07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 September 2023
Resolved
Fire extinguishers must be maintained iaw NFPA 10. Fire extinguishers in aft part of the vessels are mounted near the overhead. Portable fire extinguishers must be installed iaw NFPA 10. 46 CFR 177.960
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 September 2023
Resolution: Fire extinguishers relocated iaw NFPA 10
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 September 2023
Resolved
Waterlights must be meet the requirements of 46 CFR 161.010. Waterlight on vessel was inoperable at the time of inspection. Vsl must provide approved waterlight. 46 CFR 180.70(d)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 September 2023
Resolution: New battery installed in waterlight.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 September 2023
Resolved
Liferings must meet the requirements of 46 CFR 160.50. Vsl lifering did not have retro reflective material installed. Vsl must provide lifering which meets 46 CFR 160.50, 46 CFR 180.70(b))(1)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 September 2023
Resolution: Retro-reflective SOLAS tape provided.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 7 September 2023
Resolved
Machinery guards must be installed to protect accidental contact with rotating machinery. Vsl MDE does not have machinery guards installed on the forward operating end. Vsl must provide adequate machinery guards.46 CFR 177.960
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 September 2023
Resolution: Guard re-installed.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 10 March 2022
Resolved
Whenever damage or deterioration to hull plating or structual members that may affect the seaworthiness of a vessel is discovered, the cognizant OCMI may conduct an ISE. MI noted STBD aft bilge hull plate was deteriorated beyong limitations. Provide repair plan to MI on noted areas.
Action required: 705 - Other - as specified
Resolved 19 July 2023
Resolution: Affected areas of hull plating was cropped and renewed in kind.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 15 December 2020
Resolved
The vessel is overdue for its required annual inspection. All vessels must undergo an inspection for certification within the 3 months before or after each anniversary date.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 15 December 2020
Resolved 7 September 2023
Resolution: COI inspection conducted
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 3 June 2019
Resolved
Fire Extinguisher service expired.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 June 2019
Resolution: All fire ext. have been serviced by fire tech.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 3 June 2019
Resolved
Operation station extinguisher guage readying red/empty
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 June 2019
Resolution: New ext. installed.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 3 June 2019
Resolved
Aft portable extinguisher not in approved mount.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2019
Resolved 24 June 2019
Resolution: New approved mount installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 June 2019
Resolved
Provide CPR First AID cards missing
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2019
Resolved 24 June 2019
Resolution: CPR first aid card provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 June 2019
Resolved
22 deteriorated, limited to 54 Adults / 8 child (no more than 76 pax)
24 Jun 2019: New Life Jackets not properly marked.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2019
Resolved 26 June 2019
Resolution: All Life jacket markings are with in the regulation.
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 3 June 2019
Resolved
Provide drug consortium LTR. Out of date. Master had current card onboard but no enrollment LTR.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2019
Resolved 24 June 2019
Resolution: LTR Provided.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 3 June 2019
Resolved
Bilge alarm audible not working.
24 Jun 2019: Engine Room bilge alarm not working
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2019
Resolved 26 June 2019
Resolution: New bilge alarm installed.
10 - Safety of Navigation › N/A - No Subsystem › Life-saving signals
Issued 3 June 2019
Resolved
Orange smoke X3 out of date.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2019
Resolved 24 June 2019
Resolution: New flares provided
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 June 2019
Resolved
Expired Meds
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 June 2019
Resolution: Meds are new
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 3 June 2019
Resolved
Provide proper operation of fire dampner port and stbd.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 June 2019
Resolution: Cleaned and working properly
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 June 2019
Resolved
Fuel filter ouboard leaking.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 June 2019
Resolution: New gsk installed no leak
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 June 2019
Resolved
Steering panel cover not installed
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 June 2019
Resolution: Cover is secured with wire ties
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 3 June 2019
Resolved
Fixed fire pump missing belts due to pump damaged.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 June 2019
Resolution: New fire pump installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 June 2019
Resolved
Conduct underway trails. Fuse blowing when operating the fwd and bucket.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 June 2019
Resolution: Drill conducted SAT
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 June 2019
Resolved
Conduct SAT underway drills. 2 MOB drills conducted UNSAT.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 June 2019
Resolution: Conducted SAT drills
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 22 June 2018
Resolved
Expired meds (burn cream)
Action required: 705 - Other - as specified
Due 21 July 2018
Resolved 28 June 2018
Resolution: New burn cream date to exp. 2020
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 22 June 2018
Resolved
STBD nav light cracked and loose
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 July 2018
Resolved 25 July 2018
Resolution: New nav lights installed and tested SAT.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 22 June 2018
Resolved
18 sub standard lifejackets. each jacket ripped with little to no effort. limited to 58 adults and 10 child until new lifejackets are purchased and properly marked.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 July 2018
Resolved 25 July 2018
Resolution: All PFD are onboard and properly marked
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 22 June 2018
Resolved
Gov. spring broken in two places laying in bilge
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 July 2018
Resolved 25 July 2018
Resolution: New spring installed on govenor.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 22 June 2018
Resolved
Muffler mounting bracket broken
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 July 2018
Resolved 28 June 2018
Resolution: rewelded mounts and installed new hardware
Engineering › Fuel Oil Service System › Filter
Issued 22 June 2018
Resolved
F/O racor bowls leaking
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 June 2018
Resolution: Installed new racor filter housing
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 22 June 2018
Resolved
Rescue plat form securing strap missing.
Action required: 705 - Other - as specified
Due 21 July 2018
Resolved 25 July 2018
Resolution: New safety chains installed
Engineering › Steering Gear System › Ram
Issued 22 June 2018
Resolved
Ram mounting bracket broken with temp repair
Action required: 705 - Other - as specified
Due 21 July 2018
Resolved 25 July 2018
Resolution: Mount removed due to proper installation of steering ram.
Engineering › Steering Gear System › Ram
Issued 22 June 2018
Resolved
Steering ram through hull has a temp repair with sealant as the main structure. ram is loose at through hull.
Action required: 705 - Other - as specified
Due 21 July 2018
Resolved 25 July 2018
Resolution: Steering ram removed and installed new ram with new configuration without the suppirt mount as per manufacturer.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 22 June 2018
Resolved
Exhaust muffler outboard port side leaking exhaust into the engine room.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 June 2018
Resolution: Exhaust flange was not bolted to transom overboard due to wastage. 1 inch gap between flang face.
Engineering › Bilge Water Management System › Not Operational
Issued 31 May 2017
Resolved
Bilge Alarm with not sound.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 June 2017
Resolved 2 June 2017
Resolution: Turned on switch to make bilge alarm sound. Operator error.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 31 May 2017
Resolved
COD expired by 11 months
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 August 2017
Resolution: E-mailed COD
Lifesaving › Lifebuoys › Serviceable
Issued 31 May 2017
Resolved
Lifering needs retro tape.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 July 2017
Resolved 11 August 2017
Resolution: Added new retro tape
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 31 May 2017
Resolved
Needs battery
Action required: 705 - Other - as specified
Due 2 July 2017
Resolved 11 August 2017
Resolution: New battery installed
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 31 May 2017
Resolved
deteriorated line
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 July 2017
Resolved 11 August 2017
Resolution: New line attached
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 31 May 2017
Resolved
60 ft line deteriorated.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 July 2017
Resolved 11 August 2017
Resolution: Replaced line with new