Records from 1990 to 2026. Most recent: inspection, 9 June 2026.
Inspection history · 68
9 June 2026
Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8395937
6 March 2026
Administrative Inspection · Damage Survey
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8331316
11 July 2025
Examination of Repairs · Damage Survey
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8183070
11 July 2025
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8202271
11 June 2025
Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8156977
18 September 2024
Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8004666
17 June 2024
Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7936541
9 May 2023
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7679324
18 October 2022
Examination of Repairs · Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7577166
7 April 2022
COI Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7425140
26 May 2021
Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7199893
26 March 2021
Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7161335
18 March 2021
Damage Survey
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7159478
19 January 2021
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7130225
14 July 2020
Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6990410
9 January 2020
Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6868022
27 June 2019
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6727315
16 July 2018
Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6481522
11 January 2018
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6336027
18 April 2017
COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6123135
18 December 2016
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6059724
18 December 2016
Damage Survey
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6059726
13 July 2016
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5936534
6 January 2016
Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5791847
13 July 2015
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5185640
10 January 2012
Drydock Exam · Internal Structural Exam · Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4222287
25 July 2011
Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4093453
11 January 2010
Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3662191
21 July 2009
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3541338
16 July 2008
Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3269890
17 January 2008
Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3132107
23 April 2007
COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2913411
20 July 2006
Re-Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2720029
3 February 2006
Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2578234
19 July 2005
Re-Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2431209
29 July 2004
Re-Inspection
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 2150420
13 January 2004
Hull Examination
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1969285
31 May 2003
Type not recorded
No type recorded · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1862089
10 December 2002
Deficiency Check
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1726969
18 July 2002
Deadweight Survey
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1648413
26 June 2002
Deficiency Check
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1637284
25 April 2002
MARPOL Annex V Examination · Administrative Inspection · COI Inspection · Hull Examination
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1609208
2 April 2001
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 109348
8 February 2001
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1440439
1 February 2001
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1440438
29 October 2000
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 172287
3 February 2000
COI Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1365568
12 February 1999
Hull Examination · Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1421630
20 October 1998
Damage Survey
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1384078
18 October 1998
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 135763
17 March 1998
Re-Inspection · MARPOL Annex V Examination · Examination of Repairs
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1110407
3 March 1998
Hull Examination · Damage Survey
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1110405
26 February 1998
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 98642
5 February 1997
COI Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1101061
17 December 1996
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1094808
12 March 1996
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 884558
22 February 1995
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1159001
5 December 1994
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1162616
15 November 1994
Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1175118
7 February 1994
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1161982
10 September 1993
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 185234
4 May 1993
Hull Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1147518
18 June 1992
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 958579
13 March 1992
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 952404
20 February 1992
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 952402
7 February 1991
Initial Certification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 931307
4 January 1991
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 931144
31 January 1990
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 934907
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 9 June 2026
Resolved
Provide a visual and audible to indicate a high water level in the port and starboard aft compartments (compartments with through hull fittings below the water-line) prior to carrying passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 June 2026
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 9 June 2026
Resolved
Provide a new hydrostatic release for the category 1 EPIRB prior to carrying passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 June 2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 June 2026
Resolved
Mark the 14 identified adult life jackets with new Type I retroreflective material (SOLAS tape).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2026
Resolved 22 June 2026
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 9 June 2026
Resolved
Provide an updated U.S. Coast Pilot [name withheld] List, Tide Tables. Can be extracts of local area in paper or downloaded electronic format.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2026
Resolved 22 June 2026
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 6 March 2026
Resolved
Whenever damage to hull or structural members that may affect the seaworthiness of a vessel is discovered or suspected, the cognizant OCMI may conduct an internal structural examination in any affected space. Vessel reported impacting a submerged vessel while transiting near Fleming Key at idle speed. Vessel shall be made available for inspection prior to carrying passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 March 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 July 2025
Resolved
Received report that the vessel's port propeller had spun off. Vessel is a catamaran and designed for port and starboard propulsion. Prove proper installation and operation of the port propulsion system prior to carrying passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 July 2025
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 11 June 2025
Resolved
Provide updated list of employees enrolled in a random drug and alcohol program.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2025
Resolved 30 June 2025
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 11 June 2025
Resolved
Provide non-expired alcohol swabs or other means to test employees for alcohol.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2025
Resolved 30 June 2025
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 June 2025
Resolved
Provide 2 additional fire buckets (3 total), label, and attach a suitable lanyard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2025
Resolved 30 June 2025
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 11 June 2025
Resolved
Seal the port throttle cable run wear it penetrates the transom.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2025
Resolved 30 June 2025
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 17 June 2024
Resolved
Provide a valid FCC Safety Radio Certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 July 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 June 2024
Resolved
Install battery box covers or other means to protect against falling objects on the port and starboard battery installations.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 July 2024
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 9 May 2023
Resolved
The hydrostatic release for the Cat 1 EPIRB is beyond two years from installation. Install new hydrostatic release and mark two year expiration date prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 May 2023
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 9 May 2023
Resolved
Crew training for emergencies has not been logged in the previous three months. Conduct and log crew training for their duties in flood, fire, and abandon ship emergencies.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 May 2023
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 9 May 2023
Resolved
Provide updated excerpts in paper or downloaded electronic form of the following nautical publications for the vessel's operating area:
-U.S. Coast Pilot
-Coast Guard Light List
-Tide Tables
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 May 2023
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 October 2022
Resolved
The Mast [name withheld] states it was installed in January 2010. Per CG/Industry guidance, stainless steel rigging needs to be replaced every 10 years. Either provide proof that the spreader wires were replaced more recently than October 2012 or replace the spreader wire in kind.
Action required: 705 - Other - as specified
Resolved 15 November 2022
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 18 October 2022
Resolved
Preventative Maintenance Plans (PMP) should contain a description of the vessel w/ rigging, an inventory of all rigging with replacement dates, and an inspection/maintenance schedule. Your PMP has the general description and inventory, but no inspection/maintenance schedule. Update your PMP with an inspection/maintenance schedule.
Action required: 705 - Other - as specified
Resolved 1 December 2022
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 7 April 2022
Resolved
Provide vessel's Sail Plan with the MSC approval stamp dated March 30, 2012.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 April 2022
Resolution: Received approved sail plan from MSC records.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 April 2022
Resolved
Provide most recent rigging inspection report.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 April 2022
Resolution: Rep provided rigging survey from Keys Rigging dated 10/06/21. Checked work items on the boat identified in survey. All work has been completed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 April 2022
Resolved
Ring life buoy is no longer international orange. Replace ring life buoy.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 April 2022
Resolution: New ring buoy with vessel name has been provided.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 7 April 2022
Resolved
Display or distribute a community service hot-line telephone number for crewmembers seeking assistance with drug and alcohol abuse.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 April 2022
Resolution: Hotline number has been posted in starboard hull work/storage space.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 7 April 2022
Resolved
Provide and document drug and alcohol use training for all crewmembers as part of the company's required Employee Assistance Program.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 April 2022
Resolution: 60 minutes of EAP training material has been provided to the crew in the company's slack channel. Company has documented training of all crew after they have reviewed the material.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 7 April 2022
Resolved
Provide valid Safety Radiotelephony Certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 April 2022
Resolution: FCC Safety Radio Cert provided.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 7 April 2022
Resolved
Provide current paper or electronic versions of the Coast Guard Light List and Coast Pilot.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 April 2022
Resolution: Electronic Coast Pilot and Light List has been downloaded to each Captain's phone.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 7 April 2022
Resolved
Attach starboard holding tank vent to through-hull fitting.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 April 2022
Resolution: Fitting attached.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 April 2022
Resolved
Raise aft port bilge suction approx 4" above bilge to prevent accidental sewage discharge and lower high level alarm float switch to the same plane.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 April 2022
Resolution: Bilge pump and alarm have been moved to discussed location and tested.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 April 2022
Resolved
Forward starboard high level alarm is weak and intermittent. Rewire or replace so alarm sounds constant when float switch is lifted.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 April 2022
Resolution: Rep cut back wiring and replaced float switch. Tested sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 April 2022
Resolved
Address loose wires in port battery compartment.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 April 2022
Resolution: Dead end wires ran from battery space to the head and were completely removed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 May 2021
Resolved
Replace flexible hose between fuel filter and primer pump with USCG Type A1, A2, B1, or B2 flexible hose. Two compressive force hose clamps must be used on each end.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2021
Resolved 11 August 2021
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 26 May 2021
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 June 2021
Resolved 22 September 2021
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 26 May 2021
Resolved
Provide NOAA EPIRB Registration issued to vessel's current owner.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 June 2021
Resolved 11 August 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 May 2021
Resolved
Provide inventory of all rigging components, including the age of the component, size, type of material, and manufacturer recommended replacement schedule.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 June 2021
Resolved 11 August 2021
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 18 March 2021
Resolved
Must complete an inspection of the hull out of the water in presence of a marine inspector prior to the carriage of passengers. On 3/19/21, vessel experienced a "bump and go", and possible damage to the port rudder is suspected.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 March 2021
Resolved 30 July 2021
Resolution: Resolved by Act. # 7161335
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 14 July 2020
Resolved
Vessel must conduct successfull man overboard drill in the prescence of a marine inspector prior to the carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 July 2020
Resolved 3 August 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 July 2020
Resolved
Vessel must provide adequate lifejackets for all persons authorized on the Certificate of Inspection prior to carriage of the full complement of passengers and crew. 07 lifejackets lacked the required retro reflective tape required and 01 lifejacket was condemned due to wear. Total persons onboard is reduced to 31 until such time that the lifejackets are repaired/replaced.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2020
Resolved 3 August 2020
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 14 July 2020
Resolved
Bilge/High Water alarm panel is located behind a non-transparent door. This makes the visual alarm indicators impossible to see. Ensure that visual indicators are visible from the operating station.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2020
Resolved 3 August 2020
Resolution: Inspection viewing porthole installed on panel door, making the visual alarm indicators visible.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 9 January 2020
Resolved
Submit repair proposal to USCG for approval to damaged interior Port hull in forward compartment. Hull damage was found centralized in one small area were first layer of plywood was split. Proposal shall include steps of repair and materials that will be used.
Action required: 705 - Other - as specified
Resolved 21 January 2020
Resolution: Approved and completed.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 9 January 2020
Resolved
Repair indicated area on STBD transom. Damage to FRP hull was found and core saturated with water.
Action required: 705 - Other - as specified
Resolved 21 January 2020
Resolution: Repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 January 2020
Resolved
Install approved aluminum fuel tanks on vessel, installation shall be in-accordance with regulations covered in 46 CFR Subpart "T" (46 CFR Part 182).
Action required: 705 - Other - as specified
Resolved 29 January 2020
Resolution: completed
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 January 2020
Resolved
Conduct underway sea trail under full sail as per approved sail plan with attending Marine Inspector prior to carrying passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 January 2020
Resolution: completed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 July 2019
Resolved
Submit plans for new fuel tanks. Portable tanks are only authorized for vessels with 12 or fewer passengers and up to 7 gallons.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2019
Resolved 12 August 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 July 2019
Resolved
Submit electrical drawing of inverter. All additions to the electrical system must be submitted to local OCMI prior to install.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2019
Resolved 12 August 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 July 2019
Resolved
All fuses must be of the cartridge type. Current fuses are the blade type.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2019
Resolved 29 January 2020
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 15 July 2019
Resolved
Line on the ring buoy is deteriorated. Replace with 60ft of buoyant, non kinking, dark color, synthetic line that is at least 5/16 inch diameter and resistant to UV light.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2019
Resolved 12 August 2019
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 July 2019
Resolved
Replace 5 gallon buckets with the required 2.5 gallon buckets with the appropriate length lanyard and marked fire bucket.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2019
Resolved 12 August 2019
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 15 July 2019
Resolved
Update emergency instruction list to be a better representation of what will happen for fire, heavy weather and man over board.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2019
Resolved 12 August 2019
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 15 July 2019
Resolved
Provide paper copies of up to date coast pilot, light list and tide tables of locations vessels transits.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2019
Resolved 12 August 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 15 July 2019
Resolved
Post sign stating, Documents available upon request for the COI and Stability letter.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 July 2019
Resolved 12 August 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 15 July 2019
Resolved
Provide updated drug consortium list.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2019
Resolved 12 August 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 July 2019
Resolved
Post donning placards for all types/versions of life jackets on board in a location.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2019
Resolved 12 August 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 July 2019
Resolved
Replace retro reflective tape on life jackets. Numerous life jackets reflective tape is no longer reflective.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2019
Resolved 12 August 2019
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 15 July 2019
Resolved
All aspirin in first aid kit is expired. Replace 100 tablets.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2019
Resolved 12 August 2019
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 16 July 2018
Resolved
Lights for the aft bilge alarms did not function
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 August 2018
Resolved 14 August 2018
Resolution: lights were repaired and are properly functioning
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 July 2018
Resolved
Vessel has no sail plan/rigging inspection regimen
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 August 2018
Resolved 14 August 2018
Resolution: rigging program submitted
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 16 July 2018
Resolved
Life float is severely damaged and needs replacing/repair. Vessel also has the option to reduce route to less than three miles to eliminate the requirement for the appliance.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 August 2018
Resolved 28 January 2019
Resolution: Vessel owner never responded to OCMI. Vessel route reduced to 3 miles.
Construction/Loadline › Hull › Hull Plating
Issued 11 January 2018
Resolved
Make repairs to crack in port hull.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 February 2018
Construction/Loadline › Hull › Bottom Plating
Issued 11 January 2018
Resolved
Crop and renew marked area in way of port head salt water feed through hull.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 February 2018
Construction/Loadline › Hull › Bottom Plating
Issued 11 January 2018
Resolved
Make repairs to starboard rudder tube.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 February 2018
Sail Rigging › Catamaran › Dolphin/Pelican Striker and Bridle Arrangement
Issued 18 December 2016
Resolved
Conduct permant repairs to structure, mast, rigging, and rails to the satisfaction of the attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 March 2017
Resolution: Satisfactory Sea Trial conducted
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 13 July 2016
Resolved
Maintain onboard full medical kit as required.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 July 2016
Resolved 13 July 2016
Resolution: O/O purchased new first aid kit
Construction/Loadline › Hull › Hull Plating
Issued 11 January 2016
Resolved
IDENTIFIED AREAS ON BOTH PORT AND STARBOARD BOWS THAT WERE WORN DOWN INTO FIBERGLASS. REPAIR AREAS. 46 CFR 176.600
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 February 2016
Resolution: AREAS WERE REPAIRED TO THE SATISFACTION OF THE RESIDENT MARINE INSPECTOR.
Construction/Loadline › Hull › Hull Plating
Issued 11 January 2016
Resolved
REPAIR AREAS IDENTIFIED DURING INSPECTION OF BOTH PORT AND STARBOARD HULLS. AREAS IDENTIFIED HAD WATER BLISTERS. 46 CFR 176.600
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 February 2016
Resolution: AREAS IDENTIFIED WERE SANDED DOWN AND REPAIRED. ALL SAT
Construction/Loadline › Hull › Hull Plating
Issued 11 January 2016
Resolved
PORT SIDE HULL INBOARD THRU HULL FITTING/DRAIN HAS DELAMINATION AROUND THE THRU HULL ENCOMPASSING 6" RADIUS. REPAIR IDENTIFIED AREA. 46 CFR 176.600
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 February 2016
Resolution: DELAMINATED AREA WAS REMOVED BY MECHANICAL MEANS ADN REPAIRED BACK TO ORIGINAL. ALL SAT
Construction/Loadline › Structures › Deck Plating
Issued 11 January 2016
Resolved
IDENTIFIED DECAYED WOOD IN OVERHEAD INSIDE PORT HULL LOCATED AT AFT CHAIN PLATE AND STANCHION ON MAIN DECK, AREA ENCOMPASSES APPROXIMATELY 1' SQUARE. REPAIR/REPLACE DECAYED WOOD. 46 CFR 176.600
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 February 2016
Resolution: REMOVED ALL DECAYED WOOD AND REPAIRED BACK TO ORIGINAL. ALL SAT
Construction/Loadline › Structures › Deck Plating
Issued 11 January 2016
Resolved
MAST STEP HAS AREA LOCATED TO THE PORTSTIDE ENCOMPASSING APPROXIMATELY 8" THAT HAS DELAMINATED. REPAIR AREA IDENTIFIED. 46 CFR 176.600
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 February 2016
Resolution: AREA WAS GROUND OUT AND REPAIRED BACK TO ORIGINAL. ALL SAT
Construction/Loadline › Structures › Deck Plating
Issued 11 January 2016
Resolved
IDENTIFIED AREA AMID SHIP STARBOARD SIDE WHERE STANCHION MOUNTS TO DECK. DECK IS DELAMINATED WITH THE STANCHION IS MOUNTED TO DECK AND CRACKED. REPAIR ARE INDENTIFIED. 46 CFR 176.600
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 February 2016
Resolution: AREA IDENTIFIED DURING INSPECTION WAS REMOVED THAT ENCOMPASSED APPROXIMATELY 1' SQUARE AREA. ALL REPAIRS WERE SAT.
Construction/Loadline › Structures › Deck Plating
Issued 11 January 2016
Resolved
LOCATION: STARBOARD SIDE AFT WHERE OUTBOARD ENGINE MOUNTS TO STERN. BRACKET/STRINGER IS FIBERGLASSED TO DECK. OUTBOARD STRINGER HAS DELAMINATED FROM DECK. REPAIR. 46 CFR 176.600
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 February 2016
Resolution: REPAIRED OUTBOARD STRINGER BY REGLASSING TO MAINE DECK. ALL SAT.
Construction/Loadline › Hull › Longitudinal Frame
Issued 11 January 2016
Resolved
LOCATION: AFT BATTERY COMPARTMENT STARBOARD SIDE HIS TWO LONGITUDINALS. ONE ON THE OUTBOARD SIDE NEEDS REPLACEMENT DUE TO SEVERE DETERIORATION (ANGEL HAIRING)AND CRACKED. INBOARD LONGITUDINAL NEEDS ANGEL HAIRING REMOVED AND WOOD PRESERVED. 46 CFR 176.600
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 February 2016
Resolution: BOTH LONGITUDINALS WERRE REPLACED AND WITH NEW. ALL SAT
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 11 January 2016
Resolved
BOTH PORT AND STARBOARD COMPARTMENTS WERE PORTABLE GAS TANKS SIT ARE FULL OF WATER. REMOVE WATER FOR COMPLETION OF HULL INSPECTION. 46 CFR 176.600
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 January 2016
Resolution: ALL WATER WAS REMOVED FROM BOTH PORT AND STARBOARD COMPARTMENTS AND COMPLETE INSPECTION OF COMPARTMENTS WAS CONDUCTED WITH SAT RESULTS.
Construction/Loadline › Structures › Superstructure
Issued 11 January 2016
Resolved
MAST STEP ON VESSEL SIDE IS SLEEVED AND PEDESTAL PEN HAS A LARGE AMOUNT PLAY. VERIFY TOLERANCES FOR PEN AND STEP. 46 CFR 176.600
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 February 2016
Resolution: AT THIS TIME THERE ARE NO TOLERANCES SET FOR THIS TYPE OF MAST STEP WITH PEN AND SLEEVE. CONVERSATIONS WITH MSC, TRAVELING INSP, SSP, CIVILAN RESIDENT EXPERT, & PLAN MANUFACTURE FINDS THAT THE VESSEL WILL UNSTEP THE MAST IN (04) YRS AND TAKE MEASUREMENTS.
Sail Rigging › Stays/Shrouds › Wires
Issued 11 January 2016
Resolved
PROVIDE COMPLETED RIGGING REPORT UPON COMPLETION OF REPORT.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 March 2016
Resolution: Recieved rigging report from O/O.
Communications › Radio Communications › EPIRB
Issued 13 July 2015
Resolved
Register EPIRB with current owner and vessel information prior to mounting new EPIRB.
Action required: 705 - Other - as specified
Resolved 31 July 2015
Resolution: Vessel provided current registration for newly purchased EPIRB.
Communications › Radio Communications › EPIRB
Issued 13 July 2015
Resolved
Mount EPIRB in float free location.
Due 13 August 2015
Resolved 31 July 2015
Resolution: Vessel mounted EPIRB in a float free location on the port quarter.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 13 July 2015
Resolved
Install fuel shutoff valves at tank connection of port and starboard fuel tanks.
Due 13 August 2015
Resolved 31 July 2015
Resolution: Vessel installed fuel shutoff valves at the port and starboard fuel tank connections.
Documentation › Certificates/Documents › FCC SSL
Issued 13 July 2015
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Due 13 August 2015
Resolved 31 July 2015
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Stability › Watertight Integrity › General
Issued 25 July 2011
Resolved
Fill in bulkhead pentrations in aft bulkhead leading wires to the outboard engines
Due 25 July 2011
Resolved 26 July 2011
Engineering › Bilge Water Management System › Interface Detector
Issued 25 July 2011
Resolved
Portside aft highwater level alarm must be audible and visual.
Due 25 July 2011
Resolved 26 July 2011
Accommodation/Occupational Safety › Cooking Systems › CNG System Requirements
Issued 25 July 2011
Resolved
Remove grill from vessel
Due 25 July 2011
Resolved 25 July 2011
Lifesaving › Lifefloat › Lifeline
Issued 12 January 2010
Resolved
Life line holder for life float is broken and line is entangled. Renew or repair life line holder and restow lifeline.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 January 2010
Resolution: Life line holder repaired and line properly stowed. All sat.
Accommodation/Occupational Safety › Ventilation › General
Issued 12 January 2010
Resolved
Lead acid batteries are installed in common area of accomodation spaces. Install non lead acid batteries (approved for installtion in accomodation interior spaces) or enclose batteries and vent to the exterior of the hull.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 12 February 2010
Resolved 10 February 2010
Resolution: New AGM batteries installed. All sat.
Stability › Watertight Integrity › General
Issued 11 January 2010
Resolved
Wire penetrations thru the hull are not watertight. Install approved watertight penetrations around all wire and cable hull penetrations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 February 2010
Resolved 18 January 2010
Resolution: Wire penetrations sealed. All sat.
Deck/Cargo › Towing › Tackle
Issued 11 January 2010
Resolved
Renew port side mast support cable, thru spreader bar. Cable is cracked and worn where it rides on the spreader bar eye bolt.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 February 2010
Resolved 18 January 2010
Resolution: New cable installed, new guide bolt installed and repair to spreader bar completed. All sat.
Lifesaving › Lifefloat › Retroreflective Material
Issued 16 July 2008
Resolved
Replace retroreflective tape on lifefloat as discussed.
Due 23 July 2008
Resolved 25 July 2008
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 16 July 2008
Resolved
Replace lifeline on lifebuoy.
Due 23 July 2008
Resolved 25 July 2008
Construction/Loadline › Structures › Superstructure
Issued 3 February 2006
Resolved
Provide report of rigging survey from qualified surveyor.
Due 3 March 2006
Resolved 20 July 2006
Resolution: Received rigging survey report
Operations/Management › Drills/Instruction › Not Conducted
Issued 29 July 2004
Resolved
Provide and maintain training log.
Action required: 705 - Other - as specified
Resolved 29 July 2004
Fire Fighting › Fire Bucket › Quantity
Issued 29 July 2004
Resolved
Provide an additional fire bucket.
Action required: 705 - Other - as specified
Resolved 29 July 2004
Lifesaving › Lifebuoys
Issued 25 April 2002
Resolved
Mount waterlight for Life Float. LEGACY COMPONENT DESC: Self-igniting Lights
Condition: Improper Installation
Due 25 May 2002
Resolved 17 May 2002
Resolution: Corrected.
Lifesaving › Lifebuoys
Issued 25 April 2002
Resolved
Provide and permanently mount weak link for Life Float and provide a 100 ft painter as discussed at time of inspection. LEGACY COMPONENT DESC: Stowage
Condition: Unknown
Due 25 May 2002
Resolved 17 May 2002
Resolution: Corrected
Lifesaving › Lifebuoys
Issued 25 April 2002
Resolved
Stencil vessel's name on 4 ft paddles.
Condition: Improper Installation
Due 25 May 2002
Resolved 17 May 2002
Resolution: Corrected
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 25 April 2002
Resolved
Provide Original Certificate of Documentation on board.
Due 25 May 2002
Resolved 25 May 2002
Resolution: Corrected
Documentation › Markings/Placards
Issued 25 April 2002
Resolved
Provide and post PFD donning placard.
Condition: Unknown
Due 25 May 2002
Resolved 17 May 2002
Resolution: Corrected.
Documentation › Markings/Placards
Issued 25 April 2002
Resolved
Provide and post FCC Emergency Broadcast placard on board near operating station.
Due 25 May 2002
Resolved 17 May 2002
Resolution: Corrected.
Documentation › Manuals/Policy Documentation
Issued 25 April 2002
Resolved
Post emergency instructions. LEGACY COMPONENT DESC: Emergency Instructions
Condition: Unknown
Due 25 May 2002
Resolved 17 May 2002
Resolution: Corrected.
Lifesaving › Lifejacket/PFD (Type I)
Issued 25 April 2002
Resolved
Provide adult sized PFDs for (36) passengers and (2) crew. The vessel is limited to carrying (17) adults and (4) children until corrected. LEGACY COMPONENT DESC: Quantity
Condition: Improper/Lack of Maintenance
Due 25 May 2002
Resolved 17 May 2002
Resolution: Corrected.
Engineering › Gasoline Engine (propulsion)
Issued 25 April 2002
Resolved
Service starboard engine to correct overheating. LEGACY COMPONENT DESC: Pump, Cooling Water (4 cycle)
Condition: Unknown
Due 25 May 2002
Resolved 17 May 2002
Resolution: Corrected.
Accommodation/Occupational Safety › Occupational Safety
Issued 25 April 2002
Resolved
Install courses or mesh with spaces not larger than 4 inches in accordance with 46 CFR 177.900. LEGACY COMPONENT DESC: Deck Rail
Condition: Improper Installation
Due 30 November 2002
Resolved 10 December 2002
Resolution: Corrected. Requirement extended after awaiting appeal until 30Nov02.
Lifesaving
Issued 8 February 2001
Resolved
Required to replace existing Buoyant Apparatus w/CG Approved Lifefloat due to material condition of the BA. Owner to notify upon arrival.
Condition: Unknown
Due 28 February 2001
Resolved 25 April 2002
Resolution: Corrected
Lifesaving
Issued 12 February 1999
Resolved
Update emergency procedures to reflect actual actions taken during emergency drills.
Condition: Unknown
Due 28 February 1999
Resolved 22 March 1999
Lifesaving
Issued 12 February 1999
Resolved
Replace weak link for BA.
Condition: Unknown
Due 28 February 1999
Resolved 22 March 1999
Lifesaving
Issued 12 February 1999
Resolved
Provide proper flare container.
Condition: Unknown
Due 28 February 1999
Resolved 22 March 1999
Documentation
Issued 12 February 1999
Resolved
Provide updated Certificate of Documentation.
Condition: Unknown
Due 28 February 1999
Resolved 22 March 1999
Lifesaving
Issued 12 February 1999
Resolved
Provide logbook. Ensure monthly EPIRB & visual inspectin of lifesaving equipment and quarterly manoverboard firedrills are logged.
Condition: Unknown
Due 12 February 1999
Resolved 22 March 1999
Lifesaving
Issued 5 December 1994
Resolved
REPLACE BUOYANT APPARATUS DUE TO DETERIORATION.
Condition: Unknown
Due 5 December 1994
Resolved 5 December 1994
Electrical
Issued 7 February 1994
Resolved
Remove hanging wires on lighting fixtures in port and stbd fwd compartments.
Condition: Unknown
Due 8 February 1994
Resolved 8 February 1994
Lifesaving
Issued 7 February 1994
Resolved
Attach lifefloat to vsl using painter and weaklink.
Condition: Unknown
Due 8 February 1994
Resolved 8 February 1994
Documentation
Issued 18 June 1992
Resolved
PROVIDE DOCUMENTATION OF PARTICIPATION IN A DRUG TESTING PROGRAM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 July 1992
Resolved 21 July 1992
Navigation
Issued 18 June 1992
Resolved
OBTAIN A CURRENT COPY OF THE U.S. NAUTICAL CHART WHICH COVERS THE AREA OF NORTH WILDWOOD AND OUT 20 MILES.
Condition: Unknown
Due 20 July 1992
Resolved 21 July 1992