MAURY USCG vessel records Sign in
← All vessels

ISLAND PRINCESS

ISLAND PRINCESS is a 1964 passenger vessel (inspected). The Coast Guard has recorded 18 inspections since 1993, most recently in September 2003, along with 42 deficiencies.

Records from 1993 to 2003. Most recent: inspection, 8 September 2003.

Built
1964
Last inspected
8 September 2003
Documentation
No Operation - PM · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCY2482
356187
Flag
UNITED STATES
—
Maury page id
psix-356187

Inspections, by type

…with no type recorded1
Years with a record 10 calendar years (1993–2003)
The 18 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 23 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)54.0 ft × 14.5 ft × 8.0 ft
Registered tonnagegross 45 / net 33
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCHRIS-CRAFT CORPORATION · POMPANO BEACH, FL, UNITED STATES · built 1964
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portGALVESTON, TX
Trade endorsementsCoastwise, unrestricted
DocumentationNo Operation - PM · issued 25 August 2005 · expires 31 August 2006
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it45 - Regulatory (Subpart C or D), Gross Ton
33 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WCY2482MMSI not assigned · expired · compulsorily equipped · granted 25 March 1998, cancelled 31 May 2008
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 18

8 September 2003 Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1899723
21 March 2003 Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1769609
23 July 2002 Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1650580
1 August 2001 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1070996
14 June 2001 COI Inspection · Deficiency Check · Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1465640
3 May 2000 Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1049853
13 September 1999 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 784076
13 July 1999 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1097197
22 June 1999 Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1191837
22 June 1999 Examination of Repairs · Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1381511
7 July 1998 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 794299
22 April 1998 COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1456600
21 May 1997 Hull Examination · Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1418163
9 May 1996 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1083302
27 April 1995 Inclining Experiment · Initial Certification
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1402035
14 March 1995 Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1177769
14 March 1995 Hull Examination · Plan Review "T" Boat
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1402034
19 January 1993 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 674647

Deficiency record · 42

Documentation › Logs/Records › Drug Test Records
Issued 8 September 2003 Resolved
Provide drug and alcohol testing program for the company.
Action required: 705 - Other - as specified
Due 5 October 2003
Resolved 13 September 2008
Resolution: Vessel sank at the dock in Kemah Small Boat Marina, Kemah, TX 13 Sep 2008 during Hurricane IKE.
Documentation › Certificates/Documents › Passenger Ship Safety Certificate
Issued 8 September 2003 Resolved
Provide current CPR card for 50% of the crew.
Action required: 705 - Other - as specified
Due 5 October 2003
Resolved 13 September 2008
Resolution: Vessel sank at the dock in Kemah Small Boat Marina, Kemah, TX 13 Sep 2008 during Hurricane IKE.
Personnel › Training › Able Seaman
Issued 8 September 2003 Resolved
Provide training log for inspection.
Action required: 705 - Other - as specified
Due 5 October 2003
Resolved 13 September 2008
Resolution: Vessel sank at the dock in Kemah Small Boat Marina, Kemah, TX 13 Sep 2008 during Hurricane IKE.
Lifesaving › Liferaft Equipment › First-aid Kit
Issued 8 September 2003 Resolved
Provide current medical kit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 October 2003
Resolved 13 September 2008
Resolution: Vessel sank at the dock in Kemah Small Boat Marina, Kemah, TX 13 Sep 2008 during Hurricane IKE.
Lifesaving › Buoyant Smoke Signals › General
Issued 8 September 2003 Resolved
Provide working strob light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 October 2003
Resolved 13 September 2008
Resolution: Vessel sank at the dock in Kemah Small Boat Marina, Kemah, TX 13 Sep 2008 during Hurricane IKE.
Engineering › Bilge Water Management System › Piping
Issued 8 September 2003 Resolved
Repair STBD raw water intake valve.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 October 2003
Resolved 13 September 2008
Resolution: Vessel sank at the dock in Kemah Small Boat Marina, Kemah, TX 13 Sep 2008 during Hurricane IKE.
Construction/Loadline › Hull › Keel
Issued 8 September 2003 Resolved
Dry dock vessel for hull inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 January 2004
Resolved 13 September 2008
Resolution: Vessel sank at the dock in Kemah Small Boat Marina, Kemah, TX 13 Sep 2008 during Hurricane IKE.
Engineering › Fuel Oil Storage/Transfer System › Ventilation
Issued 8 September 2003 Resolved
Realign port and starboard diesel tank vents to eliminate liquid trap.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 October 2003
Resolved 13 September 2008
Resolution: Vessel sank at the dock in Kemah Small Boat Marina, Kemah, TX 13 Sep 2008 during Hurricane IKE.
Engineering › Steering Gear System › Bracket/Clamp
Issued 8 September 2003 Resolved
Provide double nuts on both port and stbd stuffing boxes.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 October 2003
Resolved 13 September 2008
Resolution: Vessel sank at the dock in Kemah Small Boat Marina, Kemah, TX 13 Sep 2008 during Hurricane IKE.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 8 September 2003 Resolved
Secure all loose wiring and make approved repairs IWO the E/R and bilges.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 October 2003
Resolved 13 September 2008
Resolution: Vessel sank at the dock in Kemah Small Boat Marina, Kemah, TX 13 Sep 2008 during Hurricane IKE.
Engineering › Diesel Engine (propulsion-direct drive) › Valve
Issued 8 September 2003 Resolved
Repair port engine oil drip pan.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 October 2003
Resolved 13 September 2008
Resolution: Vessel sank at the dock in Kemah Small Boat Marina, Kemah, TX 13 Sep 2008 during Hurricane IKE.
Engineering › Bilge Water Management System › Piping
Issued 8 September 2003 Resolved
Remove obstacle IWO raw water intake vlave and secure obstacle from shifting.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 October 2003
Resolved 13 September 2008
Resolution: Vessel sank at the dock in Kemah Small Boat Marina, Kemah, TX 13 Sep 2008 during Hurricane IKE.
Fire Fighting
Issued 14 June 2001 Resolved
PROVIDE INSTRUCTIONS FOR OPERATING FIXED HALON SYSTEM AT THE CONTROL STATION PER 46 CFR 185.612(a).
Condition: Unknown
Due 14 July 2001
Resolved 2 August 2001
Engineering
Issued 14 June 2001 Resolved
PROVIDE MARKINGS FOR LOCATION AND OPERATION OF REMOTE FUEL SHUTOFF STATION PER 46 CFR 185.608.
Condition: Unknown
Due 14 July 2001
Resolved 2 August 2001
Electrical
Issued 14 June 2001 Resolved
PROVIDE COVER FOR ELECTRICAL OUTLET ON AFT DECK STBD SIDE.
Condition: Unknown
Due 14 July 2001
Resolved 2 August 2001
Construction/Loadline
Issued 3 May 2000 Resolved
Plugh holes in watertight bulkhead on fwd stbd side.
Condition: Unknown
Due 3 May 2000
Resolved 3 May 2000
Electrical
Issued 3 May 2000 Resolved
Remove orange "electrical cord" conductor for hi level bilge alarms and replace with proper conductor.
Condition: Unknown
Due 3 May 2000
Resolved 3 May 2000
Documentation
Issued 3 May 2000 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 3 May 2000
Resolved 3 May 2000
Unknown
Issued 3 May 2000 Resolved
Double clamp MSD hose connection and cap fwd ovbd discharge.
Condition: Unknown
Due 3 May 2000
Resolved 3 May 2000
Fire Fighting
Issued 3 May 2000 Resolved
Provide vent closures for Engine room vents to be used with fixed gas fire extinguishing system.
Condition: Unknown
Due 3 May 2000
Resolved 3 May 2000
Unknown
Issued 3 May 2000 Resolved
Amend emergency instructions to include fixed fire fighting system for engine room operation and post in a conspicous location.
Condition: Unknown
Due 3 May 2000
Resolved 3 May 2000
Unknown
Issued 3 May 2000 Resolved
Properly support generator fuel lines.
Condition: Unknown
Due 3 May 2000
Resolved 3 May 2000
Unknown
Issued 3 May 2000 Resolved
Provide approved type fuel hose for 120V generators.
Condition: Unknown
Due 3 May 2000
Resolved 3 May 2000
Navigation
Issued 3 May 2000 Resolved
Remove excessive play in steering at lower link of vertical operating rod in engine room P/S aft.
Condition: Unknown
Due 3 May 2000
Resolved 3 May 2000
Construction/Loadline
Issued 3 May 2000 Resolved
Double clamp bilge system discharge in engine room.
Condition: Unknown
Due 3 May 2000
Resolved 3 May 2000
Construction/Loadline
Issued 3 May 2000 Resolved
Properly marke bilge manifold valves to indicate suction sources, etc.
Condition: Unknown
Due 3 May 2000
Resolved 3 May 2000
Construction/Loadline
Issued 3 May 2000 Resolved
Prove proper operation of engine room hi level bilge alarm.
Condition: Unknown
Due 3 May 2000
Resolved 3 May 2000
Construction/Loadline
Issued 3 May 2000 Resolved
Repair overhead in way of bridge on stbd side.
Condition: Unknown
Due 3 May 2000
Resolved 3 May 2000
Unknown
Issued 3 May 2000 Resolved
Repair air cond condensate leak in engine room port side forward and reattach stiffener in way of.
Condition: Unknown
Due 3 May 2000
Resolved 3 May 2000
Electrical
Issued 3 May 2000 Resolved
Hard wire 12V and 32V battery chargers.
Condition: Unknown
Due 3 May 2000
Resolved 3 May 2000
Unknown
Issued 3 May 2000 Resolved
Mark engine room hatch " Emergency Exit Do Not Block"
Condition: Unknown
Due 3 May 2000
Resolved 3 May 2000
Electrical
Issued 3 May 2000 Resolved
Make 12V battery charger drip proof.
Condition: Unknown
Due 3 May 2000
Resolved 3 May 2000
Fire Fighting
Issued 22 June 1999 Resolved
Provide additional B-II fire extinguisher per Certificate of Inspection (COI).
Condition: Unknown
Due 22 June 1999
Resolved 22 June 1999
Engineering
Issued 22 June 1999 Resolved
Vsl diesel fuel tank vents not in conformance with 46 CFR 182.450. Vsl is required to adhere with regulatory provisions not later than 07JUL99.
Condition: Unknown
Due 22 June 1999
Resolved 22 June 1999
Documentation
Issued 22 June 1999 Resolved
Provide satisfactory evidence that drug testing program meets the provisions of 46 CFR 16.
Condition: Unknown
Due 22 June 1999
Resolved 22 June 1999
Fire Fighting
Issued 22 June 1999 Resolved
Install fixed fire extinguishing system (presently on-back order) in accordance with the provisions of 46 CFR 181.400 et seq.
Condition: Unknown
Due 22 June 1999
Resolved 22 June 1999
Lifesaving
Issued 22 April 1998 Resolved
Vessel currently has only 41 adult PFDs. Provied (01) additional adult PFDprior to 22JUN98. Vessel restricted to no more than 41 POB when underway.
Condition: Unknown
Due 22 June 1998
Resolved 10 July 1998
Construction/Loadline
Issued 22 April 1998 Resolved
Provide bilge pump indicator light at operating station IAW 46CFR182.520(a)
Condition: Unknown
Due 22 June 1998
Resolved 10 July 1998
Engineering
Issued 22 April 1998 Resolved
Install handles on MDE sea suction valves. 46CFR179.350(c)
Condition: Unknown
Due 7 July 1998
Resolved 7 July 1998
Lifesaving
Issued 22 April 1998 Resolved
Conduct emergency drills. Drills to include fire and man overboard. 46CFR185.520 & 185.524.
Condition: Unknown
Due 22 June 1998
Resolved 10 July 1998
Lifesaving
Issued 22 April 1998 Resolved
Retro tape not properly installed. Install tape prior to 22JUN98. 46CFR185.604(i)
Condition: Unknown
Due 22 June 1998
Resolved 10 July 1998
Engineering
Issued 21 May 1997 Resolved
HARD PIPE FUEL HOSE SUPPLY AND RETURN FROM THE FUEL TANK TO THE MAIN ENGINEFILTERS WITHOUT UTILIZING LENGTHS OF APPROVED F/O HOSE LONGER THAN 42 INCHES (WATCH FOR CHAFING). FITTINGS MUST BE MECHANICALLY FITTED (NOT HOSECLAMPS) AND MADE WATERTIGHT WHERE PASSING THROUGH THE AFT E/R BULKHEAD.
Condition: Unknown
Due 21 May 1997
Resolved 21 May 1997

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.