Records from 2016 to 2017. Most recent: inspection, 16 October 2017.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 5 January 2017
Resolved
Prove proper operation of both port & stbdsides pre-engineered CO2 systems, including emergency overrides.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 January 2017
Resolution: Port & stbdside pre-engineered CO2 system were found operational.
Fire Fighting › Remote Fuel Shutoff › General
Issued 5 January 2017
Resolved
Prove proper operation of port and stbd fuel shutoff valves by closing completely and anchor cables at the operating station.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 January 2017
Resolution: Witnessed the proper operation of both port & stbd fuel shut offs.
Sail Rigging › Running Rigging › Halyards
Issued 5 January 2017
Resolved
Install missing chafing gear for main halyard rope at mast, and repair missing shaved wood and FRP.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 January 2017
Resolved 31 January 2017
Resolution: Chafing gear was installed and mast was repaired
Sail Rigging › Sails › Correct Sail Area of Record
Issued 5 January 2017
Resolved
Provide certification for measurements of main sail/jib IAW Stability Letter.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 January 2017
Resolved 25 January 2017
Resolution: Certification was provided, both sails measured less than the approved sail plan approved by MSC.
Communications › Radio Communications › EPIRB
Issued 5 January 2017
Resolved
Provide required spool missing from EPIRB.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 January 2017
Resolved 25 January 2017
Resolution: A replacement lanyarn was provided by local contractor and installed in the EPIRB.
Navigation › Piloting/Steering › Magnetic Compass
Issued 5 January 2017
Resolved
Replace magnetic compass due to fractured glass.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 January 2017
Resolved 25 January 2017
Resolution: A new magnetic compass was installed.
Communications › Radio Communications › VHF Radiotelephone
Issued 5 January 2017
Resolved
VHF-DSC radio must be properly connected to a GPS receiver or have a integral GPS radio IAW 47CFR80.59.
Action required: 705 - Other - as specified
Due 5 February 2017
Resolved 25 January 2017
Resolution: A new GPS VHF Ready radio was installed.
Communications › Alarms/Indicators › Bilge Alarm
Issued 5 January 2017
Resolved
Install audible and visual bilge alarms system at the operating station. 46CFR182.530(a).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 January 2017
Resolution: A repeater was installed at the operating station with a loder alarm and larger visual alarm.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 5 January 2017
Resolved
Submit a proposal to install a more effective means to close ventilation in both port & stbd engine rooms.
Action required: 705 - Other - as specified
Due 15 March 2017
Resolved 15 March 2017
Resolution: Witnessed the proper operation of 4 new installed aluminum ventilation dampers and confirmed airtightness.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 5 January 2017
Resolved
Engine Room Hatch Covers must be made airthight.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 January 2017
Resolution: New rubber gaskets were installed in port & stbd side.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 5 January 2017
Resolved
Properly seal all holes and penetrations found on each bulkhead in both port & stbdside engine rooms, CO2 protected spaces.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 January 2017
Resolution: All holes and penetrations were sealed in port & stbd engine rooms.
Engineering › Sea-water System (primary cooling) › Pump
Issued 5 January 2017
Resolved
Properly repair/replace raw cooling water leak located at the pump on stbdside MDE.
Action required: 705 - Other - as specified
Due 31 January 2017
Resolved 25 January 2017
Resolution: A new pump was installed, tested the engine and leak was corrected.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 23 December 2016
Resolved
Vessel O/O must be in compliance with DAPI Program. Vessel new master was not enrolled in the consortium and lack the testing procedures upon a marine casualty.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 January 2017
Resolution: A successfull DAPi audit was performed during COI inpection.
Engineering › Bilge Water Management System › Pump
Issued 23 December 2016
Resolved
Submersible bilge pumps must be UL listed and approved type. 46CFR182.530(a).
Action required: 705 - Other - as specified
Due 31 January 2017
Resolved 23 January 2017
Resolution: All submersible bilge pumps were installed with UL approved listed type.
Sail Rigging › Mast Step › Base
Issued 23 December 2016
Resolved
Submit plans for improvements/modifications performed to the mast step.
Action required: 705 - Other - as specified
Due 5 February 2017
Resolved 25 January 2017
Resolution: A plan was submitted to MSC, copy in file.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 26 September 2016
Resolved
Clean up propellors.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 19 October 2016
Resolution: Owner cleaned propellors.
Construction/Loadline › Hull › Hull Plating
Issued 26 September 2016
Resolved
Replace anodes.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 19 October 2016
Resolution: Owner replaced anodes.
Construction/Loadline › Hull › Keel
Issued 26 September 2016
Resolved
Grind back to good material water intrusion marked with blue chalk fwd port propellor.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 19 October 2016
Resolution: Owner grinded back to good material and repaired.
Construction/Loadline › Structures › Superstructure
Issued 26 September 2016
Resolved
Repair proposal for stbd aft rudder and added structure members on stbd deck.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 19 October 2016
Resolution: Owner created repair proposal and did repairs.
Lifesaving › Buoyant Apparatus › Serviceable
Issued 26 September 2016
Resolved
Replace 3 ring buoys and attached white lines.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 14 December 2016
Resolution: Cleared during COI inspection 14DEC2016 activity number 6048250. All lifesaving equipment was checked.
Deck/Cargo › Mooring/Anchoring › Anchoring Arrangement
Issued 26 September 2016
Resolved
Replace frayed anchor line.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 14 December 2016
Resolution: Cleared during COI inspection 14DEC2016 activity number 6048250. All lifesaving equipment was checked.
Construction/Loadline › Hull › Bottom Plating
Issued 26 September 2016
Resolved
Repair crack on stbd aft keel below propellor.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 19 October 2016
Resolution: Owner repaired crack on stbd keel propellor below.
Construction/Loadline › Hull › Bracket
Issued 26 September 2016
Resolved
Repair/replace bent washer on propellor.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 19 October 2016
Resolution: Owner repaired bent washer on propellor.
Construction/Loadline › Hull › Bottom Plating
Issued 26 September 2016
Resolved
Repair stbd aft cracked railing.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 14 December 2016
Resolution: Cleared during COI inspection 14DEC2016 activity number 6048250. All lifesaving equipment was checked.
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 September 2016
Resolved
Fix exposed wiring in the center aft inspection port.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 14 December 2016
Resolution: Cleared during COI inspection 14DEC2016 activity number 6048250. All lifesaving equipment was checked.
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 September 2016
Resolved
Fix exposed wiring in the port inboard storage compartment.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 14 December 2016
Resolution: Cleared during COI inspection 14DEC2016 activity number 6048250. All lifesaving equipment was checked.
Construction/Loadline › Hull › Hull Plating
Issued 26 September 2016
Resolved
Port side aft water intrusion just fwd port propellor.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 19 October 2016
Resolution: Owner grinded back to good wood and repaired.
Engineering › Fuel Oil Service System › Filter
Issued 23 February 2016
Resolved
REPLACE FUEL OIL FILTER WITH SUITABLE MARINE TYPE. 46 CFR 182.20-40(b)(5)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 March 2016
Resolved 9 March 2016
Resolution: Provided.
Documentation › Markings/Placards › Official Number (US)
Issued 23 February 2016
Resolved
OFFICIAL NUMBER NOT PERMANENTLY AFFIXED.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 March 2016
Resolved 9 March 2016
Resolution: NUMBER WAS PERMANENTLY ATTACHED TO TRANSVERSE BULKHEAD.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 23 February 2016
Resolved
EPIRB HYDROSTATIC RELEASE EXPIRATION DATE NOT INDICATED ON UNIT.
Condition: Improper/Lack of Maintenance
Due 26 March 2016
Resolved 9 March 2016
Resolution: NEW HYDROSTATIC RELEASE WAS INSTALLED AND PROPERLY MARKED IN THE PRESENCE OF ATTENDING MARINE INSPECTORS.
Electrical › Electrical Distribution System (service) › Wiring
Issued 23 February 2016
Resolved
REPLACE THE BILGE SYSTEM, WIRING WITH MARINE GRADE WIRING.
Action required: 705 - Other - as specified
Due 26 March 2016
Resolved 9 March 2016
Resolution: New marine grade wiring installed for electric submersible pumps.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 23 February 2016
Resolved
REPLACE 8 ADULT LIFEJACKETS. VESSEL REDUCED TO 41 PASSENGERS ONBOARD.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 February 2016
Resolved 9 March 2016
Resolution: 8 NEW TYPE 1 ADULT LIFEJACKETS WERE PROVIDED.