Inspection history · 22
3 February 2026
Deficiency Check · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8306252
12 March 2025
Drydock Exam · Internal Structural Exam · Annual Inspection · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8093114
1 October 2024
Damage Survey
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8012743
26 September 2024
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8014002
23 February 2024
Internal Structural Exam · Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7875479
6 November 2023
COI Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7821524
12 October 2023
Drydock Exam · Examination of Repairs
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7807622
7 March 2023
Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7647145
8 March 2021
Examination of Repairs · COI Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7151956
11 March 2020
Administrative Inspection · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6924792
7 January 2020
Internal Structural Exam · Hull Examination · Administrative Inspection · Deficiency Check · Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6884510
30 May 2019
DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6699196
21 August 2018
Administrative Inspection · Damage Survey · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6521598
6 March 2018
Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6375429
9 January 2018
Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6334563
28 November 2017
Drydock Extension
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6314142
12 July 2017
Damage Survey
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6207612
21 April 2017
Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6133510
21 March 2017
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6122195
14 June 2016
Damage Survey
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5909070
25 March 2016
Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5848649
17 February 2016
Deficiency Check · DAPI Audit · COI Inspection · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5817032
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 3 February 2026
Resolved
Vessels constructed of wood must, in addition to paragraph (a), provide bilge level alarms in all watertight compartments except small buoyancy chambers.
Multiple high level alarms were inoperable and unable to be tested.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 February 2026
Resolved 1 May 2026
Resolution: Bilge alarms repaired and functional.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 3 February 2026
Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail.
Observed exposed rotating machinery in engine compartment.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 February 2026
Resolved 1 May 2026
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 15 April 2025
Resolved
Vessels constructed of wood must provide bilge level alarms in all watertight compartments. The alarm must be visual and audible and be provided at the operating station.
High water level alarm in stern steering compartment is inoperable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2025
Resolved 16 May 2025
Resolution: O/O sent video of bilge alarm operating correctly. Video attached in deficinecy documents.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 April 2025
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations.
Engine coolant resevoir is leaking coolant through a small crack near the cap.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2025
Resolved 16 May 2025
Resolution: O/O sent picture of resin patch for the crack on the coolant tank. Picture attached in deficiency documents.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 15 April 2025
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date U.S. Coast Pilot [name withheld] List, and tide tables.
Vessel's nautical publications on board are dated for 2023.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2025
Resolved 16 May 2025
Resolution: O/O sent Sector Charleston a picture of the 2025 nautical publications being placed on board. Picture is attached to deficiency documents.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 7 November 2023
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules.
Vessels port, starboard and stern lights inoperable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 November 2023
Resolved 17 November 2023
Resolution: Light bulbs were replaced to new.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 7 November 2023
Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR”.
Passenger access hatch missing label.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 November 2023
Resolved 17 November 2023
Resolution: The escape hatch was labeled as required by regulation.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 November 2023
Resolved
Each life jacket, immersion suit, and ring life buoy must be marked in clearly legible block capital letters with the vessel's name.
Several life jackets were not marked.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 November 2023
Resolved 17 November 2023
Resolution: Lifejackets were marked with vessel name.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 7 November 2023
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the COI.
Clamp is rotted in starboard side lazarette in way off existing sister repair. Section of clamp to be renewed to original. Provide repair proposal prior to commencement of repair.
*Due Feb 28, 2024
Action required: 705 - Other - as specified
Due 28 February 2024
Resolved 4 March 2024
Resolution: Repair made to clamp in starboard lazerette.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 6 November 2023
Resolved
A vessel on a lakes, bays, and sounds, or rivers route must carry: (1) Three hand red flare distress signals approved in accordance with § 160.021 in subchapter Q of this chapter, or other standard specified by the Commandant; and (2) Three hand orange smoke distress signals approved in accordance with § 160.037 in subchapter Q of this chapter, or other standard specified by the Commandant.
Vessel had 3 red hand flares and only 1 hand orange smoke, needs 2 additional hand orange smoke or additional 3 red hand flares to meet requirement.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 November 2023
Resolved 17 November 2023
Resolution: New flares were placed in service.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 March 2020
Resolved
A suitable marine type strainer shall be fitted in the fuel supply line in the engine compartment. Drip pans fitted with flame screens may be required under strainers other than those mounted to the engine. Show proper installation of strainer/drip pan.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 October 2020
Resolved 23 November 2021
Resolution: closed def due to not having COI
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 March 2020
Resolved
Shutoff valves shall be fitted at fuel tank. Emergency pull does not permit full closure of valves. Demonstrate proper operation of emergency fuel shut-off at tank for full closure of valves.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 October 2020
Resolved 23 November 2021
Resolution: closed def due to not having COI
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 11 March 2020
Resolved
Structural design shall meet the requirements of this regulation. Deck overlay over lazarette is delaminating. Demonstrate preservation of teak overlay and submit repair proposal by DEC 1, 2020 for permanent repairs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 December 2020
Resolved 23 November 2021
Resolution: closed def due to not having COI
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 30 May 2019
Resolved
Vessel's keelson aft of the rudder post is showing signs of deterioation. Submit to the local OCMI, repair proposal and estimated time frame within 30 days.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2019
Resolved 28 June 2019
Resolution: Repairs to be made during drydock 12/2019.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 30 May 2019
Resolved
Vessel to provide list of enrolled employees in consortium to local OCMI.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2019
Resolved 28 June 2019
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 6 March 2018
Resolved
DEMONSTRATE PORT AND STBD RUNNING LIGHTS ARE OPERATIONAL.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 March 2018
Resolved 12 March 2018
Lifesaving › Lifebuoys › Serviceable
Issued 21 March 2017
Resolved
Condition: Improper/Lack of Maintenance
Due 21 April 2017
Resolved 21 April 2017
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 21 March 2017
Resolved
Condition: Improper/Lack of Maintenance
Due 21 April 2017
Resolved 21 April 2017
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 14 April 2016
Resolved
Provide a proposal to bring the fuel tank into compliance with the regulations in way of the two flanged access ports on the tank's side. Cite: 46 CFR 182.440
Action required: 705 - Other - as specified
Due 14 May 2016
Resolved 13 May 2016
Resolution: Cleared def as of this date.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 23 February 2016
Resolved
Provide valid FCC Safety Radiotelephony Certificate. 47 CFR 13
Action required: 705 - Other - as specified
Due 15 March 2016
Resolved 9 March 2016
Resolution: Valid FCC Safety Radiotelephony certificate provided.
Fire Fighting › Portable CO2 Fire Extinguisher › Location
Issued 23 February 2016
Resolved
Label outside of cabinet or remove fire extinguisher in cabinet. 46 CFR 181.30-10(b)
Action required: 705 - Other - as specified
Due 8 March 2016
Resolved 8 March 2016
Resolution: Outside of the cabinet is labeled 'Fire Extinguisher Inside'.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 17 February 2016
Resolved
Verify proper brackets for fire extinguishers, and replace if found not correct. 46 CFR 181.30-10(b)
Action required: 705 - Other - as specified
Due 8 March 2016
Resolved 21 March 2017
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 17 February 2016
Resolved
Replace combustible trash cans with non-combustible trash cans. 46 CFR 177.405(f)
Action required: 705 - Other - as specified
Due 8 March 2016
Resolved 21 March 2017