Records from 1990 to 2001. Most recent: inspection, 15 May 2001.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 12
15 May 2001
Re-Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1393675
2 March 2000
COI Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1397364
26 May 1994
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1448547
3 March 1994
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1389777
3 February 1994
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1370778
8 April 1993
Hull Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 827936
10 June 1992
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1254916
10 April 1992
Hull Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1257309
28 June 1991
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 935357
12 April 1991
Hull Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 914685
8 January 1991
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1214777
11 April 1990
Hull Examination · Initial Certification
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 904475
Electrical
Issued 8 April 1993
Resolved
PROVE PROPER OPERATION OF EMERGENCY FLASHLIGHT. VESSEL RESTRICTED TO DAYLIGHT OPERATION PENDING COMPLETION.
Condition: Unknown
Due 24 May 1993
Resolved 24 May 1993
Electrical
Issued 8 April 1993
Resolved
REMOVE DEAD END WIRES FROM CONSOLE, OR REPAIR STARBOARD ENGINE TILT SWITCH.
Condition: Unknown
Due 24 May 1993
Resolved 24 May 1993
Documentation
Issued 8 April 1993
Resolved
PROVIDE COPY OF CURRENT FCC MARINE RADIO OPERATOR'S PERMIT FOR VESSEL MASTER.
Condition: Unknown
Due 8 April 1993
Resolved 8 April 1993
Lifesaving
Issued 8 April 1993
Resolved
PROPERLY LABEL LIFE JACKET STOWAGE, TO SHOW ACTUAL STOWAGE LOCATIONS CORRECTLY.
Condition: Unknown
Due 24 May 1993
Resolved 24 May 1993
Engineering
Issued 10 April 1992
Resolved
PROVIDE ACCEPTABLE GASOLINE FUEL FILTERS WITH METAL BOWLS FOR THE OUTBOARD ENGINES.
Condition: Unknown
Due 10 April 1992
Resolved 10 April 1992
Documentation
Issued 10 April 1992
Resolved
PROVIDE AN FCC MARINE OPERATOR PERMIT FOR THE VESSEL'S MASTER.
Condition: Unknown
Due 10 April 1992
Resolved 10 April 1992
Construction/Loadline
Issued 10 April 1992
Resolved
INSTALL SUITABLE VENTILITATION DUCTING FROM THE FRESH AIR INTAKES TO THE BOTTOM OF THE FUEL TANK SPACE.
Condition: Unknown
Due 10 April 1992
Resolved 10 April 1992
Electrical
Issued 10 April 1992
Resolved
INTERLOCK THE FUEL COMPARTMENT BLOWER WITH THE IGNITION SWITCH.
Condition: Unknown
Due 10 April 1992
Resolved 10 April 1992
Engineering
Issued 10 April 1992
Resolved
POST A RED WARNING SIGN STATING THAT THE BLOWERS SHALL BE OPERATED PRIOR TOSTARTING THE ENGINES FOR A SUFFICIENT TIME TO INSURE AT LEAST ONE COMPLETE CHANGE OF AIR IN THE COMPARTMENT.
Condition: Unknown
Due 10 April 1992
Resolved 10 April 1992
Engineering
Issued 12 April 1991
Resolved
PROVIDE SUITABLE DUCTING FOR THE SUPPLY VENTS IN ACCORDANCE WITH 46 CFR 182.15-45(f) THROUGH (h).
Condition: Unknown
Due 12 April 1991
Resolved 12 April 1991
Engineering
Issued 12 April 1991
Resolved
PROVIDE EXHAUST VENTILATION DUCTING WHERE THE INTAKE END IS LEAD AS DIRECTLY AS POSSIBLE TO THE LOWEST PART OF THE FUEL TANK COMPARTMENT.
Condition: Unknown
Due 12 April 1991
Resolved 12 April 1991
Engineering
Issued 12 April 1991
Resolved
PROVIDE AN EMERGENCY FUEL SHUTOFF VALVE ON THE FUEL TANK OPERABLE FROM THE MAIN DECK IN ACCORDANCE WITH 46 CFR 182.15-40(b)(3).
Condition: Unknown
Due 12 April 1991
Resolved 12 April 1991
Engineering
Issued 12 April 1991
Resolved
REPLACE THE RUBBER FUEL LINES WITH COPPER TUBING IN ACCORDANCE WITH 46 CFR 182.15-40(a).
Condition: Unknown
Due 12 April 1991
Resolved 12 April 1991
Fire Fighting
Issued 12 April 1991
Resolved
PROVIDE AN ACCEPTABLE FIXED EXTINGUISHING SYSTEM FOR THE ENCLOSED GASOLINE TANK SPACE.
Condition: Unknown
Due 12 April 1991
Resolved 12 April 1991
Engineering
Issued 12 April 1991
Resolved
SEAL DECK PENETRATION ABOVE THE FUEL TANK SO AS TO MAKE THAT PORTION OF THEDECK VAPORTIGHT.
Condition: Unknown
Due 12 April 1991
Resolved 12 April 1991