← All vessels
ENDLESS SUMMER III
Passenger (Inspected) · Passenger Ship class · Built 1990s · USCG Southeast District (CGD-SE) · Other hulls named ENDLESS SUMMER III
ENDLESS SUMMER III is a 1990 passenger vessel (inspected). The Coast Guard has recorded 61 inspections since 1990, most recently in February 2026, along with 143 deficiencies, 7 operational controls and 1 casualty investigation in 2014.
Records from 1990 to 2026. Most recent: inspection, 19 February 2026.
- Built
- 1990
- Last inspected
- 19 February 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 143 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2014
Identity
970286
WDC8789
356427
Flag
UNITED STATES
367093080
Maury page id
psix-356427
Inspections, by type
…with no type recorded3
Years with a record
33 calendar years (1990–2026)
The 61 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)40.7 ft × 13.2 ft × 8.2 ft
Registered tonnagegross 29 / net 23
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMICHAEL FITZ CUSTOM BOATS · NAPLES, FL, UNITED STATES · built 1990
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portST AUGUSTINE, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 12 February 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it29 - Simplified, Gross Ton
23 - Simplified, Net Ton
23 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDJ2743MMSI 367093080 · active · compulsorily equipped · granted 8 November 2016, expires 8 November 2026
WDC8789MMSI 367093080 · expired · compulsorily equipped · granted 15 February 2006, cancelled 16 April 2016
WAP8291MMSI not assigned · expired · compulsorily equipped · granted 11 October 1995, cancelled 4 February 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 61
19 February 2026
Annual Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8305316
21 March 2025
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8097406
13 December 2024
Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8047126
22 June 2024
In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7940103
22 February 2024
Deficiency Check · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7868727
12 December 2023
Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7838095
22 November 2022
Drydock Exam · Internal Structural Exam · COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7600589
4 March 2022
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7403822
17 February 2021
Annual Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7136476
1 February 2021
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7134532
28 December 2020
Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7112731
20 April 2020
Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6941352
12 February 2020
Deficiency Check · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6908039
25 February 2019
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6631553
26 March 2018
Administrative Inspection · In-Service Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6416210
4 December 2017
DAPI Audit · COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6315389
3 March 2017
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6098476
19 January 2017
In-Service Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6073663
28 November 2016
Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6048769
8 February 2016
Deficiency Check · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5808298
3 March 2014
Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4809148
9 January 2012
DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4219679
1 August 2011
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4131965
18 January 2011
Examination of Repairs · Annual Inspection · Deficiency Check · DAPI Audit · Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3955817
26 February 2010
DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3686409
24 February 2009
Internal Structural Exam · Drydock Exam · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3422276
4 June 2008
Administrative Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3226917
5 December 2007
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3110208
4 December 2007
COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3098509
8 March 2007
Annual Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2868954
1 March 2006
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2589092
2 March 2005
Re-Inspection · Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2302719
5 April 2004
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2037806
8 March 2004
Annual Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2022801
1 April 2003
Hull Examination · Internal Structural Exam
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1769369
19 December 2002
COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1724996
26 March 2002
Periodic Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1600545
27 March 2001
Hull Examination · Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1384707
24 December 1999
COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1376010
20 May 1999
Type not recorded
No type recorded · USCGC PEA ISLAND (WPB 1347) · USCG Southeast District (CGD-SE) · Activity 1508519
17 May 1999
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 65652
8 March 1999
Re-Inspection · Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1471547
8 April 1998
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 791145
9 March 1998
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 784744
11 April 1997
Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1099158
17 December 1996
COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1092807
22 January 1996
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1185336
3 January 1996
Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 879215
28 December 1994
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 850964
16 December 1994
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 845263
17 December 1993
COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 848999
2 December 1993
Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 847743
11 January 1993
Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1133561
3 March 1992
Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1270069
27 February 1992
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 952575
6 January 1992
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1265037
18 December 1991
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 952016
29 July 1991
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1000723
26 December 1990
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1224406
18 December 1990
Hull Examination · Initial Certification · Initial Construction-Excluding Oversight
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 926204
13 December 1990
Plan Review "T" Boat
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 900004
Deficiency record · 143
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 19 February 2026
Resolved
A pre-engineered fixed gas fire extinguishing system must: be installed in accordance with manufacturer's instruction. Door in between engine and steering space was not secure.
46 CFR 181.420(a)(4)
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 19 February 2026
Resolved
Sternlight shall be visible from at least 2 miles. Sternlight inoperable.
46 CFR 183.420
33 CFR 83.22(b)(iii)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 19 February 2026
Resolved
A vessel must be provided with 1 portable hand bilge pump. Vessel does not have a portable hand bilge pump.
46 CFR 182.520(a)
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 February 2026
Resolved
All cable/ wire must be installed with metal supports spaced not more than 24 inches apart. Electrical wire on overhead space was hanging from ceiling.
46 CFR 183.340(b)(4)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 19 February 2026
Resolved
A penetration in a watertight bulkhead must be as high as far inboard in the bulkhead as practicable, and made watertight. Fwd engine room bulkhead penetration is not watertight.
46 CFR 179.320(c)
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 19 February 2026
Resolved
A vessel must comply with FCC/ 47 CFR 80. Vessel does not have a station license or radio telephone certs. on board.
46 CFR 184.502
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 25 March 2025
Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. Liferaft quick release gear inoperable.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 25 March 2025
Resolved
All escape hatches and other emergency exits must be marked on both sides "EMERGENCY EXIT, KEEP CLEAR." Escape hatch not marked.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 March 2025
Resolved
At each inspection test pre-engineered fire protection equipment. Means of securing air not present.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 21 March 2025
Resolved
Your vessel must undergo an annual inspection within 3 months before or after each anniversary date. You failed to have an annual inspection within the 3 months before or after you anniversary date of 30 November 2024.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 19 December 2024
Resolved
The owner shall make a vessel available for dry dock exams and internal structural exam. The following worklist items need to be completed prior to credit dry dock.
A. Replace starboard rudder key.
B. Renew fiberglass on starboard aft quarter.
C. Replace port and starboard cutlass bearing.
D. Renew fiberglass in way of bow.
E. Replace starboard shaft.
F. Replace two broken thru hole valves in port pump room.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 June 2024
Resolved
The owner, charterer, managing operator, or master of must keep a correct list of the names of all persons that embark on and disembark from the vessel and the list shall be available to the Coast Guard upon request. Vessel was unable to provide list of crew and passengers to the Coast Guard upon request. Vessel owner must provide Coast with updated process on how passenger lists are recorded and ready upon request.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 February 2024
Resolved
Ring life buoy light is incorrect type. Replace with correct light.
Restricted to daytime operations until replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 22 February 2024
Resolved
Hydrostatic release on IBA is expired. Replace with valid hydrostatic release.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 February 2024
Resolved
Bimini top has temporary repairs. Weld to make repairs permanent.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 February 2024
Resolved
No portable hand fire pump onboard. Obtain fire buckets to meet requirement.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 February 2024
Resolved
Wiring in port forward salon is taped to pipe/conduit. Install proper wire supports.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 2 December 2022
Resolved
Rails shall be installed near the periphery of all weatherdecks accessible to passengers and crew. Bimini stanchon and handrails are loose or cracked.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 2 December 2022
Resolved
Flexible hose designed for use with a hose clamps may be installed with two clamps at both ends of the hose. Saltwater hoses on main diesle engines and generators are missing second clamp.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 22 November 2022
Resolved
A vessel must carry one floating waterlight. Waterlight has a crack in shell.
10 - Safety of Navigation › N/A - No Subsystem › Life-saving signals
Issued 17 February 2021
Resolved
ALL VESSELS SHALL CARRY APPROPRIATE NUMBER PYROTECHNIC DISTRESS SIGNALS. VESSEL DID NOT HAVE APPROPRIATE NUMBER OF DISTRESS SIGNALS. PROVIDE APPROPRIATE NUMBER OF DISTRESS SIGNALS.
46 CFR 180.35-5
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 February 2021
Resolved
PROVISIONS SHALL BE MADE TO PREVENT THE ADMISSION OF AIR INTO THE SPACE PROTECTED. VESSELS HAD BULKHEAD PRENETRATIONS ON THE FORWARD BULKHEAD IN THE ENGINE SPACE THAT WERE NOT AIR TIGHT. MAKE AIRE TIGHT WITH APPROPRIATE MATERIAL.
46 CFR 181.20-35
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 17 February 2021
Resolved
A VESSEL MUST CARRY APPROVED FIRST AID KIT. VESSEL'S FIRST AID KIT DID NOT HAVE ALL REQUIRED CONTENTS. PROCURE WIRE SPLINT FOR FIRST AID KIT.
46 CFR 184.710
46 CFR 160.641
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 February 2021
Resolved
EACH LIFE JACKET MUST BE MARKED WITH TYPE 1 RETROREFLECTIVE MATERIAL. VESSEL'S LIFEJACKETS HAD WORN RETROREFLECTIVE MATERIAL. REPLACE RETROREFLECTIVE MATERIAL ON LIFEJACKETS.
46 CFR 185.604(H)
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 24 February 2020
Resolved
Placards containing instructions for the donning and use of life jackets aboard vessel must be posted. Placard needs posted.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 February 2020
Resolved
Display and distribution of a community service hotline telephone number for crewmember asistance. Post EAP hotline.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 February 2020
Resolved
No marine employer shall engage or employ an individual to serve as a crewmember unless the individual passes a chemical test. Have all employees pass chemical test.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 24 February 2020
Resolved
As appropiate for the intended voyage, a vessel must carry up to date CG light list, tide table, current table. Provide up to date publications.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 25 February 2019
Resolved
The battery on the water light is expired. Each battery used in an item of lifesaving equipment must be replaced during an annual inspection if the expiration date has passed. Replace battery with a new battery like in kind.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 February 2019
Resolved
The retro reflective tape on the ring life buoy is worn. Each ring life buoy must be marked with Type II retro reflective material. Replace worn retro reflective tape on life rung buoy with like in kind.
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 25 February 2019
Resolved
The Emergency Broadcast Placard was not on the Operator's Station. A durable placard must be posted next to all radiotelephone installations with the emergency broadcast instructions and information, specific to the individual vessel.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 25 February 2019
Resolved
Vessel needs an Employee Assistance Program (EAP) which must include at least the following elements: Display and distribution of informational material:display and distribution of a community service hot-line telephone number. Vessel needs to post EAP program.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 4 December 2017
Resolved
Lifejacket instruction placard does not match the lifejackets on board.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 4 December 2017
Resolved
Window in the door leading into the passenger accommodation is broken.
Engineering › Fuel Oil Service System › Piping
Issued 4 December 2017
Resolved
Portside fuel line to main engine needs to be secured with a more permanent material, in addition starboard exhaust needs to be re-bracketed.
Lifesaving › Lifefloat › Serviceable
Issued 6 March 2017
Resolved
The vessel's life float was damaged on all four quarters and inm need of repair before the vessel can carry passengers on intended off shore route.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 3 March 2017
Resolved
Replace lifebuoy light to lifebouy lanyard.
Engineering › Diesel Engine (propulsion-direct drive) › Piston Rod
Issued 19 January 2017
Resolved
Prove proper operation of port side main engine. 46 CFR 182.05-1
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 2 December 2016
Resolved
Re seal shaft packing gland starboard side. Remove Temporary repair. 46 CFR 176.15-5
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 2 December 2016
Resolved
Re seal the overhead underneath the bow sprit in forward peak. 46 CFR 176.20-1
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 2 December 2016
Resolved
Seal wire penetration through overhead in the accomadation space. 46 CFR 183.05-50
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 2 December 2016
Resolved
Repair/renew deck railing starboard side embarkation station. 46 CFR 177.35-1
Construction/Loadline › Hull › Stiffener
Issued 2 December 2016
Resolved
Repair longitudinal frame as marked, aft of port side engine in the machinery space. Provide repair proposal. 46 CFR 176.20-1(b)
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 2 December 2016
Resolved
Re-label vessel's name and replace retro. 46 CFR 185.30-5(c)
Engineering › Fuel Oil Service System › Valve
Issued 2 December 2016
Resolved
Properly mark emergency shutoff valves on deck. 46 CFR 185.30-20(a)
Fire Fighting › Remote Fuel Shutoff › General
Issued 8 February 2016
Resolved
Starboard fuel shutoff is inop.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 8 February 2016
Resolved
Vessel does not have a nautical chart.
Communications › Radio Communications › VHF Radiotelephone
Issued 8 February 2016
Resolved
VHF radio does not have vessel's MMSI programmed into DSC operation.
Electrical › Electrical Distribution System (emergency) › Wiring
Issued 8 February 2016
Resolved
Dead end wires need to be removed or placed into junction box in E/R and lazarette.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 8 February 2016
Resolved
Replace clamp in port hose penetration on shaft.
Electrical › Electrical Distribution System (emergency) › Grounding Conductor
Issued 8 February 2016
Resolved
Replace bonding wires (03) in port side e/r.
Construction/Loadline › Structures › Superstructure
Issued 3 March 2014
Resolved
Repair canopy welds, to side under lifefloat.
Lifesaving › Lifebuoys › Serviceable
Issued 3 March 2014
Resolved
Replace/renew retroreflective tape on life ring.
Lifesaving › Lifefloat › Paddle
Issued 3 March 2014
Resolved
Provide 01 paddle for lifefloat.
Construction/Loadline › Structures › Superstructure
Issued 3 March 2014
Resolved
Repair canopy starboard side base fitting.
Lifesaving › Lifefloat › Serviceable
Issued 3 March 2014
Resolved
Have lifefloat commercially serviced. Repair torn pennants.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 3 March 2014
Resolved
Replace/renew PFD's with new light/sounding devices.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 3 March 2014
Resolved
Provide proof of enrolement in a drug consortium.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type 1
Issued 3 March 2014
Resolved
Properly close MSD tank and secure from venting in engine room.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 3 March 2014
Resolved
Replace float switch for submersible pump.
Operations/Management › Navigation Safety › Proper Use of Navigation/Anchor Lights
Issued 3 March 2014
Resolved
Properly repair/renew stern light.
Electrical › Electric Generation Source (service) › Generator
Issued 9 January 2012
Resolved
Provide specifications for new SSG and old SSG, to include system drawings.
Electrical › Electric Generation Source (service) › Generator
Issued 9 January 2012
Resolved
Properly secure new SSG to deck frames w/ adequate hardware.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 9 January 2012
Resolved
Repair pre-engineered FFF shut-down for SSG.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 9 January 2012
Resolved
Repair visual and audible alarms on pre-engineered FFF system @ operating station.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 9 January 2012
Resolved
Register and mount new EPIRB.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 9 January 2012
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 9 January 2012
Resolved
Conduct underway safety drills.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 9 January 2012
Resolved
Renew expired (1-11) alcohol swabs.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 9 January 2012
Resolved
Renew all (17) PML's on each Type 1 PFD. Current PML's DOM and EXP dates have been altered.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 24 January 2011
Resolved
Provide a proper USCG approved first aid kit as per the requlations in 46CFR Subchapter Q.
Communications › Radio Communications › EPIRB
Issued 24 January 2011
Resolved
Provide a replacement plastic key for safety on the vessel's EPIRB switch.
Lifesaving › Lifefloat › Float Free
Issued 24 January 2011
Resolved
Provide proper mounting system for lifefloat. Lifefloat must be secure in mounts but also be able to float free.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 24 January 2011
Resolved
Provide a separate stern light and masthead light as per the Navigation rules.
>>>VESSEL RESTRICTED TO DAYTIME OPERATIONS UNTIL DEF CLEARED<<<
Electrical › Lighting (service) › Lighting Fixture
Issued 18 January 2011
Resolved
Repair accomodation space overhead light in forward compartment.
Engineering › Sea-water System (primary cooling) › Piping
Issued 18 January 2011
Resolved
Renew & replace wasted stbd MDE raw water intake hose.
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 1 March 2010
Resolved
Provide proof of Radio Safety Certificate.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 1 March 2010
Resolved
Provide lock on overboard discharge for sewage holding tank.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 1 March 2010
Resolved
Provide watertight cover for anchor line opening leading to the fore peak.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 1 March 2010
Resolved
Provide most recent MIS report and pre-employment/ enrollment documentation for mate. Vessel can use alternate mate, if enrolled/documented in consortium, to carry passengers. Must notify OCMI of crew change.
Engineering › Shafting/Propeller Arrangements › Stern Tube
Issued 1 March 2010
Resolved
Install proper hose clamps on shaft logs.
Engineering › Diesel Engine (propulsion-direct drive) › Turbocharger
Issued 1 March 2010
Resolved
Permanently attach shut-down solienod to stb main engine.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 1 March 2010
Resolved
Renew dry-rotting flex hose on port and stbd exhaust (port fwd and stbd aft)
Construction/Loadline › Hull › Longitudinal Frame
Issued 1 March 2010
Resolved
Properly repair deck frame above port fuel tank. Provide repair proposal prior to repair. REPAIR PRIOR TO NEXT DRYDOCK.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 1 March 2010
Resolved
Provide audible, visual, and override function for pre-engineered fire fighting system as per 181.420; configure shutdown feature to include both main engines & generator.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 1 March 2010
Resolved
Satisfactorily complete a drug and alcohol program (DAPI) audit for vessel or company.
Personnel › Manning/Qualifications › CPR Certified Personnel
Issued 6 January 2008
Resolved
Complete a CPR refresher course.
Engineering › Sea-water System (primary cooling) › Piping
Issued 6 December 2007
Resolved
Replace broken clamp on exhaust pipe.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 6 December 2007
Resolved
Stencil vessel's name and replace retro tape.
Lifesaving › Lifefloat › Serviceable
Issued 4 December 2007
Resolved
Service or replace dry rotted float
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 4 December 2007
Resolved
Repair the stern light.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Remote Pulls
Issued 4 December 2007
Resolved
Service or repair the manual release.
Communications › Radio Communications › Radiotelephone Transceiver (2-4 MHz)
Issued 4 December 2007
Resolved
Service the single side band and ensure proper operation
Engineering › Lubricating Oil Service System › Gauge
Issued 4 December 2007
Resolved
Repair the lube oil pressure gauge for the stbd engine at the operating station.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 8 March 2007
Resolved
Make all bulkhead penetrations airtight.
Engineering › Diesel Engine (auxiliary) › Crankshaft
Issued 8 March 2007
Resolved
Install a guard over the pulleys on the generator.
Navigation › Piloting/Steering › US Coast Pilot
Issued 8 March 2007
Resolved
Ensure current NAV. pubs are on board vessel.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 8 March 2007
Resolved
Ensure proper operation of all NAV. lights.
Documentation › Logs/Records › Logbook (official)
Issued 8 March 2007
Resolved
Provide logbook to capture training and drills.
Documentation › Safety Management System › Emergency Drill/Exercise Programs
Issued 8 March 2007
Resolved
Provide and post emergency instructions list.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 8 March 2007
Resolved
Post emergency broadcast placard.
Communications › Radio Communications › EPIRB
Issued 8 March 2007
Resolved
Replace static release on the EPIRB
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 8 March 2007
Resolved
Replace the line from the ring buoy to the light and repair holder for the light.
Lifesaving › Lifejacket/PFD (Type II) › Condition
Issued 8 March 2007
Resolved
Replace 4 adult lifejackets and 2 child lifejackets.
Lifesaving › Lifefloat › Float Free
Issued 8 March 2007
Resolved
Make lifefloat, float free and properly attach the tag line and the light.
Electrical › Electric Supply System (service) › Cable
Issued 8 March 2007
Resolved
Remove all dead end cables.
Electrical › Lighting (service) › Lighting Fixture
Issued 8 March 2007
Resolved
Replace cover to the light fixtures.
Engineering › Steering Gear System › Rudder
Issued 8 March 2007
Resolved
Tighten the packing gland on the port rudder post.
Construction/Loadline › Structures › Superstructure
Issued 8 March 2007
Resolved
Repair broken weld on canopy frame.
Stability › Water on Deck › General
Issued 8 March 2007
Resolved
Remove covers from the scuppers.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 15 March 2005
Resolved
Application has been made to Documentation Center but original has not been received.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 2 March 2005
Resolved
Provide 46 CFR 166-199 (Subchapter T)
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 2 March 2005
Resolved
No audible alarm for low lube oil on stbd. engine.
Lifesaving › Lifebuoys
Issued 8 March 2004
Resolved
RENEW RING LIFE BUOY AND LIFELINE IAW 46CFR180.70.
Personnel › Certificates/Documents/Licenses › Certificate, CPR Course Completion
Issued 8 March 2004
Resolved
PROVIDE RED CROSS FIRST AID / CPR CARDS FOR 50% OF CREW. LEGACY COMPONENT DESC: Certificate, CPR Course Completion
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 8 March 2004
Resolved
ENSURE CREW IS ENROLLED IN A DRUG TESTING PROGRAM IAW 46CFR16.
Navigation › Piloting/Steering
Issued 8 March 2004
Resolved
PROVIDE CURRENT NAV PUBS (USCP, LIGHT LIST, CHARTS, AND NAVRULES) IAW 46CFR184.420. LEGACY COMPONENT DESC: Marine Charts
Operations/Management › Drills/Instruction
Issued 8 March 2004
Resolved
PROVIDE EMERGENCY BROADCAST PLACARD.
Pollution Prevention/Response › Prevention Equipment
Issued 8 March 2004
Resolved
PROVE PROPER OPERATION OF MSD TO INCLUDE "Y" VALVE AND MASERATOR. LEGACY COMPONENT DESC: Marine Sanitation Device, Type III
Lifesaving › Lifejacket/PFD (General)
Issued 8 March 2004
Resolved
RENEW AND POST LIFEJACKET DONNING PLACARD IAW 46CFR185.516.
Fire Fighting › Miscellaneous Items
Issued 8 March 2004
Resolved
PROVIDE CLOSURE DEVICES FOR ENGINE ROOM VENTILATION WHEN FIXED FIREFIGHTING SYSTEM IS ACTIVATED. PROVIDE SHUTOFF FOR GENERATOR WHEN FIXED FIGHTING SYSTEM ACTIVATES.
Construction/Loadline › Structures
Issued 8 March 2004
Resolved
PROVIDE PLAN FOR RENEWING DECK SUPPORT IN MAIN SALON.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 8 March 2004
Resolved
RENEW THE PORT ENGINE EXHAUST SUPPORT AND THE OVERBOARD BILGE HANDLE ON STARBOARD SIDE. REMOVE OR RENEW LIGHT OVER PORT ENGINE AND PROVIDE HARNESS FOR WIRES IN THE PORT VOID FORWARD OF THE ENGINE ROOM.
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 19 December 2002
Resolved
Fire Extinguishing system does not met req of part 181. 46 CFR LEGACY COMPONENT DESC: Operating Controls
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 19 December 2002
Resolved
Portable Ext agent pressure gauge ext and lead wire seal missing. LEGACY COMPONENT DESC: Pressure
Operations/Management › Navigation Safety
Issued 19 December 2002
Resolved
Vessel missing various charts, Nav Rules, Current Tide table LEGACY COMPONENT DESC: Carriage of Charts and Publications
Communications › Radio Communications
Issued 19 December 2002
Resolved
SSB radio inoper LEGACY COMPONENT DESC: Radiotelephone Transceiver (2-27.5 MHz)
Accommodation/Occupational Safety › Medical/First Aid
Issued 19 December 2002
Resolved
Vessel Frist aid Kit Missing item LEGACY COMPONENT DESC: Medicine Chest
Electrical
Issued 8 March 1999
Resolved
PROVE PROPER OPERATION OF THE ONAN GENERATOR.
Lifesaving
Issued 9 March 1998
Resolved
PROVIDE RESCUE LADDER FOR PERSON OVERBOARD.
Lifesaving
Issued 16 December 1994
Resolved
PROVIDE ONE ADDITIONAL RED FLARE AND TWO ADDITIONAL ORANGE SMOKE PYROTECHNICS PRIOR TO CARRYING PASSENGERS ON BOARD._x001C_ _x001C_ _x001C_
Documentation
Issued 6 January 1992
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Electrical
Issued 18 December 1990
Resolved
REPLACE WIRING FROM GENERATOR TO MAIN BREAKER IN SWITCHBOARD WITH #8 AWG ORGREATER PRIOR TO CARRYING PASSENGERS.
Accommodation/Occupational Safety
Issued 18 December 1990
Resolved
PROVIDE A SIGN STATING SEWAGE OVERBOARD VALVE MUST REMAIN CLOSED WHILE OPERATING WITHIN TERRITORIAL WATERS PRIOR TO CARRYING PASSENGERS.
Fire Fighting
Issued 18 December 1990
Resolved
PROVIDE ADEQUATE LENGTHS OF HOSE FOR HAND BILGE/FIRE PUMP PRIOR TO CARRYINGPASSENGERS.
Electrical
Issued 18 December 1990
Resolved
PROVIDE AN ADDITIONAL NAMEPLATE FRO S/S GENERATOR SPECIFYING DERATED CAPACITY (64 KW, 52.8 AMP MAX) AS REQUIRED BY 46 CFR 183.10-5F(2) PRIOR TO CARRYING PASSENGERS._x001C_ _x001C_
Accommodation/Occupational Safety
Issued 18 December 1990
Resolved
PROVIDE A MEANS TO LOCK MSD TANK OVERBOARD VALVE IN THE CLOSED POSITION PRIOR TO CARRYING PASSENGERS.
Lifesaving
Issued 18 December 1990
Resolved
PROPERLY MOUNT LIFERAFT PRIOR TO CARRING PASSENGERS.
Documentation
Issued 18 December 1990
Resolved
PROVIDE FCC CERTIFICATE. VESSEL IS LIMITED TO NOT MORE THAN 1000 FT FROM SHORE UNTIL COMPLETED.
Lifesaving
Issued 18 December 1990
Resolved
PROVIDE WATERTIGHT CONTAINER FOR FLARES PRIOR TO CARRYING PASSENGERS.
Documentation
Issued 18 December 1990
Resolved
POST EMERGENCY CHECKOFF LIST PRIOR TO CARRYING PASSENGERS.
Lifesaving
Issued 18 December 1990
Resolved
PROVIDE EMERGENCY FLASHLIGHT PRIOR TO CARRYING PASSENGERS.
Construction/Loadline
Issued 18 December 1990
Resolved
MAKE DOOR TO CABIN WEATHERTIGHT PRIOR TO CARRYING PASSENGERS.
Casualty record · 1
13 July 2014Routine · role: Involved in a Marine Casualty · activity 4922216
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.