GASPEE is a 1990 offshore supply vessel. The Coast Guard has recorded 56 inspections since 1990, most recently in February 2026, along with 32 deficiencies.

Records from 1990 to 2026. Most recent: inspection, 27 February 2026.

Built
1990
Last inspected
27 February 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDG9075
356902
Flag
UNITED STATES
367584050
Maury page id
psix-356902

Inspections, by type

…with no type recorded7
Years with a record 32 calendar years (1990–2026)
The 56 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Registered dimensions (L × B × D)120.4 ft × 24.0 ft × 11.4 ft
Registered tonnagegross 90 / net 61
ITC dimensions (L × B × D)120.4 ft × 24.0 ft × 11.4 ft
ITC tonnagegross 216 / net 64
BuilderBREAUX'S BAY CRAFT INC · LOREAUVILLE, LA, UNITED STATES · built 1990
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portWILMINGTON, DE
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 27 February 2026 · expires 31 March 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it90 - Regulatory (Subpart C or D), Gross Ton
216 - Convention (Subpart B), Gross Ton
61 - Regulatory (Subpart C or D), Net Ton
64 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDG9075MMSI 367584050 · active · compulsorily equipped · granted 27 April 2023, expires 20 July 2033
WAP9744MMSI 367078430 · expired · compulsorily equipped · granted 24 November 2005, cancelled 13 February 2016 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 56

27 February 2026 COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8318501
25 June 2025 Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8168562
17 June 2024 Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7926854
12 March 2024 Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7871771
20 October 2023 Damage Survey · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7811773
11 April 2023 Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7654551
7 March 2023 In-Service Inspection · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7652570
1 August 2022 Deficiency Check · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7498480
16 May 2022 Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7451709
20 April 2021 COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7175001
8 April 2020 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6936837
3 April 2020 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6929551
3 April 2020 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6935332
3 April 2020 Damage Survey · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6936273
12 March 2020 Plan Review "T" Boat
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6924996
27 January 2020 Internal Structural Exam · Plan Review "T" Boat · Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6889551
1 August 2019 Administrative Inspection · Liferaft Servicing
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6759894
23 April 2019 COI Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6658146
3 April 2018 Internal Structural Exam · Annual Inspection · Drydock Exam
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6384381
24 April 2017 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6131798
7 April 2017 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6119803
20 April 2016 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5857545
11 April 2016 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5851577
5 December 2011 Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4202136
9 September 2010 Hull Examination · Annual Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3858995
17 November 2008 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3364983
12 November 2008 Deficiency Check · Hull Examination · Administrative Inspection · Re-Inspection · Ballast Water Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3362192
15 November 2007 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3099310
14 November 2007 Re-Inspection · Ballast Water Examination · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3098708
11 October 2007 Damage Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3077708
7 July 2006 Ballast Water Examination · COI Inspection · Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2694284
18 November 2005 Re-Inspection · Ballast Water Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2536905
27 September 2004 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2213928
19 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1978227
18 September 2003 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1907639
19 September 2002 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1677748
28 October 2001 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 58331
20 September 2001 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1448351
27 February 2001 Examination of Repairs
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1468187
23 January 2001 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 214807
21 September 2000 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1389186
28 June 2000 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 214118
22 September 1999 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1369352
30 June 1999 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 212162
3 October 1998 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1400849
9 October 1997 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1464725
23 October 1996 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1357779
23 October 1995 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1463205
3 November 1994 Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1377296
24 October 1994 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1446137
8 November 1993 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1370734
25 November 1992 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 829010
10 November 1992 COI Inspection · Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1133529
5 May 1992 Drydock Extension
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 943121
12 November 1991 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1251600
1 December 1990 Initial Certification · Hull Examination · Initial Construction-Excluding Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1216096

Deficiency record · 32

08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 17 June 2024 Resolved
A hinged watertight bulkhead door must be fitted with a quick actin closing devise operable from both sides of the door and indicator lights at the operating station showing whether the door is open or closed. The indicator light for the door to the generator space was inoperable.
Action required: 10 - Deficiency Rectified
Resolved 17 June 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 October 2023 Resolved
PROPULSION MACHINERY MUST BE SUITABLE FOR SERVICE AND CAPABLE OF PERATING AT CONSTANT MARINE LOAD. NO.4 MDE HAS A COMPRESSION LEAK GETTING INTO THE COOLING SYSTEM, OVERPRESSURIZING COOLING SYSTEM. CORRECT TO SATISFACTION OF [name withheld] OR CARRIAGE OF PASSENGERS OR OFFSHORE WORKERS.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 October 2023
Resolution: See Activity Number 7811773
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 11 April 2023 Resolved
VHF Radio does not have DSC set up.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 April 2023
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 1 August 2022 Resolved
No vessel subject to inspection will be navigated unless it is under the direction and control of an individual who holds an appropriate license. Master not available for inspection of vessel. Provide master holding proper MMC.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 August 2022
Resolution: Provided. All sat.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 1 August 2022 Resolved
No marine employer shall employ any individual to serve as a crew member unless the individual passes a chemical test for dangerous drugs. Crew for vessel currently not employed. Provided pre-employment and enrollment in random testing program.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 August 2022
Resolution: Documents provided. All sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 August 2022 Resolved
The master shall conduct drills and give instructions as necessary to ensure that all crew members are familiar with their duties. Crew for vessel currently not employed. Drills not conducted. 46 CFR 185.25-10
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 August 2022
Resolution: Drills conducted and documented. All sat.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 1 August 2022 Resolved
Power fire pump. The power fire pump shall be selfpriming and of such size as to discharge an effective stream from a hose connected to the highest outlet. Unable to test fire pump due to leak in piping in machinery room. Make repairs to piping and make pump available for testing. 46 CFR 181.10-1
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 12 August 2022
Resolution: Repairs made. Fire main and pump tested. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 April 2021 Resolved
Piping, including valves, pipe fittings and flanges, conveying vapor, gas, or liquid, the temperature of which exceeds 65.5*C (150*F) must be suitably insulated where necessary to prevent injuries; exhaust insulation on the outboard side of Engine #2 must be replaced.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 May 2021
Resolved 26 May 2021
Resolution: replaced exhaust insulation appropriately
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 20 April 2021 Resolved
Each vessel operating on oceans, coastwise, limited coastwise, or beyond 3NM from shore upon the Great Lakes must carry a Category 1 EPIRB; EPIRB battery inoperable and must be replaced. Route limited to the boundary line of 20NM from a harbor or safe refuge.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2021
Resolved 26 May 2021
Resolution: EPIRB replaced.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 April 2021 Resolved
Vessel must be provided with a satisfactory arrangement for draining any watertight compartment; no suction for dewatering space.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2021
Resolved 26 May 2021
Resolution: verified suction is operational
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 20 April 2021 Resolved
Each vessel must have marine charts which are currently corrected; charts are out of date and have not been manually corrected.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2021
Resolved 26 May 2021
Resolution: Provided new charts for operational area
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 April 2020 Resolved
46 CFR 182.20-20 Exhaust shall be gastight throughout its length and shall be properly supported by non-combustible hangers or blocks. Exhaust piping on the port MDE has a leak. Repair to the satisfaction of CG Marine Inspector within 7 days.
Action required: 705 - Other - as specified
Resolved 8 April 2020
Resolution: Exhaust pipe was re-welded.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 3 April 2020 Resolved
46 CFR 182.20-15 & 20 Exhaust piping shall be suitably insulated. Section on the stbd MDE exhaust piping is missing lagging. Repair to the satisfaction of CG Marine Inspector within 14 days.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 April 2020
Resolution: Lagging on exhaust pipe was re-installed.
09 - Working and Living Conditions › 092 - Working Conditions › Holds and tanks safety
Issued 3 April 2020 Resolved
46 CFR 176.700 Alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant [name withheld] and receive Marine Safety Center approval for the stability effects of changing the rig water tanks to diesel tanks.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 April 2020
Resolution: MSC sent approved plan review lightship change letter and reduced cargo loading diagram.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 3 April 2020 Resolved
Repairs or alterations to the hull, machinery or equipement that affect the safety of the vessel must not be made without the approval of the OCMI, except during an emergency. Vessel reported that they puntured the hull 2" below the waterline while mooring due to a bolt sticking out from the pierface. Vessel reports that a satisfactory temporary repair has been made stopping the ingress of water. Make permanenant repairs to the satisfaction of CG Marine Inspector. 46 CFR 176.700
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 May 2020
Resolved 8 April 2020
Resolution: Vessel cropped and inserted an 18x18. Fitup, backgouge, and final weld test all sat.
Stability › Watertight Integrity › General
Issued 7 April 2017 Resolved
Electrical wire cable running through the forward engine room bulkhead needs to be watertight.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 14 April 2017
Resolved 24 April 2017
Resolution: Corrected.
Fire Fighting › Ventilation Systems › Fans
Issued 7 April 2017 Resolved
Power exhaust ventilation needs to be cleared of grime and debris to prevent motors from overheating.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 April 2017
Resolved 24 April 2017
Resolution: Corrected.
Engineering › Fuel Oil Service System › Discharge Strainer
Issued 7 April 2017 Resolved
Plastic flame screen drain plugs need to be replaced with metallic plugs.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 April 2017
Resolved 24 April 2017
Resolution: Corrected.
Lifesaving › Lifebuoys › Approval
Issued 7 April 2017 Resolved
Ring lifebuoy on the aft deck does not have approval sticker/information and needs to be removed or replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 April 2017
Resolved 24 April 2017
Resolution: Corrected.
Engineering › Fuel Oil Service System › Valve
Issued 9 September 2010 Resolved
Stencil emergency fuel shut off.
Action required: 705 - Other - as specified
Due 24 October 2010
Resolved 29 October 2010
Resolution: completed.
Lifesaving › Lifefloat › Float-free Link
Issued 9 September 2010 Resolved
Secure link to vsl.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 24 September 2010
Resolved 24 September 2010
Resolution: completed
Lifesaving › Lifefloat › Paddle
Issued 9 September 2010 Resolved
secure and label paddles
Action required: 17 - Rectify deficiencies prior to departure
Due 24 September 2010
Resolved 24 September 2010
Resolution: completed
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 9 September 2010 Resolved
label all lifebuoys.
Action required: 17 - Rectify deficiencies prior to departure
Due 24 September 2010
Resolved 24 September 2010
Resolution: completed
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 9 September 2010 Resolved
secure lights to lifefloat.
Action required: 17 - Rectify deficiencies prior to departure
Due 24 September 2010
Resolved 24 September 2010
Resolution: completed
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 9 September 2010 Resolved
provide anchor onboard.
Action required: 17 - Rectify deficiencies prior to departure
Due 24 September 2010
Resolved 24 September 2010
Resolution: completed
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 12 November 2008 Resolved
Provide 2008 edition of tidal currents
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 November 2008
Resolution: Recieved receipt of purchase of new book
Lifesaving › Embarkation Appliances/Stations › Designated Location
Issued 12 November 2008 Resolved
Repiar emergency embarkation lighting
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 November 2008
Resolution: Lighting installed and operating
Documentation › Certificates/Documents › Certificate of Inspection
Issued 12 November 2008 Resolved
Vessel failed to conduct Re-Inspection within 3 months of date of COI issue.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 April 2017
Resolution: Re-inspection conducted
Documentation › Certificates/Documents › Certificate of Inspection
Issued 12 November 2008 Resolved
Vessel failed to conduct Dry Dock in accordance with the COI with in the required timeline
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 April 2017
Resolution: Dry Dock conducted
Construction/Loadline › Hull › Stiffener
Issued 14 November 2007 Resolved
Overhead angles in rudder room tripped at transition to the transom. Vessel to remove and insert new angles.
Action required: 705 - Other - as specified
Due 15 November 2007
Resolved 16 November 2007
Resolution: New angles installed - sat repair
Documentation › Certificates/Documents › Certificate of Inspection
Issued 14 November 2007 Resolved
Owner of vessel failed to make vessel available for annual inspection within 3 months before or after aniversary date of issuance of COI.
Due 15 November 2007
Resolved 15 November 2007
Resolution: Issued NOV 00127137
Navigation
Issued 10 November 1992 Resolved
SINGLE SIDE BAND DID NOT HAVE AN INDEPENDENT POWER RESERVE SUPPLY TO OPERATE BEYOND 100 NM FROM SHORE.
Condition: Unknown
Due 10 November 1992
Resolved 10 November 1992

Ownership record