Records from 1991 to 2025. Most recent: inspection, 20 November 2025.
Inspection history · 93
20 November 2025
COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 8267775
31 October 2025
In-Service Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 8261037
19 August 2025
Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8213451
18 June 2025
Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 8188363
9 January 2025
Administrative Inspection · In-Service Inspection · Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 8056426
22 January 2024
Deficiency Check · Administrative Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7853050
8 January 2024
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7846274
15 November 2023
Administrative Inspection · Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7825242
15 August 2023
Examination of Repairs · Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7762687
10 February 2023
Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7635011
9 January 2023
Annual Inspection · Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7618080
8 February 2022
Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7392502
10 January 2022
Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7376367
18 August 2021
Drydock Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7281516
14 January 2021
COI Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7124360
20 February 2020
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6927298
26 August 2019
Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6795418
10 January 2019
DAPI Audit · Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6607737
12 January 2018
Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6336790
12 January 2018
Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6336816
26 October 2017
Examination of Repairs · Drydock Exam · Administrative Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6295055
9 October 2017
Internal Structural Exam · In-Service Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6296633
5 January 2017
Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6083972
23 December 2015
DAPI Audit · COI Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 5786250
4 November 2015
Drydock Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 5758522
4 November 2015
Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 5777233
22 October 2014
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 5010002
26 August 2014
Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 4972428
25 July 2012
Administrative Inspection · Deadweight Survey · Deficiency Check · COI Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 4390084
2 February 2011
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3957150
13 January 2010
Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3663054
28 January 2009
Internal Structural Exam · Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3402710
1 July 2008
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3295554
26 October 2007
COI Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3087382
24 July 2007
Hull Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3006664
8 February 2007
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2868986
16 May 2006
Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2650790
29 August 2005
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2478243
9 August 2005
Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2456775
18 April 2005
Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2336697
14 April 2005
COI Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2333154
8 April 2005
Hull Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2329102
27 February 2005
Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2373707
18 February 2005
MTSA/ISPS Verification
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2295021
10 January 2005
Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2271707
7 June 2004
Administrative Inspection
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2091487
21 April 2004
Administrative Inspection
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2049187
12 April 2004
Hull Examination · COI Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2042805
6 March 2004
Administrative Inspection
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2019434
8 January 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1980633
21 May 2003
Hull Examination · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1798831
27 December 2001
Re-Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1484313
23 January 2001
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1415538
29 October 2000
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1062029
22 December 1999
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 148036
30 October 1999
COI Inspection · Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1436317
4 December 1998
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1409989
3 November 1998
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1372408
21 October 1998
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1462692
27 August 1998
Drydock Extension
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1364844
11 August 1998
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 796105
1 July 1998
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 794295
5 November 1997
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1400662
5 November 1997
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1400663
1 October 1997
Examination of Repairs
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1427413
11 August 1997
Hull Examination · Drydock Extension
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 783180
29 May 1997
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1111164
11 October 1996
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1462530
26 August 1996
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1425784
12 April 1996
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1080739
4 December 1995
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 871890
14 November 1995
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 873115
22 October 1995
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1465221
21 August 1995
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1465837
14 October 1994
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1424011
26 September 1994
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1434169
26 August 1994
Excursion Permit
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1175205
22 August 1994
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 871109
10 August 1994
Excursion Permit
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1177914
3 May 1994
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 674629
23 April 1994
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 468175
15 April 1994
COI Inspection · Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1370832
21 March 1994
Deadweight Survey
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1166227
18 January 1994
Excursion Permit
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1161852
23 August 1993
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1156807
26 April 1993
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1389643
30 March 1993
Excursion Permit
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 840931
29 September 1992
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1259935
2 September 1992
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1134252
29 April 1992
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1269815
7 January 1992
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 949016
1 May 1991
Initial Certification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1221921
10 April 1991
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 937689
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 20 November 2025
Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each normally unmanned space. The vessel has one port and one starboard bilge high level alarm for three separate spaces in each hull.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 December 2025
Resolved 23 December 2025
Resolution: New bilge high level alarm panels have been installed and MI witnessed a satisfactory test of the system.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 November 2025
Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. Beginning with the January 2025 annual inspection, an annual rigging survey is required, paying special attention to the condition of the stainless steel wires and their terminals. The surveyor noted items in need of repair or replacement.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 December 2025
Resolved 23 December 2025
Resolution: All requirements from the rigging survey have been completed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 November 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards including fire, caused by or originating in electrical equipment, and electrical shock. Open ended wiring was noted at the operating station, port side.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 December 2025
Resolved 4 December 2025
Resolution: All noted dead end wiring has been removed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 November 2025
Resolved
A vessel must carry one floating waterlight, unless it is limited to daytime operation, in which case no floating waterlight is required. The floating waterlight was found to be inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 December 2025
Resolved 26 November 2025
Resolution: A new floating water light has been purchased and fitted with the ring buoy.
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 20 November 2025
Resolved
A vessel must be fitted with ground tackle and mooring lines necessary for the vessel to be safely anchored or moored. Excessive rust was noted on the forward anchor and chain.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 December 2025
Resolved 10 December 2025
Resolution: The vessel's forward anchor has been replaced.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 17 January 2025
Resolved
Except on a vessel limited to daytime operations, the
compass must be illuminated. The vessel crew could not
prove compass illumination.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 January 2025
Resolved 14 February 2025
Resolution: The new compass was installed and can be illuminated.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 17 January 2025
Resolved
A vessel must carry adequate and up-to-date U.S. Coast Pilot or similar publication, Coast Guard Light List, and tide tables. U.S. Coast Pilot was not maintained on board and the Coast Guard Light List and tide tables were found to be outdated.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 January 2025
Resolved 23 January 2025
Resolution: The captain provided a photo of publications added to the vessel.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 17 January 2025
Resolved
A marine employer shall comply with the requirements of 46 CFR 4.06. The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in a Serious Marine Incident. The vessel could not produce alcohol testing devices for all crewmembers serving on board.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 January 2025
Resolved 5 February 2025
Resolution: The vessel maintains an adequate number of alcohol test strips and Danielle has been added to the covered crew list.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 January 2024
Resolved
The minimum number of portable fire extinguishers required on a vessel must be acceptable to the OCMI, but not fewer than the minimum number required by table 181.500(b). Vessel needs to replace 01 fire extinguisher.
Action required: 17 - Rectify deficiencies prior to departure
Due 9 January 2024
Resolved 9 January 2024
Resolution: Vessel captain has purchased new fire extinguisher with new paperwork.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 January 2024
Resolved
The connections in a cable splice must be compatible with all other material in the splice and with the materials in the splice. Repair electrical connections behind the fuse panel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 February 2024
Resolved 22 January 2024
Resolution: Received photo documentation that the wiring is now correctly spliced.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 January 2024
Resolved
Vessel needs to reinstall the forestay pin spacer in forestay.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 February 2024
Resolved 22 January 2024
Resolution: Received photo documentation that the forestay spacer has been reinserted in to its proper location.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 15 August 2023
Resolved
*For longitudinal framing support structures (stringers) in both port & starboard sides :
Multiple longitudinal framing support inner hull structures (stringers) have been found with dry wood decay exposing its fibers and losing support and strength. Stringers are to be sanded until good wood has been found and inspected by an attending USCG Marine Inspector. Stringers found with superficial dry decay-shall be treated with a wood preserver as recommended in wood repair NVIC 7-95. Stringers found to have excessive wastage (over 25%) shall be verified by an attending USCG Marine Inspector after sanding; and a repair proposal shall be submitted to address the replacement in kind those found with excessive wastage.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 November 2023
Resolved 15 November 2023
Resolution: Converted to CG-835. Inspected stringers they have been sanded down to good wood and treated with a wood perserver.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 15 August 2023
Resolved
Provide a recent sail and rigging survey report, including the sail vessel dimensions. Sail and Rigging survey report shall include the information as displayed in the USCG NVIC 02-16, appendix 3, enclosure 1.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 November 2023
Resolved 2 November 2023
Resolution: Converted to CG-835. Received Sail Rigging Report.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 15 August 2023
Resolved
All port and starboard deck hatch covers have been found with wood decay by separation of the wood fibers in their frames and without means of keep close the hatches. Provide a repair proposal to repair or replace, also to include hatch closing devices.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 November 2023
Resolved 15 November 2023
Resolution: Converted to CG-835. Hatches have been repaired and closing devices have been included on hatches.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 August 2023
Resolved
(a) Port Hull, galley forward outboard side, bottom two stringers, scrape clean of all decay material and clear to good wood, treat with a wood preservative solution.
(b) Port Hull, galley from aft bulkhead to first ring frame forward, inboard side, tow bottom stringer, scrape clear of all decay material to good wood, treat with wood preservative solution.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 November 2023
Resolved 15 November 2023
Resolution: Stringers have been sanded down to good wood and treated with a wood perserver.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 January 2023
Resolved
An adult life jacket must be provided for each person carried on board a vessel. (01) Adult life jackets have been found to be in a dilapidated state and not fit for service. Until replaced vessel is only allowed 51 adults on board.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 February 2023
Resolved 8 February 2023
Resolution: Received photo documentation of the newly purchased life jacket.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 9 January 2023
Resolved
A vessel must comply with the applicable requirements for a station license and installation certificates to be issued by the FCC as set forth in 47 CFR part 80. Vessel is required to have a crew member with a valid FFC operators license.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 February 2023
Resolved 8 February 2023
Resolution: Received photo documentation of document.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 9 January 2023
Resolved
Any vessel of at least 5 net tons which engages in the Exclusive economic zone, must have a Certificate of Documentation bearing valid endorsement appropriate for the activity in which engaged.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 February 2023
Resolved 10 March 2023
Resolution: Received photo documentation of the paper work which has been submitted to MSC.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 9 January 2023
Resolved
Appropriate for the intended voyage, a vessel must carry adequate and up to date charts and publications. Vessel is missing current tides and current tables.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 February 2023
Resolved 8 February 2023
Resolution: Received photo documentation of the updated and missing tides and currents paperwork.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 9 January 2023
Resolved
Unless otherwise specified, vessel owners must pay the fees required before inspection services are provided. Provide documentation of payment to www.pay.gov.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 February 2023
Resolved 8 February 2023
Resolution: Received photo document of user fees which have been paid.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 January 2022
Resolved
An adult life jacket must be provided for each person carried on board a vessel. Adult life jackets have been found to be in a dilapidated state and not fit for service. Until replaced vessel is only allowed 41 passengers and 03 crew on board.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 February 2022
Resolved 8 February 2022
Resolution: Received photo documentation that the vessel received it's new life jackets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 January 2021
Resolved
Child sized lifejackets need retroreflective tape re-newed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 January 2021
Resolved 21 January 2021
Resolution: New tape has been applied, via pictures.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 January 2021
Resolved
Donning plackard required for each manufacture of jacked.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 January 2021
Resolved 21 January 2021
Resolution: Donning plackard posted, via pictures.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 14 January 2021
Resolved
Port hull FWD bulkhead not sealed.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 January 2021
Resolved 21 January 2021
Resolution: Man hole bolted pack in place, via pictures.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 January 2021
Resolved
Several dead end wires in the port hull need to be removed or tagged OOC.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 January 2021
Resolved 21 January 2021
Resolution: Wires and unused fan removed, via pictures.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 20 February 2020
Resolved
Vessel does not have current state registration.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 March 2020
Resolved 15 January 2021
Resolution: Vessel has a current VI registration.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 20 February 2020
Resolved
Portable fire extinguishers have not been annually serviced.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 March 2020
Resolved 20 February 2020
Resolution: Fire extinguishers serviced.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 20 February 2020
Resolved
Vessels life floats need servicing/repair/replacement or the vessel will be restricted to no more than 3nm.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 March 2020
Resolved 4 May 2020
Resolution: Vessel removed life floats and is restricted to no more than 3nm. Updated COI
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 20 February 2020
Resolved
Vessel's EPIRB hydrostatic release expired.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 March 2020
Resolved 24 March 2020
Resolution: Replaced hydrostatic release with new one.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 February 2020
Resolved
Vessel's mainsail boom requires a new gooseneck pin. Vessel is restricted from using mainsail until pin is replaced and satisfactorily inspected by attending MI.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 March 2020
Resolved 4 May 2020
Resolution: Replaced pin on 24 MAR 2020 and was inspected satisfactory by MI on 4 MAY 2020
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 20 February 2020
Resolved
As the use of the mainsail is restricted, drills were deferred until mainsail goosneck pin is replaced.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 March 2020
Resolved 4 May 2020
Resolution: Drills conducted satifactorily.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 20 February 2020
Resolved
Vessel is required to provide a copy of the Preventative Maintenance Plan for sails and rigging and all associated logs. Copy was not on board at time of inspection.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 March 2020
Resolved 24 March 2020
Resolution: Vessel operator provided PMP and associated logs.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 10 January 2019
Resolved
Vessel does not have valid COD nor valid State registration.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 February 2019
Resolved 19 July 2019
Resolution: Vessel has current VI registration.
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 10 January 2019
Resolved
EPIRB registration sticker expired on EPIRB. (Vessel has current paper registration.)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 February 2019
Resolved 22 July 2019
Resolution: Vessel has current registration. Expiration 12JAN2020.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 January 2019
Resolved
Placed eight (08) ADULT and two (02) CHILD PFD's out of service. Vessel restricted in passenger count until replacement.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 February 2019
Resolved 22 July 2019
Resolution: Vessel has bought new life jackets and marked them appropriately.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 January 2019
Resolved
Vessel has new life ring that is not properly marked.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 February 2019
Resolved 22 July 2019
Resolution: Life ring properly marked.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 10 January 2019
Resolved
First aid kit had missing and expired items.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 February 2019
Resolved 22 July 2019
Resolution: Replaced missing/expired items.
Electrical › Electric Supply System (service) › Cable
Issued 27 December 2017
Resolved
The wiring for the forward running lights is not marine grade cable and must be replaced with marine grade cable.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 January 2018
Resolved 22 July 2019
Electrical › Electric Supply System (service) › Cable
Issued 27 December 2017
Resolved
Removed unused and dead ended wiring.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 January 2018
Resolved 22 July 2019
Electrical › Lighting (service) › Lighting Fixture
Issued 27 December 2017
Resolved
Replace multiple broken light fixtures.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 January 2018
Resolved 22 July 2019
Stability › Watertight Integrity › General
Issued 27 December 2017
Resolved
Repair broken hinge on STBD aft hatch
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 January 2018
Resolved 22 July 2019
Lifesaving › Hand Flares › Expired
Issued 27 December 2017
Resolved
Provide proper number of hand flares. The vessel had all expired hand flares onboard.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 December 2017
Resolution: Owner sent photo with the proper number of new flares they had purchased for the vessel before departing for St Croix.
Engineering › Steering Gear System › Rudder
Issued 26 October 2017
Resolved
Remove rudders on port and stbd side and inspect packing. Too much play when pressure applied to rudder.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 27 December 2017
Resolution: Port and STBD Rudders removed and replaced with all parts installed.
Construction/Loadline › Hull › Hull Plating
Issued 26 October 2017
Resolved
Replace rotten wood around the port galley window
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 27 December 2017
Resolution: Port and STBD windows were replaced and rotten framing replaced with good wood.
Construction/Loadline › Hull › Hull Plating
Issued 26 October 2017
Resolved
Replace rotten wood on the port galley deck
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 27 December 2017
Resolution: Rotten wood was removed and replaced with high density filler and glassed with 1708 matt back biaxial cloth using west system epoxy.
Construction/Loadline › Penetrations › Pipe Flange
Issued 26 October 2017
Resolved
Refurbish or replace the sink drain throughull on port side
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 27 December 2017
Resolution: The throughhull valve was cleaned and reworked, but determined to not be used so was closed and the handle removed.
Construction/Loadline › Hull › Transverse Frame
Issued 26 October 2017
Resolved
Replace inspection port cover on the port side
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 22 July 2019
Lifesaving › Inflatable Buoyant Apparatus › Weak Link
Issued 5 January 2017
Resolved
Replace weak links (2) to proper vessel capacity prior to sailing beyond 3 NM.
Action required: 705 - Other - as specified
Due 19 January 2017
Resolved 12 January 2018
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 5 January 2017
Resolved
Properly mount all Fire extinguishers (4).
Action required: 705 - Other - as specified
Due 12 January 2017
Resolved 12 January 2018
Lifesaving › Inflatable Buoyant Apparatus › Stowage
Issued 5 January 2017
Resolved
Add spacer.
Action required: 705 - Other - as specified
Due 19 January 2017
Resolved 12 January 2018
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 8 January 2016
Resolved
Provide updated Safety Radio Cert. New owner info required.
Action required: 705 - Other - as specified
Due 8 February 2016
Resolved 3 March 2016
Resolution: Safety Radio Cert. provided
Navigation › Piloting/Steering › Magnetic Compass
Issued 8 January 2016
Resolved
Prove operation of magnetic compass.
Action required: 705 - Other - as specified
Due 8 February 2016
Resolved 3 March 2016
Resolution: Magnetic compass operational.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 8 January 2016
Resolved
Provide operational lifering buoy light.
Action required: 705 - Other - as specified
Due 8 February 2016
Resolved 3 March 2016
Resolution: Lifering buoy light operational.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 23 December 2015
Resolved
Provide retro-refelctive tape on ring buoy.
Action required: 705 - Other - as specified
Due 8 February 2016
Resolved 3 March 2016
Resolution: Retro-reflective tape on ring buoy.
Documentation › Safety Management System › Key Shipboard Operations Plans/Instructions
Issued 23 December 2015
Resolved
Provide vessel sail plan and keep nboard vessel.
Action required: 705 - Other - as specified
Due 8 February 2016
Resolved 3 March 2016
Resolution: Sail plan provided.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 4 November 2015
Resolved
Port side bilge water alarm visual indicator is inoperable.
Action required: 705 - Other - as specified
Due 4 December 2015
Resolved 8 December 2015
Resolution: Bilge alarms replaced.
Stability › Watertight Integrity › General
Issued 4 November 2015
Resolved
Make repair to portside waste fitting and deck at drydock
Action required: 705 - Other - as specified
Due 4 December 2015
Resolved 8 December 2015
Resolution: Portside fitting removed and deck repaired.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 4 November 2015
Resolved
Deck rail aft on both sides need to be able to hold 200lbs. Rails very weak.
Action required: 705 - Other - as specified
Due 30 December 2015
Resolved 8 December 2015
Resolution: Deck rail strenght added by using larger washers and 5200.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 26 August 2014
Resolved
Provide valid FCC Safety Radio Certificate
Action required: 705 - Other - as specified
Due 28 September 2014
Resolved 20 November 2014
Resolution: FCC conducted exam and issued new document.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 26 August 2014
Resolved
Log monthly drills and EPIRB test.
Action required: 705 - Other - as specified
Due 28 August 2014
Resolved 28 August 2014
Resolution: EPIRB logged.
Navigation › Piloting/Steering › Magnetic Compass
Issued 26 August 2014
Resolved
Provide light for magnetic compass.
Action required: 705 - Other - as specified
Due 28 September 2014
Resolved 20 November 2014
Resolution: New light installed.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 26 August 2014
Resolved
Stow child lifejackets in seperate location from ault life jackets.
Action required: 705 - Other - as specified
Due 28 September 2014
Resolved 20 November 2014
Resolution: Child lifejackets moved to there own location and stowage was labeled.
Navigation › Piloting/Steering › Marine Charts
Issued 26 August 2014
Resolved
Provide current chart.
Action required: 705 - Other - as specified
Due 28 September 2014
Resolved 20 November 2014
Resolution: Current local chart provided.
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 August 2014
Resolved
Provide cap's for deadend electrical wires behind switchboard.
Action required: 705 - Other - as specified
Due 28 September 2014
Resolved 20 November 2014
Resolution: Dead end wires capped.
Operations/Management › Drills/Instruction › Not Conducted
Issued 26 August 2014
Resolved
Get underway for drills and seaworthyness.
Action required: 705 - Other - as specified
Due 26 September 2014
Resolved 20 November 2014
Resolution: Got underway for fire and man overboard drills and tested sails, engine and steering.
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 26 August 2014
Resolved
Pre-employment drug test not completed for deckhand.
Action required: 705 - Other - as specified
Due 26 September 2014
Resolved 3 September 2014
Resolution: Pre-employment test verified completed on September 3rd.
Engineering › Gasoline Engine (propulsion) › Combustion Chamber (2 stroke)
Issued 20 September 2012
Resolved
While enroute to berth, outboard engine loss propulsion. This is the third occurance of this propulsion failure of this vessel. Provide technical report describing cause of failure and permanent repairs made.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 September 2012
Resolved 1 December 2012
Resolution: Received phone call from St. Croix Marine lead mechanic, Casey Carr explaining that the throttle body plates had stuck. After overhaul, engine operated as designed.
Fire Fighting › Portable CO2 Fire Extinguisher › Pressure Gauge
Issued 20 September 2012
Resolved
Piloting station portable fire extinguisher pressure gauge indicates an undercharged condition. Provide a servicable fire extinguisher at the piloting station.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 September 2012
Resolved 19 November 2012
Resolution: Boat Forces St. Croix boarded vessel underway and verified portable fire extinguisher was fully charged.
Communications › Radio Communications › EPIRB
Issued 7 August 2012
Resolved
EPIRB hydrostatic release expired in August 2011. Provide valid HRU for EPIRB. Vessel is restricted to within 3 miles of shore until replaced.
Action required: 705 - Other - as specified
Due 21 August 2012
Resolved 13 August 2012
Resolution: Witnessed valid hydrostatic release unit for EPIRB with expiration date of August 2014.
Lifesaving › Lifejacket/PFD (Type III) › Storage
Issued 7 August 2012
Resolved
Child size PFD's found mixed in with adult sized PFD's. Separate child size PFD's and label new location with number.
Action required: 705 - Other - as specified
Due 21 August 2012
Resolved 4 September 2012
Resolution: Child sized PFD''s were separated from adult and location labeled with number.
Engineering › Bilge Water Management System › Not Installed
Issued 7 August 2012
Resolved
Port aft high water alarm sensor found unbolted and loose. Mount port aft high water alarm sensor.
Action required: 705 - Other - as specified
Due 21 August 2012
Resolved 4 September 2012
Resolution: Port aft high water alarm sensor mounted correctly.
Engineering › Bilge Water Management System › Not Operational
Issued 7 August 2012
Resolved
Prove proper operation of port midship forward bilge high level sensor. Sensor is currently not functioning.
Action required: 705 - Other - as specified
Due 21 August 2012
Resolved 4 September 2012
Resolution: Proper operation was proved of port midship forward bilge high level sensor.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 7 August 2012
Resolved
Remove or make safe 110 volt electrical appliances and outlets port and stbd side (outlets, light fixtures, etc).
Action required: 705 - Other - as specified
Due 21 August 2012
Resolved 4 September 2012
Resolution: Unsafe fixtures were removed. Electrical outlets were made safe.
Engineering › Bilge Water Management System › Strainer
Issued 7 August 2012
Resolved
Strainer missing on port aft bilge suction line. Provide suction strainer on port aft bilge suction line.
Action required: 705 - Other - as specified
Due 21 August 2012
Resolved 4 September 2012
Resolution: Strainer installed on port aft bilge suction line.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 7 August 2012
Resolved
Several leaking substances were identified in the starboard forward hull. Remove leaking hazardous material onboard.
Action required: 705 - Other - as specified
Due 21 August 2012
Resolved 4 September 2012
Resolution: Hazardous material was removed and cleaned.
Electrical › Electrical Distribution System (service) › Cable
Issued 7 August 2012
Resolved
Multiple "dead-end" wires found throughout vessel. Remove dead end wiring throughout vessel.
Action required: 705 - Other - as specified
Due 21 August 2012
Resolved 4 September 2012
Resolution: Dead-end wiring was removed.
Engineering › Bilge Water Management System › Interface Detector
Issued 7 August 2012
Resolved
Port mid-aft high level sensor found loose. Mount port mid-aft high level sensor.
Action required: 705 - Other - as specified
Due 21 August 2012
Resolved 4 September 2012
Resolution: Port mid-aft high level sensor mounted properly.
Engineering › Bilge Water Management System › Piping
Issued 7 August 2012
Resolved
Permanently seal around bilge piping in port hull.
Action required: 705 - Other - as specified
Due 21 August 2012
Resolved 4 September 2012
Resolution: Bilge piping in port hull sealed with spray foam.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 7 August 2012
Resolved
Water light did not funtion as designed. Provide operational automatically operating water light for life-float.
Action required: 705 - Other - as specified
Due 21 August 2012
Resolved 4 September 2012
Resolution: New battery was installed. Water light tested and operated satisfactory.
Construction/Loadline › Penetrations › Gasket
Issued 7 August 2012
Resolved
Gasket missing on forward ventilation cover. Provide o-ring/gasket to make water-tight.
Action required: 705 - Other - as specified
Due 21 August 2012
Resolved 4 September 2012
Resolution: New o-ring gasket provided for ventilation cover.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 7 August 2012
Resolved
Ring life buoy missing retro-reflective tape. Provide adequate amount of retro-reflective tape.
Action required: 705 - Other - as specified
Due 21 August 2012
Resolved 13 August 2012
Resolution: Witnessed proper quantity of retro-reflective tape affixed to ring life buoy.
Sail Rigging › Chainplates › Fasteners
Issued 7 August 2012
Resolved
Missing bolt located on mid baby-stay. It appeared to have been sheared off. Replace missing bolt on center line baby stay.
Action required: 705 - Other - as specified
Due 21 August 2012
Resolved 4 September 2012
Resolution: Missing bolt replaced.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 7 August 2012
Resolved
Two portable fire extinguisher brackets are broken or unserviceable. Replace fire extinguisher brackets at steering station and navigation station.
Action required: 705 - Other - as specified
Due 21 August 2012
Resolved 4 September 2012
Resolution: Replacement fire extinguisher brackets were bolted to steering station and navigation station.
Engineering › Steering Gear System › Hydraulic Hose
Issued 7 August 2012
Resolved
Hydraulic hose for steering gear hydraulic ram found kinked. Repair or replace outboard steering ram hydraulic hoses.
Action required: 705 - Other - as specified
Due 21 August 2012
Resolved 4 September 2012
Resolution: Hose was shortened beyond kink and new fitting was installed. Steering check sat.
Operations/Management › Drills/Instruction › Safety Orientation
Issued 7 August 2012
Resolved
Emergency instructions are not posted. Post emergency instructions.
Action required: 705 - Other - as specified
Due 21 August 2012
Resolved 4 September 2012
Resolution: Emergency instructions have been posted.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 7 August 2012
Resolved
Provide corrected charts onboard.
Action required: 705 - Other - as specified
Due 21 August 2012
Resolved 4 September 2012
Resolution: Corrections were provided for charts.
Engineering › Bilge Water Management System › Pump
Issued 7 August 2012
Resolved
Portable bilge pump missing. Provide portable bilge pump.
Action required: 705 - Other - as specified
Due 21 August 2012
Resolved 4 September 2012
Resolution: Portable bilge pump provided onboard stecilled with the name "Jolly Mon"
Stability › Incline Test › General
Issued 7 August 2012
Resolved
New mast installed. Prove proper stability of vessel with new mast by conducting a deadweight survey with an attending Marine Inspector.
Action required: 705 - Other - as specified
Due 7 September 2012
Resolved 14 January 2013
Resolution: new stability letter issued, 49 passengers, 3 crew, total 52 persons.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 7 August 2012
Resolved
Install blank on breaker panel in accommodation space.
Action required: 705 - Other - as specified
Due 21 August 2012
Resolved 4 September 2012
Resolution: Blank installed in breaker panel in accommodation space.
Construction/Loadline › Hull › Hull Plating
Issued 7 August 2012
Resolved
A hole in the hull was discovered forward of the collision bulkhead on port hull. Effect repairs of waterfight integrity of port hull forward crash compartment inboard side.
Action required: 705 - Other - as specified
Due 21 August 2012
Resolved 4 September 2012
Resolution: Repairs were made on the hole in the hull.
Documentation › Safety/Response Plans/Programs › General Arrangement Plans
Issued 7 August 2012
Resolved
Provide Rigging maintenance plan in accordance with SSJ instruction provided to owner.
Action required: 705 - Other - as specified
Due 7 September 2012
Resolved 15 April 2013
Resolution: Approved rigging plan submitted.
Sail Rigging › Running Rigging › Shackles
Issued 7 August 2012
Resolved
Main sheet car shackle found wasted approx. 50%. Replace main sheet car shackle prior to passenger operations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 August 2012
Resolution: Replacement shackle of a larger sized installed on main sheet car shackle. Shackle orifice machined to diameter of car and witnessed moving freely. All Sat.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 13 January 2010
Resolved
Label vessel name and hailing port on stern.
Due 20 January 2010
Resolved 3 May 2010
Lifesaving › Lifefloat › Paddle
Issued 13 January 2010
Resolved
Provide one paddle for lifefloat.
Due 20 January 2010
Resolved 15 February 2010
Fire Fighting › Fire Bucket › Quantity
Issued 13 January 2010
Resolved
Provide one fire bucket.
Due 20 January 2010
Resolved 15 March 2010
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 13 January 2010
Resolved
Service both BII fire extinguishers.
Due 20 January 2010
Resolved 15 January 2010
Engineering › Bilge Water Management System › Piping
Issued 13 January 2010
Resolved
Repair several bilge piping cracks throughout vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 January 2010
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 28 January 2009
Resolved
Stencil lifering with vessel name.
Action required: 705 - Other - as specified
Due 29 January 2009
Resolved 9 July 2009
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 28 January 2009
Resolved
Provide valid FCC safety equipment certificate.
Action required: 705 - Other - as specified
Resolved 9 July 2009
Engineering › Bilge Water Management System › Interface Detector
Issued 28 January 2009
Resolved
Provide operational bilge alarma light stbd hull
Action required: 705 - Other - as specified
Resolved 9 July 2009
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 28 January 2009
Resolved
Post lifejacket donning placard.
Action required: 705 - Other - as specified
Due 29 January 2009
Resolved 9 July 2009
Fire Fighting › Fire Bucket › Stenciling
Issued 28 January 2009
Resolved
Stencil and provide permanent line for 3 fire buckets.
Action required: 705 - Other - as specified
Due 29 January 2009
Resolved 9 July 2009
Navigation › Piloting/Steering › Coast Guard Light List
Issued 28 January 2009
Resolved
Provide US coast pilot, coast guard light list, tide tables for geographical area of vessel.
Action required: 705 - Other - as specified
Due 29 January 2009
Resolved 9 July 2009
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 28 January 2009
Resolved
Segregate child lifejackets from adults.
Action required: 705 - Other - as specified
Due 29 January 2009
Resolved 9 July 2009
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 26 October 2007
Resolved
Found two of the port hull high bilge level alarms inoperative. Prove proper operation of all high level alarms
Action required: 705 - Other - as specified
Resolved 31 October 2007
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 26 October 2007
Resolved
Properly label all breakers in breaker panel.
Action required: 705 - Other - as specified
Resolved 31 October 2007
Communications › Radio Communications › VHF Radiotelephone
Issued 26 October 2007
Resolved
Vessel radio found to be inoperative. Prove proper operation of VHF radio.
Action required: 705 - Other - as specified
Resolved 31 October 2007
Lifesaving › Hand Flares › Expired
Issued 26 October 2007
Resolved
All visual distress signals expired. Provide required visual distress signals for vessel.
Action required: 705 - Other - as specified
Resolved 31 October 2007
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 26 October 2007
Resolved
19 lifejackets rejected for deteriorated retro. Provide 45 servicable adult life jackets IAW COI
Action required: 705 - Other - as specified
Resolved 31 October 2007
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 26 October 2007
Resolved
Examined 8 children's lifejackets, rejected 7. Provide 5 serviceable children's life jackets IAW COI.
Action required: 705 - Other - as specified
Resolved 31 October 2007
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 26 October 2007
Resolved
Mark and provide retro tape on life ring IAW 46 CFR 185.604
Action required: 705 - Other - as specified
Resolved 1 November 2007
Lifesaving › Lifefloat › Serviceable
Issued 26 October 2007
Resolved
Found all 3 lifefloats in disrepair. All 3 bottom net cages are broken. Found 1 paddle broken. Found the outer skin on 1 damaged and susceptible to water intrusion. Provide 3 acceptable life floats.
Action required: 705 - Other - as specified
Resolved 31 October 2007
Fire Fighting › Portable CO2 Fire Extinguisher › Number
Issued 26 October 2007
Resolved
Provide all portable fire extinguishers IAW COI.
Action required: 705 - Other - as specified
Resolved 31 October 2007
Communications › Radio Communications › EPIRB
Issued 26 October 2007
Resolved
Affix registration sticker to EPIRB
Action required: 705 - Other - as specified
Resolved 1 November 2007
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 26 October 2007
Resolved
Provide all required navigation pubs IAW 46 CFR 184.420
Action required: 705 - Other - as specified
Resolved 1 November 2007
Construction/Loadline › Structures › Deck Plating
Issued 24 July 2007
Resolved
RENEW ROTTED WOOD PORT AND STBD AFT COMPARTMENT VENTS
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 July 2007
Resolved 24 September 2007
Construction/Loadline › Hull › Side Shell
Issued 24 July 2007
Resolved
RENEW ROTTED WOOD STBD SIDE OUTBOARD HULL AMIDSHIPS
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 July 2007
Resolved 24 September 2007
Engineering › Steering Gear System › Rudder
Issued 24 July 2007
Resolved
REPAIR PORT AND STBD RUDDERS
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 July 2007
Resolved 24 September 2007
Construction/Loadline › Structures › Deck Plating
Issued 24 July 2007
Resolved
REPAIR ROTTEN WOOD AT STBD SIDE DECK RAIL MOUNTS
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 July 2007
Resolved 24 September 2007
Construction/Loadline › Structures › Deck Plating
Issued 24 July 2007
Resolved
REPAIR ROTTED WOOD AT PORT SIDE DECK RAIL MOUNTS
Due 24 July 2007
Resolved 24 September 2007
Construction/Loadline › Structures › Manhole
Issued 24 July 2007
Resolved
REPLACE 3 FWD DECK HATCHES AS DESIGNATED.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 July 2007
Resolved 24 September 2007
Construction/Loadline › Structures › Superstructure
Issued 24 July 2007
Resolved
REPAIR ROTTED WOOD IN COACH ROOF FWD AND STBD SIDES
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 July 2007
Resolved 24 September 2007
Deck/Cargo › Mooring/Anchoring › Anchor Cable
Issued 24 July 2007
Resolved
RENEW OR REMOVE STBD SIDE HF RADIO INSULATOR FROM BACKSTAY
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 July 2007
Resolved 1 November 2007
Resolution: Verified insulator has been removed
Construction/Loadline › Structures › Transverse Bulkhead
Issued 24 July 2007
Resolved
MAKE COLLISION BULKHEADS WATERTIGHT AS PER APPROVED CONSTRUCTION PLANS
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 July 2007
Resolved 24 September 2007
Personnel › Training › Crisis Management/Human Behaviour
Issued 18 April 2005
Resolved
PRIOR TO AN INTERNATIONAL VOYAGE, PROVIDE PROOF OF ALL CREW COMPLETION OF STCW CROWD CONTROL AND MASTER'S COMPLETION OF STCW CRISIS MANAGEMENT AND HUMAN BEHAVIOR.
Action required: 705 - Other - as specified
Due 29 April 2005
Resolved 27 May 2005
Lifesaving › Lifebuoys › Stowage
Issued 18 April 2005
Resolved
MAKE BOUYANT APPARATUS STOWAGE ARRANGEMENT AS PER 46 CFR 180.137.
Action required: 705 - Other - as specified
Due 29 April 2005
Resolved 27 May 2005
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 18 April 2005
Resolved
PROVIDE LOCKING DEVICE FOR ALL SHACKLES ON BOARD.
Action required: 705 - Other - as specified
Due 29 April 2005
Resolved 27 May 2005
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 18 April 2005
Resolved
HARD SPLICE ALL LANYARDS FOR BUOYANT APPARTUS WATERLIGHTS AND RING BUOY WATERLIGHT, AS SHOWN.
Action required: 705 - Other - as specified
Due 29 April 2005
Resolved 27 May 2005
Operations/Management › Drills/Instruction › Not Conducted
Issued 14 April 2005
Resolved
Complete emergency drills
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 April 2005
Engineering › Gasoline Engine (propulsion) › Fuel Intake (2 stroke)
Issued 14 April 2005
Resolved
Complete emergency drills.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 April 2005
Engineering › Steering Gear System › Rudder
Issued 8 April 2005
Resolved
PRIOR TO REFLOATING VESSEL, MAKE PERMANENT REPAIRS TO PORT RUDDER, IN WAY OF LOWER ONE-THIRD (1/3), DUE TO WET ROT, AS SHOWN.
Action required: 705 - Other - as specified
Due 8 April 2005
Resolved 18 April 2005
Engineering › Steering Gear System › Rudder
Issued 8 April 2005
Resolved
PRIOR TO REFLOATING VESSEL, MAKE PERMANENT REPAIRS TO STARBOARD RUDDER, IN WAY OF UPPER LEADING AND TRAILING EDGES, AS SHOWN.
Action required: 705 - Other - as specified
Due 8 April 2005
Resolved 18 April 2005
Engineering › Steering Gear System › Linkage
Issued 8 April 2005
Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE AND INSTALL LOCKING DEVICE FOR RUDDER TILLER ARM RIGGING SHACKLES, AS SHOWN.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 April 2005
Resolved 18 April 2005
Construction/Loadline › Structures › Plowshare Breakwater
Issued 8 April 2005
Resolved
PRIOR TO CARRYING PASSENGERS, REBUILD OUTBOARD MOTOR SLED IN ITS ENTIRETY, AS REQUIRED.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 April 2005
Resolved 18 April 2005
Construction/Loadline › Structures › Deck Plating
Issued 8 April 2005
Resolved
PRIOR TO CARRYING PASSENGERS, ARREST FRACTURES IN LIFEFLOAT SUPPORT MEMBERS AND PROVIDE ADDITIONAL METAL SUPPORTS, AS REQUIRED.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 April 2005
Resolved 18 April 2005
Deck/Cargo › Holds/Tanks › Independent Tank
Issued 8 April 2005
Resolved
PRIOR TO CARRYING PASSENGERS, MAKE PERMANENT REPAIRS TO PORT AND STARBOARD INDEPENDENT FUEL TANK FITTINGS AND HOSES, AS REQUIRED.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 April 2005
Resolved 18 April 2005
Personnel › Training › Crisis Management/Human Behaviour
Issued 18 February 2005
Resolved
PRIOR TO INTERNATIONAL VOYAGE, PROVIDE PROOF OF ALL MASTER'S COMPLETION OF STCW CRISIS MANAGEMENT/HUMAN BEHAVIOR AND CROWD CONTROL
Action required: 705 - Other - as specified
Due 18 February 2005
Resolved 18 April 2005
Fire Fighting
Issued 3 November 1998
Resolved
Provide evidence of compliance with maintenance of portable fire extinguisher.
Condition: Unknown
Due 3 November 1998
Resolved 3 November 1998
Lifesaving
Issued 3 November 1998
Resolved
Provide evidence of compliance with 46 CFR 420, crew training.
Condition: Unknown
Due 3 November 1998
Resolved 3 November 1998
Lifesaving
Issued 3 November 1998
Resolved
Provide evidence of compliance with 46 CFR 185.520, drills and training.
Condition: Unknown
Due 3 November 1998
Resolved 3 November 1998
Lifesaving
Issued 3 November 1998
Resolved
Provide evidence of compliance with 46 CFR 185.702, maintenance of survivalcraft.
Condition: Unknown
Due 3 November 1998
Resolved 3 November 1998
Documentation
Issued 3 November 1998
Resolved
Provide current masters license.
Condition: Unknown
Due 3 November 1998
Resolved 3 November 1998
Lifesaving
Issued 3 November 1998
Resolved
Properly label PFD stowage.
Condition: Unknown
Due 3 November 1998
Resolved 3 November 1998
Documentation
Issued 3 November 1998
Resolved
Provide FCC operators license.
Condition: Unknown
Due 3 November 1998
Resolved 3 November 1998
Lifesaving
Issued 3 November 1998
Resolved
Renew retrotape on lifefloats as needed.
Condition: Unknown
Due 3 November 1998
Resolved 3 November 1998
Lifesaving
Issued 3 November 1998
Resolved
Renew inner lifeline of number two life float.
Condition: Unknown
Due 3 November 1998
Resolved 3 November 1998
Lifesaving
Issued 3 November 1998
Resolved
Make approved repairs to life floats where punctured.
Condition: Unknown
Due 3 November 1998
Resolved 3 November 1998
Lifesaving
Issued 3 November 1998
Resolved
Provide evidence of compliance with 46 CFR 185.720, survival craft maintenance and inspection.
Condition: Unknown
Due 3 November 1998
Resolved 3 November 1998
Accommodation/Occupational Safety
Issued 3 November 1998
Resolved
Provide evidence of that the installation of the stove and propane grill isin compliance with 46 CFR 177.410 (a), 46 CFR 184.220 and 46 CFR 184.240._x001C_
Condition: Unknown
Due 28 February 2000
Resolved 3 November 1998
Lifesaving
Issued 3 November 1998
Resolved
Renew PFD retro tape as needed.
Condition: Unknown
Due 3 November 1998
Resolved 3 November 1998
Documentation
Issued 21 October 1998
Resolved
Provide evidence of compliance with chemical testing program to include: current copies of consortium contract, crews list, description of random test procedures, copies of 1)pre-employment,2)SMI,3)reasonable cause & 4) random tests, Employee Assistance Program, latest MIS, test result records.
Condition: Unknown
Due 21 October 1998
Resolved 21 October 1998
Documentation
Issued 1 July 1998
Resolved
PROVIDE DOCUMENTATION FOR ISM, SAFETY MANAGEMENT EQUIVALENCY OR OBTAIN ISM CERTIFICATION FROM RECOGNIZED ORGANIZATION.
Condition: Unknown
Due 1 July 1998
Resolved 1 July 1998
Construction/Loadline
Issued 5 November 1997
Resolved
Grind down cracks in fiberglass epoxy fairing on fillet at forward end on starboard hull to expose any damage to wood/fiberglass and repair.
Condition: Unknown
Due 6 November 1997
Resolved 6 November 1997
Construction/Loadline
Issued 5 November 1997
Resolved
From the starboard side repair stringers #1, 2, 4, 7, & 9 where marked on under deck platform. Crop and renew areas so marked.
Condition: Unknown
Due 6 November 1997
Resolved 6 November 1997
Construction/Loadline
Issued 5 November 1997
Resolved
On forward beams make repairs to areas of dry rot and damaged areas where marked.
Condition: Unknown
Due 6 November 1997
Resolved 6 November 1997
Engineering
Issued 5 November 1997
Resolved
Make repairs to forward end of the outboard motor sled where fiberglass is delaminating from the alluminum substructure.
Condition: Unknown
Due 6 November 1997
Resolved 6 November 1997
Lifesaving
Issued 5 November 1997
Resolved
Remount the Emergency Position Indicating Radio Beacon on the exterior of the vessel.
Condition: Unknown
Due 10 March 1998
Resolved 10 March 1998
Construction/Loadline
Issued 1 October 1997
Resolved
Make repairs to mast prior to carrying passengers. Mast repairs must be made to the satisfaction of the attending marine inspector from CG Activities Baltimore.
Condition: Unknown
Due 30 October 1997
Resolved 7 October 1997
Lifesaving
Issued 22 October 1995
Resolved
REPLACE 6 SOLAS APPROVED PFD LIGHTS
Condition: Unknown
Due 22 October 1995
Resolved 22 October 1995
Lifesaving
Issued 22 October 1995
Resolved
REPLACE REFLECTIVE TAPE ON PFD AS NEEDED.
Condition: Unknown
Due 22 October 1995
Resolved 22 October 1995
Documentation
Issued 15 April 1994
Resolved
OBTAIN RADIO-TELEPHONE SAFETY CERTIFICATE (FCC 824).
Condition: Unknown
Due 15 April 1994
Resolved 15 April 1994
Construction/Loadline
Issued 2 September 1992
Resolved
GRIND DOWN AND RE-GLASS SURFACE CRACKS ALONG INSIDE OF HULLS.
Condition: Unknown
Due 2 September 1992
Resolved 2 September 1992
Electrical
Issued 2 September 1992
Resolved
CROP OUT OR PROPERLY DEAD END LOOSE WIRES IN AFTER MOST STBD COMPARTMENT AND FWD MOST PORT COMPARTMENT.
Condition: Unknown
Due 2 September 1992
Resolved 2 September 1992
Construction/Loadline
Issued 2 September 1992
Resolved
INSURE THAT CAPTIVE CHAINS ON BOTH AFT COMPARTMENTS HATCH COVERS ARE CONNECTED AT ALL TIMES.
Condition: Unknown
Due 2 September 1992
Resolved 2 September 1992
Construction/Loadline
Issued 2 September 1992
Resolved
REMOVE ALUMINUM STEM PLATE FOR STAY SAIL AND REPLACE WITH STAINLESS STEEL.
Condition: Unknown
Due 2 September 1992
Resolved 2 September 1992
Documentation
Issued 7 January 1992
Resolved
CONDUCT STABILITY TEST IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR FOR CARRIAGE OF LESS THAN 49 PASSENGERS OR COMPLETE STABILITY ANALYSIS FOR CARRIAGE OF MORE THAN 49 PASSENGERS AND CONDUCT FULL INCLINING EXPERIMENT.
Condition: Unknown
Due 7 January 1992
Resolved 7 January 1992