EVINOS is a 1984 tank ship. The Coast Guard has recorded 36 inspections since 1990, most recently in October 2006, along with 8 deficiencies and 7 operational controls.

Records from 1990 to 2006. Most recent: operational control imposed, 9 October 2006.

Built
1984
Last inspected
9 October 2006
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8307442 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
357913
Flag
LIBERIA
—
Maury page id
psix-357913

Inspections, by type

…with no type recorded19
Years with a record 10 calendar years (1990–2006)
The 36 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 20 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it17584 - Convention (Subpart B), Net Ton
73987 - Displacement, Ton
61728 - Dead Weight, Ton
17584 - Simplified, Net Ton
36674 - Convention (Subpart B), Gross Ton
36674 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

STOLT PERSEVERANCE Tank Ship · MISLE 40502 · 12 December 2005 · activity 2550553

Inspection history · 36

9 October 2006 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2796698
7 September 2006 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2771505
7 September 2006 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2772828
1 September 2006 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2765805
27 August 2006 Ballast Water Examination · MARPOL Annex I Examination · MARPOL Annex V Examination · ISPS II Exam · COC-TVE Annual
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2759158
27 August 2006 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2761131
12 December 2005 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2549773
12 December 2005 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2550553
9 December 2005 MARPOL Annex I Examination · Random ISPS/MTSA/PSC · MARPOL Annex V Examination · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2548316
9 December 2005 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2549013
5 December 2005 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2546359
5 October 2005 Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2508297
17 March 2005 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2313026
15 March 2005 COC-CHEM Renew · ISPS III Exam · Ballast Water Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2311082
8 December 2004 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2255804
8 October 2004 NPV Safety Exam
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2216617
27 July 2004 ISPS II Exam
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2146414
1 April 2004 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2035462
12 March 2004 Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2023151
11 March 2004 Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2022472
6 January 2004 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1975927
11 April 2003 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1772032
12 March 2003 Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1752397
23 July 2002 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1650971
13 March 2002 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1493623
24 February 2002 Tank Vessel Examination · Certificate of Compliance
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1488851
20 October 2000 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 283955
20 October 2000 Tank Vessel Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 823117
3 October 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 433442
3 October 1999 Tank Vessel Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1352633
1 October 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 433379
8 August 1998 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 129618
22 June 1998 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 416841
22 June 1998 Tank Vessel Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1127086
26 January 1992 Certificate of Compliance
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1258575
19 November 1990 Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1236698

Deficiency record · 8

Navigation › Collision/Grounding Avoidance › Radar
Issued 9 October 2006 Resolved
Received Request for a LOD. Primary radar inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 October 2006
Resolution: Received technician’s report. Replaced defective control panel.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 25 August 2006 Resolved
One fireman's outfit is severely deteriorated. Provide protective clothing from fireman's outfit to protect the skin from the heat radiating from the fire and from burns. the outer surface must be water-resistant. Prior to next US Port.
Action required: 15 - Rectify deficiencies by next port
Resolved 7 September 2006
Resolution: One fireman''s outfit has been replaced.
Construction/Loadline › Hull › Bottom Plating
Issued 12 December 2005 Resolved
Vessel ran aground while transitting the Savannah River. The vessel is hereby directed to conduct an underwater survey of the ship's hull prior to departure from the Port of Savannah, GA. A classification society surveyor shall verify the integrity of the vessel's hull and submit an acceptable report to Marine Safety Unit Savannah for review and approval prior to departure.
Action required: 705 - Other - as specified
Due 13 December 2005
Resolved 13 December 2005
Navigation › Piloting/Steering › Gyro Compass
Issued 8 October 2004 Resolved
Provide tech report attesting to satisfactory operation of Gyro-compass.
Condition: Placed in Improper Service
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 10 October 2004
Resolved 9 October 2004
Construction/Loadline
Issued 20 October 2000 Resolved
Vessel to have loadline markings painted.
Condition: Unknown
Due 26 November 2000
Resolved 26 November 2000
Navigation
Issued 22 June 1998 Resolved
AUTOMATIC RADAR PLOTTING AID (ARPA) NOT OPERATING PROPERLY. THE 5VDC PWR SUPPLY WAS NOT WORKING CORRECTLY.
Condition: Unknown
Due 24 June 1998
Resolved 27 June 1998
Unknown
Issued 19 November 1990 Resolved
PROVIDE A MECHANICAL MEANS OF CLOSURE FOR PORT AND STARBOARD FUEL OIL VENT CONTAINMENT PRIOR TO BUNKERING IN U.S. WATERS.
Condition: Unknown
Due 19 November 1990
Resolved 19 November 1990
Deck/Cargo
Issued 19 November 1990 Resolved
DEMONSTRATE PROPER OPERATION OF CARGO PUMP EMERGENCY SHUTDOWN PRIOR TO DISCHARGING CARGO IN U.S. WATERS.
Condition: Unknown
Due 19 November 1990
Resolved 19 November 1990

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.