Records from 2016 to 2026. Most recent: inspection, 27 February 2026.
Documentation record
Registered dimensions (L × B × D)120.4 ft × 24.0 ft × 11.4 ft
Registered tonnagegross 90 / net 61
ITC dimensions (L × B × D)120.4 ft × 24.0 ft × 11.4 ft
ITC tonnagegross 216 / net 64
BuilderBREAUX'S BAY CRAFT INC · LOREAUVILLE, LA, UNITED STATES · built 1990
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portWILMINGTON, DE
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 27 February 2026 · expires 31 March 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it90 - Regulatory (Subpart C or D), Gross Ton
216 - Convention (Subpart B), Gross Ton
61 - Regulatory (Subpart C or D), Net Ton
64 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 23
27 February 2026
COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8318501
25 June 2025
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8168562
17 June 2024
Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7926854
12 March 2024
Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7871771
20 October 2023
Damage Survey · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7811773
11 April 2023
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7654551
7 March 2023
In-Service Inspection · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7652570
1 August 2022
Deficiency Check · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7498480
16 May 2022
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7451709
20 April 2021
COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7175001
8 April 2020
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6936837
3 April 2020
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6929551
3 April 2020
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6935332
3 April 2020
Damage Survey · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6936273
12 March 2020
Plan Review "T" Boat
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6924996
27 January 2020
Internal Structural Exam · Plan Review "T" Boat · Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6889551
1 August 2019
Administrative Inspection · Liferaft Servicing
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6759894
23 April 2019
COI Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6658146
3 April 2018
Internal Structural Exam · Annual Inspection · Drydock Exam
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6384381
24 April 2017
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6131798
7 April 2017
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6119803
20 April 2016
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5857545
11 April 2016
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5851577
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 17 June 2024
Resolved
A hinged watertight bulkhead door must be fitted with a quick actin closing devise operable from both sides of the door and indicator lights at the operating station showing whether the door is open or closed. The indicator light for the door to the generator space was inoperable.
Action required: 10 - Deficiency Rectified
Resolved 17 June 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 October 2023
Resolved
PROPULSION MACHINERY MUST BE SUITABLE FOR SERVICE AND CAPABLE OF PERATING AT CONSTANT MARINE LOAD. NO.4 MDE HAS A COMPRESSION LEAK GETTING INTO THE COOLING SYSTEM, OVERPRESSURIZING COOLING SYSTEM. CORRECT TO SATISFACTION OF [name withheld] OR CARRIAGE OF PASSENGERS OR OFFSHORE WORKERS.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 October 2023
Resolution: See Activity Number 7811773
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 11 April 2023
Resolved
VHF Radio does not have DSC set up.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 April 2023
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 1 August 2022
Resolved
No vessel subject to inspection will be navigated unless it is under the direction and control of an individual who holds an appropriate license. Master not available for inspection of vessel. Provide master holding proper MMC.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 August 2022
Resolution: Provided. All sat.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 1 August 2022
Resolved
No marine employer shall employ any individual to serve as a crew member unless the individual passes a chemical test for dangerous drugs. Crew for vessel currently not employed. Provided pre-employment and enrollment in random testing program.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 August 2022
Resolution: Documents provided. All sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 August 2022
Resolved
The master shall conduct drills and give instructions as necessary to ensure that all crew members are familiar with their duties. Crew for vessel currently not employed. Drills not conducted. 46 CFR 185.25-10
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 August 2022
Resolution: Drills conducted and documented. All sat.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 1 August 2022
Resolved
Power fire pump. The power fire pump shall be selfpriming and of such size as to discharge an effective stream from a hose connected to the highest outlet. Unable to test fire pump due to leak in piping in machinery room. Make repairs to piping and make pump available for testing. 46 CFR 181.10-1
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 12 August 2022
Resolution: Repairs made. Fire main and pump tested. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 April 2021
Resolved
Piping, including valves, pipe fittings and flanges, conveying vapor, gas, or liquid, the temperature of which exceeds 65.5*C (150*F) must be suitably insulated where necessary to prevent injuries; exhaust insulation on the outboard side of Engine #2 must be replaced.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 May 2021
Resolved 26 May 2021
Resolution: replaced exhaust insulation appropriately
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 20 April 2021
Resolved
Each vessel operating on oceans, coastwise, limited coastwise, or beyond 3NM from shore upon the Great Lakes must carry a Category 1 EPIRB; EPIRB battery inoperable and must be replaced. Route limited to the boundary line of 20NM from a harbor or safe refuge.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2021
Resolved 26 May 2021
Resolution: EPIRB replaced.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 April 2021
Resolved
Vessel must be provided with a satisfactory arrangement for draining any watertight compartment; no suction for dewatering space.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2021
Resolved 26 May 2021
Resolution: verified suction is operational
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 20 April 2021
Resolved
Each vessel must have marine charts which are currently corrected; charts are out of date and have not been manually corrected.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2021
Resolved 26 May 2021
Resolution: Provided new charts for operational area
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 April 2020
Resolved
46 CFR 182.20-20
Exhaust shall be gastight throughout its length and shall be properly supported by non-combustible hangers or blocks. Exhaust piping on the port MDE has a leak. Repair to the satisfaction of CG Marine Inspector within 7 days.
Action required: 705 - Other - as specified
Resolved 8 April 2020
Resolution: Exhaust pipe was re-welded.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 3 April 2020
Resolved
46 CFR 182.20-15 & 20
Exhaust piping shall be suitably insulated. Section on the stbd MDE exhaust piping is missing lagging. Repair to the satisfaction of CG Marine Inspector within 14 days.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 April 2020
Resolution: Lagging on exhaust pipe was re-installed.
09 - Working and Living Conditions › 092 - Working Conditions › Holds and tanks safety
Issued 3 April 2020
Resolved
46 CFR 176.700
Alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant [name withheld] and receive Marine Safety Center approval for the stability effects of changing the rig water tanks to diesel tanks.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 April 2020
Resolution: MSC sent approved plan review lightship change letter and reduced cargo loading diagram.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 3 April 2020
Resolved
Repairs or alterations to the hull, machinery or equipement that affect the safety of the vessel must not be made without the approval of the OCMI, except during an emergency. Vessel reported that they puntured the hull 2" below the waterline while mooring due to a bolt sticking out from the pierface. Vessel reports that a satisfactory temporary repair has been made stopping the ingress of water. Make permanenant repairs to the satisfaction of CG Marine Inspector.
46 CFR 176.700
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 May 2020
Resolved 8 April 2020
Resolution: Vessel cropped and inserted an 18x18. Fitup, backgouge, and final weld test all sat.
Stability › Watertight Integrity › General
Issued 7 April 2017
Resolved
Electrical wire cable running through the forward engine room bulkhead needs to be watertight.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 14 April 2017
Resolved 24 April 2017
Resolution: Corrected.
Fire Fighting › Ventilation Systems › Fans
Issued 7 April 2017
Resolved
Power exhaust ventilation needs to be cleared of grime and debris to prevent motors from overheating.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 April 2017
Resolved 24 April 2017
Resolution: Corrected.
Engineering › Fuel Oil Service System › Discharge Strainer
Issued 7 April 2017
Resolved
Plastic flame screen drain plugs need to be replaced with metallic plugs.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 April 2017
Resolved 24 April 2017
Resolution: Corrected.
Lifesaving › Lifebuoys › Approval
Issued 7 April 2017
Resolved
Ring lifebuoy on the aft deck does not have approval sticker/information and needs to be removed or replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 April 2017
Resolved 24 April 2017
Resolution: Corrected.