Records from 1990 to 2025. Most recent: inspection, 10 April 2025.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 54
10 April 2025
PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8109296
23 September 2024
PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8007512
20 February 2024
PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7867383
4 April 2021
Explosive Handling Operation-Commercial
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7165652
1 March 2021
Explosive Handling Operation-Commercial
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7154057
26 January 2021
PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7130579
25 January 2021
Explosive Handling Operation-Commercial
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7127416
3 March 2020
PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6919606
2 March 2020
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6918761
25 February 2019
ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6631507
17 July 2018
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6482491
5 February 2018
ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6349458
27 March 2017
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6112116
18 November 2016
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 6040613
30 January 2016
Type not recorded
No type recorded · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 5807382
29 January 2016
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5805912
20 October 2014
ISPS II Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5000970
9 January 2012
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4219334
20 September 2011
PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 4149918
21 September 2010
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3854530
20 September 2010
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3854498
19 September 2010
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3854956
19 September 2010
Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3855568
22 February 2010
Ballast Water Examination · PII Safety Exam · ISPS III Exam
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3681100
28 July 2009
Random ISPS/MTSA/PSC
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3549530
23 March 2009
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3438746
24 December 2008
Random ISPS/MTSA/PSC · Ballast Water Examination · ISPS III Exam
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3384600
21 February 2008
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3151266
22 January 2008
PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3134085
22 February 2007
STCW 95 Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2876918
23 January 2007
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2860287
20 January 2006
ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2569854
3 November 2004
NPV Safety Exam
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2234356
12 July 2004
ISPS II Exam
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2130897
10 September 2002
Annual Inspection · Security Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 1674411
29 January 2002
Security Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 1481921
3 January 2001
Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 285579
30 August 2000
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 281498
27 September 1999
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 432870
2 September 1998
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 420393
19 May 1997
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 403893
13 May 1996
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 391199
12 May 1995
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 378341
18 December 1994
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 373409
18 December 1994
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1155242
27 June 1994
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 368146
27 June 1994
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 826996
25 October 1993
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 521971
21 October 1993
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 362024
15 December 1992
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 467089
5 October 1991
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 346335
5 October 1991
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 347148
10 April 1991
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 484242
30 October 1990
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 340037
Operations/Management › Ballast Water Managment › Alternative Management Method
Issued 18 November 2016
Resolved
The Master, Owner, Operator, Agent or person in charge of a vessel equipped with ballast tanks that operates in the waters of the U.S. must employ one of the following ballast water management methods described in 33 CFR 151.2025.
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 18 December 2016
Resolved 27 March 2017
Resolution: Vessel received extension letter for BWM from USCG
Engineering › Fuel Oil Service System › Discharge Strainer
Issued 19 September 2010
Resolved
Prove proper operation of Main Engine Automatic Fuel Striner Backflush Assembly.
Action required: 705 - Other - as specified
Due 22 September 2010
Resolved 21 September 2010
Engineering › Sea-water System (primary cooling) › Sea Chest
Issued 22 February 2010
Resolved
Temporary patch found on strainer for main seawater pump # 1, jeopardizing watertight integrity of the vessel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 February 2010
Resolution: Received a class surveyor report that attests to the repair on the seawater pump
Engineering › Fuel Oil Service System › Piping
Issued 22 February 2010
Resolved
Insulation of piping in oil purifier room saturated with oil and missing in some areas, creating a fire and safety hazard.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 23 February 2010
Resolution: Received class surveyor report that attests to the repairs of the lagging
Stability › Watertight Integrity › General
Issued 22 February 2010
Resolved
A hole has been cut in the main deck to allow for the removal of the ship's shaft generator, jeopardizing the watertight integrity of the vessel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 February 2010
Resolution: Received a class surveyor report that attests to the temporary repairs made to the deck
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 23 January 2007
Resolved
Upon Inspection of the vessel's generators, it was noted that the shielding for the generators exhaust was corroded. Class must attest to the proper repair/installation of shielding replacement. SOLAS 74/78 CHP II-1/26.1
Action required: 705 - Other - as specified
Due 22 February 2007
Resolved 7 February 2007
Resolution: Received class report attesting to the proper repair of the shielding for the generators exhaust system.
Unknown
Issued 30 August 2000
Resolved
Leak in piping; forward of engine room fire pump. SOLAS 74/78 II-I/21_x001C_ Repair prior to next U.S. port after sailing foreign.
Condition: Unknown
Due 3 January 2001
Resolved 3 January 2001
Engineering
Issued 30 August 2000
Resolved
Several flame screens not adequately installed or are in need of repair._x001C_ SOLAS 74/78 II-2/15_x001C_ Repair prior to next U.S. port after sailing foreign.
Condition: Unknown
Due 3 January 2001
Resolved 3 January 2001
Lifesaving
Issued 2 September 1998
Resolved
TWELVE (12) ROCKET PARACHUTE FLARES ON BRIDGE ARE EXPIRED.
Condition: Unknown
Due 14 September 1998
Resolved 14 September 1998