MAURY USCG vessel records Sign in
← All vessels

SEA VENUS

SEA VENUS is a 1990 freight ship. The Coast Guard has recorded 32 inspections since 1990, most recently in September 2010, along with 15 deficiencies and 5 operational controls.

Records from 1990 to 2010. Most recent: operational control imposed, 20 September 2010.

Built
1990
Last inspected
20 September 2010
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8916152 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
357027
Flag
SOUTH KOREA
—
Maury page id
psix-357027

Inspections, by type

…with no type recorded20
Years with a record 19 calendar years (1990–2010)
The 32 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it36741 - Convention (Subpart B), Gross Ton
22917 - Convention (Subpart B), Net Ton
78786 - Displacement, Ton
68849 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 32

20 September 2010 Ballast Water Examination · NPV Safety Exam · ISPS I Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3848757
18 September 2010 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3849206
7 December 2009 MARPOL Annex I Examination · ISPS I Exam · PII Safety Exam · Ballast Water Examination · MARPOL Annex VI Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3640057
3 December 2009 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3640058
23 September 2008 Ballast Water Examination · MARPOL Annex I Examination · ISPS III Exam · MARPOL Annex V Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3319450
25 February 2008 Deficiency Check · ISPS II Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3152880
24 April 2007 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2914560
5 April 2007 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2902439
21 July 2006 Ballast Water Examination · PII Safety Exam · Deficiency Check · ISPS II Exam
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2720047
15 June 2005 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2391356
30 July 2004 ISPS II Exam
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2150252
30 July 2004 PII Safety Exam
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2150383
2 May 2003 Annual Inspection · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1785379
7 February 2002 Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1484976
24 February 2001 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 287038
2 May 2000 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 277356
14 January 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 274019
13 January 2000 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 708814
28 December 1999 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 435960
28 December 1999 Port Security Assessment
Type not classified · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 594556
30 November 1999 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 435069
26 November 1999 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 110534
22 April 1999 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 427598
14 January 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 412059
15 November 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 396950
12 January 1995 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 373898
3 May 1994 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 366544
14 January 1994 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 481176
6 January 1994 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 363494
12 May 1993 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 358117
27 October 1992 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 353735
13 November 1990 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 340350

Deficiency record · 15

Engineering › Steering Gear System › Valve, Control
Issued 20 September 2010 Resolved
0750 - Fire Prevention - The directional control valve on the #2 steering system is leaking hydraulic fluid 4 to 5 drips per second posing a fire hazard. - SOLAS 74am II-2/4
Action required: 705 - Other - as specified
Due 27 September 2010
Resolved 24 September 2010
Resolution: Received, reviewed and accepted class report KRS stating the deficiency was rectified. All parts of the directional control valve were dismantled and all o-rings replaced.
Engineering › Diesel Engine (auxiliary) › Pump, High Pressure (fuel injection)
Issued 20 September 2010 Resolved
0750 - Fire Prevention - The primary fuel pump on the #1 ship's service generator is leaking 4 to 5 drips per second posing a severe fire hazard. - SOLAS 74am II-2/4.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 September 2010
Resolution: Received, reviewed and accepted class report KRS stating the deficiency was rectified. The shaft oil seal of the Number 1 generator fuel pump was renewed.
Fire Fighting › Emergency Fire Pumps › Arrangement
Issued 23 September 2008 Resolved
PSCO found temporary soft patch in pipe on the discharge side of the emergency fire pump just above pump outlet.
Action required: 705 - Other - as specified
Due 30 September 2008
Resolved 29 September 2008
Resolution: Received class report from Korean Register of Shipping rectifying the deficiency.
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 23 September 2008 Resolved
Vessel is to conduct a hydrostatic pressure to the bunkering lines IAW 33 CFR 156.170. Vessel is prohibited from bunkering in US waters until test is completed.
Action required: 705 - Other - as specified
Due 23 September 2008
Resolved 24 September 2008
Resolution: Received e-mail verification from the Master with photos showing that the hydrostatic test was satisfactorily conducted.
Fire Fighting › Firemans Outfit
Issued 2 May 2003 Resolved
Fireman's outfit worn and has several rips along the seams. LEGACY COMPONENT DESC: Protective Clothing
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 May 2003
Resolved 2 May 2003
Resolution: Recieved report from World Ship Supply stating that 01 new fireman''''s outfit delivered to vessel.
Engineering › Diesel Engine (auxiliary) › Waste Heat Recovery
Issued 2 May 2003 Resolved
The No. 3 generator has a weld patch on the water inlet and outlet piping to the lube oil cooler. 04MAY03 - Received Class Report stating inlet piping was renewed and outlet piping was temporarily repaired by welding doubler. A Condition of Class was imposed due on 26AUG03. LEGACY COMPONENT DESC: Water inlet/outlet piping
Action required: 705 - Other - as specified
Due 26 August 2003
Resolved 30 July 2004
Resolution: NKK via documents cleared deficiency and was verified by attending CG inspector
Engineering › Diesel Engine (auxiliary) › Waste Heat Recovery
Issued 2 May 2003 Resolved
The NO. 1 generator has a temporary hose clamp patch on the water inlet piping to the lube oil cooler. 04MAY03 - Received Class Report stating inlet piping was repaired temporarily by welding. A Condition of Class was imposed due not later than 26AUG03. LEGACY COMPONENT DESC: Water inlet/oulet piping
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 August 2003
Resolved 30 July 2004
Resolution: NKK via documents cleared deficiency and was verified by attending CG inspector.
Engineering › Diesel Engine (auxiliary) › Waste Heat Recovery
Issued 2 May 2003 Resolved
The auxiliary jacket water cooler has a leaking weld patch on the water outlet piping. 04MAY03 - Received Class Report stating outlet piping was temporarily repaired by welding with plastic cement over the repair. A Condition of Class was imposed due not later than 26AUG03.
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 August 2003
Resolved 30 July 2004
Resolution: NKK via documents cleared deficiency and was verified by attending CG inspector.
Engineering › Diesel Engine (propulsion-direct drive) › Waste Heat Recovery
Issued 2 May 2003 Resolved
The main engine jacket water cooler has a leaking weld patch on the water outlet piping. 04MAY03 - Received Class Report stating outlet piping was temporarily repaired by welding doubler. A Condition of Class was imposed due not later than 26AUG03.
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 August 2003
Resolved 30 July 2004
Resolution: NKK via documents cleared deficiency and was verified by attending CG inspector.
Fire Fighting › Combustible Materials
Issued 2 May 2003 Resolved
The house keeping of the engine room needs attention. Oil has overflowed from the rocker arm lubricating oil tank of all three generators. The oil has been thrown by the flywheel over the rear of the generators. LEGACY COMPONENT DESC: House Keeping
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 May 2003
Resolved 4 May 2003
Resolution: The crew began cleaning the engine room before the boarding team departed. Class stated the engine room was "reasonably clean" but recommended that the crew continue cleaning.
Engineering
Issued 28 December 1999 Resolved
HAVE CLASS SOCIETY ATTEST TO PERMANENT REPAIRS OF THE 2 INCH OUTLET PIPING WHICH WAS TEMPERARILY REPAIRED FOR 15 PPM SYSTEM AT OUTLET OF SPARATOR. _x001C_ _x001C_ REFERENCE ABS CLASS REPORT FROM 06JAN00
Condition: Unknown
Due 2 May 2000
Resolved 2 May 2000
Documentation
Issued 28 December 1999 Resolved
HAVE CLASS SOCIETY ATTEST TO PROPER OPERATION OF OILY WATER SEPARATOR 15 PPM ALARM AND AUTOMATIC STOPPING DEVICE._x001C_ MARPOL 73/78;15
Condition: Unknown
Due 6 January 2000
Resolved 29 December 1999
Engineering
Issued 30 November 1999 Resolved
HAVE CLASS SOCIETY ATTEST TO PROPER OPERATION OF OILY WATER SEPERATOR 15 PPM ALARM AND AUTOMATIC STOPPING DEVICE. MARPOL 73/78;15.
Condition: Unknown
Due 25 January 2000
Resolved 25 January 2000
Lifesaving
Issued 30 November 1999 Resolved
REPLACE/ RENEW/ REPAIR STARBOARD LIFEBOAT DAMAGED DURING LOWERING ON 26NOV99. SOLAS 76 AMMENDED CH.I REG.II
Condition: Unknown
Due 2 May 2000
Resolved 2 May 2000
Engineering
Issued 6 January 1994 Resolved
TRANSFER PROCEDURES WHERE INCOMPLETE. MISSING THE FOLLOWING ITEMS AS CFR 33 155.750(a)(1,3,4,5,7).
Condition: Unknown
Due 4 May 1994
Resolved 4 May 1994

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.