ENDLESS SUMMER III

ENDLESS SUMMER III is a 1990 passenger vessel (inspected). The Coast Guard has recorded 61 inspections since 1990, most recently in February 2026, along with 143 deficiencies, 7 operational controls and 1 casualty investigation in 2014.

Records from 1990 to 2026. Most recent: inspection, 19 February 2026.

Built
1990
Last inspected
19 February 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDC8789
356427
Flag
UNITED STATES
367093080
Maury page id
psix-356427

Inspections, by type

…with no type recorded3
Years with a record 33 calendar years (1990–2026)
The 61 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)40.7 ft × 13.2 ft × 8.2 ft
Registered tonnagegross 29 / net 23
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMICHAEL FITZ CUSTOM BOATS · NAPLES, FL, UNITED STATES · built 1990
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portST AUGUSTINE, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 12 February 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it29 - Simplified, Gross Ton
23 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDJ2743MMSI 367093080 · active · compulsorily equipped · granted 8 November 2016, expires 8 November 2026
WDC8789MMSI 367093080 · expired · compulsorily equipped · granted 15 February 2006, cancelled 16 April 2016
WAP8291MMSI not assigned · expired · compulsorily equipped · granted 11 October 1995, cancelled 4 February 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 61

19 February 2026 Annual Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8305316
21 March 2025 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8097406
13 December 2024 Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8047126
22 June 2024 In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7940103
22 February 2024 Deficiency Check · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7868727
12 December 2023 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7838095
22 November 2022 Drydock Exam · Internal Structural Exam · COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7600589
4 March 2022 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7403822
17 February 2021 Annual Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7136476
1 February 2021 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7134532
28 December 2020 Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7112731
20 April 2020 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6941352
12 February 2020 Deficiency Check · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6908039
25 February 2019 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6631553
26 March 2018 Administrative Inspection · In-Service Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6416210
4 December 2017 DAPI Audit · COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6315389
3 March 2017 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6098476
19 January 2017 In-Service Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6073663
28 November 2016 Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6048769
8 February 2016 Deficiency Check · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5808298
3 March 2014 Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4809148
9 January 2012 DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4219679
1 August 2011 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4131965
18 January 2011 Examination of Repairs · Annual Inspection · Deficiency Check · DAPI Audit · Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3955817
26 February 2010 DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3686409
24 February 2009 Internal Structural Exam · Drydock Exam · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3422276
4 June 2008 Administrative Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3226917
5 December 2007 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3110208
4 December 2007 COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3098509
8 March 2007 Annual Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2868954
1 March 2006 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2589092
2 March 2005 Re-Inspection · Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2302719
5 April 2004 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2037806
8 March 2004 Annual Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2022801
1 April 2003 Hull Examination · Internal Structural Exam
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1769369
19 December 2002 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1724996
26 March 2002 Periodic Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1600545
27 March 2001 Hull Examination · Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1384707
24 December 1999 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1376010
20 May 1999 Type not recorded
No type recorded · USCGC PEA ISLAND (WPB 1347) · USCG Southeast District (CGD-SE) · Activity 1508519
17 May 1999 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 65652
8 March 1999 Re-Inspection · Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1471547
8 April 1998 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 791145
9 March 1998 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 784744
11 April 1997 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1099158
17 December 1996 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1092807
22 January 1996 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1185336
3 January 1996 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 879215
28 December 1994 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 850964
16 December 1994 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 845263
17 December 1993 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 848999
2 December 1993 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 847743
11 January 1993 Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1133561
3 March 1992 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1270069
27 February 1992 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 952575
6 January 1992 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1265037
18 December 1991 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 952016
29 July 1991 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1000723
26 December 1990 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1224406
18 December 1990 Hull Examination · Initial Certification · Initial Construction-Excluding Oversight
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 926204
13 December 1990 Plan Review "T" Boat
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 900004

Deficiency record · 143

07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 19 February 2026 Resolved
A pre-engineered fixed gas fire extinguishing system must: be installed in accordance with manufacturer's instruction. Door in between engine and steering space was not secure. 46 CFR 181.420(a)(4)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 March 2026
Resolution: Door secured.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 19 February 2026 Resolved
Sternlight shall be visible from at least 2 miles. Sternlight inoperable. 46 CFR 183.420 33 CFR 83.22(b)(iii)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 March 2026
Resolved 2 March 2026
Resolution: Stern light operable.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 19 February 2026 Resolved
A vessel must be provided with 1 portable hand bilge pump. Vessel does not have a portable hand bilge pump. 46 CFR 182.520(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 March 2026
Resolved 2 March 2026
Resolution: Hand bilge pump provided.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 February 2026 Resolved
All cable/ wire must be installed with metal supports spaced not more than 24 inches apart. Electrical wire on overhead space was hanging from ceiling. 46 CFR 183.340(b)(4)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 March 2026
Resolved 2 March 2026
Resolution: Cable secured.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 19 February 2026 Resolved
A penetration in a watertight bulkhead must be as high as far inboard in the bulkhead as practicable, and made watertight. Fwd engine room bulkhead penetration is not watertight. 46 CFR 179.320(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 March 2026
Resolved 2 March 2026
Resolution: Engine room bulkhead penetration made watertight.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 19 February 2026 Resolved
A vessel must comply with FCC/ 47 CFR 80. Vessel does not have a station license or radio telephone certs. on board. 46 CFR 184.502
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 March 2026
Resolved 6 March 2026
Resolution: Received photo of Radio Safety Certificate.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 25 March 2025 Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. Liferaft quick release gear inoperable.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2025
Resolved 3 April 2025
Resolution: Received, reviewed and accpted evidence correcting the deficiency.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 25 March 2025 Resolved
All escape hatches and other emergency exits must be marked on both sides "EMERGENCY EXIT, KEEP CLEAR." Escape hatch not marked.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 April 2025
Resolved 3 April 2025
Resolution: Received, reviewed and accpted evidence correcting the deficiency.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 March 2025 Resolved
At each inspection test pre-engineered fire protection equipment. Means of securing air not present.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 April 2025
Resolved 4 April 2025
Resolution: USCG MI verified deficiency has been corrected properly.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 21 March 2025 Resolved
Your vessel must undergo an annual inspection within 3 months before or after each anniversary date. You failed to have an annual inspection within the 3 months before or after you anniversary date of 30 November 2024.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 March 2025
Resolution: USCG MIs completed a satisfactory Annual Inspection.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 19 December 2024 Resolved
The owner shall make a vessel available for dry dock exams and internal structural exam. The following worklist items need to be completed prior to credit dry dock. A. Replace starboard rudder key. B. Renew fiberglass on starboard aft quarter. C. Replace port and starboard cutlass bearing. D. Renew fiberglass in way of bow. E. Replace starboard shaft. F. Replace two broken thru hole valves in port pump room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 January 2025
Resolved 3 January 2025
Resolution: All worklist items rectified.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 June 2024 Resolved
The owner, charterer, managing operator, or master of must keep a correct list of the names of all persons that embark on and disembark from the vessel and the list shall be available to the Coast Guard upon request. Vessel was unable to provide list of crew and passengers to the Coast Guard upon request. Vessel owner must provide Coast with updated process on how passenger lists are recorded and ready upon request.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 June 2024
Resolved 26 June 2024
Resolution: Passenger list with names will be kept by vessel captain and owner ashore for every voyage.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 February 2024 Resolved
Ring life buoy light is incorrect type. Replace with correct light. Restricted to daytime operations until replaced.
Action required: 705 - Other - as specified
Resolved 29 February 2024
Resolution: New approved light was installed.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 22 February 2024 Resolved
Hydrostatic release on IBA is expired. Replace with valid hydrostatic release.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 February 2024
Resolved 28 February 2024
Resolution: Sent pictures of new hydrostatic release installed.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 February 2024 Resolved
Bimini top has temporary repairs. Weld to make repairs permanent.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 March 2024
Resolved 3 April 2024
Resolution: Welded broken components back together.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 February 2024 Resolved
No portable hand fire pump onboard. Obtain fire buckets to meet requirement.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 March 2024
Resolved 28 February 2024
Resolution: Obtained buckets.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 February 2024 Resolved
Wiring in port forward salon is taped to pipe/conduit. Install proper wire supports.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 March 2024
Resolved 28 February 2024
Resolution: Secured wiring using metal bands and removed tape.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 2 December 2022 Resolved
Rails shall be installed near the periphery of all weatherdecks accessible to passengers and crew. Bimini stanchon and handrails are loose or cracked.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2023
Resolved 12 December 2023
Resolution: Verified rail installation.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 2 December 2022 Resolved
Flexible hose designed for use with a hose clamps may be installed with two clamps at both ends of the hose. Saltwater hoses on main diesle engines and generators are missing second clamp.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 December 2022
Resolved 8 December 2022
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 22 November 2022 Resolved
A vessel must carry one floating waterlight. Waterlight has a crack in shell.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 January 2023
Resolved 8 December 2022
10 - Safety of Navigation › N/A - No Subsystem › Life-saving signals
Issued 17 February 2021 Resolved
ALL VESSELS SHALL CARRY APPROPRIATE NUMBER PYROTECHNIC DISTRESS SIGNALS. VESSEL DID NOT HAVE APPROPRIATE NUMBER OF DISTRESS SIGNALS. PROVIDE APPROPRIATE NUMBER OF DISTRESS SIGNALS. 46 CFR 180.35-5
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 February 2021
Resolution: VESSEL PURCHASED REQUIRED NUMBER OF DISTRESS SIGNALS PRIOR TO INSPECTORS DEPARTING.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 February 2021 Resolved
PROVISIONS SHALL BE MADE TO PREVENT THE ADMISSION OF AIR INTO THE SPACE PROTECTED. VESSELS HAD BULKHEAD PRENETRATIONS ON THE FORWARD BULKHEAD IN THE ENGINE SPACE THAT WERE NOT AIR TIGHT. MAKE AIRE TIGHT WITH APPROPRIATE MATERIAL. 46 CFR 181.20-35
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 March 2021
Resolved 18 February 2021
Resolution: VESSEL MADE BULKHEAD PENETRATIONS AIR TIGHT WITH APPROVED MATERIAL.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 17 February 2021 Resolved
A VESSEL MUST CARRY APPROVED FIRST AID KIT. VESSEL'S FIRST AID KIT DID NOT HAVE ALL REQUIRED CONTENTS. PROCURE WIRE SPLINT FOR FIRST AID KIT. 46 CFR 184.710 46 CFR 160.641
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 March 2021
Resolved 18 February 2021
Resolution: Vessel purchased wire splint for first aid kit. see documents.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 February 2021 Resolved
EACH LIFE JACKET MUST BE MARKED WITH TYPE 1 RETROREFLECTIVE MATERIAL. VESSEL'S LIFEJACKETS HAD WORN RETROREFLECTIVE MATERIAL. REPLACE RETROREFLECTIVE MATERIAL ON LIFEJACKETS. 46 CFR 185.604(H)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 March 2021
Resolved 17 February 2021
Resolution: VESSEL REPLACED RETROREFLECTIVE TAPE ON ALL LIFEJACKETS THAT HAD WORN RETROREFLECTIVE TAPE.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 24 February 2020 Resolved
Placards containing instructions for the donning and use of life jackets aboard vessel must be posted. Placard needs posted.
Action required: 10 - Deficiency Rectified
Resolved 24 February 2020
Resolution: Placards permanently posted.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 February 2020 Resolved
Display and distribution of a community service hotline telephone number for crewmember asistance. Post EAP hotline.
Action required: 10 - Deficiency Rectified
Resolved 24 February 2020
Resolution: EAP hotline permanently posted.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 February 2020 Resolved
No marine employer shall engage or employ an individual to serve as a crewmember unless the individual passes a chemical test. Have all employees pass chemical test.
Action required: 705 - Other - as specified
Resolved 20 April 2020
Resolution: Employee no longer works for the company all other members are enrolled in drug consortium.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 24 February 2020 Resolved
As appropiate for the intended voyage, a vessel must carry up to date CG light list, tide table, current table. Provide up to date publications.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 March 2020
Resolved 2 March 2020
Resolution: Provided necessary publications.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 25 February 2019 Resolved
The battery on the water light is expired. Each battery used in an item of lifesaving equipment must be replaced during an annual inspection if the expiration date has passed. Replace battery with a new battery like in kind.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2019
Resolved 11 March 2019
Resolution: Vessel owner replaced battery in kind.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 February 2019 Resolved
The retro reflective tape on the ring life buoy is worn. Each ring life buoy must be marked with Type II retro reflective material. Replace worn retro reflective tape on life rung buoy with like in kind.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2019
Resolved 11 March 2019
Resolution: Vessel owner replaced wore out retro tape on life ring buoy with new tape.
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 25 February 2019 Resolved
The Emergency Broadcast Placard was not on the Operator's Station. A durable placard must be posted next to all radiotelephone installations with the emergency broadcast instructions and information, specific to the individual vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2019
Resolved 11 March 2019
Resolution: Vessel owner place new Emergency Broadcast Placard on the Operator's Station.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 25 February 2019 Resolved
Vessel needs an Employee Assistance Program (EAP) which must include at least the following elements: Display and distribution of informational material:display and distribution of a community service hot-line telephone number. Vessel needs to post EAP program.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2019
Resolved 11 March 2019
Resolution: Vessel placed a new placard with its Employee Assistance Program on vessel.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 4 December 2017 Resolved
Lifejacket instruction placard does not match the lifejackets on board.
Due 6 December 2017
Resolved 6 December 2017
Resolution: Received photo showing proper donning placard was provided.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 4 December 2017 Resolved
Window in the door leading into the passenger accommodation is broken.
Due 6 December 2017
Resolved 6 December 2017
Resolution: Received photo showing the window was replaced
Engineering › Fuel Oil Service System › Piping
Issued 4 December 2017 Resolved
Portside fuel line to main engine needs to be secured with a more permanent material, in addition starboard exhaust needs to be re-bracketed.
Condition: Improper Installation
Due 6 December 2017
Resolved 6 December 2017
Resolution: Received documentation attesting to the replacement and repairs of both the fuel line and the exhaust bracket.
Lifesaving › Lifefloat › Serviceable
Issued 6 March 2017 Resolved
The vessel's life float was damaged on all four quarters and inm need of repair before the vessel can carry passengers on intended off shore route.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 March 2017
Resolved 8 March 2017
Resolution: Cleared [name withheld].
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 3 March 2017 Resolved
Replace lifebuoy light to lifebouy lanyard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 March 2017
Resolved 8 March 2017
Resolution: Cleared [name withheld]
Engineering › Diesel Engine (propulsion-direct drive) › Piston Rod
Issued 19 January 2017 Resolved
Prove proper operation of port side main engine. 46 CFR 182.05-1
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 January 2017
Resolved 30 January 2017
Resolution: Engine repaired and seatrials conducted.
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 2 December 2016 Resolved
Re seal shaft packing gland starboard side. Remove Temporary repair. 46 CFR 176.15-5
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 December 2016
Resolved 2 December 2016
Resolution: Both shaft packing glands were repacked.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 2 December 2016 Resolved
Re seal the overhead underneath the bow sprit in forward peak. 46 CFR 176.20-1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 December 2016
Resolved 9 January 2017
Resolution: Overhead in forward peak was resealed.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 2 December 2016 Resolved
Seal wire penetration through overhead in the accomadation space. 46 CFR 183.05-50
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 December 2016
Resolved 9 January 2017
Resolution: Wire penetrations in accommadation space was sealed.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 2 December 2016 Resolved
Repair/renew deck railing starboard side embarkation station. 46 CFR 177.35-1
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 December 2016
Resolved 9 January 2017
Resolution: Starboard side embarkation station deck rail was repaired.
Construction/Loadline › Hull › Stiffener
Issued 2 December 2016 Resolved
Repair longitudinal frame as marked, aft of port side engine in the machinery space. Provide repair proposal. 46 CFR 176.20-1(b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 December 2016
Resolved 9 January 2017
Resolution: Longitudinal frame was sistered.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 2 December 2016 Resolved
Re-label vessel's name and replace retro. 46 CFR 185.30-5(c)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 December 2016
Resolved 9 January 2017
Resolution: Life buoy was labeled with vessel name.
Engineering › Fuel Oil Service System › Valve
Issued 2 December 2016 Resolved
Properly mark emergency shutoff valves on deck. 46 CFR 185.30-20(a)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 December 2016
Resolved 9 January 2017
Resolution: Emergency shutoff valves labeled.
Fire Fighting › Remote Fuel Shutoff › General
Issued 8 February 2016 Resolved
Starboard fuel shutoff is inop.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 February 2016
Resolved 17 February 2016
Resolution: Def corrected.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 8 February 2016 Resolved
Vessel does not have a nautical chart.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 February 2016
Resolved 17 February 2016
Resolution: Def corrected.
Communications › Radio Communications › VHF Radiotelephone
Issued 8 February 2016 Resolved
VHF radio does not have vessel's MMSI programmed into DSC operation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 March 2016
Resolved 17 February 2016
Resolution: Def corrected.
Electrical › Electrical Distribution System (emergency) › Wiring
Issued 8 February 2016 Resolved
Dead end wires need to be removed or placed into junction box in E/R and lazarette.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 February 2016
Resolved 17 February 2016
Resolution: Def corrected.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 8 February 2016 Resolved
Replace clamp in port hose penetration on shaft.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 February 2016
Resolved 17 February 2016
Resolution: Def corrected.
Electrical › Electrical Distribution System (emergency) › Grounding Conductor
Issued 8 February 2016 Resolved
Replace bonding wires (03) in port side e/r.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 February 2016
Resolved 17 February 2016
Resolution: Def corrected.
Construction/Loadline › Structures › Superstructure
Issued 3 March 2014 Resolved
Repair canopy welds, to side under lifefloat.
Condition: Damaged By Earlier Event
Due 24 March 2014
Resolved 13 March 2014
Lifesaving › Lifebuoys › Serviceable
Issued 3 March 2014 Resolved
Replace/renew retroreflective tape on life ring.
Condition: Damaged By Earlier Event
Due 24 March 2014
Resolved 6 March 2014
Lifesaving › Lifefloat › Paddle
Issued 3 March 2014 Resolved
Provide 01 paddle for lifefloat.
Condition: Placed in Improper Service
Due 24 March 2014
Resolved 6 March 2014
Construction/Loadline › Structures › Superstructure
Issued 3 March 2014 Resolved
Repair canopy starboard side base fitting.
Condition: Improper/Lack of Maintenance
Due 24 March 2014
Resolved 13 March 2014
Lifesaving › Lifefloat › Serviceable
Issued 3 March 2014 Resolved
Have lifefloat commercially serviced. Repair torn pennants.
Condition: Improper/Lack of Maintenance
Due 24 March 2014
Resolved 13 March 2014
Resolution: Replaced lifefloat with new in kind.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 3 March 2014 Resolved
Replace/renew PFD's with new light/sounding devices.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 March 2014
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 3 March 2014 Resolved
Provide proof of enrolement in a drug consortium.
Condition: Invalid
Due 24 March 2014
Resolved 6 March 2014
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type 1
Issued 3 March 2014 Resolved
Properly close MSD tank and secure from venting in engine room.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 March 2014
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 3 March 2014 Resolved
Replace float switch for submersible pump.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 March 2014
Operations/Management › Navigation Safety › Proper Use of Navigation/Anchor Lights
Issued 3 March 2014 Resolved
Properly repair/renew stern light.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 March 2014
Electrical › Electric Generation Source (service) › Generator
Issued 9 January 2012 Resolved
Provide specifications for new SSG and old SSG, to include system drawings.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 January 2012
Resolution: Verified.
Electrical › Electric Generation Source (service) › Generator
Issued 9 January 2012 Resolved
Properly secure new SSG to deck frames w/ adequate hardware.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 January 2012
Resolution: Verified.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 9 January 2012 Resolved
Repair pre-engineered FFF shut-down for SSG.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 January 2012
Resolution: Verified.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 9 January 2012 Resolved
Repair visual and audible alarms on pre-engineered FFF system @ operating station.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 January 2012
Resolution: Verified.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 9 January 2012 Resolved
Register and mount new EPIRB.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 January 2012
Resolution: Verified.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 9 January 2012 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 January 2012
Resolution: Verified.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 9 January 2012 Resolved
Conduct underway safety drills.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 January 2012
Resolution: Witnessed.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 9 January 2012 Resolved
Renew expired (1-11) alcohol swabs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 January 2012
Resolution: Verified.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 9 January 2012 Resolved
Renew all (17) PML's on each Type 1 PFD. Current PML's DOM and EXP dates have been altered.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 January 2012
Resolution: Verified.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 24 January 2011 Resolved
Provide a proper USCG approved first aid kit as per the requlations in 46CFR Subchapter Q.
Action required: 705 - Other - as specified
Due 24 February 2011
Resolved 10 February 2011
Resolution: Owner provide a USCG approved first aid kit.
Communications › Radio Communications › EPIRB
Issued 24 January 2011 Resolved
Provide a replacement plastic key for safety on the vessel's EPIRB switch.
Action required: 705 - Other - as specified
Due 10 February 2011
Resolved 10 February 2011
Resolution: Owner had EPIRB servicing facility replace plastic safety tab.
Lifesaving › Lifefloat › Float Free
Issued 24 January 2011 Resolved
Provide proper mounting system for lifefloat. Lifefloat must be secure in mounts but also be able to float free.
Action required: 705 - Other - as specified
Due 24 February 2011
Resolved 10 February 2011
Resolution: Owner replaced mounting system on the bimini top w/ a proper float free configuration.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 24 January 2011 Resolved
Provide a separate stern light and masthead light as per the Navigation rules. >>>VESSEL RESTRICTED TO DAYTIME OPERATIONS UNTIL DEF CLEARED<<<
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 February 2011
Resolution: Owner installed the required lights as per the navigation rules.
Electrical › Lighting (service) › Lighting Fixture
Issued 18 January 2011 Resolved
Repair accomodation space overhead light in forward compartment.
Action required: 705 - Other - as specified
Due 24 February 2011
Resolved 10 February 2011
Resolution: Owner replaced bulb in light fixture.
Engineering › Sea-water System (primary cooling) › Piping
Issued 18 January 2011 Resolved
Renew & replace wasted stbd MDE raw water intake hose.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 February 2011
Resolved 10 February 2011
Resolution: Owner replaced wasted stbd MDE raw water intake hose w/ approved SAE hose.
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 1 March 2010 Resolved
Provide proof of Radio Safety Certificate.
Action required: 705 - Other - as specified
Due 1 April 2010
Resolved 29 March 2010
Resolution: Owner had a certified FCC technician check his radio installation and issue the vsl a Radio Safety Certificate.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 1 March 2010 Resolved
Provide lock on overboard discharge for sewage holding tank.
Action required: 705 - Other - as specified
Due 1 April 2010
Resolved 29 March 2010
Resolution: Owner purchased a lock for the overboard discharge valve.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 1 March 2010 Resolved
Provide watertight cover for anchor line opening leading to the fore peak.
Action required: 705 - Other - as specified
Due 1 April 2010
Resolved 29 March 2010
Resolution: The owner installed a new watertight cover.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 1 March 2010 Resolved
Provide most recent MIS report and pre-employment/ enrollment documentation for mate. Vessel can use alternate mate, if enrolled/documented in consortium, to carry passengers. Must notify OCMI of crew change.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 March 2010
Resolution: This 835 was cleared, another was issued for the vessel or company to complete a DAPI audit with in a month.
Engineering › Shafting/Propeller Arrangements › Stern Tube
Issued 1 March 2010 Resolved
Install proper hose clamps on shaft logs.
Action required: 705 - Other - as specified
Due 1 April 2010
Resolved 29 March 2010
Resolution: Owner installed new double hose clamps on both shaft logs.
Engineering › Diesel Engine (propulsion-direct drive) › Turbocharger
Issued 1 March 2010 Resolved
Permanently attach shut-down solienod to stb main engine.
Action required: 705 - Other - as specified
Due 1 April 2010
Resolved 29 March 2010
Resolution: Owner used a heli-coil to fix the mounting threads and re-installed the solienod.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 1 March 2010 Resolved
Renew dry-rotting flex hose on port and stbd exhaust (port fwd and stbd aft)
Action required: 705 - Other - as specified
Due 1 April 2010
Resolved 29 March 2010
Resolution: Owner replaced flex hose.
Construction/Loadline › Hull › Longitudinal Frame
Issued 1 March 2010 Resolved
Properly repair deck frame above port fuel tank. Provide repair proposal prior to repair. REPAIR PRIOR TO NEXT DRYDOCK.
Action required: 705 - Other - as specified
Due 5 March 2011
Resolved 29 March 2010
Resolution: Owner repaired the cut deck frame by installing a sister frame.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 1 March 2010 Resolved
Provide audible, visual, and override function for pre-engineered fire fighting system as per 181.420; configure shutdown feature to include both main engines & generator.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 March 2010
Resolution: Owner had a fire fighting equipment service company fix system and install override for the generator.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 1 March 2010 Resolved
Satisfactorily complete a drug and alcohol program (DAPI) audit for vessel or company.
Action required: 705 - Other - as specified
Due 27 May 2010
Resolved 3 June 2010
Resolution: Company sent Sector Jacksonville the missing items from the last DAPI audit. Company has succesfully completed a DAPI audit on this date.
Personnel › Manning/Qualifications › CPR Certified Personnel
Issued 6 January 2008 Resolved
Complete a CPR refresher course.
Action required: 705 - Other - as specified
Due 6 January 2008
Resolved 12 June 2008
Resolution: Course was completed
Engineering › Sea-water System (primary cooling) › Piping
Issued 6 December 2007 Resolved
Replace broken clamp on exhaust pipe.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 January 2008
Resolved 12 June 2008
Resolution: The clamp is replaced
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 6 December 2007 Resolved
Stencil vessel's name and replace retro tape.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 January 2008
Resolved 12 June 2008
Resolution: Stenciled and new tape.
Lifesaving › Lifefloat › Serviceable
Issued 4 December 2007 Resolved
Service or replace dry rotted float
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 December 2007
Resolution: Replaced
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 4 December 2007 Resolved
Repair the stern light.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 December 2007
Resolution: Light is repaired.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Remote Pulls
Issued 4 December 2007 Resolved
Service or repair the manual release.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 December 2007
Resolution: Release is working
Communications › Radio Communications › Radiotelephone Transceiver (2-4 MHz)
Issued 4 December 2007 Resolved
Service the single side band and ensure proper operation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 December 2007
Resolution: Single side band is working.
Engineering › Lubricating Oil Service System › Gauge
Issued 4 December 2007 Resolved
Repair the lube oil pressure gauge for the stbd engine at the operating station.
Action required: 705 - Other - as specified
Due 6 January 2008
Resolved 12 June 2008
Resolution: A new gauge was installed
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 8 March 2007 Resolved
Make all bulkhead penetrations airtight.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 April 2007
Resolved 5 April 2007
Resolution: All penetrations are sealed.
Engineering › Diesel Engine (auxiliary) › Crankshaft
Issued 8 March 2007 Resolved
Install a guard over the pulleys on the generator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 April 2007
Resolved 5 April 2007
Resolution: Guard is in stalled.
Navigation › Piloting/Steering › US Coast Pilot
Issued 8 March 2007 Resolved
Ensure current NAV. pubs are on board vessel.
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 April 2007
Resolved 5 April 2007
Resolution: Current pubs on board.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 8 March 2007 Resolved
Ensure proper operation of all NAV. lights.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 April 2007
Resolved 5 April 2007
Resolution: All NAV. lights working.
Documentation › Logs/Records › Logbook (official)
Issued 8 March 2007 Resolved
Provide logbook to capture training and drills.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 April 2007
Resolved 5 April 2007
Resolution: Logbook provided.
Documentation › Safety Management System › Emergency Drill/Exercise Programs
Issued 8 March 2007 Resolved
Provide and post emergency instructions list.
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 April 2007
Resolved 5 April 2007
Resolution: Instructions are posted.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 8 March 2007 Resolved
Post emergency broadcast placard.
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 April 2007
Resolved 5 April 2007
Resolution: Broadcast placard posted.
Communications › Radio Communications › EPIRB
Issued 8 March 2007 Resolved
Replace static release on the EPIRB
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 March 2007
Resolution: Replace with a new static release.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 8 March 2007 Resolved
Replace the line from the ring buoy to the light and repair holder for the light.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 March 2007
Resolution: The line for the ring buoy and the light was replaced. The holder for the light was repaired.
Lifesaving › Lifejacket/PFD (Type II) › Condition
Issued 8 March 2007 Resolved
Replace 4 adult lifejackets and 2 child lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 March 2007
Resolution: 4 new adult and 2 child lifejackets.
Lifesaving › Lifefloat › Float Free
Issued 8 March 2007 Resolved
Make lifefloat, float free and properly attach the tag line and the light.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 March 2007
Resolution: Lifefloat is properly stowed. The tagline and light are attached.
Electrical › Electric Supply System (service) › Cable
Issued 8 March 2007 Resolved
Remove all dead end cables.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 April 2007
Resolved 5 April 2007
Resolution: Cables removed.
Electrical › Lighting (service) › Lighting Fixture
Issued 8 March 2007 Resolved
Replace cover to the light fixtures.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 April 2007
Resolved 5 April 2007
Resolution: Fixtures replaced.
Engineering › Steering Gear System › Rudder
Issued 8 March 2007 Resolved
Tighten the packing gland on the port rudder post.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 April 2007
Resolved 5 April 2007
Resolution: The leak was stopped on the rudder post
Construction/Loadline › Structures › Superstructure
Issued 8 March 2007 Resolved
Repair broken weld on canopy frame.
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 April 2007
Resolved 5 April 2007
Resolution: The frame was repaired.
Stability › Water on Deck › General
Issued 8 March 2007 Resolved
Remove covers from the scuppers.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 April 2007
Resolved 5 April 2007
Resolution: The covers were removed.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 15 March 2005 Resolved
Application has been made to Documentation Center but original has not been received.
Due 15 April 2005
Resolved 1 March 2006
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 2 March 2005 Resolved
Provide 46 CFR 166-199 (Subchapter T)
Due 1 April 2005
Resolved 24 March 2005
Resolution: RCVD RECIEPT ON NEW CHARTS & PUBS
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 2 March 2005 Resolved
No audible alarm for low lube oil on stbd. engine.
Due 15 April 2005
Resolved 24 March 2005
Resolution: VESSEL REPAIRED ALARM
Lifesaving › Lifebuoys
Issued 8 March 2004 Resolved
RENEW RING LIFE BUOY AND LIFELINE IAW 46CFR180.70.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 March 2004
Resolved 29 March 2004
Personnel › Certificates/Documents/Licenses › Certificate, CPR Course Completion
Issued 8 March 2004 Resolved
PROVIDE RED CROSS FIRST AID / CPR CARDS FOR 50% OF CREW. LEGACY COMPONENT DESC: Certificate, CPR Course Completion
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 April 2004
Resolved 2 March 2005
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 8 March 2004 Resolved
ENSURE CREW IS ENROLLED IN A DRUG TESTING PROGRAM IAW 46CFR16.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 March 2004
Resolved 2 March 2005
Navigation › Piloting/Steering
Issued 8 March 2004 Resolved
PROVIDE CURRENT NAV PUBS (USCP, LIGHT LIST, CHARTS, AND NAVRULES) IAW 46CFR184.420. LEGACY COMPONENT DESC: Marine Charts
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 March 2004
Resolved 29 March 2004
Operations/Management › Drills/Instruction
Issued 8 March 2004 Resolved
PROVIDE EMERGENCY BROADCAST PLACARD.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 March 2004
Resolved 29 March 2004
Pollution Prevention/Response › Prevention Equipment
Issued 8 March 2004 Resolved
PROVE PROPER OPERATION OF MSD TO INCLUDE "Y" VALVE AND MASERATOR. LEGACY COMPONENT DESC: Marine Sanitation Device, Type III
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 March 2004
Resolved 29 March 2004
Lifesaving › Lifejacket/PFD (General)
Issued 8 March 2004 Resolved
RENEW AND POST LIFEJACKET DONNING PLACARD IAW 46CFR185.516.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 March 2004
Resolved 29 March 2004
Fire Fighting › Miscellaneous Items
Issued 8 March 2004 Resolved
PROVIDE CLOSURE DEVICES FOR ENGINE ROOM VENTILATION WHEN FIXED FIREFIGHTING SYSTEM IS ACTIVATED. PROVIDE SHUTOFF FOR GENERATOR WHEN FIXED FIGHTING SYSTEM ACTIVATES.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 April 2004
Resolved 29 March 2004
Construction/Loadline › Structures
Issued 8 March 2004 Resolved
PROVIDE PLAN FOR RENEWING DECK SUPPORT IN MAIN SALON.
Action required: 705 - Other - as specified
Due 9 April 2004
Resolved 29 March 2004
Resolution: Deck strength members renewed as original.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 8 March 2004 Resolved
RENEW THE PORT ENGINE EXHAUST SUPPORT AND THE OVERBOARD BILGE HANDLE ON STARBOARD SIDE. REMOVE OR RENEW LIGHT OVER PORT ENGINE AND PROVIDE HARNESS FOR WIRES IN THE PORT VOID FORWARD OF THE ENGINE ROOM.
Action required: 705 - Other - as specified
Due 9 April 2004
Resolved 29 March 2004
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 19 December 2002 Resolved
Fire Extinguishing system does not met req of part 181. 46 CFR LEGACY COMPONENT DESC: Operating Controls
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 January 2003
Resolved 30 January 2003
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 19 December 2002 Resolved
Portable Ext agent pressure gauge ext and lead wire seal missing. LEGACY COMPONENT DESC: Pressure
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 January 2003
Resolved 30 January 2003
Operations/Management › Navigation Safety
Issued 19 December 2002 Resolved
Vessel missing various charts, Nav Rules, Current Tide table LEGACY COMPONENT DESC: Carriage of Charts and Publications
Condition: Unknown
Due 19 January 2003
Resolved 30 January 2003
Communications › Radio Communications
Issued 19 December 2002 Resolved
SSB radio inoper LEGACY COMPONENT DESC: Radiotelephone Transceiver (2-27.5 MHz)
Condition: Improper/Lack of Maintenance
Due 19 January 2003
Resolved 30 January 2003
Accommodation/Occupational Safety › Medical/First Aid
Issued 19 December 2002 Resolved
Vessel Frist aid Kit Missing item LEGACY COMPONENT DESC: Medicine Chest
Condition: Improper/Lack of Maintenance
Due 19 January 2003
Resolved 30 January 2003
Electrical
Issued 8 March 1999 Resolved
PROVE PROPER OPERATION OF THE ONAN GENERATOR.
Condition: Unknown
Due 11 March 1999
Resolved 11 March 1999
Lifesaving
Issued 9 March 1998 Resolved
PROVIDE RESCUE LADDER FOR PERSON OVERBOARD.
Condition: Unknown
Due 9 March 1998
Resolved 9 March 1998
Lifesaving
Issued 16 December 1994 Resolved
PROVIDE ONE ADDITIONAL RED FLARE AND TWO ADDITIONAL ORANGE SMOKE PYROTECHNICS PRIOR TO CARRYING PASSENGERS ON BOARD._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 December 1994
Resolved 16 December 1994
Documentation
Issued 6 January 1992 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 6 January 1992
Resolved 6 January 1992
Electrical
Issued 18 December 1990 Resolved
REPLACE WIRING FROM GENERATOR TO MAIN BREAKER IN SWITCHBOARD WITH #8 AWG ORGREATER PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 18 December 1990
Resolved 18 December 1990
Accommodation/Occupational Safety
Issued 18 December 1990 Resolved
PROVIDE A SIGN STATING SEWAGE OVERBOARD VALVE MUST REMAIN CLOSED WHILE OPERATING WITHIN TERRITORIAL WATERS PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 18 December 1990
Resolved 18 December 1990
Fire Fighting
Issued 18 December 1990 Resolved
PROVIDE ADEQUATE LENGTHS OF HOSE FOR HAND BILGE/FIRE PUMP PRIOR TO CARRYINGPASSENGERS.
Condition: Unknown
Due 18 December 1990
Resolved 18 December 1990
Electrical
Issued 18 December 1990 Resolved
PROVIDE AN ADDITIONAL NAMEPLATE FRO S/S GENERATOR SPECIFYING DERATED CAPACITY (64 KW, 52.8 AMP MAX) AS REQUIRED BY 46 CFR 183.10-5F(2) PRIOR TO CARRYING PASSENGERS._x001C_ _x001C_
Condition: Unknown
Due 18 December 1990
Resolved 18 December 1990
Accommodation/Occupational Safety
Issued 18 December 1990 Resolved
PROVIDE A MEANS TO LOCK MSD TANK OVERBOARD VALVE IN THE CLOSED POSITION PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 18 December 1990
Resolved 18 December 1990
Lifesaving
Issued 18 December 1990 Resolved
PROPERLY MOUNT LIFERAFT PRIOR TO CARRING PASSENGERS.
Condition: Unknown
Due 18 December 1990
Resolved 18 December 1990
Documentation
Issued 18 December 1990 Resolved
PROVIDE FCC CERTIFICATE. VESSEL IS LIMITED TO NOT MORE THAN 1000 FT FROM SHORE UNTIL COMPLETED.
Condition: Unknown
Due 18 December 1990
Resolved 18 December 1990
Lifesaving
Issued 18 December 1990 Resolved
PROVIDE WATERTIGHT CONTAINER FOR FLARES PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 18 December 1990
Resolved 18 December 1990
Documentation
Issued 18 December 1990 Resolved
POST EMERGENCY CHECKOFF LIST PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 18 December 1990
Resolved 18 December 1990
Lifesaving
Issued 18 December 1990 Resolved
PROVIDE EMERGENCY FLASHLIGHT PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 18 December 1990
Resolved 18 December 1990
Construction/Loadline
Issued 18 December 1990 Resolved
MAKE DOOR TO CABIN WEATHERTIGHT PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 18 December 1990
Resolved 18 December 1990

Casualty record · 1

13 July 2014Routine · role: Involved in a Marine Casualty · activity 4922216
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.