Records from 1993 to 2003. Most recent: inspection, 8 September 2003.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 18
8 September 2003
Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1899723
21 March 2003
Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1769609
23 July 2002
Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1650580
1 August 2001
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1070996
14 June 2001
COI Inspection · Deficiency Check · Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1465640
3 May 2000
Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1049853
13 September 1999
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 784076
13 July 1999
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1097197
22 June 1999
Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1191837
22 June 1999
Examination of Repairs · Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1381511
7 July 1998
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 794299
22 April 1998
COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1456600
21 May 1997
Hull Examination · Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1418163
9 May 1996
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1083302
27 April 1995
Inclining Experiment · Initial Certification
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1402035
14 March 1995
Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1177769
14 March 1995
Hull Examination · Plan Review "T" Boat
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1402034
19 January 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 674647
Documentation › Logs/Records › Drug Test Records
Issued 8 September 2003
Resolved
Provide drug and alcohol testing program for the company.
Action required: 705 - Other - as specified
Due 5 October 2003
Resolved 13 September 2008
Resolution: Vessel sank at the dock in Kemah Small Boat Marina, Kemah, TX 13 Sep 2008 during Hurricane IKE.
Documentation › Certificates/Documents › Passenger Ship Safety Certificate
Issued 8 September 2003
Resolved
Provide current CPR card for 50% of the crew.
Action required: 705 - Other - as specified
Due 5 October 2003
Resolved 13 September 2008
Resolution: Vessel sank at the dock in Kemah Small Boat Marina, Kemah, TX 13 Sep 2008 during Hurricane IKE.
Personnel › Training › Able Seaman
Issued 8 September 2003
Resolved
Provide training log for inspection.
Action required: 705 - Other - as specified
Due 5 October 2003
Resolved 13 September 2008
Resolution: Vessel sank at the dock in Kemah Small Boat Marina, Kemah, TX 13 Sep 2008 during Hurricane IKE.
Lifesaving › Liferaft Equipment › First-aid Kit
Issued 8 September 2003
Resolved
Provide current medical kit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 October 2003
Resolved 13 September 2008
Resolution: Vessel sank at the dock in Kemah Small Boat Marina, Kemah, TX 13 Sep 2008 during Hurricane IKE.
Lifesaving › Buoyant Smoke Signals › General
Issued 8 September 2003
Resolved
Provide working strob light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 October 2003
Resolved 13 September 2008
Resolution: Vessel sank at the dock in Kemah Small Boat Marina, Kemah, TX 13 Sep 2008 during Hurricane IKE.
Engineering › Bilge Water Management System › Piping
Issued 8 September 2003
Resolved
Repair STBD raw water intake valve.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 October 2003
Resolved 13 September 2008
Resolution: Vessel sank at the dock in Kemah Small Boat Marina, Kemah, TX 13 Sep 2008 during Hurricane IKE.
Construction/Loadline › Hull › Keel
Issued 8 September 2003
Resolved
Dry dock vessel for hull inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 January 2004
Resolved 13 September 2008
Resolution: Vessel sank at the dock in Kemah Small Boat Marina, Kemah, TX 13 Sep 2008 during Hurricane IKE.
Engineering › Fuel Oil Storage/Transfer System › Ventilation
Issued 8 September 2003
Resolved
Realign port and starboard diesel tank vents to eliminate liquid trap.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 October 2003
Resolved 13 September 2008
Resolution: Vessel sank at the dock in Kemah Small Boat Marina, Kemah, TX 13 Sep 2008 during Hurricane IKE.
Engineering › Steering Gear System › Bracket/Clamp
Issued 8 September 2003
Resolved
Provide double nuts on both port and stbd stuffing boxes.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 October 2003
Resolved 13 September 2008
Resolution: Vessel sank at the dock in Kemah Small Boat Marina, Kemah, TX 13 Sep 2008 during Hurricane IKE.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 8 September 2003
Resolved
Secure all loose wiring and make approved repairs IWO the E/R and bilges.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 October 2003
Resolved 13 September 2008
Resolution: Vessel sank at the dock in Kemah Small Boat Marina, Kemah, TX 13 Sep 2008 during Hurricane IKE.
Engineering › Diesel Engine (propulsion-direct drive) › Valve
Issued 8 September 2003
Resolved
Repair port engine oil drip pan.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 October 2003
Resolved 13 September 2008
Resolution: Vessel sank at the dock in Kemah Small Boat Marina, Kemah, TX 13 Sep 2008 during Hurricane IKE.
Engineering › Bilge Water Management System › Piping
Issued 8 September 2003
Resolved
Remove obstacle IWO raw water intake vlave and secure obstacle from shifting.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 October 2003
Resolved 13 September 2008
Resolution: Vessel sank at the dock in Kemah Small Boat Marina, Kemah, TX 13 Sep 2008 during Hurricane IKE.
Fire Fighting
Issued 14 June 2001
Resolved
PROVIDE INSTRUCTIONS FOR OPERATING FIXED HALON SYSTEM AT THE CONTROL STATION PER 46 CFR 185.612(a).
Condition: Unknown
Due 14 July 2001
Resolved 2 August 2001
Engineering
Issued 14 June 2001
Resolved
PROVIDE MARKINGS FOR LOCATION AND OPERATION OF REMOTE FUEL SHUTOFF STATION PER 46 CFR 185.608.
Condition: Unknown
Due 14 July 2001
Resolved 2 August 2001
Electrical
Issued 14 June 2001
Resolved
PROVIDE COVER FOR ELECTRICAL OUTLET ON AFT DECK STBD SIDE.
Condition: Unknown
Due 14 July 2001
Resolved 2 August 2001
Construction/Loadline
Issued 3 May 2000
Resolved
Plugh holes in watertight bulkhead on fwd stbd side.
Condition: Unknown
Due 3 May 2000
Resolved 3 May 2000
Electrical
Issued 3 May 2000
Resolved
Remove orange "electrical cord" conductor for hi level bilge alarms and replace with proper conductor.
Condition: Unknown
Due 3 May 2000
Resolved 3 May 2000
Documentation
Issued 3 May 2000
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 3 May 2000
Resolved 3 May 2000
Unknown
Issued 3 May 2000
Resolved
Double clamp MSD hose connection and cap fwd ovbd discharge.
Condition: Unknown
Due 3 May 2000
Resolved 3 May 2000
Fire Fighting
Issued 3 May 2000
Resolved
Provide vent closures for Engine room vents to be used with fixed gas fire extinguishing system.
Condition: Unknown
Due 3 May 2000
Resolved 3 May 2000
Unknown
Issued 3 May 2000
Resolved
Amend emergency instructions to include fixed fire fighting system for engine room operation and post in a conspicous location.
Condition: Unknown
Due 3 May 2000
Resolved 3 May 2000
Unknown
Issued 3 May 2000
Resolved
Properly support generator fuel lines.
Condition: Unknown
Due 3 May 2000
Resolved 3 May 2000
Unknown
Issued 3 May 2000
Resolved
Provide approved type fuel hose for 120V generators.
Condition: Unknown
Due 3 May 2000
Resolved 3 May 2000
Navigation
Issued 3 May 2000
Resolved
Remove excessive play in steering at lower link of vertical operating rod in engine room P/S aft.
Condition: Unknown
Due 3 May 2000
Resolved 3 May 2000
Construction/Loadline
Issued 3 May 2000
Resolved
Double clamp bilge system discharge in engine room.
Condition: Unknown
Due 3 May 2000
Resolved 3 May 2000
Construction/Loadline
Issued 3 May 2000
Resolved
Properly marke bilge manifold valves to indicate suction sources, etc.
Condition: Unknown
Due 3 May 2000
Resolved 3 May 2000
Construction/Loadline
Issued 3 May 2000
Resolved
Prove proper operation of engine room hi level bilge alarm.
Condition: Unknown
Due 3 May 2000
Resolved 3 May 2000
Construction/Loadline
Issued 3 May 2000
Resolved
Repair overhead in way of bridge on stbd side.
Condition: Unknown
Due 3 May 2000
Resolved 3 May 2000
Unknown
Issued 3 May 2000
Resolved
Repair air cond condensate leak in engine room port side forward and reattach stiffener in way of.
Condition: Unknown
Due 3 May 2000
Resolved 3 May 2000
Electrical
Issued 3 May 2000
Resolved
Hard wire 12V and 32V battery chargers.
Condition: Unknown
Due 3 May 2000
Resolved 3 May 2000
Unknown
Issued 3 May 2000
Resolved
Mark engine room hatch " Emergency Exit Do Not Block"
Condition: Unknown
Due 3 May 2000
Resolved 3 May 2000
Electrical
Issued 3 May 2000
Resolved
Make 12V battery charger drip proof.
Condition: Unknown
Due 3 May 2000
Resolved 3 May 2000
Fire Fighting
Issued 22 June 1999
Resolved
Provide additional B-II fire extinguisher per Certificate of Inspection (COI).
Condition: Unknown
Due 22 June 1999
Resolved 22 June 1999
Engineering
Issued 22 June 1999
Resolved
Vsl diesel fuel tank vents not in conformance with 46 CFR 182.450. Vsl is required to adhere with regulatory provisions not later than 07JUL99.
Condition: Unknown
Due 22 June 1999
Resolved 22 June 1999
Documentation
Issued 22 June 1999
Resolved
Provide satisfactory evidence that drug testing program meets the provisions of 46 CFR 16.
Condition: Unknown
Due 22 June 1999
Resolved 22 June 1999
Fire Fighting
Issued 22 June 1999
Resolved
Install fixed fire extinguishing system (presently on-back order) in accordance with the provisions of 46 CFR 181.400 et seq.
Condition: Unknown
Due 22 June 1999
Resolved 22 June 1999
Lifesaving
Issued 22 April 1998
Resolved
Vessel currently has only 41 adult PFDs. Provied (01) additional adult PFDprior to 22JUN98. Vessel restricted to no more than 41 POB when underway.
Condition: Unknown
Due 22 June 1998
Resolved 10 July 1998
Construction/Loadline
Issued 22 April 1998
Resolved
Provide bilge pump indicator light at operating station IAW 46CFR182.520(a)
Condition: Unknown
Due 22 June 1998
Resolved 10 July 1998
Engineering
Issued 22 April 1998
Resolved
Install handles on MDE sea suction valves. 46CFR179.350(c)
Condition: Unknown
Due 7 July 1998
Resolved 7 July 1998
Lifesaving
Issued 22 April 1998
Resolved
Conduct emergency drills. Drills to include fire and man overboard. 46CFR185.520 & 185.524.
Condition: Unknown
Due 22 June 1998
Resolved 10 July 1998
Lifesaving
Issued 22 April 1998
Resolved
Retro tape not properly installed. Install tape prior to 22JUN98. 46CFR185.604(i)
Condition: Unknown
Due 22 June 1998
Resolved 10 July 1998
Engineering
Issued 21 May 1997
Resolved
HARD PIPE FUEL HOSE SUPPLY AND RETURN FROM THE FUEL TANK TO THE MAIN ENGINEFILTERS WITHOUT UTILIZING LENGTHS OF APPROVED F/O HOSE LONGER THAN 42 INCHES (WATCH FOR CHAFING). FITTINGS MUST BE MECHANICALLY FITTED (NOT HOSECLAMPS) AND MADE WATERTIGHT WHERE PASSING THROUGH THE AFT E/R BULKHEAD.
Condition: Unknown
Due 21 May 1997
Resolved 21 May 1997