MAURY USCG vessel records Sign in
← All vessels

BULK DISCOVERY

BULK DISCOVERY is a 1989 freight ship. The Coast Guard has recorded 33 inspections since 1990, most recently in May 2014, along with 29 deficiencies and 7 operational controls.

Records from 1990 to 2014. Most recent: inspection, 19 May 2014.

Built
1989
Last inspected
19 May 2014
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8806187 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
356734
Flag
PANAMA
—
Maury page id
psix-356734

Inspections, by type

…with no type recorded22
Years with a record 20 calendar years (1990–2014)
The 33 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 12 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it22691 - Convention (Subpart B), Net Ton
36986 - Convention (Subpart B), Gross Ton
79326 - Displacement, Ton
69349 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 33

19 May 2014 PII Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4852821
22 February 2012 ISPS III Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4246977
6 February 2012 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4236098
20 January 2012 Ballast Water Examination · PI Safety Exam · ISPS III Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4225473
17 December 2011 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4202229
16 December 2011 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4209268
15 December 2011 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4209006
21 September 2011 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4150834
13 September 2011 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4143849
21 July 2008 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3274514
26 February 2007 Type not recorded
No type recorded · USCGC BONITO (WPB 87341) · USCG Northeast District (CGD-NE) · Activity 2881862
1 January 2007 PII Safety Exam · Deficiency Check · Ballast Water Examination · MARPOL Annex I Examination · MARPOL Annex V Examination · ISPS III Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2848503
8 October 2006 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2795996
10 February 2006 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2582937
9 February 2006 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2582234
23 June 2005 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2400354
21 May 2005 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2364285
4 December 2003 Annual Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1958666
1 November 2002 Annual Inspection
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 1699528
5 February 2001 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 286781
10 October 2000 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 286882
5 April 1999 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 427232
19 July 1998 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 418078
26 November 1997 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 510351
1 September 1997 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 407424
20 September 1996 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 395587
8 May 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 378390
19 October 1994 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 371572
5 March 1994 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 367193
29 September 1993 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 455174
3 February 1993 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 356136
11 September 1991 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 345697
2 November 1990 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 340219

Deficiency record · 29

Engineering › Lubricating Oil Storage/Transfer System › Gauge
Issued 19 May 2014 Resolved
2099-Other (SOLAS Op Def)-The means in para. 2.2.3.5.2 of chap. II-2/4 shall be maintained in the proper condition to ensure their continues accurate functioning in service. Numerous self-closing sight glass valves on oil tanks inop or intentionally blocked open w/ fabricated blocking devices. Provide C.A.P. from Company w/ concurrence from certificate issuing authority. SOLAS 74 am II-2/4 40a
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 26 May 2014
Resolved 23 May 2014
Resolution: PSC New Orleans received corrective action plan and class report from Bureau Veritas satisfying the requirement.
Operations/Management › Pollution › Control of Garbage
Issued 19 May 2014 Resolved
2120-Garbage-Every ship 400GT shall carry a Garbage Mngmt Plan which the crew shall follow. Vessel is storing unsegregated garbage in areas not authorized by the GMP. Specifically crew storing paint waste/buckets, oily rags, oiled cardboard & other garbage in engine room areas not authorized for garbage. Provide C.A.P. from Company. MARPOL 73/78 Annex V/9.2 40c
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 26 May 2014
Resolved 23 May 2014
Resolution: PSC New Orleans received corrective action plan and class report from Bureau Veritas satisfying the requirement.
Engineering › Steering Gear System › Actuator
Issued 18 February 2012 Resolved
0936 - Steering Gear - Every ship shall be provided with a main steering gear to the satisfaction of the administration. While conducting steering test from the bridge on both system 1 and system 2 pump 1 and 2 non-follow-up mode, the rudder continues to move after the NFU lever is released. SOLAS 09 cond. II-1/29
Action required: 705 - Other - as specified
Due 7 March 2012
Resolved 25 February 2012
Resolution: Received, reviewed and accepted Sperry Marine technician''s report stating he observed steering system operating normal. He cleaned and NFU switch contacts and recommended ship carry spare NFU switch and attend safety training class.
Electrical › Electric Generation Source (emergency) › Number of Sources
Issued 6 February 2012 Resolved
1430 - Auxiliary Engines - A second source of energy shall be provided on the emergency generating set for an additional three starts. The emergency generator has two independent battery sets for starting, however the crew could not demonstrate how to independently select one battery set from the other for starting. - SOLAS 2009 cons. II-1/44
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 9 February 2012
Resolved 9 February 2012
Resolution: Received, reviewed and accepted class report from BV stating the deficiency was rectified. C/E installed a selector switch to the EDG starting system. Surveyor witnessed EDG start with both sets of batteries independently without failure.
Documentation › Certificates/Documents › IOPP Certificate
Issued 6 February 2012 Resolved
0150 - Oil Pollution Prevention - An IOPPC shall be issued IAW the provisions of reg. 6 of MARPOL Anx 1. There are differences between the tank capacities listed on section 3.1 of the supplement to the IOPP and what is listed as the capacities of those tanks in the ship's engine machinery particulars as provided by the Chief Engineer. - MARPOL 2006 cons. Annex I/7
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 9 February 2012
Resolved 9 February 2012
Resolution: Received, reviewed and accepted class report BV stating the deficiency was rectified. A new IOPP Certificate and Supplement has been issued. The Supplement, piping diagrams and Eng. Machinery Particulars now reflect the same tank and correct capacities.
Electrical › Electric Supply System (service) › Cable
Issued 20 January 2012 Resolved
0950 - Electric equipment in general - PSCO observed the electrical wiring for the NAVTEX was hard-wired directly into the ship's 24-volt, emergency battery power supply, passing through two bulkheads. - SOLAS 09 cond. II-1/45.a
Action required: 705 - Other - as specified
Due 20 January 2012
Resolved 24 January 2012
Resolution: Received, reviewed and accepted Class report from [name withheld] attesting to the proper repair to the 24VDC wiring assembly.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 20 January 2012 Resolved
0710 - Fire Prevention - PSCO observed the valve for the diesel oil service tank, tank level indicating valve was braced open with metal wiring. Upon removal, valve began to leak at a steady stream creating a potential fire hazard. - SOLAS 09 cond. II-2/4.1.1
Action required: 705 - Other - as specified
Due 20 January 2012
Resolved 24 January 2012
Resolution: Received, reviewed and accepted Class report from [name withheld] attesting to the crew properly repairing the tank level indicating valve.
Engineering › Steering Gear System › Rudder
Issued 20 January 2012 Resolved
0936 - PSCO observed that in non follow-up mode for the remote steering location that when helm commands stopped, rudder continued to drift to port and starboard directions. - SOLAS 09 cond. II-2/4.2.2
Action required: 705 - Other - as specified
Due 20 January 2012
Resolved 24 January 2012
Resolution: Received, reviewed and accepted Class report from [name withheld] attesting to the proper operation of the steering gear assembly.
Navigation › Piloting/Steering › US Coast Pilot
Issued 20 January 2012 Resolved
1570 - Nautical Publications - PSCO observed that the Coast Pilot and List of Lights were out of date. - SOLAS 09 cond. V/27.
Action required: 705 - Other - as specified
Due 20 January 2012
Resolved 24 January 2012
Resolution: Received, reviewed and accepted Class report from [name withheld] attesting to the Publications being ordered for the vessel.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 20 January 2012 Resolved
0710 - PSCO observed that the original diesel fuel oil tank which services the on-deck air compressor has failed. The crew has replaced the original fuel oil tank with a non-class approved 42-gallon steel drum that is currently blocking the safe egress from the bridge to the primary life-saving equipment. - SOLAS 09 cond. I/11.b
Action required: 705 - Other - as specified
Due 20 January 2012
Resolved 24 January 2012
Resolution: Received, reviewed and accepted Class report from [name withheld] attesting to the removal from service of the ships deck aux. air compressor and the associuated 42 gallon drum blocking the egress from the bridge.
Fire Fighting › Ventilation Systems › Fans
Issued 20 January 2012 Resolved
1970 - Ventilation procedures/equipment - PSCO observed the closing devices for the #2 and #3 mechanical ventilation exhausts were rusted and the crew was unable to secure both vents in the closed position. - SOLAS 09 cond. II-2/9.1.3
Action required: 705 - Other - as specified
Due 20 January 2012
Resolved 24 January 2012
Resolution: Received, reviewed and accepted Class report from [name withheld] attesting to the proper operation of the forced ventiallation closure devices.
Construction/Loadline › Structures › Superstructure
Issued 20 January 2012 Resolved
0930 - Stability/strength - PSCO observed a 3-foot by 2-inch fracture in the weld and the superstructure forward on the port side. - ICLL 2002 cond. II/25.1
Action required: 705 - Other - as specified
Due 20 January 2012
Resolved 24 January 2012
Resolution: Received, reviewed and accepted Class report from [name withheld] attesting to the proper repair to the fracture in the ships house.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 20 January 2012 Resolved
0950 - Electric equipment in general - PSCO observed broken welds in each of the high-voltage junction boxes on the port side. - SOLAS 09 cons. II-1/45.5.4
Action required: 705 - Other - as specified
Due 20 January 2012
Resolved 24 January 2012
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Documentation › Logs/Records › Oil Record Book
Issued 20 January 2012 Resolved
1710 - Oil Record Book - During the review of the ORB, the PSCO noted inconsistencies regarding the recorded weekly retention soundings between 25DEC11 and 8JAN12.
Action required: 705 - Other - as specified
Due 20 January 2012
Resolved 24 January 2012
Resolution: Received, reviewed and accepted Class report from [name withheld] attesting to the implementation of the corrective action action plan.
Navigation › Electronic Positioning › Radio Direction Finding Device
Issued 20 January 2012 Resolved
1510 - Navigation Equipment - PSCO observed the ship's name displayed in the AIS was not correct with the COR. - SOLAS 09 cond. 19/2.4.5.1
Action required: 705 - Other - as specified
Due 20 January 2012
Resolved 20 January 2012
Resolution: Reviewed and accepted proper correction to the AIS information. Chief Mate corrected ship''s name in the AIS.
Navigation › Piloting/Steering › Gyro Compass
Issued 17 December 2011 Resolved
The Gyro Compass was reported as not operational
Action required: 17 - Rectify deficiencies prior to departure
Due 17 December 2011
Resolved 17 December 2011
Resolution: Received tech reports from Sperry Marine. The reports stated the Gyro Compass was repaired, tested and found operating satisfactory. Cleared the COTP Orders.
Navigation › Piloting/Steering › Gyro Compass
Issued 13 September 2011 Resolved
The gyro compass was reported not operational
Action required: 17 - Rectify deficiencies prior to departure
Due 13 September 2011
Resolved 13 September 2011
Resolution: Received a tech report from Sperry Marine. The report stated the gyro compass was repaired, tested and found operating satisfactory. Cleared the COTP Order.
Electrical › Electric Generation Source (emergency) › Generator
Issued 21 July 2008 Resolved
Emergency Generator is unable to automatically start upon loss of power from ship. E/G's primary and secondary starting mechanisms are inoperable. Class and USCG to attest to proper operation of E/G. SOLAS 74 (04) II-1/42.3.1.2 Rec'd class rpt 22JUL08 imposing condition of class until 08AUG08 - see scanned class rpt in documents for details.
Action required: 705 - Other - as specified
Due 8 August 2008
Resolved 30 August 2008
Resolution: Reviewed class survey completed by BV rectifying deficiency. Report stated: automatic start damaged relay renewed, repaired and tested satisfactorily, during black out simulation.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 21 July 2008 Resolved
Oil content meter alarm does not operate at 15ppm as intended and automatic stopping device (pump) does not secure when oil is recognized while operating the oil water separator, resulting in the possible discharge of oil at sea. Class and USCG to attest to the proper operation of the OWS content meter and stopping device prior to departure. MARPOL 73/78 Ann I/14.7
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 July 2008
Resolution: Received technician and class report attesting to the proper operation of the OWS in regards to the automatic stopping of the bilge pump at 15ppm as well as the alarm.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 21 July 2008 Resolved
Due to the third mate not having a valid flag state endorsement as required by STCW 95 I/10.5, the vessel is no longer in compliance with the minimum safe manning requirements. Flag to attest that vessel is in compliance with the minimum safe manning document. SOLAS 74 (04) V/14.1 STCW 95 I/10.5 STCW 95 I/2.5
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 July 2008
Resolution: Received flag state dispensation letter attesting to the validity of third mates flag state endorsement. Copy of endorsement is on board until original arrives to vessel.
Operations/Management › Vessel Safety Management › Reports and Analysis
Issued 21 July 2008 Resolved
Deficiencies noted appear to represent a breakdown in the vessel's SMS. Vessel's SMS requires all non-conformities to be reported on a non-conformity report. Vessel did not report the OWS as inoperable. The C/E was aware of the inoperable OWS and E/G upon arriving onboard and completed no report. It is recommended that an ISM audit be completed. SOLAS 74 (04) IX/3.1
Action required: 705 - Other - as specified
Due 30 July 2008
Resolved 28 July 2009
Resolution: A complete survey of the Safety Management System was completed on 28 Jul 2009 rectifying deficiency.
Stability › Watertight Integrity › General
Issued 21 July 2008 Resolved
Skin valve for oily water separator discharge line is leaking by when valve is completely closed, at approximately two and half (2 1/2) gallons per hour. Class to attest to the water tight integrity in way of the OWS skin valve. ILLC 66 Annex I/22
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 July 2008
Resolution: Received class report attesting to the repair of the skin valve that is now leaking by at a rate of 8 drops a minute.
Lifesaving › Inflatable Liferafts › Float Free
Issued 21 July 2008 Resolved
Vessel's four (4) inflatable life rafts are not in a float free arrangement. The sea painters are fastened to the vessel and not the hydrostatic release's weak link. Class to attest to the operational readiness of the inflatable life rafts. SOLAS 74 (04) III/20.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 July 2008
Resolution: Received class report attesting to the proper arrangement of the inflatable life rafts sea painter being tied to the weak link on the hydrostatic release.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 21 July 2008 Resolved
Fire door leading to engine space on main deck from crew's changing room to auxiliary boiler room, is missing the latching mechanism enabling the self closing door to properly close. Class to attest to the proper operation of the fire door as designed. SOLAS 74 (04) II-2/14.2.1.1.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 July 2008
Resolution: Received class report attesting to the replacement of the latching mechanism and proper operation of the self closing door.
Navigation › Collision/Grounding Avoidance › Radar
Issued 8 October 2006 Resolved
Secondary Radar and ARPA is inoperable. Repair/ Replace in the Port of San Nicolas, Argentina.
Condition: Damaged By Earlier Event
Action required: 15 - Rectify deficiencies by next port
Resolved 1 January 2007
Resolution: Received satisfactory tech report and tested unit during PSC safety exam.
Lifesaving
Issued 19 July 1998 Resolved
FAX REPORT OF LIFE RAFT SERVICE REPORT TO MSO TAMPA (U.S.COAST GUARD)
Condition: Unknown
Due 19 July 1998
Resolved 19 July 1998
Lifesaving
Issued 19 October 1994 Resolved
CONDUCTED PORT STATE CONTROL BOARDING, FOUND PAINT STORED IN STEERING ROOM.REQUESTED THE PAINT BE MOVED TO THE PAINT LOCKER.
Condition: Unknown
Due 15 May 1995
Resolved 15 May 1995
Fire Fighting
Issued 19 October 1994 Resolved
CONDUCTED PORT STATE CONTROL BOARDING, DURING TESTING OF THE EMERGENCY FIREPUMP, LEAKS WERE DISCOVERED ON THE MAIN DECK FROM FLEX(DRESS)FITTINGS.
Condition: Unknown
Due 15 May 1995
Resolved 15 May 1995
Navigation
Issued 3 February 1993 Resolved
BA CHART 899 NOT CORRECTED TO DATE.
Condition: Unknown
Due 4 February 1993
Resolved 3 February 1993

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.