Inspection history · 22
28 May 2026
Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 8286799
13 February 2025
Deficiency Check
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 8079378
26 September 2024
Internal Structural Exam · Administrative Inspection · Drydock Exam · Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 8009865
27 May 2024
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7920685
17 April 2024
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7893206
12 May 2023
Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7740008
30 November 2022
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7739994
29 November 2022
Examination of Repairs
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7601448
7 February 2022
Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7399830
19 January 2021
COI Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7128190
20 April 2020
Administrative Inspection
Administrative · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6942841
20 April 2020
Drydock Exam
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6973956
30 August 2019
Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6826438
13 June 2018
COI Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6451584
8 May 2018
Administrative Inspection
Administrative · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6409025
3 May 2018
In-Service Inspection · Administrative Inspection · Hull Examination · Examination of Repairs
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6404163
17 April 2017
Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6141565
25 October 2016
Deficiency Check
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6033447
4 October 2016
COI Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6012728
20 July 2016
Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 5948745
6 April 2016
Hull Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5849887
14 January 2016
Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 5797981
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 28 May 2026
Resolved
A hatch cover must be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss. Stbd void #2  hatch covers had unserviceable captive chains.
46 CFR 179.360 (b)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 June 2026
Resolution: MI received proof of deficiency rectification.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 28 May 2026
Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. MI found Life Float lanyards and lights where found unservicable. LBS route until repaired.
46 CFR 180.175 (a)
Action required: 705 - Other - as specified
Resolved 8 June 2026
Resolution: MI received proof of deficiency rectification.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 May 2026
Resolved
A vessel must carry one floating water light approved in accordance with § 161.010 in subchapter Q of this chapter attached to the ring life buoy. MI found the float light with an unservicable battery. Reduce operations to daylight only.
46 CFR 180.70 (d)(1)
Action required: 705 - Other - as specified
Resolved 18 June 2026
Resolution: MI reviewed proof of all deficiency rectification.
11 - Life Saving Appliances › N/A - No Subsystem › Means of rescue
Issued 28 May 2026
Resolved
The master and crew of a vessel will be familiar with the content the emergency instructions containing the actions to be taken in the event of a man overboard. Crew was missing the MOB crew life jacket lanyard. Crew member shall have a lanyard prior to passengers.
46 CFR 185.510 (a)
Action required: 10 - Deficiency Rectified
Resolved 8 June 2026
Resolution: MI received proof of deficiency rectification.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 28 May 2026
Resolved
Each disposable hydrostatic release unit must be marked with an expiration date of two years after the date on which the unit is installed. Hydrostatic release was not serviceable.
46 CFR 185.740 (b)
Action required: 705 - Other - as specified
Resolved 18 June 2026
Resolution: MI recieved proof of deficiency rectification.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 28 May 2026
Resolved
A hatch exposed to the weather must be watertight. The stbd aft hatch was missing components. Reduce route to LBS and limit to operation in less than three foot seas.
46 CFR 179.360 (a)
Action required: 705 - Other - as specified
Resolved 18 June 2026
Resolution: MI received proof of deficiency rectification.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 27 May 2024
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection. Vessel experienced an unintentional grounding. Receive in-service inspection prior to the carriage of passengers.
46 CFR 177.100
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 May 2024
Resolution: MI attended vessel and conducted underway sea trial and inspection.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 17 April 2024
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection. Vessels hull is pitted in both port and stbd void #2 impairing seaworthiness. Resubmit repair plan no latter than 08JUL24.
46 CFR 177.100
Action required: 705 - Other - as specified
Resolved 31 July 2024
Resolution: MI inspected temporary repair. All sat.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 17 April 2024
Resolved
A gas actuated valve or device must be capable of manual override at the valve or device. Repair prior to the carriage of passengers.
46 CFR 181.410(b)(7)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 April 2024
Resolution: MI visited vessel and inspected system. All sat
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 17 April 2024
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection. Vessels stbd FireBoy cylinder is waisted.
46 CFR 177.100
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 May 2024
Resolution: MI inspected new fireboy cylinder.
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 17 April 2024
Resolved
A vessel must be fitted with a FCC type accepted general marine radar system for surface navigation with a radar screen mounted at the primary operating station if the vessel is on a LBS plus LC Route. Radar is out of commission. Reduce pax to 49 on a LC route.
46 CFR 184.404 (a)(1)
Action required: 705 - Other - as specified
Resolved 25 May 2024
Resolution: MI witnessed repaired and operational radar.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 17 April 2024
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. MI found the mast head, stern & stbd nav light extinguished. The vessel is limited to daylight without reduced visibility operations.
46 CFR 183.420
Action required: 705 - Other - as specified
Resolved 25 April 2024
Resolution: MI visited vessel and inspected system. All sat
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 17 April 2024
Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in each normally unmanned space. Prove operation of the high water alarm of each space during the next MI attendance. Repair prior to the carriage of passengers.
46 CFR 182.530
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 April 2024
Resolution: MI visited vessel and inspected system. All sat
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 17 April 2024
Resolved
The EPIRB's battery is shall be replaced before the date required by FCC regulations in 47 CFR part 80. MI found EPIRB battery expired. Reduce route to LBS
46 CFR 185.728 (b)
Action required: 705 - Other - as specified
Resolved 25 April 2024
Resolution: MI visited vessel and inspected system. All sat
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 17 April 2024
Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. MI found Life Float paint faided.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 May 2024
Resolution: LF have been painted and inspected. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 17 April 2024
Resolved
Each life float must be fitted with an approve float light. LF light was extinguished. Limited to less than 57 pax on a LC route.
Action required: 705 - Other - as specified
Resolved 25 May 2024
Resolution: MI observed proper amount af LFs onboard according to the COI.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 17 April 2024
Resolved
Each vessel inspected and certificated under the provisions of this subchapter must be in full compliance with the terms of the COI. Vessels life float capacity does not match the COI. Reduce passengers on the LC route to 81 passengers.
46 CFR 176.100 (b)
Action required: 705 - Other - as specified
Resolved 25 May 2024
Resolution: MI observed deficiency correction.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 17 April 2024
Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 1 inch numbers and letters at the entranceway to that deck.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 May 2024
Resolution: MI observed deficiency correction.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 April 2024
Resolved
The vessel shall comply with all applicable stability requirements of the vessel's stability letter. Vessels free-board did not match the stability letter requirements. limit passengers to 65 max until resolved.
46 CFR 185.315 (a)
Action required: 705 - Other - as specified
Resolved 4 June 2024
Resolution: MSC contacted the MI and approved the actual freeboard, not the freeboard listed on the stability letter. MSC found an error within the stability letter and will re-issue a new stability letter.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 17 April 2024
Resolved
A pre-engineered fixed gas fire extinguishing system must be approved by the Commandant. MI found the system out of its service compliance date.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 April 2024
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 17 April 2024
Resolved
Each portable fire extinguisher on a vessel must be of an approved type. MI found three 40-B:C fire extinguisher waisted from corrosion. Replace IAW COI requirements and have serviced by technician.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 April 2024
Resolution: MI visited vessel and inspected. All sat
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 19 January 2021
Resolved
Engine room watertight bulkhead found to have penetrations allowing for air and water to pass from compartment to compartment.
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Due 19 January 2021
Resolved 22 January 2021
Resolution: Penetrations in watertight bulkhead sealed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 January 2021
Resolved
Dead end wires in steering console need to be capped off to prevent damage/fire.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 February 2021
Resolved 22 January 2021
Resolution: All unused wires pulled.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 19 January 2021
Resolved
Life floates do not have approved retro reflective tape.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 19 January 2021
Resolved 22 January 2021
Resolution: SOLAS II retroreflective tape installed on floats
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 19 January 2021
Resolved
Life ring does not have approved retro reflective tape.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 19 January 2021
Resolved 22 January 2021
Resolution: SOLAS retro tape installed
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 19 January 2021
Resolved
Life floats found with grab lines not attached due to prior damage.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 19 January 2021
Resolved 22 January 2021
Resolution: Different life floats were installed on vessel.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 19 January 2021
Resolved
Radio Safety Telephony found to be expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 February 2021
Resolved 19 January 2021
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 19 January 2021
Resolved
Life float spacers between life floats missing.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 19 January 2021
Resolved 22 January 2021
Resolution: wood blocks installed
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 20 April 2020
Resolved
Dry dock is out of date due to covid-19
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 May 2020
Resolved 20 May 2020
Resolution: conducted start of dry dock period
Construction/Loadline › Structures › Transverse Bulkhead
Issued 13 June 2018
Resolved
through hole fitting needs rplaced with similar metal
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 July 2018
Resolved 6 August 2018
Resolution: replaced in kind
Lifesaving › Lifefloat › Serviceable
Issued 13 June 2018
Resolved
repair missing chunks
08 days to conduct repairs
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 June 2018
Resolved 22 June 2018
Resolution: Repaired accoarding to manufacture
Engineering › Bilge Water Management System › Piping
Issued 4 October 2016
Resolved
Owner/operator was unable to prove prober operation of bilge pick-up in starboard lazzarette. Prior to carrying passengers, prove proper operation of bilge pick-up.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 October 2016
Communications › Alarms/Indicators › Bilge Alarm
Issued 4 October 2016
Resolved
Bilge high-level alarm panel light for starboard engine room is non-operational. Prior to carrying passengers, prove proper operation of alarm panel light.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 October 2016
Navigation › Piloting/Steering › Marine Charts
Issued 4 October 2016
Resolved
Vessel's chart is not updated. Update chart or place new or current chart on board.
Action required: 705 - Other - as specified
Due 18 October 2016
Resolved 25 October 2016
Construction/Loadline › Hull › Weld
Issued 6 April 2016
Resolved
14 washed/wasted welds ID'd during the drydock. Marked welds and discussed repairs with vessel rep.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 April 2016
Construction/Loadline › Penetrations › Weld
Issued 6 April 2016
Resolved
Depth sounder transducer guard is wasted beyond serviceability. Replace in kind.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 April 2016
Engineering › Steering Gear System › Rudder Bearing
Issued 6 April 2016
Resolved
Rudder and cutlass bearings are torn/wasted. Remove and replace.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 April 2016