← All vessels
NINGBO PIONEER
NINGBO PIONEER is a 1990 freight ship. The Coast Guard has recorded 25 inspections since 1990, most recently in December 2010, along with 10 deficiencies and 4 operational controls.
Records from 1990 to 2010. Most recent: inspection, 18 December 2010.
- Built
- 1990
- Last inspected
- 18 December 2010
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 10 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
8801022 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
VRCD5
356959
Flag
LIBERIA
—
Maury page id
psix-356959
Inspections, by type
…with no type recorded15
Years with a record
16 calendar years (1990–2010)
The 25 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it37519 - Convention (Subpart B), Gross Ton
22604 - Convention (Subpart B), Net Ton
68788 - Dead Weight, Ton
79032 - Displacement, Ton
22604 - Convention (Subpart B), Net Ton
68788 - Dead Weight, Ton
79032 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 25
18 December 2010
Ballast Water Examination · PII Safety Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3914452
9 December 2010
ISPS I Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3900489
9 December 2010
COE-Offshore
Physical examination · Station Port Aransas · USCG Heartland District (CGD-H) · Activity 3908006
13 March 2010
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3691279
28 January 2010
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3671738
28 January 2008
Ballast Water Examination · MARPOL Annex I Examination · PII Safety Exam · MARPOL Annex V Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3133215
27 June 2006
MARPOL Annex I Examination · PII Safety Exam · Ballast Water Examination · ISPS II Exam · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2692200
8 August 2005
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2456363
28 October 2004
Ballast Water Examination · NPV Safety Exam · ISPS II Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2229672
24 October 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2227289
20 April 2004
Annual Inspection · Ballast Water Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2048095
26 November 2003
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1958573
4 March 2002
Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1490892
7 March 2000
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 275235
7 December 1998
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 423028
18 March 1997
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 401511
27 January 1996
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 387304
30 December 1994
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 373698
30 December 1994
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1162221
12 August 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 173237
3 August 1994
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 479838
5 December 1993
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 362956
19 May 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 450022
21 November 1991
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 347218
10 November 1990
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 340215
Deficiency record · 10
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 28 January 2010
Resolved
2030.
Vessel is missing third deck officer Vessel has been granted dispensation by Hong Kong flag state, allowing the vessel to sail, but must meet minimum safe manning requirements within 28 days of issue (NLT 25 Feb10).50c
Fire Fighting
Issued 7 December 1998
Resolved
Perform maintenence and grease engine room vent closures port side to attain proper closure IAW SOLAS 74 II-2/16.9 to satisfaction of attending CG Marine Inspector prior to 07JAN99.
Fire Fighting
Issued 7 December 1998
Resolved
Repair or replace engine room vent expansion joints IAW SOLAS 74 II-2/16.9_x001C_to the satisfaction of class surveyor prior to 07JAN99.
Lifesaving
Issued 7 December 1998
Resolved
Remove combustible materials from electric cable trunks prior to 07DEC98.
Lifesaving
Issued 7 December 1998
Resolved
Renew port lifeboat operators brake wire IAW SOLAS 74 III/48.1.4 prior to 07JAN99.
Lifesaving
Issued 7 December 1998
Resolved
Provide launching instructions for starboard side lifeboat IAW SOLAS 74 III/9 prior to 07JAN99.
Navigation
Issued 27 January 1996
Resolved
TIDE AND TIDE CURRENT TABLES NOT CURRENT, NO FORIEGN EQUIVILANT ONBOARD._x001C_
Navigation
Issued 27 January 1996
Resolved
ARPA HAVING AN INTERMITTENT ERROR CODE WHILE ATTEMPTING TO AQUIRE TARGETS. TECH REP TO REPAIR PRIOR TO DEPARTURE BALMS._x001C_ _x001C_ _x001C_
Lifesaving
Issued 30 December 1994
Resolved
SOLAS III/38.6: LIFE RAFT SEA PAINTER WEAK LINKS NOT PROPERLY RIGGED FOR FLOAT FREE LAUNCHING.
Documentation
Issued 10 November 1990
Resolved
OIL TRANSFER PROCEDURES WERE NOT FILLED OUT PROPERLY AS REQUIRED BY 33 CFR_x001C_155.750
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.