ANDREWS

ANDREWS is a 1990 passenger vessel (inspected). The Coast Guard has recorded 63 inspections since 1990, most recently in March 2024, along with 69 deficiencies and 1 casualty investigation in 2016.

Records from 1990 to 2024. Most recent: inspection, 28 March 2024.

Built
1990
Last inspected
28 March 2024
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDB6836
355518
Flag
UNITED STATES
366931430 (licence lapsed)
Maury page id
psix-355518

Inspections, by type

…with no type recorded7
Years with a record 31 calendar years (1990–2024)
The 63 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it42 - Simplified, Gross Ton
40 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDB6836MMSI 366931430 · expired · compulsorily equipped · granted 25 February 2014, cancelled 18 May 2024
WAQ5010MMSI not assigned · expired · compulsorily equipped · granted 16 May 1997, cancelled 11 March 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 63

28 March 2024 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7886263
12 April 2023 Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7667375
20 January 2023 Examination of Repairs
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7623316
4 October 2022 COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7567298
1 August 2022 Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7517677
17 November 2021 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7359640
8 October 2020 Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7073952
28 July 2020 Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7018129
14 July 2020 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7011018
19 November 2019 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6858191
19 November 2019 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6858639
23 October 2019 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6840413
6 December 2018 Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6592943
17 July 2018 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6483606
17 October 2017 Deficiency Check · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6288780
25 May 2017 Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6160326
17 January 2017 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6069736
20 July 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5946719
19 July 2016 Damage Survey · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5946850
7 July 2016 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5932731
13 January 2016 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5796677
16 June 2014 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4889928
25 March 2014 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4822752
26 July 2012 Hull Examination · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4390852
1 December 2011 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4199416
29 October 2010 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3877753
24 September 2008 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3331523
29 July 2008 Examination of Repairs · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3285175
26 October 2006 Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2808388
27 July 2006 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2726295
24 October 2005 Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2521198
30 September 2004 Re-Inspection · Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2209567
14 July 2004 Deficiency Check · Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2138316
24 October 2003 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1935000
2 July 2002 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1639872
20 November 2001 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1454992
9 August 2000 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1427875
26 July 2000 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1393489
27 June 2000 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1053355
24 November 1999 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1408403
29 June 1999 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 730979
13 May 1999 Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1131151
7 May 1999 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 211127
2 December 1998 Deficiency Check · MARPOL Annex V Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1415091
18 May 1998 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 794405
22 December 1997 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 780954
8 December 1997 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1408036
2 October 1997 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 784848
15 May 1997 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1105302
6 January 1997 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 784727
19 December 1996 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1096791
25 November 1996 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1181268
18 June 1996 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 885596
4 December 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 882036
30 November 1995 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 882035
1 December 1994 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1181702
3 June 1994 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1014588
8 December 1993 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1399946
17 November 1992 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1138244
27 May 1992 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 954464
30 October 1991 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1251995
30 November 1990 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 934709
30 November 1990 Initial Construction-Excluding Oversight · Initial Certification · Hull Examination · Plan Review "T" Boat
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1218331

Deficiency record · 69

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 October 2022 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in normally unmanned spaces. The alarms for the high level were inoperable.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 April 2023
Resolution: Verified the operation of the high level alarm.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 October 2022 Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. The vessel had three bilge pumps, but only 1 indicator.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 April 2023
Resolution: Vessel has an operable indicator for each bilge pump.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 4 October 2022 Resolved
A vessel of less than 12 meters in length shall not be obliged to carry the sound signaling appliances prescribed in paragraph (a) of this Rule but if she does not, she shall be provided with some other means of making an efficient sound signal. The vessel's sound signal is inoperable.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 April 2023
Resolution: Vessel now has a operable sound signaling device.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 October 2020 Resolved
Each ring buoy on a vessel must be approved in accordance with 46 CFR 160.050 in subchapter Q. The grab lines on the ring buoy are deteriorated and no longer serviceable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 October 2020
Resolved 5 November 2020
Resolution: Received photo showing a new ring buoy with the vsls name on it.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 19 November 2019 Resolved
The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties during emergencies that necessitate abandoning ship or the recovery of persons who have fallen overboard. Unable to get vessel underway for drills. Schedule and conduct drill in presence of marine inspector prior to carrying passengers.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 28 July 2020
Resolution: Conducted satisfactory MOB drill.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 19 November 2019 Resolved
The master shall conduct sufficient fire drills to make sure that each crew member is familiar with his or her duties in case of a fire. Unable to get vessel underway for drills. Schedule and conduct drill in presence of marine inspector prior to carrying passengers.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 28 July 2020
Resolution: Conducted satisfactory (verbal) fire drill.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 19 November 2019 Resolved
Battery terminals shall be of the soldered type and all connections shall be made to the battery terminals with permanent type connectors. Spring clips or other temporary type clamps are not permitted. Wing nuts bolts found on battery terminals in all battery banks. Remove wing nut bolts. Replace wing nut bolts with standard bolts.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 December 2019
Resolved 5 December 2019
Resolution: Wing nuts replace with locknuts on all batter terminals.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 19 November 2019 Resolved
Each vessel must have a stability letter issued by the Coast Guard before the vessel is placed in service. This letter sets forth conditions of operation. Vessel has opening in hull on fwd port engine room. Opening has black hose attached with no means of controlling water entrance into the hull. Provide means of sealing opening.
Action required: 705 - Other - as specified
Due 6 December 2019
Resolved 5 December 2019
Resolution: Hose removed and penetration piping permanently capped.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 19 November 2019 Resolved
A submersible electric bilge pump may be used as a power bilge pump required by Table 182.520(a) only on a vessel of not more than 19.8 meters (65 feet) in length carrying not more than 49 passengers, other than a ferry, provided that A positive shutoff valve is installed at the hull penetration. Check valves found installed on all electrical submersible pum overboard discharges. Remove check valves and install positive action valves at hull penetration.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 December 2019
Resolved 12 December 2019
Resolution: Check valves replaced with positive action valves for all 03 bilge pump overboards.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 December 2018 Resolved
Through hull fittings shall be metal. Through hull fitting for bilge pump hose in lazarette is plastic. 46CFR182.40-1(a)(3)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 December 2018
Resolved 2 January 2019
Resolution: Metal through hull fitting installed.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 6 December 2018 Resolved
Inspection shall be IAW standards acceptable to the OCMI, as good marine practice. Descale hull under ceramic plate in E/R aft of engine for further inspection. 46CFR176.25-1(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 December 2018
Resolved 2 January 2019
Resolution: Hull under ceramic plate re-inspected, all sat.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 6 December 2018 Resolved
As appropriate for the intended voyage, a vessel must carry up-to-date charts. Charts onboard vessel are out-of-date. 46CFR184.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 December 2018
Resolved 2 January 2019
Resolution: New up-to-date charts onboard vessel, all sat.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 17 October 2017 Resolved
Provide 30x30 mesh flame screen for port fuel tank vent. 46 CFR 182.20-35(d)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 October 2017
Resolved 7 November 2017
Resolution: Vessel rep. installed 30x30 mesh in vent.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 17 October 2017 Resolved
Install bonding wires across flexible piping in port and starboard fuel fill lines. 46 CFR 182.20-30(d)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 October 2017
Resolved 7 November 2017
Resolution: Bonding wires were installed on port and stbd fuel tanks.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 17 October 2017 Resolved
Repair fractured weld at base of the rail IWO starboard door. 46CFR177.35-1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2017
Resolved 7 November 2017
Resolution: Fractured weld was repaired.
Construction/Loadline › Hull › Bottom Plating
Issued 20 July 2016 Resolved
Provide repair proposal for crack on hull plating in E/R by aft bulkhead under shaft. Prior to carrying passengers.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 23 July 2016
Resolved 22 July 2016
Resolution: Witnessed satisfactory test of welded pinhole in hull.
Engineering › Shafting/Propeller Arrangements › Coupling Bolt
Issued 19 July 2016 Resolved
Prove proper operation of propulsion machinery prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 22 July 2016
Resolution: SAT underway sea trial conducted. VSL clutched in and out in FWD and REV.
Construction/Loadline › Hull › Bottom Plating
Issued 19 July 2016 Resolved
Crop and renew area where temporary weld repairs were made in way of shaft-log, port side from keel outboard.
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 25 May 2017
Resolution: Completed satisfactory air and soapy water test.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 13 January 2016 Resolved
Emergency Instruction List not onboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 January 2016
Resolved 13 January 2016
Resolution: Emergency Instruction List was provided upon return to the pier from conducting drills. Corrected on the spot.
Construction/Loadline › Hull › Bottom Plating
Issued 16 June 2014 Resolved
Found pitted area IWO keel in void #2 extending from fwd bulkhead to 6ft aft and 3 frames to port and stbd from keel. Crop/renew in kind.
Action required: 705 - Other - as specified
Due 30 September 2014
Resolved 24 September 2014
Resolution: Welded new plate and leak tested welds with high pressure water sprayed on welds.
Operations/Management › Drills/Instruction › Not Conducted
Issued 26 October 2012 Resolved
Vessel is currently not actively carrying passengers. Conduct man overboard/fire drills and underway operational tests prior to the carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 January 2014
Resolution: conducted drills SAT
Electrical › Electric Supply System (service) › Battery Charger
Issued 26 October 2006 Resolved
Make permanent repairs to starting system.
Due 26 October 2006
Resolved 30 October 2006
Resolution: reapaired sat.
Communications › Radio Communications › VHF Radiotelephone
Issued 24 October 2005 Resolved
Vessel restricted to 1000 feet from shore until proof of compliance with 47 CFR. Provide Radio Telephony Safety Certificate.
Action required: 705 - Other - as specified
Due 1 December 2005
Resolved 2 November 2005
Resolution: Reduced route on COI at request of owner.
Engineering › Fuel Oil Service System › Valve
Issued 30 September 2004 Resolved
Prove proper operation of the emergency fuel shut offs on the port and starboard fuel lines.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 6 October 2004
Resolved 5 October 2004
Resolution: Witnessed proper operation of emergency fuel shut-offs of the port ans stbd engines.
Electrical › Electrical Distribution System (service) › Wiring
Issued 30 September 2004 Resolved
Provide and install proper stuffing tube for the electrical wiring that passes through the aft watertight bulkhead to the lazzarette.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 October 2004
Resolved 5 October 2004
Resolution: Electrical wiring properly mounted through watertight bulkhead.
Construction/Loadline › Hull › Hull Plating
Issued 14 July 2004 Resolved
Prior to receiving credit drydock exam make proper repairs to damage on port bow.
Action required: 705 - Other - as specified
Due 19 July 2004
Resolved 19 July 2004
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 14 July 2004 Resolved
Repair or replace worn propeller. Due to lack of availability of replacement prop and vessel in service, it was agreed that the prop was adaquate till the end of the season.
Action required: 705 - Other - as specified
Due 31 July 2006
Resolved 31 July 2006
Resolution: Prop replaced sat.
Engineering › Bilge Water Management System › Pump
Issued 14 July 2004 Resolved
Replace bilge pump in #2 void space.
Action required: 705 - Other - as specified
Due 28 July 2004
Resolved 13 August 2004
Engineering › Bilge Water Management System › Pump
Issued 14 July 2004 Resolved
Properly mount all bilge pumps.
Action required: 705 - Other - as specified
Due 28 July 2004
Resolved 13 August 2004
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 14 July 2004 Resolved
Make proper repairs to base of stbd handrail in way of access gate.
Action required: 705 - Other - as specified
Due 28 July 2004
Resolved 19 July 2004
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 24 October 2003 Resolved
Properly mount B-II fire extinguisher. LEGACY COMPONENT DESC: Location
Action required: 705 - Other - as specified
Due 7 November 2003
Resolved 7 November 2003
Resolution: [name withheld] examined and found satisfactory.
Stability › Watertight Integrity
Issued 24 October 2003 Resolved
Replace rusted hose clamps as needed on overboard hoses.
Action required: 705 - Other - as specified
Due 7 November 2003
Resolved 7 November 2003
Resolution: [name withheld] examined and found satyisfactory new hose clamps.
Construction/Loadline › Markings
Issued 24 October 2003 Resolved
Install hailing port on stern. LEGACY COMPONENT DESC: Vessel Name/Home Port
Action required: 705 - Other - as specified
Due 7 November 2003
Resolved 7 November 2003
Resolution: [name withheld] examined and found satisfactory.
Documentation › Certificates/Documents
Issued 24 October 2003 Resolved
Provide copy of FCC radio station license. 07NOV03: Extended requirement to 28NOV03 at owner's request. 26Jan04 Advised owner rep that vessel is limited to less than 1000 ft from shore. LEGACY COMPONENT DESC: FCC SSL
Action required: 705 - Other - as specified
Due 28 November 2003
Resolved 18 March 2004
Accommodation/Occupational Safety › Occupational Safety
Issued 24 October 2003 Resolved
Make proper repairs to forward handrails. LEGACY COMPONENT DESC: Deck Rail
Action required: 705 - Other - as specified
Due 7 November 2003
Resolved 7 November 2003
Resolution: [name withheld] examined satisfactory weld repairs.
Documentation
Issued 26 July 2000 Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS, COMPLETE " NEW TO ZONE INSPECTION FOR CERTIFICATION "
Condition: Unknown
Due 9 August 2000
Resolved 9 August 2000
Electrical
Issued 24 November 1999 Resolved
Prove proper operation of light fixtures throughout vessel.
Condition: Unknown
Due 7 December 1999
Resolved 7 December 1999
Construction/Loadline
Issued 24 November 1999 Resolved
Properly install stuffing tubes on blkhd penetrations IWO aft E/R blkhd. _x001C_Item to be completed during Jan 2000 drydock in Miami Inspection Zone, per statement from vessel rep/Master [name withheld].
Condition: Unknown
Due 24 November 1999
Resolved 24 November 1999
Engineering
Issued 24 November 1999 Resolved
Provide proper length of exhaust flex hose and double clamps.
Condition: Unknown
Due 7 December 1999
Resolved 7 December 1999
Navigation
Issued 24 November 1999 Resolved
Make permanent and proper repairs to steering ram. Vessel is not to operateuntil steering ram is properly repaired to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 7 December 1999
Resolved 7 December 1999
Electrical
Issued 24 November 1999 Resolved
Provide proper wiring to block heaters.
Condition: Unknown
Due 7 December 1999
Resolved 7 December 1999
Electrical
Issued 24 November 1999 Resolved
Properly repair power wire to bilge high level alarms in E/R.
Condition: Unknown
Due 7 December 1999
Resolved 7 December 1999
Engineering
Issued 2 December 1998 Resolved
Renew forward hose on port side exhaust muffler and double clamp all hoses on exhaust system.
Condition: Unknown
Due 9 December 1998
Resolved 9 December 1998
Electrical
Issued 2 December 1998 Resolved
Provide 1 additional flashlight (2 total).
Condition: Unknown
Due 9 December 1998
Resolved 9 December 1998
Construction/Loadline
Issued 2 December 1998 Resolved
Tighten hull fitting for bilge pump overboard #2 void and double clamp hose.
Condition: Unknown
Due 9 December 1998
Resolved 9 December 1998
Construction/Loadline
Issued 2 December 1998 Resolved
Permanently mount bilge pump and properly affix wiring in #2 void.
Condition: Unknown
Due 9 December 1998
Resolved 9 December 1998
Documentation
Issued 8 December 1997 Resolved
THE VESSEL MUST PROVE IT IS ENROLLED IN A DRUG TESTING PROGRAM.
Condition: Unknown
Due 8 December 1997
Resolved 23 December 1997
Construction/Loadline
Issued 8 December 1997 Resolved
VESSEL MUST PLUG HOLES IN AFT BLKHD.
Condition: Unknown
Due 22 December 1997
Resolved 6 January 1998
Documentation
Issued 8 December 1997 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 22 December 1997
Resolved 23 December 1997
Navigation
Issued 8 December 1997 Resolved
VESSEL MUST HAVE AN ILLUMINATED COMPASS ON BOARD.
Condition: Unknown
Due 22 December 1997
Resolved 23 December 1997
Electrical
Issued 8 December 1997 Resolved
VESSEL MISHING ONE FLASHLIGHT IN THE ENGINE ROOM.
Condition: Unknown
Due 22 December 1997
Resolved 23 December 1997
Navigation
Issued 8 December 1997 Resolved
VESSEL MUST HAVE AN ANCHOR BALL DAYSHAPE ON BOARD
Condition: Unknown
Due 22 December 1997
Resolved 6 January 1998
Lifesaving
Issued 8 December 1997 Resolved
VESSEL IS MISSING A FIRST AID KIT.
Condition: Unknown
Due 22 December 1997
Resolved 23 December 1997
Lifesaving
Issued 8 December 1997 Resolved
VESSEL MUST RETRO REFLECTIVE TAPE AND RESTENCIL ITS NAME ON THE RINGBUOY.
Condition: Unknown
Due 22 December 1997
Resolved 23 December 1997
Engineering
Issued 8 December 1997 Resolved
VESSEL MUST REPAIR PORT EMERGENCY FUEL CUTOFF.
Condition: Unknown
Due 22 December 1997
Resolved 23 December 1997
Construction/Loadline
Issued 8 December 1997 Resolved
VESSEL MUST DOUBLE CLAMP BILGE OVERBOARD IN AFT STEERING.
Condition: Unknown
Due 22 December 1997
Resolved 23 December 1997
Construction/Loadline
Issued 8 December 1997 Resolved
REPAIR OVERBOARD BILGE CONNECTION IN FORWARD COMPARTMENT.
Condition: Unknown
Due 22 December 1997
Resolved 23 December 1997
Documentation
Issued 8 December 1997 Resolved
VESSEL MUST HAVE A COPY OF 46CFR ON BOARD._x001C_
Condition: Unknown
Due 22 December 1997
Resolved 6 January 1998
Electrical
Issued 8 December 1997 Resolved
REMOVE WIRE NUTS ON ENGINE WIRING AND REPLACE WITH COMPRESSION TERMINALS.
Condition: Unknown
Due 22 December 1997
Resolved 23 December 1997
Documentation
Issued 8 December 1997 Resolved
VESSEL MUST HAVE A VALID FCC SAFETY CERTIFICATE ON BOARD.
Condition: Unknown
Due 22 December 1997
Resolved 9 December 1997
Navigation
Issued 15 May 1997 Resolved
MAKE OPERATIONAL MAST LIGHT.
Condition: Unknown
Due 19 May 1997
Resolved 15 May 1997
Unknown
Issued 15 May 1997 Resolved
PROVIDE AND POST VHF BROADCAST PLACARD
Condition: Unknown
Due 19 May 1997
Resolved 15 May 1997
Lifesaving
Issued 15 May 1997 Resolved
INSTALL DRIP PANEL OVER ENGINEROOM LIGHT SWITCH PANEL.
Condition: Unknown
Due 19 May 1997
Resolved 15 May 1997
Construction/Loadline
Issued 25 November 1996 Resolved
Remove old unused bilge piping.
Condition: Unknown
Due 25 November 1996
Resolved 25 November 1996
Electrical
Issued 25 November 1996 Resolved
Remove wire nuts on engine wiring.
Condition: Unknown
Due 25 November 1996
Resolved 25 November 1996
Engineering
Issued 30 November 1995 Resolved
Correct shaft seal leak.
Condition: Unknown
Due 16 December 1995
Resolved 16 December 1995
Navigation
Issued 30 November 1995 Resolved
Repair stern nav light.
Condition: Unknown
Due 16 December 1995
Resolved 16 December 1995
Fire Fighting
Issued 30 November 1995 Resolved
Provide discharge hose for hand portable fire pump.
Condition: Unknown
Due 16 December 1995
Resolved 16 December 1995
Documentation
Issued 30 November 1990 Resolved
PROVIDE FCC LICENSE FOR VHF RADIO.
Condition: Unknown
Due 30 November 1990
Resolved 30 November 1990

Casualty record · 1

20 July 2016Routine · role: Involved in a Marine Casualty · activity 5946719
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.