← All vessels
SEAVENTURE
Passenger (Inspected) · Passenger Ship class · Built 1990s · USCG Arctic District (CGD-A) · Other hulls named SEAVENTURE
SEAVENTURE is a 1990 passenger vessel (inspected). The Coast Guard has recorded 24 inspections since 1990, most recently in July 2019, along with 35 deficiencies — 1 with no resolution recorded — and 1 operational control.
Records from 1990 to 2019. Most recent: inspection, 17 July 2019.
- Built
- 1990
- Last inspected
- 17 July 2019
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 35 recorded · 1 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
8907424 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
C6JC3
356173
Flag
BAHAMAS, THE
—
Maury page id
psix-356173
Inspections, by type
…with no type recorded5
…past their stated due date1
Years with a record
13 calendar years (1990–2019)
The 24 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Tonnage as PSIX records it6752 - Convention (Subpart B), Gross Ton
2073 - Convention (Subpart B), Net Ton
1226 - Dead Weight, Ton
2073 - Convention (Subpart B), Net Ton
1226 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 24
17 July 2019
ISPS II Exam · Ballast Water Examination · Polar Code Examination · COC-CVE Annual
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6753429
7 September 2018
COC-CVE Annual · Ballast Water Examination · ISPS II Exam · Polar Code Examination
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6511747
14 July 2017
COC-CVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6215026
26 August 2015
ISPS II Exam · Ballast Water Examination · COC-CVE Annual
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5227179
14 July 2011
Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4081357
7 November 2008
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3358731
31 October 2008
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3354749
8 September 2008
Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 3320487
19 May 2008
MARPOL Annex I Examination · COC-CVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3208458
6 September 2006
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 2771252
2 September 2003
Certificate of Compliance
Administrative · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 1893946
27 August 2003
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1901021
6 September 2001
MARPOL Annex I Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1071509
7 August 2001
Quarterly Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1070216
3 May 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 289683
3 May 2001
Control Verification
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1064746
6 December 1995
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1187684
31 October 1995
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 878743
22 October 1995
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 871312
7 October 1995
Control Verification
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1431566
10 April 1995
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 376566
6 September 1992
Control Verification
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 947762
23 June 1991
Control Verification
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1250115
7 November 1990
Control Verification
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1225592
Deficiency record · 35
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 17 July 2019
No resolution recorded
Fire Main section on deck 2 located in passageway outside of crews laundry was found with an overhead leakdue to an 1/8" hole in piping. SOLAS 74 (2014) CH1 reg 11
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 September 2018
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Fire main has multiple temporary epoxy repairs throughout the vessel. 74 SOLAS (2014) Ch I Reg 11
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 7 September 2018
Resolved
The means for making decks watertight, and the arrangements adopted for closing openings in them, shall be to the satisfaction of the Administration. Access hatch to engine room workspace was not bolted down, presented a downflooding hazard and smoke/fire migration hazard. 74 SOLAS (2004) CH II-1 Reg 19
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 7 September 2018
Resolved
All inlets and discharges in the shell plating shall be fitted with efficient and accessible arrangements for preventing the accidental admission of water into the ship. Reverse osmosis overboard discharge through-hull has epoxy temporary repair between ship's hull and isolation valve. 74 SOLAS (2004) Ch II-1 Reg 17.9.1
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 7 September 2018
Resolved
The construction of all doors and door frames in "A" class divisions, with the means of securing them when closed, shall provide resistance to fire as well as to the passage of smoke and flame equivalent to that of the bulkheads in which the doors are situated. Threshold of fire door leading to the A/C control room in the engine room is wasted. 74 SOLAS (81 amend.) CH II-2 Reg 30.2
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 7 September 2018
Resolved
On-board training in the use of davit launched liferafts shall, whenever practicable, include the inflation and lowering of a liferaft intended for training purposes only. Training liferaft on board is not of the same type as installed liferafts. 74 SOLAR (2014) Ch III Reg 19.4.3
Operations/Management › Drills/Instruction › Abandon Ship
Issued 14 July 2017
Resolved
Every crem member with assigned emergency duties shall be familiar with these duties before the voyage begins. Crew for lifeboats 1 through 4 are unfamiliar with emergency equipment.
Stability › Unintentional Flooding › General
Issued 7 September 2015
Resolved
The through hull valve for the galley grey water overbaord is located below the water line and leaking between the valve and the skin of the ship. A temporary cement box patch has been installed by the crew.
Lifesaving › Lifeboat › Embarkation/Disembarkation Capabilities
Issued 19 May 2008
Resolved
PSCE Observed #2 Port side lifeboat not able to release properly during drill. Provide Class Report attesting to proper operations of all lifeboat davits. Rectify deficiencies within 08 days.
Fire Fighting › Ventilation Systems › Operating Controls
Issued 6 September 2006
Resolved
fire dampers (manual actuating devices); identified the following dampers non-operational (seized): #108; #301; & #306
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 6 September 2006
Resolved
Randomly conducted operational test on fire-doors; found (2) fire-doors non-operational (one on deck #2 and one on deck #3)
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 6 September 2006
Resolved
During engine space walk through, identified open paint can near emergency fire pump (presenting a potential fire hazard)
Fire Fighting
Issued 22 October 1995
Resolved
PROVIDE COPY OF UPDATED AND APPROVED FIRE CONTROL PLAN TO USCG MARINE SAFETY CENTER, NO LATER THAN 07 NOVEMBER, 1995._x001C_ _x001C_ _x001C_
Accommodation/Occupational Safety
Issued 7 October 1995
Resolved
Provide class society attestation to the modification and installation of azodiac workshop upper deck aft.
Accommodation/Occupational Safety
Issued 7 October 1995
Resolved
Provide class society attestation to the installation of a pool bar on the upper level.
Lifesaving
Issued 7 October 1995
Resolved
Properly stamp expiration date on all 6 liferaft hydrostatic releases priorto departure.
Lifesaving
Issued 7 October 1995
Resolved
Properly install and secure sea painters, for the aft two liferafts on the starboard side, prior to departure.
Lifesaving
Issued 7 October 1995
Resolved
Properly stow all paint containers in the on-deck stowage locker in way of the port side lifeboat no. 4.
Documentation
Issued 7 October 1995
Resolved
Provide copy of updated and approved fire control plan to USCG Marine Safety Center, no later than 07 November, 1995.
Fire Fighting
Issued 7 October 1995
Resolved
Re-install A-60 insulation in way of watertight door number 5 where removed, no later than 22 October, 1995.
Fire Fighting
Issued 7 October 1995
Resolved
Re-install A-60 insulation in way of emergency exit for garbage compactor room, where removed, no later than 22 October, 1995.
Accommodation/Occupational Safety
Issued 7 October 1995
Resolved
Prior to 22 October 1995, provide and install shut off valves of comparablematerial in way of PVC thru-bulkhead penetrations in upper level of engine room spaces.
Fire Fighting
Issued 7 October 1995
Resolved
Properly label the #2 firepump (mislabeled as the emergency firepump).
Lifesaving
Issued 7 October 1995
Resolved
Remove, and properly stow, flammables located in food waste lift, pior to departure.
Lifesaving
Issued 7 October 1995
Resolved
Replace broken brake release cable to the port side forward (#2) lifeboat, no later than 22 October, 1995.
Accommodation/Occupational Safety
Issued 7 October 1995
Resolved
Provide class society attestation to the installation of two, 2-person crewmember berthing rooms located on the 4th deck forward near the bosun's stores.
Accommodation/Occupational Safety
Issued 7 October 1995
Resolved
Provide class society attestation for modifications and installation of a food waste elevator located in the aft galley extending vertically 3 decks.Update approved plans for the modification and provide access for inspection.
Accommodation/Occupational Safety
Issued 7 October 1995
Resolved
Prior to utilization, provide class society attestation for the installation of A-60 insulation to two, 2-person crew berthing rooms in wayof the former laundry space, 3rd deck, above engine room casing.
Fire Fighting
Issued 7 October 1995
Resolved
Prove proper operation of fire sprinkler pump, prior to departure.
Accommodation/Occupational Safety
Issued 7 October 1995
Resolved
Provide classification society's attestation that emergency egress for bosun's store room has been provided and is acceptable, no later than 07 November, 1995.
Fire Fighting
Issued 7 October 1995
Resolved
Provide firefighting nozzle at station number 706, port side near lifeboat number 4, prior to departure.
Construction/Loadline
Issued 7 October 1995
Resolved
Prove proper operation of sprikler pump room bilge pump, prior to departure.
Electrical
Issued 7 October 1995
Resolved
Place rubber matting in way of emergency generator switchboard for personnel protection.
Electrical
Issued 7 October 1995
Resolved
Replace burned-out emergency lighting bulbs in forward stairtowers, prior to departure.
Lifesaving
Issued 7 October 1995
Resolved
Remove, and properly stow all paint containers in the bosun's locker forward, under the navigational bridge, prior to departure.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.