FUJI BAY is a 1990 freight ship. The Coast Guard has recorded 24 inspections since 2016, most recently in September 2024, along with 15 deficiencies and 5 operational controls.
Records from 2016 to 2024. Most recent: inspection, 26 September 2024.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
The counts in the strip above are the same counts; this table splits the inspections by
the kind of activity recorded. A blank resolution means none was recorded in this data; it
does not establish that a deficiency is outstanding. Years with a record are calendar
years in which a record exists, not years in service.
What Maury does not do.
Documentation record
Tonnage as PSIX records it9070 - Simplified, Gross Ton 9070 - Convention (Subpart B), Gross Ton 5838 - Simplified, Net Ton 5838 - Convention (Subpart B), Net Ton 11540 - Dead Weight, Metric Ton 16744 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
What it gives that this page does not: the whole record in one
dated, citable document — every line with its Coast Guard activity id, the retrieval
date on the cover, built to print to PDF with its page breaks — that a surveyor can
attach and a lender can file. The same facts as this page, complete and in one file.
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
A request, not a checkout: leave an email and Maury replies once, with
the dated document for this hull and a Stripe invoice for $299. Nothing is charged before
the document is in your hands.
Used only to answer this request.
Not shared, not sold, and not added to a mailing list.
Inspection history · 24
26 September 2024Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8009810
20 September 2024COE-Administrative
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8006430
27 June 2024Bulk Liquid Transfer Monitor
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7943799
24 June 2024Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7940925
24 June 2024PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7941073
9 November 2023PSC B
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7820768
2 October 2023PSC B · Appeal · Deficiency Check · ISM Exam
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7801644
14 June 2022Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7477228
31 May 2022PSC B · Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7460948
23 May 2022PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7457090
20 May 2022Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7455190
3 August 2021PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7275877
2 June 2020PSC B · COE-Dockside
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6960665
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 9 November 2023Resolved
74SOLAS(01) II-2 / 6.5 - 07124
Fire extinguishers shall be periodically examined and subjected to such tests as the administration may require. One wheel foam extinguisher (45hr), one fixed dry powder (40hr), and one foam applicator were beyond the required annual inspections date as per the vessels SMS. The vessel requested service of extinguishers in Cape Town Africa but the inspections were missed by a third party.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 November 2023
Resolved 26 September 2024
Resolution: Vessel submitted Annual Firefighting equipment inspection documentation to SDB. Reviewed and cleared.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 2 October 2023Resolved
The company and the ship shall comply with the requirements of the International Safety Management Code. For the purpose of this regulation, the requirements of the Code shall be treated as mandatory. The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. In meeting these requirements, the company should ensure that any non-conformity is reported, with its possible cause, if known. The nature of the below deficiencies provides objective evidence of a serious failure of the implementation of the ISM Code. In addition to the deficiencies below, a Liberian flag inspector attended 1-hour prior to the start of PSC exam & cited 02 deficiencies including inoperable smoke detectors in the engine room and oil leakage and accumulation in the machinery spaces, and it was determined the vessels crew knew of a faulty heat detector testing appliance and stated that a new requisition was submitted. The crew was not able to provide the requisition or any evidence of purchase, as required by the ISM Code and the vessel’s SMS. An external ISM audit report, satisfactory to the Coast Guard, must be submitted prior to clearance of this deficiency and departure. 74 SOLAS (20) IX/3.1 ISM Code Part A/10.1 - 30 ABC
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 October 2023
Resolved 27 October 2023
Resolution: Received internal audit addressing exam items noted and proper corrective actions.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 October 2023Resolved
The function of the detection system shall be periodically tested to the satisfaction of the Administration by means of equipment producing hot air at the appropriate temperature. Vessel was found to be using an open flame torch to test heat detectors, which contradicted SMS procedures and manufacturer instruction and may have damaged vital fire detection equipment rendering it incapable of detecting a fire. 74 SOLAS (20) II-2/14.2.1.2. 30 ABC
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 2 October 2023
Resolved 3 October 2023
Resolution: Vessel submitted a reacquisition order for a new testing device and has reviewed the SMS procedures for testing detection devices onboard. Vessels class attested to the correction after heat detector was replaced and order placed for new test device.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 2 October 2023Resolved
Oil fuel pipes, which if damaged, would allow oil to escape from a storage, settling or daily service tank having a capacity of 500 l and above situated above the double bottom, shall be fitted with a cock or valve directly on the tank capable of being closed from a safe position outside the space. The quick closing line handle that is located outside of the EDG space broke during testing not allowing the generator to be shut off remotely in case of fire. 74 SOLAS (97) II-2/15.2.5. - 30 ABC
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 2 October 2023
Resolved 3 October 2023
Resolution: Vessel repaired the broken line leading to the quick close valve on the EDG tank. deficiency was verified rectified by the vessels class.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 October 2023Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. 01 portable rolling CO2 applicator found to be covered with oil, and 01 foam applicator found with a kinked hose thus rendering them inoperable or potentially ineffective. Appliances were located near the #1 generator. 74 SOLAS (20) II-2/14.2.1.2. - 17 AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 2 October 2023
Resolved 3 October 2023
Resolution: Rolling applicator was cleaned and the extinguisher with kinked hose was replaced. Vessels minimum additional extinguishers were verified.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 2 October 2023Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to moving parts. Vessel’s generator shafts were found to have exposed rotating machinery which could lead to injury as well as damages to loose rubber hoses near the exposed area. 74 SOLAS (04) II-1/26.1 - 17AC
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 2 October 2023
Resolved 3 October 2023
Resolution: Vessel redirected loose hose and added safe-guards to prevent injury and damages from rotating machinery equipment.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 2 October 2023Resolved
Class A fire boundary doors leading to engine space and steering gear room are fitted with 2 kinds of hold backs: lines and metal hooks. Unauthorized hold backs on Class A boundaries pose severe threat to required containment of shipboard fires. 74 SOLAS (97) II-2/47.2 - 17 AC
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 2 October 2023
Resolved 3 October 2023
Resolution: Hold backs were removed.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 2 October 2023Resolved
The arrangements for the storage, distribution and utilization of other flammable oils employed under pressure in power transmission systems, control and activating systems and heating systems shall be such as to ensure the safety of the ship and persons on board. Steering gear piping was found to be leaking hydraulic oil at a flange above the steering drive motor, creating a hazard. 74 SOLAS (97) II-2/15.4 - 17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 2 October 2023
Resolved 3 October 2023
Resolution: Vessel replaced gaskets on pipe connections which stopped further leaking oil.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of Lifeboats
Issued 31 May 2022Resolved
11103 - Stowage and provision of Lifeboats - All lifesaving appliances prescribed in this part shall: not be damaged in stowage. PSCOs observed damage to keel of both port and stbd lifeboats in way of the gripes.
74 SOLAS 97 III/30.2.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2022
Resolved 14 June 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 May 2022Resolved
THE CONDITION OF THE SHIP AND IT'S EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTES WILL REMAIN FIT TO PROCCED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ONBOARD.
PSCO IDENTIFIED A RAW WATER PIPE IN THE ENGINE ROOM BENEATH THE DECKPLATE WITH A HOLE IN THE SIDE OF THE PIPS THAT WAS SPRAYING A CONSTANT STREAM OF WATER INTO THE BILGE.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 25 May 2022
Resolved 24 May 2022
Resolution: Received class report stating repair had been completed
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 8 August 2018Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Port side lifeboat lifeline was missing one bolt. Creating an opening in the hull.
Action required: 10 - Deficiency Rectified
Due 8 August 2018
Resolved 8 August 2018
Resolution: Deficiency was corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 8 August 2018Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. The overhead insulation in the main engine space near the air tanks was damaged.
40AC
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 8 August 2018
Resolved 20 November 2018
Resolution: See attached class report
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 8 July 2016Resolved
74SOLAS(14)I/11 0720 PSCO witnessed 02 fire extinguishers hose's showing excessive signs of wearing that were located in the engine room.
Action required: 705 - Other - as specified
Due 22 July 2016
Resolved 31 August 2016
Resolution: Lloyd's supplied a report that stated all F/E in the Engine Room were changed out for new ones while in the Puerto Boliva, Equador.
74Solas(97)II-2/15.3 1420 PSCO identified excesive oil collecting under all three generator drive shafts.
Action required: 705 - Other - as specified
Resolved 8 July 2016
Resolution: Corrected on the spot.
Fire Fighting › Ventilation Systems › Ducts
Issued 8 July 2016Resolved
74Solas(97) II-2/16 0710 PSCO identified non permanent ventilation in engine room.
Action required: 705 - Other - as specified
Resolved 8 July 2016
Resolution: corrected on the spot.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.