MAURY USCG vessel records Sign in
← All vessels

CAPT. ORE

CAPT. ORE is a 1990 tank ship. The Coast Guard has recorded 79 inspections since 1990, most recently in February 2012, along with 30 deficiencies — 1 with no resolution recorded — and 9 operational controls, 1 with no removal date recorded.

Records from 1990 to 2012. Most recent: inspection, 27 February 2012.

Built
1990
Last inspected
27 February 2012
Documentation
Not in the documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

8613994 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
356939
Flag
CYPRUS
—
Maury page id
psix-356939

Inspections, by type

…with no type recorded50
Years with a record 18 calendar years (1990–2012)
The 79 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it30170 - Convention (Subpart B), Gross Ton
11195 - Convention (Subpart B), Net Ton
12184 - Displacement, Ton
44216 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

B. NO. 65 Tank Barge · MISLE 45818 · 19 January 1999 · activity 465613GREAT LAKES Tank Barge · MISLE 54515 · 28 November 1998 · activity 537690

Inspection history · 79

27 February 2012 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4244850
10 December 2010 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3908030
4 June 2007 MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2950870
4 June 2007 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2951734
4 June 2007 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2951777
4 June 2007 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2952991
5 May 2007 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2922708
2 May 2007 MARPOL Annex I Examination · Ballast Water Examination · MARPOL Annex V Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2920523
30 April 2007 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2919606
12 March 2007 Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2886143
4 February 2007 COC-TVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2863964
7 January 2007 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2851596
19 October 2006 Type not recorded
No type recorded · Station Mayport · USCG Southeast District (CGD-SE) · Activity 2804254
17 October 2006 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2802625
27 April 2006 Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2634854
9 April 2006 Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2620985
5 April 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2617699
21 February 2006 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2589073
30 January 2006 COC-TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2576303
13 May 2005 Ballast Water Examination · ISPS III Exam · Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2353157
5 April 2005 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2326702
28 December 2004 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2265681
24 December 2004 COC-TVE Annual
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2262934
13 September 2004 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2194832
6 August 2004 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2162071
23 July 2004 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2167855
16 July 2004 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2135347
5 July 2004 ISPS II Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2118643
13 May 2004 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2066706
1 April 2004 Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2036258
1 March 2004 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2016186
7 January 2004 Security Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1984491
4 December 2003 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1961878
14 October 2003 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1927772
1 October 2003 Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1918704
21 March 2002 Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1495711
14 December 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 435729
14 December 1999 Letter of Compliance (Initial/Renewal)
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 813398
26 July 1999 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 677112
23 March 1999 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 474942
19 January 1999 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 465613
14 December 1998 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 423499
14 December 1998 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 808477
28 November 1998 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 537690
13 December 1997 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 410907
13 December 1997 MARPOL Annex I Examination · Letter of Compliance (Initial/Renewal)
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1114456
7 January 1997 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 399035
7 January 1997 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1097018
24 June 1996 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 392437
1 December 1995 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 385970
1 December 1995 Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 883476
1 December 1995 Letter of Compliance (Initial/Renewal)
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 883603
5 July 1995 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 454044
28 February 1995 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 677113
20 February 1995 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 30835
23 November 1994 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 372823
23 November 1994 Tank Vessel Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1176125
12 August 1994 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1176401
11 August 1994 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1411012
31 July 1994 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 445727
2 July 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 368296
9 June 1994 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 529760
15 November 1993 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 463044
15 November 1993 Certificate of Compliance
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 827432
10 June 1993 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 460232
22 April 1993 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 357922
30 March 1993 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 357244
16 February 1993 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 833928
28 October 1992 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 354165
28 October 1992 Certificate of Compliance
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1244873
8 September 1992 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 935377
19 August 1992 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1251677
4 August 1992 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 948703
27 April 1992 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 350566
1 April 1992 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 452587
1 November 1991 Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1252816
17 June 1991 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 500707
3 November 1990 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 340057
3 November 1990 Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 936296

Deficiency record · 30

Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 10 December 2010 Resolved
Stairways that penetrate more than a single deck shall be surrounded by at least A-0 class divisions and be protected by self closing doors at all levels. All of the vessels self closing doors in the main stairwell fail to close on their own accord. This poses a hazard in the event of a fire. Correct to the satisfaction of class. SOLAS 97 CONS. II-2/46.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 December 2010
Resolution: Rectified to the satisfaction of the Classification Society''s surveyor.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 10 December 2010 Resolved
Vessel doors required to be self closing shall not be fitted with hold back hooks. Vessels self closing doors to bridge and radio room are fitted with hold back devices. This poses a hazard in the event of a fire. Correct to the satisfaction of class. SOLAS 97 CONS. II-2/47.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 December 2010
Resolution: Rectified to the satisfaction of the Classification Society''s surveyor.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 10 December 2010 Resolved
Vessel doors fitted in boundary bulkheads of machinery spaces of class A shall be self closing. Vessels category A door fitted for entry into the ECR fails to self close. This poses a hazard in the event of a fire. Correct to the satisfaction of class. SOLAS 97 CONS. II-2/47.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 December 2010
Resolution: Rectified to the satisfaction of the Classification Society''s surveyor.
Fire Fighting › Portable Foam Applicators › General
Issued 10 December 2010 Resolved
Fire extinguishing appliances shall be kept in good order and be readily available for use at all times. Vessels foam fire fighting applicator is dry rotted, rendering the applicator not readily available. This poses a hazard in the event of a fire. Correct to the satisfaction of class. SOLAS 97 CONS. II-2/21
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 December 2010
Resolution: Rectified to the satisfaction of the Classification Society''s surveyor.
Engineering › Fuel Oil Service System › Pump
Issued 10 December 2010 Resolved
Vessels machinery shall be so installed as to reduce to a minimum any danger to persons on board. #1 and #2 FO booster pumps for the SSDG's are leaking at the gland packing and had rags placed on either sides of the pump. The vessel also has collection pans filled with oil. This creates a fire hazard for the crew and vessel. Correct to the satisfaction of class. SOLAS 97CONS. II-1/26.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 December 2010
Resolution: Rectified to the satisfaction of the Classification Society''s surveyor.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 10 December 2010 Resolved
The vessel is required to have instructions and procedures to ensure the safe operation of the ship. The fire doors and portable applicators are required to be checked weekly. The condition of these items shows that the vessel is not following SMS procedures for weekly fire safety checks. An external ISM Audit is requested. Correct the satisfaction of the Administration. SOLAS 09 CONS. IX/3.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 27 February 2012
Resolution: Conducted satisfactory ISM external audit.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 10 December 2010 Resolved
Satisfactory means shall be provided for the protection of the crew in getting to and from their quarters, and the machinery space. In the E/R next to the cascade tank, there is a platform approx 5ft in the air and the crew has removed 2 side railings. There is no protection for crew members on this platform. Correct to the satisfaction of class. ICLL ANNEX I/25.4
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 December 2010
Resolution: Rectified to the satisfaction of the Classification Society''s surveyor.
Construction/Loadline › Markings › Load Line Mark
Issued 10 December 2010 Resolved
Load line mark and deckline shall be painted in white or yellow on a dark background or in black on a light background. Vessels load line mark and deck line are not plainly visible. Correct to the satisfaction of class. ICLL ANNEX I/8
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 December 2010
Resolution: Rectified to the satisfaction of the Classification Society''s surveyor.
Documentation › Certificates/Documents › IOPP Certificate
Issued 10 December 2010 Resolved
The IOPPC shall be drawn up in the form corresponding to model given in appendix II of Annex I of MARPOL. Vessels IOPP Form A incorrectly states vessels OCM is in accordance with Resolution A393(X). However, the vessel is fitted with an OCM in accordance with MEPC 107(49). Correct to the satisfaction of class. MARPOL ANNEX I/9
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 December 2010
Resolution: Rectified to the satisfaction of the Classification Society''s surveyor.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 4 June 2007 Resolved
While inspecting the engine room, suspicious piping was found. Based upon the objective evidence found ; such as a 2" by 122" steel pipe w/ a 45 degree welded elbow on the end with multiple flex hoses that have the capability of being clamped on opposite ends of the steel pipe to bypass the OWS. Vessels Flag State must attend vessel and provide written attestation that the OWS operates properly
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 June 2007
Resolution: The vessel''''s class, Bureau Veritas came aboard vessel 05 and 06 JUN 07 and conducted tests of Bilge water separator and Oil content meter, including automatic stoppage of pump and activation of 3-way valve. All tests SAT.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 2 May 2007 Resolved
OILY WATER SEPERATOR THREE WAY VALVE NOT OPERATING PROPERLY. ALL OIL RESIDUE, BILGE WATER AND SLUDGE TO BE RETAINED ON BOARD VESSEL OR DISCHARGED TO SHORE FACILITY.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 10 May 2007
Resolution: Received Class report attesting to OWS repairs.
Fire Fighting › Fire Main › Condition
Issued 4 February 2007 Resolved
Three noticeable pinhole leaks within an inch of each other in port fantail firemain. Leaks do not significantly affect ships ability to fight fires. SOLAS 60 II-2/56
Action required: 705 - Other - as specified
Resolved 12 March 2007
Resolution: Received class report from Bureau Veritas satisfying requirement. The BV report stated: Pinhole leaks found on PS Fantail Firemain, repaired & found satisfactory.
Documentation › Logs/Records › Cargo Record Book (NLS)
Issued 4 February 2007 Resolved
Cargo record book not updated in accordance with MARPOL ANNEX II 2004 revision.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 12 March 2007
Resolution: Received Class report stating that the requirements of Marpol Annex II as amended through Res. MEPC 118(52), are not covered by the present Classification Certificate
Documentation › Manuals/Policy Documentation › Procedures and Arrangements Manual (NLS)
Issued 4 February 2007 Resolved
Procedures and Arrangements Manual not updated, nor was there a letter from their flag administration or class society acknowledging receipt of its submittal to meet the requirements of the MARPOL ANNEX II 2004 revisions. MARPOL 73/78 (1997 Consolidated Edition) Annex II Ch. 2
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 12 March 2007
Resolution: Received Class report stating that the requirements of Marpol Annex II as amended through Res. MEPC 118(52), are not covered by the present Classification Certificate
Construction/Loadline › Markings › Load Line Mark
Issued 4 February 2007 Resolved
Deckline not marked in accordance with ICLL Certificate. Deckline is not marked or permanantly affixed on either side of the hull.
Action required: 705 - Other - as specified
Resolved 12 March 2007
Resolution: Received class report from Bureau Veritas satisfying requirement. The BV report stated: Deck line marks Port & Starboard sides, painted accordingly ILLC and found satisfactory.
Deck/Cargo › Vapor Control Systems › Liquid Knockout Vessel
Issued 30 January 2006 Resolved
Vessel is authorized to carry Chapter 17 cargo - Sodium Hydroxide Solution (Caustic Soda). Vessels does not have audible alarm for High level.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 21 February 2006
Resolution: Tested satisfactory.
Documentation › Certificates/Documents › IOPP Certificate
Issued 30 January 2006 Resolved
IOPP indicates vessel is an Oil Tanker. Vessel is authorized to carry Chapter 17 cargo - Sodium Hydroxide Solution (Caustic Soda). This makes the vessel a Chemical Tanker carrying Oil.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 21 February 2006
Resolution: Certificate of Fitness removed and IOPP was amended so vessel is classified as an oil tanker.
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 30 January 2006 Resolved
Chief Engineer and Electrician were not able to demonstrate procedures for calibrating IGS or how the system works, i.e. Electrician was stating the local meter was not connected to the remote meter. Ship superintendent had to show them how to calibrate. Required company to conduct internal audit. Audit should reveal how the system works and that the responsible individuals understand operation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 February 2006
Resolution: Company investigated the cause of the deficiency and conducted extensive training
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 30 January 2006 Resolved
Vessel is authorized to carry Chapter 17 cargo - Sodium Hydroxide Solution (Caustic Soda). Some officers do not have a Chemical Tanker endorsement. Vessel is not to carry Sodium Hydroxide Solution (Caustic Soda) until it meets all requirements for a Chemical Tanker.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 21 February 2006
Resolution: Certificate of Fitness removed and IOPP amended. Vessel now classified as an oil tanker. Chemical tanker endorsements no longer required.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 5 April 2005 No resolution recorded
While en route to the Port of New York the vessel suffered a loss of the starboard anchor. The vessel must submit a survey from Det Norske Veritas certifying the vessel is fit for its intended route and service.
Action required: 17 - Rectify deficiencies prior to departure
Resolution: A satisfactory class report was received via fax attesting to the repairs of the starboard anchor
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 24 December 2004 Resolved
Vessel's SOPEP not reviewed and updated to reflect new class society. Prior to next US port provide evidence of flag state approval of current SOPEP.
Action required: 15 - Rectify deficiencies by next port
Resolved 28 December 2004
Resolution: FLAG STATE APPROVAL CONFIRMED
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 24 December 2004 Resolved
Renew markings on bow and stern (name and IMO number).
Due 24 February 2005
Resolved 13 May 2005
Resolution: VIEWED AND CLEARED BY USCG MARINE INSPECTOR AND BOARDING OFFICER.
Fire Fighting › Structural Fire Protection - General › Cooking Area
Issued 24 December 2004 Resolved
Repair/replace starboard galley door between pantry and galley. Door will not close.
Due 24 January 2005
Resolved 13 May 2005
Resolution: VIEWED AND CLEARED BY USCG MARINE INSPECTOR AND BOARDING OFFICER.
Navigation › Collision/Grounding Avoidance
Issued 1 October 2003 Resolved
RADAR WAS INOPERABLE; FOUND TEETH ON THE TEFLON GEAR TO BE WORN OUT LEGACY COMPONENT DESC: Radar
Condition: Unknown
Due 1 October 2003
Resolved 1 October 2003
Resolution: TECHNITIAN BROUGHT ONBOARD TO FIX PROBLEM, REPAIRED SATISFACTORALLY
Deck/Cargo
Issued 1 December 1995 Resolved
Oil discharge monitor not calibrated properly.
Condition: Unknown
Due 15 December 1995
Resolved 15 December 1995
Deck/Cargo
Issued 23 November 1994 Resolved
NOTED THAT OXYGEN LEVEL IN TANKS WERE AT 9%.
Condition: Unknown
Due 28 November 1994
Resolved 28 November 1994
Electrical
Issued 11 August 1994 Resolved
Prior to departurer from San Francisco Bay, CA., Have vessel's classification society investigate and submit recommendations for repairs to the 3 damaged explosive proof light fixtures in Cargo Pump room.
Condition: Unknown
Due 12 August 1994
Resolved 12 August 1994
Deck/Cargo
Issued 28 October 1992 Resolved
REPROGRAM CARGO GUAGING ALARM SYSTEM SO ONLY THE OVERFILL ALARM AND LIGHT SOUNDS OUTSIDE AND NOT THE HIGH LEVEL ALARM, OR HIGH LEVEL ALARM IS A DIFFERENT SOUND. TO BE CLEARED PRIOR TO LOADING AT NEXT U.S. PORT, WHILE USING VRS.
Condition: Unknown
Due 28 October 1992
Resolved 28 October 1992
Deck/Cargo
Issued 28 October 1992 Resolved
TEST CARGO PUMP EMERGENCY STOPS PRIOR TO DISCHARGE OF CARGO AT NEXT U.S. PORT, WITNESSED BY USCG MARINE INSPECTOR.
Condition: Unknown
Due 28 October 1992
Resolved 28 October 1992
Documentation
Issued 4 August 1992 Resolved
PROVIDE DOI IN ACCORDANCE WITH 46 CFR 35.35-30 WHICH IS SPECIFIC TO THIS VESSEL.
Condition: Unknown
Due 4 August 1992
Resolved 4 August 1992

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.