← All vessels
STARLITE SAPPHIRE
Passenger (Inspected) · Passenger Ship class · Built 2000s · USCG Southeast District (CGD-SE) · Other hulls named STARLITE SAPPHIRE
STARLITE SAPPHIRE is a 2000 passenger vessel (inspected). The Coast Guard has recorded 64 inspections since 2000, most recently in January 2026, along with 141 deficiencies, 1 operational control and 7 casualty investigations between 2005 and 2017.
Records from 2000 to 2026. Most recent: inspection, 8 January 2026.
- Built
- 2000
- Last inspected
- 8 January 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 141 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 7 investigations · 2005–2017
Identity
1093860
WDG5513
3568
Flag
UNITED STATES
367547410
Maury page id
psix-3568
Inspections, by type
…with no type recorded11
Years with a record
22 calendar years (2000–2026)
The 64 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)99.5 ft × 22.0 ft × 6.0 ft
Registered tonnagegross 82 / net 56
ITC dimensions (L × B × D)99.5 ft × 22.0 ft × 6.0 ft
ITC tonnagegross 220 / net 74
BuilderMID CITY STEEL FABRICATING INC · LA CROSSE, WI, UNITED STATES · built 2000
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portST PETERSBURG, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 17 August 2026 · expires 31 August 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it82 - Regulatory (Subpart C or D), Gross Ton
220 - Convention (Subpart B), Gross Ton
56 - Regulatory (Subpart C or D), Net Ton
74 - Convention (Subpart B), Net Ton
220 - Convention (Subpart B), Gross Ton
56 - Regulatory (Subpart C or D), Net Ton
74 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDG5513MMSI 367547410 · active · compulsorily equipped · granted 9 July 2022, expires 28 September 2032
WDF2222MMSI 367426220 · expired · compulsorily equipped · granted 24 September 2009, cancelled 30 November 2019
WCZ8768MMSI not assigned · expired · compulsorily equipped · granted 14 June 2000, cancelled 14 August 2010 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 64
8 January 2026
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8286084
4 September 2025
Deficiency Check · Drydock Exam · Hull Examination · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8141960
8 January 2025
Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8041851
11 January 2024
Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7843086
15 September 2023
Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7752741
12 April 2023
Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7666989
11 October 2022
Deficiency Check · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7517870
27 April 2022
In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7433938
11 January 2022
Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7345627
15 December 2021
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7345617
21 July 2021
In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7255370
14 December 2020
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7111791
10 December 2019
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6860829
14 January 2019
Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6871149
6 January 2019
DAPI Audit · Deficiency Check · Examination of Repairs · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6606076
18 September 2018
Internal Structural Exam · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6520724
15 December 2017
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6326695
27 September 2017
COI Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6276457
14 September 2017
Deficiency Check · Administrative Inspection · Examination of Repairs · Damage Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6173761
11 September 2017
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6269480
25 October 2016
DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6009663
6 September 2016
Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5993638
25 February 2016
Damage Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5822514
25 February 2016
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5827220
16 November 2015
DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5764494
21 October 2014
Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5009094
17 March 2014
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4818521
16 December 2008
DAPI Audit
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3381840
2 December 2008
Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3372905
21 July 2008
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3277476
17 January 2008
Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3147961
10 September 2007
Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3054514
6 July 2007
Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2985522
2 July 2007
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2980998
15 June 2007
Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2962482
4 May 2007
COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2922248
3 August 2006
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2734609
18 July 2006
Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2716949
27 June 2006
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2692960
28 September 2005
Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2503179
23 September 2005
Type not recorded
No type recorded · USCG Northeast District (dpb) · USCG Northeast District (CGD-NE) · Activity 2499375
9 August 2005
Deficiency Check · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2457203
12 July 2005
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2425463
9 July 2005
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2427862
26 April 2005
Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2343430
18 November 2004
Hull Examination · Internal Structural Exam
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2243680
18 August 2004
Deficiency Check · Annual Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2169696
12 March 2004
Administrative Inspection
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2023305
29 January 2004
Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1996825
17 October 2003
Damage Survey
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1930510
16 October 2003
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2159635
26 August 2003
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1923072
22 August 2003
Deficiency Check · Annual Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1883870
6 March 2003
Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1753281
14 November 2002
Hull Examination · Internal Structural Exam
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1702398
26 June 2002
Administrative Inspection
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1658309
7 August 2001
Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1449494
18 June 2001
COI Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1472560
14 March 2001
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1060460
16 February 2001
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1058502
24 May 2000
Initial Certification
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1458757
18 May 2000
Type not recorded
No type recorded · Station Atlantic City · USCG East District (CGD-E) · Activity 1514419
13 April 2000
Initial Construction-Excluding Oversight · Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1454794
11 April 2000
Inclining Experiment
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 816798
Deficiency record · 141
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 January 2026
Resolved
Independent fuel tanks must be designed and constructed as to meet material and construction standards. MI observed fuel tank in bow thruster room containing diesel without documentation specifying the standard to which the tank meets. Provide evidence of the standard for the fuel tank.
46CFR182.440(a)
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 8 January 2026
Resolved
Each floating waterlight must be approved in accordance with subchapter Q. MI observed floating waterlight attached to ring buoy with unapproved battery installation. Unapproved Alkaline batteries must be removed and the specified Lithium Batteries must be installed.
46CFR180.70(d)(1)
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 January 2026
Resolved
Electrical equipment must be installed and maintained to Protect passengers, crew, other persons, and the vessel from electrical hazards. MI observed stbd fwd deck light on top of pilot house allowing water intrusion affecting wiring inside junction box.
46CFR183.200
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 8 January 2026
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. MI observed raw water leak on No. 2 generator. Repair leak.
46CFR182.100
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 8 January 2026
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. MI observed oil leak on Stbd engine at oil filters. Repair leak.
46CFR182.100
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 8 January 2026
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. MI observed fuel leak on Port engine. Repair leak.
46CFR182.100
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 January 2025
Resolved
46CFR185.604(h)
705 c
Each life jacket must be marked with Type I retro reflective material approved in 46 CFR 164.018. Inspector observed 6 adult and 01 child life jackets not sufficiently marked with retro reflective tape. Passenger count reduced until resolved.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 January 2025
Resolved
46CFR176.808(a)(2)
705c
At each initial and subsequent inspection for certification of a vessel, the owner shall be prepared to have the vessel ready for inspection of lifesaving equipment and systems, including inspection of each marine buoyant device. Inspector observed improper installation of mounting bracket to secure water light.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 January 2025
Resolved
46CFR185.604(i)
705c
Each rescue boat and ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018. Inspector observed missing retroreflective material.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 January 2025
Resolved
46CFR176.804(c)
16c
At each subsequent inspection for certification, the owner shall be prepared to have the vessel ready for inspections of machinery, fuel, and piping systems, including inspection of all machinery essential to the routine operation of the vessel including generators. Inspector observed raw water hose cracking on fwd generator.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 January 2025
Resolved
46CFR176.800(a)
16c
Machinery, equipment, materials, and arrangements may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. Inspector observed STBD MDE fuel supply line corroded and requires replacement.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 January 2025
Resolved
46CFR176.800(a)
16c
Machinery, equipment, materials, and arrangements may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. Inspector observed exhaust manifold missing bolt.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 January 2025
Resolved
46cfr176.800(a)
16c
Machinery, equipment, materials, and arrangements may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. Inspector observed port MDE fuel filter housing not properly attached.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 January 2025
Resolved
46CFR179.320(c)
16c
A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. Inspector observer penetration in bulkhead not watertight.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 January 2025
Resolved
46CFR176.800(a)
16c
Machinery, equipment, materials, and arrangements may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. Inspector observed engine room house keeping not IAW good marine practice.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 8 January 2025
Resolved
46CFR183.410(c)(1)
16c
Each fixture must comply with § 183.200. Inspector observed light fixture not operational.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 8 January 2025
Resolved
46CFR176.818
16c
At each inspection for certification, toilet and washing spaces, galleys, serving pantries, lockers, and similar spaces may be examined to determine that they are serviceable and in a sanitary condition. Inspector observed galley and similar spaces were not in sanitary condition.
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 8 January 2025
Resolved
46CFR176.800(a)
50c
A vessel is inspected for compliance with the standards required by this subchapter. Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. Inspector observed AC accumulator tank not properly secured IAW good marine practice.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 11 January 2024
Resolved
A pre-engineered fixed gas fire extinguishing system must be installed in accordance with the manufacturer's instructions.
Pre-engineered system storage cylinder gauge in the the bow thruster space is in the red indicating the storage cylinder is not sufficiently charged.
Bow thruster is not to be used until the cylinder is recharged or replaced.
46 CFR 181.420(a)(4)
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 January 2024
Resolved
The minimum number of portable fire extinguishers required on a vessel must be acceptable to the OCMI.
40-B:C fire extinguisher gauge in the main salon locker is in the the red indicating the bottle is not sufficiently charged; extinguisher must be replaced.
46 CFR 181.500(a)
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 January 2024
Resolved
Portable fire extinguisher installation and location must be to the satisfaction of the [name withheld] fire extinguisher in the galley is not mounted; extinguisher to be properly mounted.
46 CFR 181.500
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 11 January 2024
Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail
Starboard propulsion engine attached pump belt is not protected by a guard. Install guard around belt and pulleys.
46 CFR 177.960
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 January 2024
Resolved
Each distribution panel or switchboard must be totally enclosed and of the dead front type.
Breaker panel in potable water tank space does not have a door or cover. Install door onto panel.
46 CFR 183.330(b)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 April 2023
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from machinery failure, and personnel injury.
Vessel reported loss of propulsion of stbd engine resulting in allision with pier.
Provide damage assessment and proof of proper system operation for CG review and approval prior to carrying passengers.
46 CFR 182.100
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 October 2022
Resolved
The main engine exhaust piping must be properly supported by noncombustible hangers or blocks.
The port main diesel engine exhaust piping was found installed without supports or hangers.
46 CFR 182.43(b)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 October 2022
Resolved
Nonmetallic hose may be used for wet exhaust systems provided it is double clamped.
The port main diesel engine flexible exhaust hose was found with only one hose clamp attached.
46 CFR 182.43(e)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 October 2022
Resolved
Gauges to indicate engine jacket water discharge temperature must be provided for all propulsion engines installed in the vessel.
The port main diesel engine jacket water temp gauge was found inoperable during an test of the main propulsion system.
46 CFR 182.410(b)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 October 2022
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements.
MI observed dry rot, cracking and wear on the starboard main engine alternator drive belt.
46 CFR 182.200(a)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 October 2022
Resolved
Electrical equipment on a vessel must be installed and maintained to protect persons and the vessel from electrical hazards.
MI observed the positive conductor on the starboard generator starter with sharp bends and a loose connection.
46 CFR 183.220(b)
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 October 2022
Resolved
Electrical equipment on a vessel must be installed and maintained to protect persons and the vessel from electrical hazards.
MI observed the ground conductor with loose connections at the ground bus inside of the switchboard.
46 CFR 183.220(b)
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 11 January 2021
Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system.
Identified both port and starboard closures need to be adjusted to make complete closure of the devices.
46 CFR 182.465(h)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 11 January 2021
Resolved
Where flexibility is necessary, a section of flexible metallic hose may be used. Nonmetallic hose may be used for wet exhaust systems provided it is especially adapted to resist the action of oil, acid, and heat, has a wall thickness sufficient to prevent collapsing or panting, and is double clamped where practicable.
Identified nonmetallic hose dripping from the #2 generator exhaust piping where it was hose clamped from both ends.
46 CFR 182.430(e)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 14 January 2019
Resolved
The Weather deck on a flush deck vessel must be watertight.
Submit proposal for crop out and renew of corrosion found on the aft port side weather deck stairs.
46CFR178.410(a)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 January 2019
Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended.
Forward generator is leaking coolant during operation.
Repair coolant leak and bring generator back to designed operation prior to placing in service. 46 CFR 182.100
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 18 September 2018
Resolved
Permanently repair wastage on overhead, located in starboard side liquor hold, as accepted in approved repair proposal created 20SEP2018.
IAW: 46CFR115.610 (b)
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 16 October 2017
Resolved
05 PFDs' unserviceable. 46 CFR 180.71(a) Reduced to 145 passengers.
Engineering › Bilge Water Management System › Strainer
Issued 16 October 2017
Resolved
Bilge suction strainer in E/R was wasted and holed. Replace. 46 CFR 182.510(b)
Operations/Management › Drills/Instruction › Abandon Ship
Issued 16 October 2017
Resolved
Vessel's abandon ship instructions did not task any crew member or specify who is assigned to the retrieval of the EPRIB when abandoning ship. Add to WQSB.
Operations/Management › Drills/Instruction › Flooding Mitigation
Issued 16 October 2017
Resolved
Bilge manifold diagram in E/R confusing and does not correspond to actual bilge configuration. Renew instructions and diagram for dewatering to reflect actual mainfold set up. 46 CFR 176.800(a)
Construction/Loadline › Hull › Hull Plating
Issued 14 September 2017
Resolved
Puncture in hull present strbd side of bow post allision with seawall. Repair to satisfaction of the Marine inspector. 46CFR176.802
Construction/Loadline › Hull › Hull Plating
Issued 14 September 2017
Resolved
Properly crop out and renew all damaged areas of bow, IAW submitted repair proposal.
Construction/Loadline › Structures › Deck Plating
Issued 14 September 2017
Resolved
Properly crop out & renew main deck IWO the bow, IAW repair proposal.
Construction/Loadline › Structures › Superstructure
Issued 14 September 2017
Resolved
Crop out & renew square bracket on inner side of bulwark, IAW repair proposal.
Construction/Loadline › Structures › Superstructure
Issued 14 September 2017
Resolved
Crop out & renew wasted steel on the aft side of chain locker, IAW repair proposal.
Construction/Loadline › Structures › Superstructure
Issued 14 September 2017
Resolved
Crop & renew damaged areas of aft/01 deck cap rail, radius corner, bulkhead, handrails & bulwarks, IAW repair proposal.
Construction/Loadline › Hull › Longitudinal Frame
Issued 14 September 2017
Resolved
Crop out or grind down end of deck longitudinal, located aft void, where hull deflection contacts the end of the longitudinal, for further CG examination.
Stability › Weathertight Integrity › General
Issued 7 September 2016
Resolved
Crop and renew wasted and holed steel window frames port side forward main deck prior to credit hull.
Construction/Loadline › Structures › Deck Plating
Issued 7 September 2016
Resolved
Remove scale from deck plating located in forward life jacket locker port side and make available for inspection. Crop and renew wasted and holed deck plating as identified.
Construction/Loadline › Hull › Hull Plating
Issued 25 February 2016
Resolved
Prior to carrying passengers, provide attending MI with copy of diver's report following accidental grounding.
Engineering › Bilge Water Management System › Strainer
Issued 16 November 2015
Resolved
Ensure all bilge suctions are fitted with a suitable strainer IAW 46 CFR 182.510 (b).
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 16 November 2015
Resolved
Ensure all portable fire extinguishers are properly serviced and mounted IAW 46 CFR 181.500.
Fire Fighting › Fixed Fire Detection System › Annual Inspection
Issued 16 November 2015
Resolved
Fixed fire fighting system must be annually serviced. Provide annual servicing for engine space and galley IAW 46 CFR 181.410.
Stability › Watertight Integrity › General
Issued 16 November 2015
Resolved
Ensure watertight integrity in all watertight bulkheads IAW 46 CFR 179.320 (c).
Engineering › Steering Gear System › Rudder Stock
Issued 21 October 2014
Resolved
Rudder stop is worn down and needs to be replaced.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 21 October 2014
Resolved
EPIRB HPU expired September of 2014. O/O stated he would purchase same day.
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 16 December 2008
Resolved
Drug testing background checks must be conducted for all new crewmembers who have previously worked for a DOT regulated employer. Provide a copy of the form to be used to the D1 DAPI. Req. found in 49CFR40.25.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 16 December 2008
Resolved
2008 MIS report must be filed NLT March 15, 2008. Previous reports have not been filed.
Fire Fighting › Fixed Halon Fire Extinguishing System › Tanks
Issued 2 December 2008
Resolved
Vessel's bow thruster room fixed fire fighting system is inoperative. Bow thruster is not to be used until the fixed firefighting system is repaired and installed. Starting batteries must be removed from the space prior to carrying passengers.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 2 December 2008
Resolved
Weld hand rail starboard side, aft on stern.
Lifesaving › Lifefloat › Serviceable
Issued 21 July 2008
Resolved
Clean all lifefloats and replace worn retroreflective tape as needed.
Lifesaving › Lifefloat › Pendant
Issued 21 July 2008
Resolved
Replace all pendants on all lifefloats with 12' line.
Construction/Loadline › Structures › Superstructure
Issued 21 July 2008
Resolved
Replaced cracked window on main deck.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 21 July 2008
Resolved
Provide means to shut down aft generator in the event of a CO2 discharge. Vessel is restricted to forward generator until this deficiency is cleared.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 4 May 2007
Resolved
Complete annual servicing
Lifesaving › Buoyant Apparatus › Retroreflective Material
Issued 4 May 2007
Resolved
Provide New Retro reflective material.
Lifesaving › Lifefloat › Paddle
Issued 4 May 2007
Resolved
Provide new paddles
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 4 May 2007
Resolved
Replace batteries for all waterlights
Lifesaving › Hand Flares › Quantity
Issued 4 May 2007
Resolved
Provide 6 orange smoke/ 6 red handheld flares or 12 hand held flares
Engineering › Lubricating Oil Service System › Gauge
Issued 4 May 2007
Resolved
Prepair or replace L/O pressure gauge for #2 generator.
Electrical › Lighting (service) › Lighting Fixture
Issued 4 May 2007
Resolved
Repair light fixture on upper WX deck.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 4 May 2007
Resolved
Provide operating instructions for engine room fire supression system
Fire Fighting › Fixed Low-Expansion Foam Fire Extinguishing System › Discharge Outlets
Issued 4 May 2007
Resolved
Clean nozzles for Galley fire supression system
Fire Fighting › Ventilation Systems › Fans
Issued 4 May 2007
Resolved
Clean Fans in galley
Fire Fighting › Ventilation Systems › Fans
Issued 4 May 2007
Resolved
Clean Fans in galley
Lifesaving › Lifefloat › Markings
Issued 4 May 2007
Resolved
Stencil life float with vessel name
Navigation › Piloting/Steering › Compass Deviation Table
Issued 4 May 2007
Resolved
Provide updated deviation table
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 4 May 2007
Resolved
Provide emergency eye wash
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 4 May 2007
Resolved
Post emergency instructions
Navigation › Piloting/Steering › Marine Charts
Issued 26 June 2006
Resolved
Provide a current marine chart for area of operation.
Communications › Alarms/Indicators › General Alarm
Issued 26 June 2006
Resolved
Prove proper operation of public address system.
Lifesaving › Buoyant Apparatus › Marking
Issued 26 June 2006
Resolved
Label lifefloat paddles with vessel name.
Lifesaving › Buoyant Apparatus › Marking
Issued 26 June 2006
Resolved
Relabel lifefloats with max persons number.
Electrical › Lighting (service) › Outlet Box
Issued 26 June 2006
Resolved
Repair electrical connection box to roof floodlight port side forward.
Operations/Management › Navigation Safety › Persons Allowed in Pilothouse/Navigation Bridge
Issued 26 June 2006
Resolved
Repair locking enclosure to stbd bridge wing propulsion controls.
Engineering › Fuel Oil Service System › Valve, Control
Issued 26 June 2006
Resolved
Prove proper operation of remote fuel shut-off for bow thruster engine.
Construction/Loadline › Penetrations › Bottom Plug Packing
Issued 26 June 2006
Resolved
Reduce port shaft packing leakage.
Construction/Loadline › Penetrations › Bottom Plug Packing
Issued 26 June 2006
Resolved
Renew stbd shaft packing.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 26 June 2006
Resolved
Replace stbd shaft guard.
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 June 2006
Resolved
Clean all electrical equipment in engine room of grinding dust.
Navigation › Collision/Grounding Avoidance › Danger Messages
Issued 26 June 2006
Resolved
Provide one orange smoke.
Communications › Radio Communications › EPIRB
Issued 9 August 2005
Resolved
Prove current servicing, battery replacement & labeling of EPIRB. Vessl restricted to 3 miles offshore until this deficiency is cleared.
Electrical › Lighting (service) › Outlet Box
Issued 9 August 2005
Resolved
Renew damaged receptacle cover at wheelhouse.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 9 August 2005
Resolved
Repair machinery guard on bow thruster engine.
Engineering › Bilge Water Management System › Not Operational
Issued 9 August 2005
Resolved
Prove proper operation of bilge alarm system (voids 2 & 3).
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 18 November 2004
Resolved
Repaint draft markings fore & aft prior to floating vessel.
Construction/Loadline › Hull › Hull Plating
Issued 18 November 2004
Resolved
Prime/paint coatings in tank room as needed.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 18 November 2004
Resolved
Install securing device to bow thruster engine fuel fill cap.
Communications › Radio Communications › EPIRB
Issued 18 November 2004
Resolved
Replace EPIRB hydrostatic release.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 18 August 2004
Resolved
Label pull station for engine room fixed fire fighting system.
Engineering › Sea-water System (primary cooling) › Piping
Issued 18 August 2004
Resolved
Repair leaks at all unions to aft generator sea water system piping.
Communications › Radio Communications › EPIRB
Issued 18 August 2004
Resolved
Renew EPIRB registration and train all masters on testing and logging procedures. Vessel restricted to Lakes, Bays & Sounds route until this deficiency is cleared.
Navigation › Piloting/Steering › Marine Charts
Issued 18 August 2004
Resolved
Provide current marine chart for area of operation.
Pollution Prevention/Response › Prevention Equipment › Garbage Grinder/Comminuter
Issued 18 August 2004
Resolved
Post MARPOL V placard in galley area.
Operations/Management › Casualty Reporting/Post-Casualty Actions
Issued 17 October 2003
Resolved
Submit form CG-2692 to USCG by 21Oct03 in regards to and detailing events of E/R fire on 16Oct03. LEGACY COMPONENT DESC: Filing Written Report of Marine Casualty
Electrical › Electric Generation Source (service)
Issued 17 October 2003
Resolved
Replace both stbd MDE starting batteries and one battery box. Prove proper operation of stbd MDE with 3 successive starts. LEGACY COMPONENT DESC: Number of Sources
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 17 October 2003
Resolved
Replace one A-II portable fire extinguisher, currently serviced. LEGACY COMPONENT DESC: Condition
Documentation › Logs/Records
Issued 17 October 2003
Resolved
Make deck log entry describing events of 16Oct03. LEGACY COMPONENT DESC: Logbook/Record (unofficial)
Deck/Cargo › Mooring/Anchoring
Issued 22 August 2003
Resolved
Prove proper operation of electric anchor windlass. LEGACY COMPONENT DESC: Winch
Accommodation/Occupational Safety › Ventilation
Issued 22 August 2003
Resolved
Replace broken window on main deck port side. LEGACY COMPONENT DESC: Window
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 22 August 2003
Resolved
Prove current servicing and repair sensing circuit to bow thruster room fixed fire extinguishing system (do not use with pax on board). LEGACY COMPONENT DESC: Tanks
Accommodation/Occupational Safety › Ventilation
Issued 22 August 2003
Resolved
Prove proper operation of E/R vent closures (no pax operations until cleared). LEGACY COMPONENT DESC: Closures
Construction/Loadline › Penetrations
Issued 22 August 2003
Resolved
Adjust port shaft packing to acceptable leak limit. LEGACY COMPONENT DESC: Shaft
Engineering › Compressed Air System (control)
Issued 14 November 2002
Resolved
Provide name plate data and relief valve setting for air compressor in USCG. LEGACY COMPONENT DESC: Receiver/Bottle
Lifesaving
Issued 18 June 2001
Resolved
provide rescue procedures for man overboard and abandon ship. Move the ladder to the third deck to the overhead IWO hatch.
Lifesaving
Issued 18 June 2001
Resolved
Mount donning instructions for life jackets.
Documentation
Issued 18 June 2001
Resolved
Provide C.O.I
Accommodation/Occupational Safety
Issued 18 June 2001
Resolved
Remove griddle or provide fire protection system.
Engineering
Issued 18 June 2001
Resolved
prove proper operation of fuel shut offs. (engine room and bow thurster)
Fire Fighting
Issued 18 June 2001
Resolved
Remove plastic trash cans.
Accommodation/Occupational Safety
Issued 18 June 2001
Resolved
Clean out #3 hold for access and crew safety.
Construction/Loadline
Issued 18 June 2001
Resolved
Stop port shaft log excessive leaking.
Lifesaving
Issued 18 June 2001
Resolved
lable all lifesaving equipment with new vessel name.
Lifesaving
Issued 14 March 2001
Resolved
DEMONSTRATE MAN OVERBOARD RESCUE PROCEEDURE TO COAST GUARD MARINE INSPECTORUPON ARRIVAL TO NEW OPERATING AREA.
Fire Fighting
Issued 16 February 2001
Resolved
SERVICE HALON SYSTEM IN ENGINE ROOM.
Accommodation/Occupational Safety
Issued 16 February 2001
Resolved
REMOVE GRIDDLE FROM THE VESSEL PRIOR TO CARRYING PASSENGERS FOR HIRE OR INSTALL IN ACCORDANCE WITH REGULATIONS.
Fire Fighting
Issued 24 May 2000
Resolved
PROVIDE ONE B-II/C-II CO2 PORTABLE FIRE EXTINGUISHER FOR ENGINE ROOM.
Documentation
Issued 24 May 2000
Resolved
PROVIDE STABILITY LETTER FOR THE VESSEL, ON BOARD THE VESSEL.
Fire Fighting
Issued 24 May 2000
Resolved
PROVIDE ADEQUATE SIZE FIXED FIRE EXTINGUISHING SYSTEM FOR BOW THRUSTER COMPARTMENT.
Lifesaving
Issued 24 May 2000
Resolved
PROVIDE PROOF OF EPRIB REGISTRATION WITH NOAA.
Fire Fighting
Issued 24 May 2000
Resolved
PROVIDE VOLUME CALCUALTIONS FOR BOW THRUSTER COMPARTMENT.
Fire Fighting
Issued 24 May 2000
Resolved
PROVIDE MANUFACTURERS SPECIFICATIONS FOR FIXED CO2 SYTEM PIPING, INCLUDING MINIMUM MELTING POINT AND MINIMUM BURST PRESSURE. CURRENTLY INSTALLED PIPING IS ASTM A312/ASME SA-312 CMI SCH 40S.
Accommodation/Occupational Safety
Issued 24 May 2000
Resolved
MARK UPPER DECK MAX CAPACITY IAW STABILITY LETTER.
Navigation
Issued 24 May 2000
Resolved
PROVIDE PROOF OF VALID FCC RADIO SAFETY CERTIFICATE; VESSEL IS RESTRICTED TO NO MORE THAN 1000 FT FROM SHORE UNTIL PROOF IS PROVIDED TO THE ATTENDINGMARINE INSPECTOR.
Documentation
Issued 24 May 2000
Resolved
RESOLVE OUTSTANDING PLAN REVIEW AND STABILITY PROBLEMS WITH MSC. UNTIL THIS 835 IS CLEARED, VSL MAY OPERATE ONLY ON A RIVERS ROUTE WITH NO MORE THAN 100 PASSENGERS ON BOARD, AND NO PASSENGERS ON THE UPPER DECK. MSC POCIS LISA HECKER AT [phone withheld].
Unknown
Issued 24 May 2000
Resolved
SUBMIT CG-2692 FOR LOSS OF RUDDERS.
Electrical
Issued 24 May 2000
Resolved
PROPERLY INSTALL A FLOOD LIGHT FOR THE AFT RESCUE DECK.
Navigation
Issued 24 May 2000
Resolved
ADJUST RUDDER POST AND COLLAR ON STBD SIDE RUDDER.
Navigation
Issued 24 May 2000
Resolved
PROVIDE PROOF OF VALID FCC STATION LICENCE; VESSEL RESTRICTED TO NO MORE THAN 1000 FT FROM SHORE UNTIL PROOF IS PROVIDED TO THE ATTENDING MARINE INSPECTOR.
Navigation
Issued 13 April 2000
Resolved
PROVIDE ALL REQUIRED CHARTS AND PUBLICATIONS FOR OPERATING AREAS, PRIOR TO TAKING PASSENGERS FOR HIRE.
Lifesaving
Issued 13 April 2000
Resolved
MARK LIFE SAVING EQUIPMENT AS PER 46CFR185.604. (RING BUOYS, LIFE FLOATS)
Lifesaving
Issued 13 April 2000
Resolved
CONDUCT FIRE AND PERSON OVERBOARD DRILLS WITH ASSIGNED CREW PRIOR TO TAKINGPASSENGERS FOR HIRE.
Casualty record · 7
9 July 2005Routine · role: Involved in a Marine Casualty · at COS COB RAILROARD BRIDGE · activity 2427862
12 July 2005Routine · role: Involved in a Marine Casualty · at COS COB RAILROARD BRIDGE · activity 2425463
2 July 2007Routine · role: Involved in a Marine Casualty · activity 2980998
22 March 2011Routine · role: Involved in a Marine Casualty · at MIANUS RIVER RR BRIDGE · activity 3970344
25 February 2016Routine · role: Involved in a Marine Casualty · activity 5827220
11 September 2017Routine · role: Involved in a Marine Casualty · activity 6269480
15 December 2017Routine · role: Involved in a Marine Casualty · 1 injured · activity 6326695
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Recorded names · 1
CAYAH MICHELE (2005–2011). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.