Records from 2014 to 2026. Most recent: inspection, 19 February 2026.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 19 February 2026
Resolved
A pre-engineered fixed gas fire extinguishing system must: be installed in accordance with manufacturer's instruction. Door in between engine and steering space was not secure.
46 CFR 181.420(a)(4)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 March 2026
Resolution: Door secured.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 19 February 2026
Resolved
Sternlight shall be visible from at least 2 miles. Sternlight inoperable.
46 CFR 183.420
33 CFR 83.22(b)(iii)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 March 2026
Resolved 2 March 2026
Resolution: Stern light operable.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 19 February 2026
Resolved
A vessel must be provided with 1 portable hand bilge pump. Vessel does not have a portable hand bilge pump.
46 CFR 182.520(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 March 2026
Resolved 2 March 2026
Resolution: Hand bilge pump provided.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 February 2026
Resolved
All cable/ wire must be installed with metal supports spaced not more than 24 inches apart. Electrical wire on overhead space was hanging from ceiling.
46 CFR 183.340(b)(4)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 March 2026
Resolved 2 March 2026
Resolution: Cable secured.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 19 February 2026
Resolved
A penetration in a watertight bulkhead must be as high as far inboard in the bulkhead as practicable, and made watertight. Fwd engine room bulkhead penetration is not watertight.
46 CFR 179.320(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 March 2026
Resolved 2 March 2026
Resolution: Engine room bulkhead penetration made watertight.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 19 February 2026
Resolved
A vessel must comply with FCC/ 47 CFR 80. Vessel does not have a station license or radio telephone certs. on board.
46 CFR 184.502
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 March 2026
Resolved 6 March 2026
Resolution: Received photo of Radio Safety Certificate.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 25 March 2025
Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. Liferaft quick release gear inoperable.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2025
Resolved 3 April 2025
Resolution: Received, reviewed and accpted evidence correcting the deficiency.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 25 March 2025
Resolved
All escape hatches and other emergency exits must be marked on both sides "EMERGENCY EXIT, KEEP CLEAR." Escape hatch not marked.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 April 2025
Resolved 3 April 2025
Resolution: Received, reviewed and accpted evidence correcting the deficiency.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 March 2025
Resolved
At each inspection test pre-engineered fire protection equipment. Means of securing air not present.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 April 2025
Resolved 4 April 2025
Resolution: USCG MI verified deficiency has been corrected properly.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 21 March 2025
Resolved
Your vessel must undergo an annual inspection within 3 months before or after each anniversary date. You failed to have an annual inspection within the 3 months before or after you anniversary date of 30 November 2024.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 March 2025
Resolution: USCG MIs completed a satisfactory Annual Inspection.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 19 December 2024
Resolved
The owner shall make a vessel available for dry dock exams and internal structural exam. The following worklist items need to be completed prior to credit dry dock.
A. Replace starboard rudder key.
B. Renew fiberglass on starboard aft quarter.
C. Replace port and starboard cutlass bearing.
D. Renew fiberglass in way of bow.
E. Replace starboard shaft.
F. Replace two broken thru hole valves in port pump room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 January 2025
Resolved 3 January 2025
Resolution: All worklist items rectified.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 June 2024
Resolved
The owner, charterer, managing operator, or master of must keep a correct list of the names of all persons that embark on and disembark from the vessel and the list shall be available to the Coast Guard upon request. Vessel was unable to provide list of crew and passengers to the Coast Guard upon request. Vessel owner must provide Coast with updated process on how passenger lists are recorded and ready upon request.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 June 2024
Resolved 26 June 2024
Resolution: Passenger list with names will be kept by vessel captain and owner ashore for every voyage.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 February 2024
Resolved
Ring life buoy light is incorrect type. Replace with correct light.
Restricted to daytime operations until replaced.
Action required: 705 - Other - as specified
Resolved 29 February 2024
Resolution: New approved light was installed.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 22 February 2024
Resolved
Hydrostatic release on IBA is expired. Replace with valid hydrostatic release.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 February 2024
Resolved 28 February 2024
Resolution: Sent pictures of new hydrostatic release installed.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 February 2024
Resolved
Bimini top has temporary repairs. Weld to make repairs permanent.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 March 2024
Resolved 3 April 2024
Resolution: Welded broken components back together.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 February 2024
Resolved
No portable hand fire pump onboard. Obtain fire buckets to meet requirement.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 March 2024
Resolved 28 February 2024
Resolution: Obtained buckets.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 February 2024
Resolved
Wiring in port forward salon is taped to pipe/conduit. Install proper wire supports.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 March 2024
Resolved 28 February 2024
Resolution: Secured wiring using metal bands and removed tape.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 2 December 2022
Resolved
Rails shall be installed near the periphery of all weatherdecks accessible to passengers and crew. Bimini stanchon and handrails are loose or cracked.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2023
Resolved 12 December 2023
Resolution: Verified rail installation.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 2 December 2022
Resolved
Flexible hose designed for use with a hose clamps may be installed with two clamps at both ends of the hose. Saltwater hoses on main diesle engines and generators are missing second clamp.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 December 2022
Resolved 8 December 2022
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 22 November 2022
Resolved
A vessel must carry one floating waterlight. Waterlight has a crack in shell.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 January 2023
Resolved 8 December 2022
10 - Safety of Navigation › N/A - No Subsystem › Life-saving signals
Issued 17 February 2021
Resolved
ALL VESSELS SHALL CARRY APPROPRIATE NUMBER PYROTECHNIC DISTRESS SIGNALS. VESSEL DID NOT HAVE APPROPRIATE NUMBER OF DISTRESS SIGNALS. PROVIDE APPROPRIATE NUMBER OF DISTRESS SIGNALS.
46 CFR 180.35-5
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 February 2021
Resolution: VESSEL PURCHASED REQUIRED NUMBER OF DISTRESS SIGNALS PRIOR TO INSPECTORS DEPARTING.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 February 2021
Resolved
PROVISIONS SHALL BE MADE TO PREVENT THE ADMISSION OF AIR INTO THE SPACE PROTECTED. VESSELS HAD BULKHEAD PRENETRATIONS ON THE FORWARD BULKHEAD IN THE ENGINE SPACE THAT WERE NOT AIR TIGHT. MAKE AIRE TIGHT WITH APPROPRIATE MATERIAL.
46 CFR 181.20-35
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 March 2021
Resolved 18 February 2021
Resolution: VESSEL MADE BULKHEAD PENETRATIONS AIR TIGHT WITH APPROVED MATERIAL.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 17 February 2021
Resolved
A VESSEL MUST CARRY APPROVED FIRST AID KIT. VESSEL'S FIRST AID KIT DID NOT HAVE ALL REQUIRED CONTENTS. PROCURE WIRE SPLINT FOR FIRST AID KIT.
46 CFR 184.710
46 CFR 160.641
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 March 2021
Resolved 18 February 2021
Resolution: Vessel purchased wire splint for first aid kit. see documents.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 February 2021
Resolved
EACH LIFE JACKET MUST BE MARKED WITH TYPE 1 RETROREFLECTIVE MATERIAL. VESSEL'S LIFEJACKETS HAD WORN RETROREFLECTIVE MATERIAL. REPLACE RETROREFLECTIVE MATERIAL ON LIFEJACKETS.
46 CFR 185.604(H)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 March 2021
Resolved 17 February 2021
Resolution: VESSEL REPLACED RETROREFLECTIVE TAPE ON ALL LIFEJACKETS THAT HAD WORN RETROREFLECTIVE TAPE.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 24 February 2020
Resolved
Placards containing instructions for the donning and use of life jackets aboard vessel must be posted. Placard needs posted.
Action required: 10 - Deficiency Rectified
Resolved 24 February 2020
Resolution: Placards permanently posted.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 February 2020
Resolved
Display and distribution of a community service hotline telephone number for crewmember asistance. Post EAP hotline.
Action required: 10 - Deficiency Rectified
Resolved 24 February 2020
Resolution: EAP hotline permanently posted.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 February 2020
Resolved
No marine employer shall engage or employ an individual to serve as a crewmember unless the individual passes a chemical test. Have all employees pass chemical test.
Action required: 705 - Other - as specified
Resolved 20 April 2020
Resolution: Employee no longer works for the company all other members are enrolled in drug consortium.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 24 February 2020
Resolved
As appropiate for the intended voyage, a vessel must carry up to date CG light list, tide table, current table. Provide up to date publications.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 March 2020
Resolved 2 March 2020
Resolution: Provided necessary publications.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 25 February 2019
Resolved
The battery on the water light is expired. Each battery used in an item of lifesaving equipment must be replaced during an annual inspection if the expiration date has passed. Replace battery with a new battery like in kind.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2019
Resolved 11 March 2019
Resolution: Vessel owner replaced battery in kind.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 February 2019
Resolved
The retro reflective tape on the ring life buoy is worn. Each ring life buoy must be marked with Type II retro reflective material. Replace worn retro reflective tape on life rung buoy with like in kind.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2019
Resolved 11 March 2019
Resolution: Vessel owner replaced wore out retro tape on life ring buoy with new tape.
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 25 February 2019
Resolved
The Emergency Broadcast Placard was not on the Operator's Station. A durable placard must be posted next to all radiotelephone installations with the emergency broadcast instructions and information, specific to the individual vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2019
Resolved 11 March 2019
Resolution: Vessel owner place new Emergency Broadcast Placard on the Operator's Station.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 25 February 2019
Resolved
Vessel needs an Employee Assistance Program (EAP) which must include at least the following elements: Display and distribution of informational material:display and distribution of a community service hot-line telephone number. Vessel needs to post EAP program.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2019
Resolved 11 March 2019
Resolution: Vessel placed a new placard with its Employee Assistance Program on vessel.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 4 December 2017
Resolved
Lifejacket instruction placard does not match the lifejackets on board.
Due 6 December 2017
Resolved 6 December 2017
Resolution: Received photo showing proper donning placard was provided.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 4 December 2017
Resolved
Window in the door leading into the passenger accommodation is broken.
Due 6 December 2017
Resolved 6 December 2017
Resolution: Received photo showing the window was replaced
Engineering › Fuel Oil Service System › Piping
Issued 4 December 2017
Resolved
Portside fuel line to main engine needs to be secured with a more permanent material, in addition starboard exhaust needs to be re-bracketed.
Condition: Improper Installation
Due 6 December 2017
Resolved 6 December 2017
Resolution: Received documentation attesting to the replacement and repairs of both the fuel line and the exhaust bracket.
Lifesaving › Lifefloat › Serviceable
Issued 6 March 2017
Resolved
The vessel's life float was damaged on all four quarters and inm need of repair before the vessel can carry passengers on intended off shore route.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 March 2017
Resolved 8 March 2017
Resolution: Cleared [name withheld].
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 3 March 2017
Resolved
Replace lifebuoy light to lifebouy lanyard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 March 2017
Resolved 8 March 2017
Resolution: Cleared [name withheld]
Engineering › Diesel Engine (propulsion-direct drive) › Piston Rod
Issued 19 January 2017
Resolved
Prove proper operation of port side main engine. 46 CFR 182.05-1
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 January 2017
Resolved 30 January 2017
Resolution: Engine repaired and seatrials conducted.
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 2 December 2016
Resolved
Re seal shaft packing gland starboard side. Remove Temporary repair. 46 CFR 176.15-5
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 December 2016
Resolved 2 December 2016
Resolution: Both shaft packing glands were repacked.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 2 December 2016
Resolved
Re seal the overhead underneath the bow sprit in forward peak. 46 CFR 176.20-1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 December 2016
Resolved 9 January 2017
Resolution: Overhead in forward peak was resealed.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 2 December 2016
Resolved
Seal wire penetration through overhead in the accomadation space. 46 CFR 183.05-50
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 December 2016
Resolved 9 January 2017
Resolution: Wire penetrations in accommadation space was sealed.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 2 December 2016
Resolved
Repair/renew deck railing starboard side embarkation station. 46 CFR 177.35-1
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 December 2016
Resolved 9 January 2017
Resolution: Starboard side embarkation station deck rail was repaired.
Construction/Loadline › Hull › Stiffener
Issued 2 December 2016
Resolved
Repair longitudinal frame as marked, aft of port side engine in the machinery space. Provide repair proposal. 46 CFR 176.20-1(b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 December 2016
Resolved 9 January 2017
Resolution: Longitudinal frame was sistered.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 2 December 2016
Resolved
Re-label vessel's name and replace retro. 46 CFR 185.30-5(c)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 December 2016
Resolved 9 January 2017
Resolution: Life buoy was labeled with vessel name.
Engineering › Fuel Oil Service System › Valve
Issued 2 December 2016
Resolved
Properly mark emergency shutoff valves on deck. 46 CFR 185.30-20(a)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 December 2016
Resolved 9 January 2017
Resolution: Emergency shutoff valves labeled.
Fire Fighting › Remote Fuel Shutoff › General
Issued 8 February 2016
Resolved
Starboard fuel shutoff is inop.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 February 2016
Resolved 17 February 2016
Resolution: Def corrected.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 8 February 2016
Resolved
Vessel does not have a nautical chart.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 February 2016
Resolved 17 February 2016
Resolution: Def corrected.
Communications › Radio Communications › VHF Radiotelephone
Issued 8 February 2016
Resolved
VHF radio does not have vessel's MMSI programmed into DSC operation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 March 2016
Resolved 17 February 2016
Resolution: Def corrected.
Electrical › Electrical Distribution System (emergency) › Wiring
Issued 8 February 2016
Resolved
Dead end wires need to be removed or placed into junction box in E/R and lazarette.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 February 2016
Resolved 17 February 2016
Resolution: Def corrected.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 8 February 2016
Resolved
Replace clamp in port hose penetration on shaft.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 February 2016
Resolved 17 February 2016
Resolution: Def corrected.
Electrical › Electrical Distribution System (emergency) › Grounding Conductor
Issued 8 February 2016
Resolved
Replace bonding wires (03) in port side e/r.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 February 2016
Resolved 17 February 2016
Resolution: Def corrected.