection
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2208400
26 August 2003
Annual Inspection
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 1886480
18 September 2001
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1426659
22 September 2000
Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1401325
18 September 2000
Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 1557545
22 September 1999
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1465505
23 September 1998
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1392985
20 September 1997
Deficiency Check · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1438645
26 September 1996
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1425794
2 November 1995
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1189542
12 September 1995
Re-Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1427109
22 September 1994
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1401928
29 September 1993
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1407202
18 September 1992
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1458972
25 September 1991
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1246493
7 May 1991
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 921400
4 October 1990
Hull Examination · Initial Certification
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 909603
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 November 2019
Resolved
Vessel was missing it's 3 - 2.5 gallon fire buckets.
Action required: 10 - Deficiency Rectified
Due 4 November 2019
Resolved 4 November 2019
Resolution: Corrected on site.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 4 November 2019
Resolved
Vessel's VHF radio didn't display GPS location and didn't have the MMSI programmed in.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 December 2019
Resolved 14 November 2019
Resolution: GPS wired to radio and position displayed.
Fire Fighting › Remote Fuel Shutoff › General
Issued 9 December 2009
Resolved
Label fuel shut off valves.
Action required: 705 - Other - as specified
Due 9 January 2010
Resolved 7 January 2010
Resolution: Attended subject vessel to verify and inspect three deficiencies.
1. Fuel shut off valves were properly labeled with directions for operation.
2. All fuel lines running from the fuel tank to the outboard motor were replaced.
3. Faded safety placards
Engineering › Fuel Oil Service System › Hose
Issued 9 December 2009
Resolved
Replace 3 fuel hoses.
Action required: 705 - Other - as specified
Due 9 January 2010
Resolved 7 January 2010
Resolution: Attended subject vessel to verify and inspect three deficiencies.
1. Fuel shut off valves were properly labeled with directions for operation.
2. All fuel lines running from the fuel tank to the outboard motor were replaced.
3. Faded safety placards
Accommodation/Occupational Safety › Occupational Safety › Smoking
Issued 9 December 2009
Resolved
Replace faded warning placards.
Action required: 705 - Other - as specified
Due 9 January 2010
Resolved 7 January 2010
Resolution: Attended subject vessel to verify and inspect three deficiencies.
1. Fuel shut off valves were properly labeled with directions for operation.
2. All fuel lines running from the fuel tank to the outboard motor were replaced.
3. Faded safety placards
Lifesaving
Issued 20 September 1997
Resolved
PROVIDE THREE ADDITIONAL TYPE I ADULT LIFEJACKETS ON BOARD VESSEL. TOTAL ADULT PASSENGERS ARE RESTRICTED TO 15 UNTIL THIS ITEM IS CORRECTED.
Condition: Unknown
Due 30 September 1997
Resolved 3 October 1997
Documentation
Issued 20 September 1997
Resolved
PROVIDE COPY OF STABILITY LETTER ON BOARD VESSEL.
Condition: Unknown
Due 17 October 1997
Resolved 3 October 1997
Documentation
Issued 12 September 1995
Resolved
PROVIDE SATISFACTORY DOCUMENTATION THAT THE MARINE EMPLOYER HAS AN ESTABLISHED CHEMICAL TESTING PROGRAM AS IDENTIFIED IN 46 CFR PART 16.
Condition: Unknown
Due 12 September 1995
Resolved 12 September 1995