Records from 1990 to 1994. Most recent: inspection, 18 November 1994.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 11
18 November 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 372624
18 November 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 869637
18 May 1994
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 367083
18 May 1994
Control Verification
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 860273
14 December 1993
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 647861
5 October 1993
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 361325
19 April 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 357546
26 August 1992
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 497075
13 March 1992
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 349139
14 January 1992
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 348281
18 December 1990
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 340904
Electrical
Issued 18 November 1994
Resolved
INADEQUATE LIGHTING IN THE BOSIN STORES AND PAINT LOCKER.
Condition: Unknown
Due 18 December 1994
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 18 November 1994
Resolved
GROUND ON PHASE "S" 380 VOLTS CIRCUIT.
Condition: Unknown
Due 18 December 1994
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 18 November 1994
Resolved
INADEQUATE LIGHTING IN THE EMERGENCY BATTERY ROOM.
Condition: Unknown
Due 18 December 1994
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 18 November 1994
Resolved
#1 FIRE PUMP DOES NOT WORK.
Condition: Unknown
Due 18 December 1994
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Accommodation/Occupational Safety
Issued 18 November 1994
Resolved
VENT SCREEN IN GALLEY MISSING OVER STOVE.
Condition: Unknown
Due 18 December 1994
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 18 November 1994
Resolved
REPLACE, REPAIR LIGHTS IN HOSPITAL SPACE.
Condition: Unknown
Due 18 December 1994
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 18 May 1994
Resolved
REPAIR STBD AND PORT LIFEBOATS IN WAY OF GUNWALE AS RECOMMENDED BY CLASS SAFETY CERTIFICATE DATED 9MAY94.
Condition: Unknown
Due 23 May 1994
Resolved 23 May 1994
Fire Fighting
Issued 18 May 1994
Resolved
PROVIDE ON BOARD APPROPRIATE FIRE HOSE NOZZLES PRIOR TO DEPARTING. NUMBER TO COININCIDE WITH THE NUMBER OF FIRE STATIONS ON BOARD.
Condition: Unknown
Due 25 May 1994
Resolved 23 May 1994
Accommodation/Occupational Safety
Issued 18 May 1994
Resolved
PLACE ON BOARD A STRETCHER FOR MEDICAL EQUIPMENT PRIOR TO DEPARTING.
Condition: Unknown
Due 25 May 1994
Resolved 23 May 1994
Navigation
Issued 18 May 1994
Resolved
PROVIDE ON BOARD CURRENT COPIES OF COAST PILOT AND SAILING DIRECTIONS PRIORTO DEPARTURE.
Condition: Unknown
Due 25 May 1994
Resolved 23 May 1994
Unknown
Issued 18 May 1994
Resolved
PROVIDE APPRORIATE NUMBER OF MATES CORRESPONDING TO SAFE MANNING CERTIFICATE PRIOR TO DEPARTING.
Condition: Unknown
Due 25 May 1994
Resolved 23 May 1994
Lifesaving
Issued 18 May 1994
Resolved
PROPERLY INSTALL PORT AND STBD LIFERAFTS AND HYDROSTATIC RELEASES PRIOR TO DEPARTURE TO SATISFACTION OF ATTENDING CG MARINE INSPECTOR.
Condition: Unknown
Due 25 May 1994
Resolved 23 May 1994
Navigation
Issued 18 May 1994
Resolved
INSTALL LOW HYDRAULIC FLUID(OIL) ALARM(AUDIBLE AND VISIBLE) ON BRIDGE AND ENGINEROOM PRIOR TO NEXT U.S. VOYAGE.
Condition: Unknown
Due 23 May 1994
Resolved 23 May 1994
Unknown
Issued 5 October 1993
Resolved
VESSEL ARRIVED IN PORT ARTHUR WITH A 40 DEGREE WEST ERROR ON GYRO COMPASS. MASTER ADVISED OWNERS OF PROBLEMS BUT DID NOT NOTIFY COTP OF GYRO MALFUNCTION._x001C_
Condition: Unknown
Due 5 October 1993
Resolved 6 October 1993
Navigation
Issued 14 January 1992
Resolved
VESSEL UNDER 10,000 GROSS TONS HAD TWO RADARS INSTALLED. ONE WAS NOT OPERATIONAL. REQUIREMENT WAS ISSUED FOR VESSEL TO EITHER REPAIR OR REMOVE THE INOPERABLE RADAR PRIOR TO NEXT U.S. VOYAGE.
Condition: Unknown
Due 18 March 1992
Resolved 18 March 1992