Records from 2016 to 2026. Most recent: inspection, 27 April 2026.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Documentation record
Registered dimensions (L × B × D)52.0 ft × 17.5 ft × 8.9 ft
Registered tonnagegross 54 / net 43
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGILLMAN MARINE INC · PANAMA CITY, FL, UNITED STATES · built 1992
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portDESTIN, FL
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 18 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it54 - Simplified, Gross Ton
43 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page
23 inspections, each with its date, unit and type; 10 deficiencies with the resolution recorded against each; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
Plans
Sign in
Maury does not score, rate or grade vessels, at any price.
Inspection history · 23
27 April 2026
Vessel Attendance · DAPI Audit · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8340550
17 September 2025
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8236236
21 July 2025
Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 8191600
20 February 2025
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8082229
28 August 2024
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7991317
23 August 2023
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7774461
2 March 2023
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7644442
19 September 2022
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7562649
27 July 2022
In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7517576
3 May 2022
Type not recorded
No type recorded · USCGC DOLPHIN (WPB 87354) · USCG Heartland District (CGD-H) · Activity 7447501
3 December 2021
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7361864
19 July 2021
COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7257851
18 February 2021
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7142242
24 September 2020
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7064082
26 September 2019
In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6823023
5 September 2019
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6804855
24 July 2019
Type not recorded
No type recorded · USCGC ALBACORE (WPB 87309) · USCG Northeast District (CGD-NE) · Activity 6776929
5 February 2019
Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6621492
23 October 2018
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6571524
24 August 2018
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6521495
24 August 2017
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6243921
2 March 2017
Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6093549
14 July 2016
Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5941014
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 23 August 2023
Resolved
The vessel operating beyond the boundary line must be equipped with an EPIRB. The vessels EPIRB battery is expired.
Action required: 705 - Other - as specified
Resolved 24 August 2023
Resolution: Corrected.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 23 August 2023
Resolved
All radios must be DSC capable and installed accordingly. The radios do not have the MMSI programmed and GPS linked.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 September 2023
Resolved 24 August 2023
Resolution: Corrected.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 23 August 2023
Resolved
Machinery space ventilation must be capable of being shut in the event of a fire. The four (4) manually shut ventilation louvers do not completely close when actuated.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 September 2023
Resolved 24 August 2023
Resolution: Corrected.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 19 July 2021
Resolved
Emergency escape scutttle must open from either side. Replace scuttle to be opened from either side.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 August 2021
Resolved 19 September 2022
Resolution: Owner replaced emergency escape scuttle, tested operation from both sides, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 September 2019
Resolved
Vessel waterlight is required to be attached to ring buoy via 3 ft line with corrosion resistant quick release clip. Vessel waterlight was attached to ring buoy 60 ft line. Vessel to properly attach waterlight to ring buoy.
46 CFR 180.70 (d)(2)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 October 2019
Resolved 26 September 2019
Resolution: Crew properly attached the waterlight to the ring buoy with a 3 ft line with a corrosion resistant quick release clip.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 26 September 2019
Resolved
Vessel waterlight attached to life float must be attached with a 3/8 inch 18 ft lanyard that is resistant to ultraviolet deterioration.
46 CFR 180.175 (f)(4)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 October 2019
Resolved 26 September 2019
Resolution: Crew replaced line for waterlight and properly attached it to the life float.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 September 2019
Resolved
Vessel is required to carry 3 BII fire extinguishers. Found 1 unserviceable. Vessel to replace with charger extinguisher.
46 CFR 181.500
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 October 2019
Resolved 26 September 2019
Resolution: Vessel provided new extinguisher.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 19 July 2016
Resolved
Provide valid COD
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 August 2016
Resolved 25 July 2016
Resolution: Vessel provided COD
Electrical › Lighting (emergency) › Lighting Fixture
Issued 19 July 2016
Resolved
Provide emergency lighting
Action required: 705 - Other - as specified
Due 2 August 2016
Resolved 3 August 2016
Resolution: Vessel provided emergency lighting
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 19 July 2016
Resolved
Provide DOT approved alcohol test equipment
Action required: 705 - Other - as specified
Due 2 August 2016
Resolved 3 August 2016
Resolution: Vessel provided test equipment