PELICAN I

PELICAN I is a 1990 passenger vessel (inspected). The Coast Guard has recorded 43 inspections since 1991, most recently in January 2012, along with 54 deficiencies.

Records from 1991 to 2012. Most recent: inspection, 9 January 2012.

Built
1990
Last inspected
9 January 2012
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDC4081
357185
Flag
UNITED STATES
367018770 (licence lapsed)
Maury page id
psix-357185

Inspections, by type

…with no type recorded3
Years with a record 21 calendar years (1991–2012)
The 43 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it12 - Simplified, Gross Ton
10 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDC4081MMSI 367018770 · expired · compulsorily equipped · granted 17 February 2005, cancelled 25 April 2015
WCZ8165MMSI not assigned · expired · compulsorily equipped · granted 11 May 2000, cancelled 17 July 2010
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 43

9 January 2012 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4221243
14 February 2011 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3944730
25 February 2010 Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3684634
16 March 2009 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3434696
4 February 2009 Internal Structural Exam · Annual Inspection · Hull Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3412159
6 December 2007 Deficiency Check · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3110454
15 February 2007 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2874634
29 January 2007 Hull Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2862144
26 January 2006 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2573581
16 February 2005 Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2293787
2 February 2005 Hull Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2285139
4 February 2004 Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2000173
18 February 2003 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1746158
18 December 2002 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1720382
11 January 2002 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1477874
19 March 2001 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1366239
15 March 2001 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1060326
6 February 2001 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1397568
25 January 2000 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 814876
20 December 1999 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1416999
27 January 1999 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1365020
18 December 1998 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1408218
30 April 1998 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1124701
23 December 1997 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 784161
21 April 1997 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 694830
11 March 1997 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1106816
9 February 1997 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 212230
9 February 1997 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 215957
13 January 1997 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1099244
19 December 1996 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1095971
22 May 1996 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1085092
13 February 1996 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 877075
10 January 1996 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 873649
13 March 1995 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 856593
3 January 1995 Re-Inspection · Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1165262
17 February 1994 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 853043
3 January 1994 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 851329
10 March 1993 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 839058
9 January 1993 Re-Inspection · Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 828256
22 January 1992 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 951786
10 January 1992 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1264260
19 December 1991 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 953028
10 January 1991 Hull Examination · Initial Certification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 917354

Deficiency record · 54

Construction/Loadline › Hull › Hull Plating
Issued 14 February 2011 Resolved
Areas indicated on the hull by marine inspector shall ground to good material; area shall remain open until re-inspected by marine inspector.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 14 February 2011
Resolved 23 February 2011
Engineering › Steering Gear System › Rudder
Issued 14 February 2011 Resolved
Install rudder stops.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 February 2011
Resolved 17 February 2011
Engineering › Steering Gear System › Hydraulic Hose
Issued 14 February 2011 Resolved
Installed approved hoses on rudder actuator that meet SAE J-1942 standard.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 14 February 2011
Resolved 23 February 2011
Engineering › Fuel Oil Service System › Tank
Issued 14 February 2011 Resolved
Port side fuel tank forward of the fuel fill is wasted to a depth of one eight of an inch thick; owner to provide a plan for hydrostatic testing at every dry dock or install a new approved tank.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 February 2011
Resolved 23 February 2011
Stability › Watertight Integrity › General
Issued 14 February 2011 Resolved
Remove old and install new spool pieces on the vessel. New spool pieces to provide equal strength and heat resistivity of the hull material.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 14 February 2011
Resolved 23 February 2011
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 25 February 2010 Resolved
Vessel can carry no more than 21 people onboard until the additional 03 Type 1 adult lifejackets are provided onboard.
Action required: 705 - Other - as specified
Due 11 March 2010
Resolved 11 March 2010
Lifesaving › Hand Flares › Quantity
Issued 25 February 2010 Resolved
Provide 02 red hand flares for a total of 06 hand flares IAW 46 CFR 180.68(a).
Action required: 705 - Other - as specified
Due 11 March 2010
Resolved 11 March 2010
Engineering › Bilge Water Management System › Pump
Issued 25 February 2010 Resolved
Properly secure the aft electric submersible bilge pump float and the stbd fuel shut off manifold in the aft compartment.
Action required: 705 - Other - as specified
Due 11 March 2010
Resolved 11 March 2010
Documentation › Certificates/Documents › FCC SSL
Issued 4 February 2009 Resolved
Provide onboard FCC radiotelephony Permit.
Action required: 705 - Other - as specified
Due 28 February 2009
Resolved 16 March 2009
Navigation › Piloting/Steering › US Coast Pilot
Issued 4 February 2009 Resolved
Proivde onboard US Coast Pilot for operating area.
Action required: 705 - Other - as specified
Due 19 February 2009
Resolved 12 February 2009
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 4 February 2009 Resolved
Replace battery in water light for ring buoy.
Action required: 705 - Other - as specified
Due 28 February 2009
Resolved 16 March 2009
Lifesaving › Lifefloat › Serviceable
Issued 4 February 2009 Resolved
Repair as original or replace life float and associated lines.
Action required: 705 - Other - as specified
Due 28 February 2009
Resolved 16 March 2009
Documentation › Certificates/Documents › Certificate of Inspection
Issued 4 February 2009 Resolved
Prior to carriage of passengers, complete credit dry dock in the presents of a US Coast Guard Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 February 2009
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 4 February 2009 Resolved
Provide 1 adult life jacket prior to carriage of 24 adults onboard.
Action required: 705 - Other - as specified
Due 19 February 2009
Resolved 12 February 2009
Engineering › Bilge Water Management System › Interface Detector
Issued 11 December 2007 Resolved
Prove proper operation of steering gear compartment high water alarm visual indicator.
Action required: 705 - Other - as specified
Due 31 December 2007
Resolved 11 December 2007
Resolution: e-mail
Lifesaving › Hand Flares › Expired
Issued 11 December 2007 Resolved
Provide 06 current orange hand smoke flares. Flares expire 12/07.
Action required: 705 - Other - as specified
Due 31 December 2007
Resolved 11 December 2007
Resolution: e-mail
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 11 December 2007 Resolved
Provide proof of Fixed and portable fire extinguisher servicing report.
Action required: 705 - Other - as specified
Due 24 January 2008
Resolved 23 January 2008
Resolution: E-mail
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 26 January 2006 Resolved
Provide current Navigational Publications for area of operation. Coast Pilot, CG Light List, Tides and Currents.
Action required: 705 - Other - as specified
Due 3 February 2006
Resolved 30 January 2006
Documentation › Certificates/Documents › FCC SSL
Issued 16 February 2005 Resolved
Provide current FCC Station License.
Due 15 March 2005
Resolved 22 February 2005
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 16 February 2005 Resolved
Provide copy of Annual Fixed Fire Protection Inspection.
Due 22 February 2005
Resolved 16 February 2005
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 16 February 2005 Resolved
Provide proof of Pre-employment Drug testing and a copy of 2003 MIS report.
Due 15 March 2005
Resolved 22 February 2005
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 16 February 2005 Resolved
Provide current Coast Pilot [name withheld], and Current tables.
Due 15 March 2005
Resolved 22 February 2005
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 16 February 2005 Resolved
Provide Floating Electric Waterlight for Ring bouy.
Action required: 705 - Other - as specified
Due 15 March 2005
Resolved 16 February 2005
Engineering › Bilge Water Management System › Piping
Issued 16 February 2005 Resolved
Properly mount all bilge piping in Engineroom.
Action required: 705 - Other - as specified
Due 15 March 2005
Resolved 22 February 2005
Electrical › Electrical Distribution System (service) › Cable
Issued 16 February 2005 Resolved
Properly secure wiring and cables in engineroom.
Due 15 March 2005
Resolved 22 February 2005
Lifesaving › Buoyant Apparatus › Float-free Link
Issued 16 February 2005 Resolved
Properly attach Float free Link to Buoyant Apparatus.
Due 16 February 2005
Resolved 16 February 2005
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 16 February 2005 Resolved
Provide one B-I fire extinguisher at operators station.
Due 16 February 2005
Resolved 16 February 2005
Lifesaving › Embarkation Appliances/Stations › Handholds
Issued 2 February 2005 Resolved
Repair all cracked or wasted welds on port and starboard bench seating areas. Repair forward and aft handrails. The starboard seat has five broken welds, port seat one broken weld, aft rail two pad eyes are broken. Forward handrail wire rope has chaffed through.
Action required: 705 - Other - as specified
Due 1 March 2005
Resolved 15 February 2005
Construction/Loadline › Hull › Strut/Cross Tie
Issued 1 February 2005 Resolved
Reseal shaft strut hull penetrations.
Action required: 705 - Other - as specified
Due 1 March 2005
Resolved 15 February 2005
Lifesaving › Buoyant Apparatus
Issued 4 February 2004 Resolved
Provide proof of proper weak link IWO life float painter.
Condition: Unknown
Due 4 February 2004
Resolved 4 March 2004
Engineering › Bilge Water Management System
Issued 4 February 2004 Resolved
Prove proper operation of fixed bilge system. LEGACY COMPONENT DESC: Pump
Condition: Improper/Lack of Maintenance
Due 4 March 2004
Resolved 25 February 2004
Engineering › Bilge Water Management System
Issued 4 February 2004 Resolved
Provide a hand portable fire pump. LEGACY COMPONENT DESC: Pump
Condition: Improper/Lack of Maintenance
Due 4 February 2004
Resolved 25 February 2004
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 4 February 2004 Resolved
Maintain a training log and conduct required training.
Condition: Improper/Lack of Maintenance
Due 4 March 2004
Resolved 25 February 2004
Lifesaving › Buoyant Apparatus
Issued 11 January 2002 Resolved
Provide 2 paddles for the life float. LEGACY COMPONENT DESC: Paddles
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 January 2002
Resolved 18 February 2003
Lifesaving › Buoyant Apparatus
Issued 11 January 2002 Resolved
Properly stencil the number of persons maximum on the life float. LEGACY COMPONENT DESC: Markings
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 January 2002
Resolved 18 February 2003
Lifesaving › Lifebuoys
Issued 11 January 2002 Resolved
Replace the line around the life ring buoy and to the waterlight. LEGACY COMPONENT DESC: Life Line
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 January 2002
Resolved 18 February 2003
Engineering
Issued 6 February 2001 Resolved
After replacing MDE, shaft and bearing, make vessel available for inspection prior to placing vessel back in the water.
Condition: Unknown
Due 6 February 2001
Resolved 6 February 2001
Fire Fighting
Issued 20 December 1999 Resolved
Provide auto shut-down of MDE upon discharge of FE-241 agent. System to betested at the bottle connector._x001C_ Vessel not to carry passengers until repaired and inspected.
Condition: Unknown
Due 27 December 1999
Resolved 25 January 2000
Documentation
Issued 23 December 1997 Resolved
CORRECT DOCUMENT TO INCLUDE "COASTWISE" ENDORSEMENT.
Condition: Unknown
Due 23 December 1997
Resolved 23 December 1997
Documentation
Issued 10 January 1996 Resolved
PROCURE COPIES OF 46 CPF PART 16 & "T" REGS.
Condition: Unknown
Due 10 January 1996
Resolved 10 January 1996
Unknown
Issued 10 January 1996 Resolved
PROVE COMPIANCE WITH DRUG TESTING PROGRAM
Condition: Unknown
Due 17 January 1996
Resolved 17 January 1996
Lifesaving
Issued 10 January 1996 Resolved
PLACE VESSEL NAME & CAPACITY ON LIFE FLOAT
Condition: Unknown
Due 10 January 1996
Resolved 10 January 1996
Navigation
Issued 3 January 1995 Resolved
PROVE PROPER OPERATION OF EMERGENCY STEERING TILLER.
Condition: Unknown
Due 3 January 1995
Resolved 3 January 1995
Documentation
Issued 3 January 1994 Resolved
SUBMIT WRITTEN PROOF OF A CHEMICAL TESTING PROGRAM WHICH COMPLIES WITH 46 CFR PART 16 TO COAST GUARD MSO MIAMI.
Condition: Unknown
Due 3 January 1994
Resolved 3 January 1994
Documentation
Issued 3 January 1994 Resolved
PROVIDE COPY OF A VALID FCC RADIO OPERATOR PERMIT FOR VESSELS MASTER.
Condition: Unknown
Due 3 January 1994
Resolved 3 January 1994
Documentation
Issued 9 January 1993 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 9 January 1993
Resolved 9 January 1993
Lifesaving
Issued 9 January 1993 Resolved
REPLACE/REPAIR LIFE FLOAT IN AREAS OF DETERIATION, REPLACE RETRO-REFLECTIVEMATERIAL, REPLACE LINE TO LIGHT.
Condition: Unknown
Due 9 January 1993
Resolved 9 January 1993
Fire Fighting
Issued 9 January 1993 Resolved
PROVIDE ONE B-II FIRE EXTINGUISHER WITH BRACKET.
Condition: Unknown
Due 9 January 1993
Resolved 9 January 1993
Electrical
Issued 9 January 1993 Resolved
REPAIR EMERGENCY LIGHT OR PROVIDE FLASHLIGHT FOR VESSEL/ REPAIR OVERHEAD LIGHT IN MAIN CABIN (OVER ENGINE).
Condition: Unknown
Due 9 January 1993
Resolved 9 January 1993
Navigation
Issued 9 January 1993 Resolved
PROVIDE EMERGENCY TILLER.
Condition: Unknown
Due 9 January 1993
Resolved 9 January 1993
Construction/Loadline
Issued 9 January 1993 Resolved
REPAIR LATCHES ON HATCHES TO LAZERETTE AND MID-COMPARTMENT.
Condition: Unknown
Due 9 January 1993
Resolved 9 January 1993
Navigation
Issued 19 December 1991 Resolved
PROVIDE ALL AROUND WHITE LIGHT OR STERN LIGHT BY 15JAN92. NO NIGHT VOYAGES_x001C_UNTIL COMPLETED.
Condition: Unknown
Due 15 January 1992
Resolved 24 January 1992
Documentation
Issued 19 December 1991 Resolved
PROVIDE COPY OF FLG OPERATORS PERMIT FOR INSPECTION.
Condition: Unknown
Due 15 January 1992
Resolved 24 January 1992
Documentation
Issued 19 December 1991 Resolved
PROVIDE ORIGINAL C.O.I. FOR ENDORSEMENT BY 15JAN92.
Condition: Unknown
Due 15 January 1992
Resolved 24 January 1992

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.