MAURY USCG vessel records Sign in
← All vessels

MAERSK TANGIER

MAERSK TANGIER is a 1990 freight ship. The Coast Guard has recorded 35 inspections since 1990, most recently in November 2010, along with 7 deficiencies and 5 operational controls.

Records from 1990 to 2010. Most recent: inspection, 3 November 2010.

Built
1990
Last inspected
3 November 2010
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8905543 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
357317
Flag
LIBERIA
—
Maury page id
psix-357317

Inspections, by type

…with no type recorded21
Years with a record 14 calendar years (1990–2010)
The 35 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it17700 - Convention (Subpart B), Gross Ton
7244 - Convention (Subpart B), Net Ton
21232 - Dead Weight, Ton
29055 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 35

3 November 2010 Ballast Water Examination · ISPS III Exam · PII Safety Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3883785
24 March 2010 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3702092
24 February 2010 NPV Safety Exam · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3685242
17 February 2010 MARPOL Annex I Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3681015
15 April 2009 PII Safety Exam · ISPS III Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3452530
20 February 2009 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 3420960
19 February 2009 ISPS II Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3419798
1 May 2008 Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3196635
10 April 2008 MARPOL Annex I Examination · ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3180753
9 April 2008 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3180497
7 April 2008 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3179136
3 October 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3072226
5 September 2007 Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 3050310
16 June 2007 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2963417
13 June 2007 Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2960254
11 June 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2958870
9 May 2007 Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2925880
29 April 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2918483
10 April 2007 Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2904864
24 October 2006 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2807449
21 November 2005 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2543527
18 July 2005 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2431200
2 February 2005 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2285185
9 November 2004 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2237779
5 July 2004 Ballast Water Examination · NPV Safety Exam · MARPOL Annex I Examination · ISPS II Exam
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2122120
9 April 2001 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 288999
23 July 1998 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 418336
24 July 1997 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 406252
7 March 1997 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 84161
3 July 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 392927
12 May 1995 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 378235
15 November 1994 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 372474
12 November 1994 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 372332
10 May 1994 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 366616
13 November 1990 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 340309

Deficiency record · 7

Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 17 February 2010 Resolved
Pipe leading from the Hopper tank to the OWS suction pump has been removed. SOLAS (2004 Cons) Ch. I Reg. 11.
Action required: 705 - Other - as specified
Resolved 17 February 2010
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 17 February 2010 Resolved
Vessel cannot provide the last 18 months of records for the operation of the OWS. MEPC 107(49). Vessel must provide records from OCM to USCG for review.
Action required: 705 - Other - as specified
Due 24 February 2010
Resolved 19 February 2010
Resolution: Vsl provided print out of OCM records to USCG for review.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 17 February 2010 Resolved
Vsl's OWS in not configured in the manner in which it was surveyed, additonal. piping has been installed by Chief engineer on the suction side through which fresh water is infused into the system. OWS configuration must be approved by class prior to use of OWS. Vsls def has been extended to 3 March 2010.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 March 2010
Resolved 3 March 2010
Resolution: Class has given provisional approval for vessel''s OWS configuration., pending submission of OWS diagram to class hq in Copenhagen.
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 15 April 2009 Resolved
Hydrostatic Release Units on Life rafts does not have the complete assembly for proper operation, a total of 03 units are onboard.
Action required: 15 - Rectify deficiencies by next port
Due 22 April 2009
Resolved 22 April 2009
Lifesaving › Lifeboat › Carriage Requirement
Issued 9 May 2007 Resolved
Due to heavy weather the vessel lost it's free fall lifeboat en route to Charleston, SC. A Twenty man life raft must be installed in lieu of the lifeboat.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 May 2007
Resolution: Twenty man life raft placed on board vessel in a position where it can be easily moved from one side of the ship to the other.
Lifesaving › Lifeboat › Carriage Requirement
Issued 9 May 2007 Resolved
Vessel is to replace it's missing free fall lifeboat within 30 days.
Action required: 705 - Other - as specified
Due 9 June 2007
Resolved 16 June 2007
Resolution: Based on the Flag State exemption granted to this vessel on May 10, 2007 the deficiency is required to be corrected by July 16, 2007 to the satisfaction of the Flag State. Deficiency is considered to be resolved.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 9 May 2007 Resolved
During heavy weather a container fell and fractured and punctured cargo hatch cover. Vessel must repair hatch cover to ensure watertight integrity to the satisfaction of class.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 May 2007
Resolution: Report issued from attending Lloyd''s surveyor attesting to the stisfactiory repar to the cargo hatch cover.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.