MAURY USCG vessel records Sign in
← All vessels

NOMBEI

NOMBEI is a 1990 passenger vessel (inspected). The Coast Guard has recorded 52 inspections since 1990, most recently in July 2020, along with 152 deficiencies — 1 with no resolution recorded — and 2 operational controls.

Records from 1990 to 2020. Most recent: inspection, 13 July 2020.

Built
1990
Last inspected
13 July 2020
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7WCZ3352
356682
Flag
UNITED STATES
367412190
Maury page id
psix-356682

Inspections, by type

…with no type recorded6
Years with a record 24 calendar years (1990–2020)
The 52 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)42.9 ft × 13.0 ft × 7.5 ft
Registered tonnagegross 20 / net 18
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderHSING HANG INDUSTRIES · TAIPEI, TAIWAN · built 1990
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeSail (Distinct Keel)
Hull configurationMonohull
Hailing portSAIPAN, MP
Trade endorsementsRegistry
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it20 - Simplified, Gross Ton
18 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDL2350MMSI 367412190 · active · compulsorily equipped · granted 30 August 2019, expires 30 August 2029
WCZ3352MMSI 367412190 · expired · compulsorily equipped · granted 29 May 2009, cancelled 17 August 2019
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 52

13 July 2020 Administrative Inspection
Administrative · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7009088
10 February 2019 Annual Inspection · Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6623322
21 November 2018 Drydock Extension
Administrative · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6584659
26 July 2018 Type not recorded
No type recorded · USCGC KISKA (WPB 1336) · USCG Oceania District (CGD-O) · Activity 6493705
11 July 2018 Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6476073
31 October 2017 Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6298028
19 July 2017 Type not recorded
No type recorded · USCGC WASHINGTON (WPB 1331) · USCG Oceania District (CGD-O) · Activity 6279991
12 April 2017 Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6123274
17 October 2016 Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6023519
28 August 2016 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 5985631
14 January 2009 Type not recorded
No type recorded · USCGC WASHINGTON (WPB 1331) · USCG Oceania District (CGD-O) · Activity 3400617
8 August 2008 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 3292472
16 July 2008 Drydock Exam
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 3269350
6 June 2007 Type not recorded
No type recorded · USCGC WASHINGTON (WPB 1331) · USCG Oceania District (CGD-O) · Activity 2956314
14 May 2007 COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2929328
26 March 2007 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2894812
15 June 2006 Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2680221
2 January 2006 Annual Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2559071
23 December 2004 Type not recorded
No type recorded · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2263845
3 August 2004 Annual Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2154299
30 June 2004 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2039748
12 September 2003 Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 1902930
11 July 2003 Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 1844276
5 July 2003 Annual Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 1835269
17 May 2002 Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 1618124
10 May 2002 COI Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 1615589
30 March 2002 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 1599206
27 February 2001 Administrative
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1062837
17 May 2000 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 818089
26 April 2000 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 817364
27 March 2000 COI Inspection · Hull Examination · MARPOL Annex V Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1393350
8 May 1999 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 796626
5 March 1999 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1395130
27 February 1999 Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 801389
27 May 1998 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1128931
16 May 1998 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 790709
16 May 1998 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1125048
30 March 1998 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 787884
30 March 1998 Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1364613
22 February 1998 Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 779531
27 February 1997 COI Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1101870
18 February 1996 Hull Examination · Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1080560
14 March 1995 Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 853490
27 February 1995 Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 863523
23 February 1994 COI Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 854610
29 April 1993 Hull Examination · Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1142703
22 December 1992 Administrative
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1137557
23 July 1992 Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 951266
27 September 1991 Administrative
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 934651
2 August 1991 Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1246345
28 March 1991 COI Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 935029
28 September 1990 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 901330

Deficiency record · 152

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 13 July 2020 No resolution recorded
Vessel inspected under subcahpter T may not operate without having on board a valid USCG COI. Vessel annual inspection is overdue.
Action required: 701 - Prior to carriage of passengers/cargo
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 11 July 2018 Resolved
Operator must have valid FCC operator license as required by 47CFR80. Provide proof of valid FCC operator license.
Due 25 July 2018
Resolved 25 July 2018
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 11 July 2018 Resolved
vessel must carry adequate pubs and chart for intended route as required by 46 CFR 185.20-35. Provide missing local notice to mariners, light list, tide table, charts, coastal pilot and nav rules.
Due 25 July 2018
Resolved 25 July 2018
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 July 2018 Resolved
Life jackets must have at least 31 sq. in. of type I retro-reflective material as required by 46 CFR 180.25-25. Install required size of type I retro-reflective material.
Due 25 July 2018
Resolved 25 July 2018
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 11 July 2018 Resolved
Engine room must be cleared of fire hazard as required by 46 CFR 25-50. Repair all oil leaks from engine and remove oil in the bilges.
Due 25 July 2018
Resolved 25 July 2018
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 11 July 2018 Resolved
Show proper operation of engine room ventilation as required by 46CFR182.20-35.
Due 25 July 2018
Resolved 25 July 2018
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 11 July 2018 Resolved
Hatches exposed to weather must be water tight as required by 46CFR171.124. Repair damaged forward hatch.
Due 25 July 2018
Resolved 25 July 2018
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 11 July 2018 Resolved
Escape hatches shall be marked on both side " EMERGENCY EXIT, KEEP CLEAR". Marked the forward hatch.
Due 25 July 2018
Resolved 25 July 2018
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 11 July 2018 Resolved
Pre-engineered FGFE must be serviced annually as required by 46CFR181.20-1. Provide proof of annual service conduct on Fire-boy system.
Due 25 July 2018
Resolved 25 July 2018
Engineering › Diesel Engine (propulsion-reduction gear) › Cylinder Liner
Issued 31 October 2017 Resolved
Damaged #1 cylinder liner. Conduct repairs I.A.W. engine manufacture instructions. Coast guard M.I. will attest the complete repairs and conduct operational test prior to vessel carrying passenger.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 December 2017
Resolution: Completed satisfactory repairs.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 12 April 2017 Resolved
Vessel must have deck rails to withstand weight of 200lbs as required by 46 CFR 177.35-1. Repair damaged FRP around rail post - port side forward.
Due 20 April 2017
Resolved 13 December 2017
Operations/Management › Equipment Service/Testing › EPIRB
Issued 12 April 2017 Resolved
EPIRB battery and hydrostatic release must not be expired as required by 46 CFR 185.25-20. Replace expired battery & hydrostatic release or change route to not more than 3 miles from shore.
Due 20 April 2017
Resolved 12 April 2017
Resolution: Owner decided to remove EPIRB from vessel and requested for change of route to not more than 3NM from shore.
Documentation › Logs/Records › Logbook (official)
Issued 12 April 2017 Resolved
Emergency training must be logged as required by 185.25-10. Update training log.
Due 20 April 2017
Resolved 12 April 2017
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 12 April 2017 Resolved
Vessel must have portable electric light as required by 46 CFR 184.30-1.
Due 20 April 2017
Resolved 12 April 2017
Stability › Watertight Integrity › Weathertight Enclosure
Issued 12 April 2017 Resolved
All escape hatches must be marked " EMERGENCY EXIT, KEEP CLEAR" as required by 46 CFR 185.30-15. Marked forward hatch with 2 inches letter.
Due 20 April 2017
Resolved 12 April 2017
Engineering › Diesel Engine (propulsion-reduction gear) › Injector (fuel injection)
Issued 12 April 2017 Resolved
All hazardouse conditions must be corrected as required by 46 CFR 176.25-50. Found #4 fuel injector on STBD engine leaking fuel.
Due 20 April 2017
Resolved 12 April 2017
Lifesaving › Lifefloat › Serviceable
Issued 28 August 2016 Resolved
Lifesaving equipments not serviceable conditions must be repair IAW manufacture procedures or replace as required by 46 CFR 176.808. Life float with several damage areas to the outer layer must be repair in accordance with manufacture procedures or be replace prior to operate beyond 3 NM from shore.
Due 15 September 2016
Resolved 13 December 2017
Resolution: Vessel owner request to change route to not more than (03) NM from shore. LF was removed from vessel.
Lifesaving › Lifefloat › Paddle
Issued 28 August 2016 Resolved
Name of the vessel must be marked clearly legible letters on each life float paddle as required by 46 CFR 185.604 (g). Re-marked faded vessel name on the paddles.
Due 15 September 2016
Resolved 30 August 2016
Operations/Management › Equipment Service/Testing › EPIRB
Issued 28 August 2016 Resolved
Vessel operates beyond 3NM from coastline must have Catagory 1, 406 MHz EPIRB, to automatically float free and activated as required by 46 CFR 180.64. Install EPIRB with up-to-date NOAA registration and battery.
Due 15 September 2016
Resolved 30 August 2016
Engineering › Fuel Oil Service System › Filter
Issued 28 August 2016 Resolved
Fuel filter must be fitted with steel bowl as required by 46 CFR 182.455. Install manufacture design steel bowl on RACOR fuel filters for main engines.
Due 15 September 2016
Resolved 30 August 2016
Engineering › Diesel Engine (propulsion-reduction gear) › Pump, High Pressure (fuel injection)
Issued 28 August 2016 Resolved
All potential fire hazards must be corrected as required by 46 CFR 176.830. Repair fuel leak from STBD engine fuel injection pump.
Due 15 September 2016
Resolved 30 August 2016
Electrical › Electric Supply System (service) › Battery Installation
Issued 28 August 2016 Resolved
Battery tray must be clear of any type of liquids as required by 46 CFR 183.350. Remove standing liquids in battery tray.
Due 15 September 2016
Resolved 30 August 2016
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 28 August 2016 Resolved
Deck railing must be able to withstand a point load of 200 LBS applied at any direction as required by 46 CFR 177.900. Repair lose forward port deck railing.
Due 15 September 2016
Resolved 30 August 2016
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 8 August 2008 Resolved
Properly label location and quantity of child size life jackets.
Action required: 705 - Other - as specified
Due 22 August 2008
Resolved 18 September 2008
Personnel › Training › First Aid/CPR
Issued 8 August 2008 Resolved
Provide CPR/First Aid training to 50% of deckhands as per NVIC 1-91.
Action required: 705 - Other - as specified
Due 22 September 2008
Resolved 18 September 2008
Operations/Management › Equipment Service/Testing › EPIRB
Issued 8 August 2008 Resolved
Properly log monthly EPIRB test.
Action required: 705 - Other - as specified
Due 22 August 2008
Resolved 18 September 2008
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 8 August 2008 Resolved
Make permanent repairs to both port & starboard deck rails from amidships and forward to support 200 lb load.
Action required: 705 - Other - as specified
Due 22 August 2008
Resolved 18 September 2008
Engineering › Bilge Water Management System › Pump
Issued 8 August 2008 Resolved
Secure forward bilge pump to prevent movement.
Action required: 705 - Other - as specified
Due 22 August 2008
Resolved 18 September 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 May 2007 Resolved
Found ground wire in way of starboard side engine room not connected. Re-connect ground wire.
Due 21 May 2007
Resolved 29 May 2007
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 14 May 2007 Resolved
Found fixed fire fighting system overdue for annual sevicing. Prove annual servicing has been completed.
Due 21 May 2007
Resolved 29 May 2007
Navigation › Piloting/Steering › Marine Charts
Issued 14 May 2007 Resolved
Found vessel missing navigation charts. Prove current and corrected charts are on board vessel.
Due 21 May 2007
Resolved 29 May 2007
Navigation › Piloting/Steering › Magnetic Compass
Issued 14 May 2007 Resolved
Found magnetic compass not illuminated. Prove compass can be illuminated. Vessel limited to daylight operations until corrected.
Due 21 May 2007
Resolved 29 May 2007
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 14 May 2007 Resolved
Found port side deck rail loose and with temporary repairs. Make permanent repairs to deck rail.
Due 21 May 2007
Resolved 29 May 2007
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 14 May 2007 Resolved
Found starboard side deck rail loose. Make permanent repairs to deck rail.
Due 21 May 2007
Resolved 29 May 2007
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 14 May 2007 Resolved
Found upper deck rails with temporary repairs. Make permanent repairs to deck rails.
Due 21 May 2007
Resolved 29 May 2007
Lifesaving › Lifefloat › Paddle
Issued 14 May 2007 Resolved
Found life float paddles not labeled with vessel name. Label paddles.
Due 21 May 2007
Resolved 29 May 2007
Fire Fighting › Remote Fuel Shutoff › General
Issued 14 May 2007 Resolved
Found remote fuel shutoff for engines not properly operating. Prove proper operations of remote.
Due 21 May 2007
Resolved 29 May 2007
Fire Fighting › Means of Escape › Doorways
Issued 14 May 2007 Resolved
Found handle for door not properly operating. Make repairs to door handle.
Due 21 May 2007
Resolved 29 May 2007
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 14 May 2007 Resolved
Found port side exhaust piping supported with a wire. Make permanent repairs.
Due 21 May 2007
Resolved 29 May 2007
Fire Fighting › Fire Hydrants › Condition
Issued 14 May 2007 Resolved
Found fresh water piping on fantail cracked. Make permanent repairs.
Due 21 May 2007
Resolved 29 May 2007
Engineering › Freshwater System (jacketwater cooling) › Sensor
Issued 14 May 2007 Resolved
Found starboard engine water temp gauge not properly operating. Prove proper operation of gauges.
Due 21 May 2007
Resolved 29 May 2007
Personnel › Manning/Qualifications › CPR Certified Personnel
Issued 2 January 2006 Resolved
Found crew not 50% CPR qualified. Prove 50% CPR qualified crew.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 February 2006
Resolved 15 June 2006
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 2 January 2006 Resolved
Found no annual servicing of fixed extinguishing system. Prove proper fixed extinguishing servicing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 February 2006
Resolved 15 June 2006
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 2 January 2006 Resolved
Found vessel missing current training logbook, lifesaving equipment maintenance records and bridge log. Prove proper logbooks and maintenance records.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 February 2006
Resolved 15 June 2006
Construction/Loadline › Penetrations › Gasket
Issued 2 January 2006 Resolved
Found port light missing deadlight cover and leaking. Repair or replace port light gasket and install deadlight cover.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 February 2006
Resolved 15 June 2006
Lifesaving › Lifefloat › Painter
Issued 2 January 2006 Resolved
Found lifefloat painter dry rotted. Replace painter.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 February 2006
Resolved 15 June 2006
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 2 January 2006 Resolved
Found lifebuoy missing retro reflective material and not properly marked. Repair or replace lifebuoy.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 February 2006
Resolved 15 June 2006
Engineering › Fuel Oil Service System › Valve
Issued 2 January 2006 Resolved
Found fuel tank valves and reach rods broken. Repair or replace valves and reach rods.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 February 2006
Resolved 15 June 2006
Engineering › Diesel Engine (propulsion-direct drive) › Spark Arrestor (exhaust)
Issued 2 January 2006 Resolved
Found port and starboard exhaust piping with temporary repairs. Properly repair or replace pipes.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 February 2006
Resolved 15 June 2006
Electrical › Lighting (service) › Lighting Fixture
Issued 2 January 2006 Resolved
Found missing light cover in way of stern house door. Repair or replace light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 February 2006
Resolved 15 June 2006
Electrical › Lighting (service) › Lighting Fixture
Issued 2 January 2006 Resolved
Found main cabin light not operational. Repair or replace all non operational lighting fixtures.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 February 2006
Resolved 15 June 2006
Electrical › Lighting (emergency) › Lighting Fixture
Issued 2 January 2006 Resolved
Found emergency light not operational. Repair or replace light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 February 2006
Resolved 15 June 2006
Accommodation/Occupational Safety › Ventilation › General
Issued 2 January 2006 Resolved
Found engine room ducting not made of rigid materials. Replace with rigid materials.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 February 2006
Resolved 15 June 2006
Engineering › Bilge Water Management System › Not Operational
Issued 2 January 2006 Resolved
Found the stern visual high level bilge indicator not operational. Repair or replace alarm.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 February 2006
Resolved 15 June 2006
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 3 August 2004 Resolved
OVER-RIDE SWITCHES OPERATE OPPOSITE OF MARKED POSITIONS.
Condition: Improper/Lack of Maintenance
Due 3 September 2004
Resolved 23 December 2004
Resolution: COMPLETED.
Navigation › Piloting/Steering › US Coast Pilot
Issued 3 August 2004 Resolved
UIPDATE U.S. COAST PILOT, LIGHT LIST, AND CURRENT TABLES.
Condition: Improper/Lack of Maintenance
Due 3 August 2004
Resolved 23 December 2004
Resolution: COMPLETED.
Lifesaving › Buoyant Apparatus
Issued 11 July 2003 Resolved
BUOYANT APPARATUS WITH A CAPACITY OF 15 POB REQUIRED. 12 PERSON BUOYANT APPARATUS PLACED ONBOARD 11 JULY 2003. VESSEL RESTRICTED TO CARRYING A TOTAL OF 24 PERSONS ONBOARD UNTIL PROPER BUOYANT APPARATUS PLACED ONBOARD.. LEGACY COMPONENT DESC: Insufficient Capacity
Due 30 September 2003
Resolved 12 September 2003
Resolution: BUOYANT APPARATUR REPLACED. RESTRICTION ON CARRIAGE OF PASSENGERS REMOVED THIS DATE.
Engineering
Issued 5 July 2003 Resolved
Stbd engineroom ventilation blower inoperable. Corrective action required to the satisfaction of the attending USCG Marine Inspector prior to carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 July 2003
Resolution: CLEARED MSD SAIPAN ACTIVITY 1844276 DATED 11 JULY 2003.
Operations/Management
Issued 5 July 2003 Resolved
Vessel Captain and crew did not know the location of the hand bilge pump. Corrective action to the satisfaction of the attending USCG Marine Inspector required prior to the carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 July 2003
Resolution: CLEARED MSD SAIPAN ACTIVITY 1844276 DATED 11 JULY 2003.
Operations/Management
Issued 5 July 2003 Resolved
Captain unable to demonstrate ability to conduct test of EPIRB. Corrective action, including reading of manufacturer's testing instructions, required to the satisfaction of the attending USCG Marine Inspector prior to carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 July 2003
Resolution: CLEARED MSD SAIPAN ACTIVITY 1844276 DATED 11 JULY 2003.
Operations/Management
Issued 5 July 2003 Resolved
Vessel master consistantly fails to examine steering gear per the requirements of 46 CFR 185.320. Corrective action required to the satisfaction of the attending USCG Marine Inspector before carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 July 2003
Resolution: CLEARED MSD SAIPAN ACTIVITY 1844276 DATED 11 JULY 2003.
Lifesaving
Issued 5 July 2003 Resolved
EPIRB Hydrostatic release device, good for two years service, not marked with service life expiration date. Condition and age of EPIRB gives credable evidence that hydrostatic release device is beyond two year service life. New hydrostatic release device required prior to carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 July 2003
Resolution: CLEARED MSD SAIPAN ACTIVITY 1844276 DATED 11 JULY 2003.
Documentation › Logs/Records
Issued 5 July 2003 Resolved
Man overboard drill log entry not made per the requirements of 46 CFR 185.520. Corrective action required not later than 19 July 2003.
Due 19 July 2003
Resolved 11 July 2003
Resolution: CLEARED MSD SAIPAN ACTIVITY 1844276 DATED 11 JULY 2003.
Documentation › Logs/Records
Issued 5 July 2003 Resolved
Firefighting drill log entry not made per the requirements of 46 CFR 185.524. Corrective action required not later than 19 July 2003.
Due 19 July 2003
Resolved 11 July 2003
Resolution: CLEARED MSD SAIPAN ACTIVITY 1844276 DATED 11 JULY 2003.
Documentation › Logs/Records
Issued 5 July 2003 Resolved
Monthly test of EPIRB not conducted, nor was it logged per the requirements of 46 CFR 185.728. Corrective action required not later than 19 July 2003.
Due 19 July 2003
Resolved 11 July 2003
Resolution: CLEARED MSD SAIPAN ACTIVITY 1844276 DATED 11 JULY 2003.
Documentation
Issued 5 July 2003 Resolved
Captain without FCC Marine Operators Permit required by 47 CFR 80. Corrective action required not later than 05 AUG 2003.
Due 5 August 2003
Resolved 11 July 2003
Resolution: CLEARED MSD SAIPAN ACTIVITY 1844276 DATED 11 JULY 2003.
Engineering
Issued 5 July 2003 Resolved
Emergency Fuel Shutoffs fail to meet intended function as evidenced by test of shutoffs. System to be examined by owner/operator, reworked as necessary including possible valve replacement, and tested to the satisfaction of the attending USCG Marine Inspector not later than 19 July 2003.
Due 19 July 2003
Resolved 11 July 2003
Resolution: CLEARED MSD SAIPAN ACTIVITY 1844276 DATED 11 JULY 2003.
Accommodation/Occupational Safety
Issued 5 July 2003 Resolved
One of two emergency flashlights inoperable; other flashlight batteries weak. Corrective action required to the satisfaction of the attending USCG Marine Inspector prior to carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 July 2003
Resolution: CLEARED MSD SAIPAN ACTIVITY 1844276 DATED 11 JULY 2003.
Lifesaving
Issued 5 July 2003 Resolved
LF/BA covered with tarp (tied in place) that prevented proper access to LF/BA equipment and utilization of unit. Tarp shall be permanently removed and access maintained at all times and under all conditions.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 July 2003
Resolution: CLEARED MSD SAIPAN ACTIVITY 1844276 DATED 11 JULY 2003.
Navigation › Piloting/Steering
Issued 5 July 2003 Resolved
Compass light missing. Vessel, absent other prohibition such as suspension of COI, may only operate during daylight hours only until the compass light is restored to the satisfaction of an attending USCG Marine Inspector. LEGACY COMPONENT DESC: Magnetic Compass
Action required: 705 - Other - as specified
Resolved 11 July 2003
Resolution: CLEARED MSD SAIPAN ACTIVITY 1844276 DATED 11 JULY 2003.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 5 July 2003 Resolved
Stbd MDE tachometer located in the engineroom in not functioning. Proper functioning of all propulsion engine gauges shall be demonstrated to the satisfaction of an attending USCG Marine Inspector not later than 19 July 2003. LEGACY COMPONENT DESC: Gauges
Due 19 July 2003
Resolved 11 July 2003
Resolution: CLEARED MSD SAIPAN ACTIVITY 1844276 DATED 11 JULY 2003.
Construction/Loadline › Structures
Issued 5 July 2003 Resolved
Port side guardrail cable securing bracket missing. Corrective action required to the satisfaction of the attending USCG Marine Inspector not later than 19 July 2003.
Due 19 July 2003
Resolved 11 July 2003
Resolution: CLEARED MSD SAIPAN ACTIVITY 1844276 DATED 11 JULY 2003.
Lifesaving › Lifebuoys
Issued 5 July 2003 Resolved
Lifebuoy self-igniting light strobe light lens observed to have water/moisture within it, creating the likelyhood of unit failure/non-functioning during extremis due to corrosion. Corrective action required to the satisfaction of an attending USCG Marine Inspector not later than 19 July 2003. LEGACY COMPONENT DESC: Self-igniting Lights
Due 19 July 2003
Resolved 11 July 2003
Resolution: CLEARED MSD SAIPAN ACTIVITY 1844276 DATED 11 JULY 2003.
Accommodation/Occupational Safety › Medical/First Aid
Issued 5 July 2003 Resolved
First Aid Kit requires replacement/renewal to meet 46 CFR Subchapter T requirements to the satisfaction of the attending USCG Marine Inspector prior to vessel carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 July 2003
Resolution: CLEARED MSD SAIPAN ACTIVITY 1844276 DATED 11 JULY 2003.
Construction/Loadline
Issued 5 July 2003 Resolved
Engineroom hatchcover insulation requires reattachment to the satisfaction of an attending USCG Marine Inspector not later than 19 July 2003.
Due 19 July 2003
Resolved 11 July 2003
Resolution: CLEARED MSD SAIPAN ACTIVITY 1844276 DATED 11 JULY 2003.
Documentation › Certificates/Documents
Issued 10 May 2002 Resolved
Vessel's Certificate of Documentation not current in non-adherence with 46 CFR 67.
Condition: Unknown
Due 31 May 2002
Resolved 5 July 2003
Documentation › Certificates/Documents
Issued 10 May 2002 Resolved
Vessel owner/operator has not submitted an Application for Inspection in non-adherence with 46 CFR 176.105. LEGACY COMPONENT DESC: Application for Inspection
Condition: Unknown
Due 31 May 2002
Resolved 5 July 2003
Resolution: Administratively cleared.
Lifesaving › Buoyant Apparatus
Issued 10 May 2002 Resolved
Vessel's buoyant apparatus requires renewal to meet original design specifications contained in 46 CFR Subchapter Q.
Condition: Unknown
Due 31 May 2002
Resolved 11 July 2003
Resolution: 12 PERSON BUOYANT APPARATUS PLACED ONBOARD. VESSEL RESTRICTED TO CARRYING A TOTAL OF 24 PERSONS ONBOARD. SEE ACTIVITY MSD SAIPAN 1844276 DATED 11 JULY 2003.
Lifesaving
Issued 10 May 2002 Resolved
Vessel hydrostatic release device (disposable) expired in non-adherence with 46 CFR 185.740. LEGACY COMPONENT DESC: EBIRB Hydrostatic Release
Due 31 May 2002
Resolved 17 May 2002
Navigation › Piloting/Steering
Issued 10 May 2002 Resolved
Vessel's light list not currently corrected for area of transit in non-adherence with 46 CFR 184.420. LEGACY COMPONENT DESC: Light List
Condition: Improper/Lack of Maintenance
Due 31 May 2002
Resolved 31 May 2002
Resolution: Corrected.
Navigation › Collision/Grounding Avoidance
Issued 10 May 2002 Resolved
Vessel's permanently affixed horn not operable in non-adherence with COLREGs. Vessel to repair/replace horn not later than 31May02. Unitl such time horn is repaired/replaced vessel shall carry portable sound producing device (horn). LEGACY COMPONENT DESC: Horn
Condition: Improper/Lack of Maintenance
Due 31 May 2002
Resolved 17 May 2002
Operations/Management › Drills/Instruction
Issued 10 May 2002 Resolved
Vessel written passenger safety orientation not in a language(s) understood by passengers carried in non-adherence with 46 CFR 185. LEGACY COMPONENT DESC: Passenger Safety Orientation
Condition: Unknown
Due 17 May 2002
Resolved 17 May 2002
Operations/Management › Drills/Instruction
Issued 10 May 2002 Resolved
Vessel's Emergency instruction List not in a language(s) understood by passengers carried in non-adherence with 46 CFR 185. LEGACY COMPONENT DESC: Emergency Instruction List
Condition: Unknown
Due 17 May 2002
Resolved 17 May 2002
Documentation › Logs/Records
Issued 10 May 2002 Resolved
Vessel logbook shall be established to reflect man overboard drills per 46 CFR 185.520; fire fighting drills per 46 CFR 185.524; monthly EPIRB test per 46 CFR 185.728; and survival craft maintenance per 46 CFR 185/702. LEGACY COMPONENT DESC: Logbook/Record (unofficial)
Due 31 May 2002
Resolved 17 May 2002
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 10 May 2002 Resolved
Fixed gas extinguishing system not functioning. Not later than 10Jun02 system functionality shall be fully restored including auto power ventilation/engine shutoff, visual & audible alarm, remote & manual activation, marking at control station & alarm, activation instructions at control & space.
Condition: Improper/Lack of Maintenance
Due 10 June 2002
Resolved 31 May 2002
Resolution: Corrected.
Construction/Loadline › Hull › Hull Plating
Issued 30 March 2002 Resolved
Small fracture (3 inches) observed in bow well above waterlined.
Condition: Damaged By Earlier Event
Due 30 March 2002
Resolved 30 March 2002
Resolution: FRP scarfed away with new matting installed.
Fire Fighting
Issued 17 May 2000 Resolved
Install closure devices for the engine room intake vents.
Condition: Unknown
Due 18 June 2000
Resolved 1 June 2002
Resolution: Ventilation is powered and shuts down when fixed fire extinguishing system activated.
Fire Fighting
Issued 27 March 2000 Resolved
Install fire dampers for the engine room ventilation openings and prove theoperation.
Condition: Unknown
Due 27 March 2000
Resolved 27 March 2000
Lifesaving
Issued 27 March 2000 Resolved
Conduct and log monthly EPIRB tests and quarterly emergency drills.
Condition: Unknown
Due 27 March 2000
Resolved 27 March 2000
Engineering
Issued 27 March 2000 Resolved
Install lagging on the port and stbd engines from the turbo chargers to thefirst point of water injection on the exhaust piping.
Condition: Unknown
Due 27 March 2000
Resolved 27 March 2000
Navigation
Issued 27 March 2000 Resolved
Prove the operation of the ships horn.
Condition: Unknown
Due 27 March 2000
Resolved 27 March 2000
Construction/Loadline
Issued 27 March 2000 Resolved
Stencil the vessel's name on the port and stbd bow of the vessel. The vessel's name shall be no less than 4 inches in height.
Condition: Unknown
Due 27 March 2000
Resolved 27 March 2000
Construction/Loadline
Issued 27 March 2000 Resolved
Restore to original the following bonding angles: a. the aft bulkhead to_x001C_ #2 port long connection in the fwd compartment; b. the deck to bulkhead connections on the port and stbd side in the "V" compartment; c. the strut block to hull connection on the stbd side in the lazarette.
Condition: Unknown
Due 27 March 2000
Resolved 27 March 2000
Lifesaving
Issued 27 March 2000 Resolved
Conduct emergency drills in the presence of the attending USCG marine inspector.
Condition: Unknown
Due 27 March 2000
Resolved 27 March 2000
Electrical
Issued 5 March 1999 Resolved
Repair lighting fixtures in main cabin, engine room and steering/fuel space.
Condition: Unknown
Due 5 March 1999
Resolved 5 March 1999
Construction/Loadline
Issued 5 March 1999 Resolved
Install valves to existing thru-hulls in steering space.
Condition: Unknown
Due 5 March 1999
Resolved 5 March 1999
Navigation
Issued 5 March 1999 Resolved
Repair compass light. Until such time repairs are made, vessel is restricted to daylight operations only.
Condition: Unknown
Due 5 March 1999
Resolved 5 March 1999
Engineering
Issued 5 March 1999 Resolved
Suitably insulate main engine exhaust piping.
Condition: Unknown
Due 5 March 1999
Resolved 5 March 1999
Construction/Loadline
Issued 5 March 1999 Resolved
Install high level bilge alarms as per 46 CFR 182.530.
Condition: Unknown
Due 5 March 1999
Resolved 5 March 1999
Engineering
Issued 5 March 1999 Resolved
Install fuel shut-off valve for main fuel tank.
Condition: Unknown
Due 5 March 1999
Resolved 5 March 1999
Lifesaving
Issued 5 March 1999 Resolved
Provide EPIRB hydro date.
Condition: Unknown
Due 5 March 1999
Resolved 5 March 1999
Fire Fighting
Issued 5 March 1999 Resolved
Provide three (3) 2.5 gallon fire buckets, with proper markings and lanyard.
Condition: Unknown
Due 5 March 1999
Resolved 5 March 1999
Lifesaving
Issued 5 March 1999 Resolved
Properly lash paddles to life float.
Condition: Unknown
Due 5 March 1999
Resolved 5 March 1999
Lifesaving
Issued 5 March 1999 Resolved
Replace or repair (as per manufacturers repair instructions) life ring.
Condition: Unknown
Due 5 March 1999
Resolved 5 March 1999
Lifesaving
Issued 5 March 1999 Resolved
Repair gouged lifefloat as per manufacturers repair instructions.
Condition: Unknown
Due 5 March 1999
Resolved 5 March 1999
Lifesaving
Issued 5 March 1999 Resolved
Place on board a properly outfitted first aid kit.
Condition: Unknown
Due 5 March 1999
Resolved 5 March 1999
Accommodation/Occupational Safety
Issued 5 March 1999 Resolved
replace broken/shattered port and stbd fwd windows.
Condition: Unknown
Due 5 March 1999
Resolved 5 March 1999
Navigation
Issued 5 March 1999 Resolved
Repair anchor light.
Condition: Unknown
Due 5 March 1999
Resolved 5 March 1999
Fire Fighting
Issued 5 March 1999 Resolved
Install fixed fire ext system as per 46 CFR 181.410.
Condition: Unknown
Due 5 March 1999
Resolved 5 March 1999
Accommodation/Occupational Safety
Issued 5 March 1999 Resolved
Repair inoperative MSD.
Condition: Unknown
Due 5 March 1999
Resolved 5 March 1999
Accommodation/Occupational Safety
Issued 5 March 1999 Resolved
Repair forward deck railings.
Condition: Unknown
Due 5 March 1999
Resolved 5 March 1999
Electrical
Issued 5 March 1999 Resolved
Remove dead ended wiring under pilot station and steering space. Ensure wiring is supported as per 46 CFR part 183.
Condition: Unknown
Due 5 March 1999
Resolved 5 March 1999
Accommodation/Occupational Safety
Issued 5 March 1999 Resolved
Mark forward emergency escape hatch "EMERGENCY EXIT, KEEP CLEAR."
Condition: Unknown
Due 5 March 1999
Resolved 5 March 1999
Lifesaving
Issued 22 February 1998 Resolved
Provide registered 406 MHZ EPIRB to meet criteria of 46CFR 184.710.
Condition: Unknown
Due 22 February 1998
Resolved 22 February 1998
Lifesaving
Issued 22 February 1998 Resolved
Renew life ringbuoy behind operating station to meet criteria of 46CFR_x001C_ Subchapter Q.
Condition: Unknown
Due 22 February 1998
Resolved 22 February 1998
Lifesaving
Issued 22 February 1998 Resolved
Provide lanyard with detachable clip for life ringbuoy as per 46CFR 180.70.
Condition: Unknown
Due 22 February 1998
Resolved 22 February 1998
Lifesaving
Issued 22 February 1998 Resolved
Provide retroreflective tape for life ringbuoys to meet 46CFR 185.604.
Condition: Unknown
Due 22 February 1998
Resolved 22 February 1998
Lifesaving
Issued 22 February 1998 Resolved
Provide bright watertight container for distress signals to meet criteria of 46CFR 180.68.
Condition: Unknown
Due 22 February 1998
Resolved 22 February 1998
Lifesaving
Issued 22 February 1998 Resolved
Log man overboard drills and training to meet criteria of 46CFR 185.520.
Condition: Unknown
Due 22 February 1998
Resolved 22 February 1998
Lifesaving
Issued 22 February 1998 Resolved
Provide appropriate stowage/bracket for lower lifering to meet the requirements of 46CFR 180.78.
Condition: Unknown
Due 22 February 1998
Resolved 22 February 1998
Lifesaving
Issued 22 February 1998 Resolved
Update Emergency Instruction List to meet requirements of 46CFR 185.510/185.520.
Condition: Unknown
Due 22 February 1998
Resolved 22 February 1998
Construction/Loadline
Issued 22 February 1998 Resolved
Provide copy of approved plans to allow for regulatory review of subdivision and watertightness; particularly the bulkhead between the lazerrette and engineroom and the bulkhead between the engineroom and the berthing space._x001C_
Condition: Unknown
Due 22 February 1998
Resolved 22 February 1998
Construction/Loadline
Issued 22 February 1998 Resolved
Remove sink drain line to seavalve.
Condition: Unknown
Due 22 February 1998
Resolved 22 February 1998
Engineering
Issued 22 February 1998 Resolved
Install gooseneck vent for lazerrette/diesel fuel tank not less than 1.5 inch in diameter to comply with 46CFR 182.470._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 February 1998
Resolved 22 February 1998
Engineering
Issued 22 February 1998 Resolved
Tighten port and stbd shaft glands to reduce/eliminate leakage._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 February 1998
Resolved 22 February 1998
Electrical
Issued 22 February 1998 Resolved
Remove deadend wiring in engine room._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 February 1998
Resolved 22 February 1998
Lifesaving
Issued 22 February 1998 Resolved
Update first aid kit to meet requirements of 46CFR 184.710.
Condition: Unknown
Due 22 February 1998
Resolved 22 February 1998
Lifesaving
Issued 22 February 1998 Resolved
Document testing of EPIRB when obtained to meet criteria of 46CFR 185.728.
Condition: Unknown
Due 22 February 1998
Resolved 22 February 1998
Documentation
Issued 22 February 1998 Resolved
Obtain FCC Operation Permits for operators to meet requirements of 47CFR 13.
Condition: Unknown
Due 22 February 1998
Resolved 22 February 1998
Lifesaving
Issued 22 February 1998 Resolved
Log firefighting drills and training to meet criteria of 46CFR 185.524.
Condition: Unknown
Due 22 February 1998
Resolved 22 February 1998
Lifesaving
Issued 22 February 1998 Resolved
Log survivial craft maint to meet criteria of 46CFR 185.702.
Condition: Unknown
Due 22 February 1998
Resolved 22 February 1998
Navigation
Issued 22 February 1998 Resolved
Provide illuminated compass to meet criteria of 46CFR 184.402.
Condition: Unknown
Due 22 February 1998
Resolved 22 February 1998
Navigation
Issued 22 February 1998 Resolved
Repair stern navigation light to meet COLREGS.
Condition: Unknown
Due 22 February 1998
Resolved 22 February 1998
Navigation
Issued 22 February 1998 Resolved
Provide navigation publications or appropriate extracts to meet 46CFR 184.420; criteria includes Coast Pilot [name withheld], Tide Tables, and chart of operating area.
Condition: Unknown
Due 22 February 1998
Resolved 22 February 1998
Navigation
Issued 22 February 1998 Resolved
Provide emergency broadcast placard at the operating station as per 46CFR 184.506.
Condition: Unknown
Due 22 February 1998
Resolved 22 February 1998
Electrical
Issued 22 February 1998 Resolved
Obtain additional emergency light to meet criteria of 46CFR 183.430.
Condition: Unknown
Due 22 February 1998
Resolved 22 February 1998
Engineering
Issued 22 February 1998 Resolved
Provide 30x30 mesh flame screens for fuel vents to meet 46CFR 182.450.
Condition: Unknown
Due 22 February 1998
Resolved 22 February 1998
Fire Fighting
Issued 22 February 1998 Resolved
Service the fixed fire extinguisher system to NFPA standards and 46CFR 181.410/181.420.
Condition: Unknown
Due 22 February 1998
Resolved 22 February 1998
Fire Fighting
Issued 22 February 1998 Resolved
Have all fire extinguishers hydrostatically tested to meet provisions of NFPA 10.
Condition: Unknown
Due 22 February 1998
Resolved 22 February 1998
Electrical
Issued 22 February 1998 Resolved
Electrically bond fill pipe to fuel tank to meet 46CFR 182.445._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 February 1998
Resolved 22 February 1998
Engineering
Issued 22 February 1998 Resolved
Provide engineroom with supply ventilation to meet requirements of 46CFR 182.425/182.430._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 February 1998
Resolved 22 February 1998
Lifesaving
Issued 22 February 1998 Resolved
Convert existing buoyant apparatus to a lifefloat to meet requirements of 46CFR 180.200.
Condition: Unknown
Due 22 February 1998
Resolved 22 February 1998
Construction/Loadline
Issued 22 February 1998 Resolved
Permanently wire lazerrete and "V" space bilge pump.
Condition: Unknown
Due 22 February 1998
Resolved 22 February 1998
Lifesaving
Issued 22 February 1998 Resolved
Mark upperdeck passenger limit to comply with 46 CFR 185.602.
Condition: Unknown
Due 22 February 1998
Resolved 22 February 1998
Accommodation/Occupational Safety
Issued 22 February 1998 Resolved
Repair guardrail port side.
Condition: Unknown
Due 22 February 1998
Resolved 22 February 1998
Documentation
Issued 28 September 1990 Resolved
PROVIDE DOCUMENTATION THAT VESSEL IS EITHER DOCUMENTED OR HAS CNMI REGISTRATION. THIS ITEM TO BE COMPLETED PRIOR TO ISSUANCE OF COI.
Condition: Unknown
Due 28 September 1990
Resolved 28 September 1990
Navigation
Issued 28 September 1990 Resolved
PROVIDE VHF-FM RADIO. VESSEL MAY NOT OPERATE MORE THAN 1000 FEET FROM SHORE UNTIL THIS ITEM COMPLETED.
Condition: Unknown
Due 28 September 1990
Resolved 28 September 1990
Documentation
Issued 28 September 1990 Resolved
POST OIL POLLUTION PREVENTION PLACARD.
Condition: Unknown
Due 28 September 1990
Resolved 28 September 1990
Documentation
Issued 28 September 1990 Resolved
PROVIDE FCC SAFETY RADIO TELEPHONE CERTIFICATE. VESSEL MAY NOT OPERATE MORE THAN 1000 FEET FROM SHORE UNTIL THIS ITEM COMPLETED.
Condition: Unknown
Due 28 September 1990
Resolved 28 September 1990
Documentation
Issued 28 September 1990 Resolved
IMPLEMENT COAST GUARD DRUG/ALCOHOL ABUSE TESTING PROGRAM.
Condition: Unknown
Due 28 September 1990
Resolved 28 September 1990
Documentation
Issued 28 September 1990 Resolved
PROVIDE WASTE MANAGEMENT PLAN.
Condition: Unknown
Due 28 September 1990
Resolved 28 September 1990
Documentation
Issued 28 September 1990 Resolved
PROVIDE WASTE MANAGEMENT PLACARD.
Condition: Unknown
Due 28 September 1990
Resolved 28 September 1990

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.