JOJAC

Built
1991
Last inspected
30 December 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 30 December 2025
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

357953
Flag
UNITED STATES
Maury page id
psix-357953

Documentation record

Registered dimensions (L × B × D)55.3 ft × 15.0 ft × 4.3 ft
Registered tonnagegross 29 / net 23
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBREAUX BROS ENTERPRISES · LOREAUVILLE, LA, UNITED STATES · built 1991
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeBox
Hull configurationMonohull
Hailing portJACKSONVILLE, NC
Endorsements, as the file codes themcw_un, fi, rec
DocumentationValid · issued 20 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it29 - Simplified, Gross Ton
23 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 14 inspections, each with its date, unit and type; 37 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 14

30 December 2025 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8288315
23 April 2025 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8111496
8 October 2024 Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8015335
19 July 2023 Appeal · Internal Structural Exam · Drydock Exam · COI Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7763399
5 June 2023 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7706240
5 April 2023 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7663456
9 December 2021 Deficiency Check · Hull Examination
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7363724
15 December 2020 Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7112398
3 June 2019 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6702986
22 June 2018 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6451679
30 October 2017 Administrative Inspection
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6297327
31 May 2017 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6161324
3 June 2016 COI Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5882183
14 April 2016 Hull Examination
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5853519

Deficiency record · 37

07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 September 2023 Resolved
Fire extinguishers must be maintained iaw NFPA 10. Fire extinguishers in aft part of the vessels are mounted near the overhead. Portable fire extinguishers must be installed iaw NFPA 10. 46 CFR 177.960
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 September 2023
Resolution: Fire extinguishers relocated iaw NFPA 10
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 September 2023 Resolved
Waterlights must be meet the requirements of 46 CFR 161.010. Waterlight on vessel was inoperable at the time of inspection. Vsl must provide approved waterlight. 46 CFR 180.70(d)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 September 2023
Resolution: New battery installed in waterlight.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 September 2023 Resolved
Liferings must meet the requirements of 46 CFR 160.50. Vsl lifering did not have retro reflective material installed. Vsl must provide lifering which meets 46 CFR 160.50, 46 CFR 180.70(b))(1)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 September 2023
Resolution: Retro-reflective SOLAS tape provided.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 7 September 2023 Resolved
Machinery guards must be installed to protect accidental contact with rotating machinery. Vsl MDE does not have machinery guards installed on the forward operating end. Vsl must provide adequate machinery guards.46 CFR 177.960
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 September 2023
Resolution: Guard re-installed.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 10 March 2022 Resolved
Whenever damage or deterioration to hull plating or structual members that may affect the seaworthiness of a vessel is discovered, the cognizant OCMI may conduct an ISE. MI noted STBD aft bilge hull plate was deteriorated beyong limitations. Provide repair plan to MI on noted areas.
Action required: 705 - Other - as specified
Resolved 19 July 2023
Resolution: Affected areas of hull plating was cropped and renewed in kind.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 15 December 2020 Resolved
The vessel is overdue for its required annual inspection. All vessels must undergo an inspection for certification within the 3 months before or after each anniversary date.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 15 December 2020
Resolved 7 September 2023
Resolution: COI inspection conducted
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 3 June 2019 Resolved
Fire Extinguisher service expired.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 June 2019
Resolution: All fire ext. have been serviced by fire tech.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 3 June 2019 Resolved
Operation station extinguisher guage readying red/empty
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 June 2019
Resolution: New ext. installed.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 3 June 2019 Resolved
Aft portable extinguisher not in approved mount.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2019
Resolved 24 June 2019
Resolution: New approved mount installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 June 2019 Resolved
Provide CPR First AID cards missing
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2019
Resolved 24 June 2019
Resolution: CPR first aid card provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 June 2019 Resolved
22 deteriorated, limited to 54 Adults / 8 child (no more than 76 pax) 24 Jun 2019: New Life Jackets not properly marked.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2019
Resolved 26 June 2019
Resolution: All Life jacket markings are with in the regulation.
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 3 June 2019 Resolved
Provide drug consortium LTR. Out of date. Master had current card onboard but no enrollment LTR.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2019
Resolved 24 June 2019
Resolution: LTR Provided.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 3 June 2019 Resolved
Bilge alarm audible not working. 24 Jun 2019: Engine Room bilge alarm not working
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2019
Resolved 26 June 2019
Resolution: New bilge alarm installed.
10 - Safety of Navigation › N/A - No Subsystem › Life-saving signals
Issued 3 June 2019 Resolved
Orange smoke X3 out of date.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2019
Resolved 24 June 2019
Resolution: New flares provided
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 June 2019 Resolved
Expired Meds
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 June 2019
Resolution: Meds are new
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 3 June 2019 Resolved
Provide proper operation of fire dampner port and stbd.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 June 2019
Resolution: Cleaned and working properly
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 June 2019 Resolved
Fuel filter ouboard leaking.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 June 2019
Resolution: New gsk installed no leak
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 June 2019 Resolved
Steering panel cover not installed
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 June 2019
Resolution: Cover is secured with wire ties
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 3 June 2019 Resolved
Fixed fire pump missing belts due to pump damaged.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 June 2019
Resolution: New fire pump installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 June 2019 Resolved
Conduct underway trails. Fuse blowing when operating the fwd and bucket.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 June 2019
Resolution: Drill conducted SAT
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 June 2019 Resolved
Conduct SAT underway drills. 2 MOB drills conducted UNSAT.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 June 2019
Resolution: Conducted SAT drills
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 22 June 2018 Resolved
Expired meds (burn cream)
Action required: 705 - Other - as specified
Due 21 July 2018
Resolved 28 June 2018
Resolution: New burn cream date to exp. 2020
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 22 June 2018 Resolved
STBD nav light cracked and loose
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 July 2018
Resolved 25 July 2018
Resolution: New nav lights installed and tested SAT.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 22 June 2018 Resolved
18 sub standard lifejackets. each jacket ripped with little to no effort. limited to 58 adults and 10 child until new lifejackets are purchased and properly marked.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 July 2018
Resolved 25 July 2018
Resolution: All PFD are onboard and properly marked
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 22 June 2018 Resolved
Gov. spring broken in two places laying in bilge
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 July 2018
Resolved 25 July 2018
Resolution: New spring installed on govenor.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 22 June 2018 Resolved
Muffler mounting bracket broken
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 July 2018
Resolved 28 June 2018
Resolution: rewelded mounts and installed new hardware
Engineering › Fuel Oil Service System › Filter
Issued 22 June 2018 Resolved
F/O racor bowls leaking
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 June 2018
Resolution: Installed new racor filter housing
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 22 June 2018 Resolved
Rescue plat form securing strap missing.
Action required: 705 - Other - as specified
Due 21 July 2018
Resolved 25 July 2018
Resolution: New safety chains installed
Engineering › Steering Gear System › Ram
Issued 22 June 2018 Resolved
Ram mounting bracket broken with temp repair
Action required: 705 - Other - as specified
Due 21 July 2018
Resolved 25 July 2018
Resolution: Mount removed due to proper installation of steering ram.
Engineering › Steering Gear System › Ram
Issued 22 June 2018 Resolved
Steering ram through hull has a temp repair with sealant as the main structure. ram is loose at through hull.
Action required: 705 - Other - as specified
Due 21 July 2018
Resolved 25 July 2018
Resolution: Steering ram removed and installed new ram with new configuration without the suppirt mount as per manufacturer.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 22 June 2018 Resolved
Exhaust muffler outboard port side leaking exhaust into the engine room.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 June 2018
Resolution: Exhaust flange was not bolted to transom overboard due to wastage. 1 inch gap between flang face.
Engineering › Bilge Water Management System › Not Operational
Issued 31 May 2017 Resolved
Bilge Alarm with not sound.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 June 2017
Resolved 2 June 2017
Resolution: Turned on switch to make bilge alarm sound. Operator error.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 31 May 2017 Resolved
COD expired by 11 months
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 August 2017
Resolution: E-mailed COD
Lifesaving › Lifebuoys › Serviceable
Issued 31 May 2017 Resolved
Lifering needs retro tape.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 July 2017
Resolved 11 August 2017
Resolution: Added new retro tape
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 31 May 2017 Resolved
Needs battery
Action required: 705 - Other - as specified
Due 2 July 2017
Resolved 11 August 2017
Resolution: New battery installed
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 31 May 2017 Resolved
deteriorated line
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 July 2017
Resolved 11 August 2017
Resolution: New line attached
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 31 May 2017 Resolved
60 ft line deteriorated.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 July 2017
Resolved 11 August 2017
Resolution: Replaced line with new

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.