Records from 1990 to 2011. Most recent: inspection, 24 February 2011.
Inspection history · 27
24 February 2011
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3951452
14 February 2011
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3942931
19 November 2010
Ballast Water Examination · PII Safety Exam · ISPS II Exam · Commercial Dive Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3884248
13 March 2010
Ballast Water Examination · NPV Safety Exam · ISM Exam · ISPS III Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3692348
1 May 2008
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3196277
1 February 2008
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3140065
24 August 2005
MARPOL Annex I Examination · Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2471564
23 August 2005
Type not recorded
No type recorded · Sector Astoria · USCG Northwest District (CGD-NW) · Activity 2472741
29 August 2004
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2180490
26 August 2004
ISPS II Exam · Ballast Water Examination · PII Safety Exam · MARPOL Annex I Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2175418
24 August 2004
Type not recorded
No type recorded · Sector Astoria · USCG Northwest District (CGD-NW) · Activity 2184973
29 October 2003
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1942330
8 April 2003
Re-Inspection · Ballast Water Examination
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1771563
2 April 2003
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1767113
18 November 2002
MARPOL Annex V Examination · Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1708328
29 April 2002
Administrative Inspection
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1610597
2 January 2002
Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1477342
11 October 2000
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 283035
17 August 1996
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 393971
27 March 1996
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 389455
14 February 1995
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 375292
30 September 1994
Uninspected Other
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1354953
29 September 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 63528
12 August 1993
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 360067
23 September 1992
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 353375
13 August 1991
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 449135
13 December 1990
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 340756
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 13 March 2010
Resolved
A-60 overhead in the engine room is missing two areas of insulation. One area over the main engine and the other near the sewage line.
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 19 November 2010
Resolution: CG Inspector witnessed satisfactory repair of the affected areas. Deficiency cleared by [name withheld], MSU Portland.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 13 March 2010
Resolved
Type III sewage tank is leaking from the bottom.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 19 November 2010
Resolution: CG Inspector witnessed repair along with satisfactory Class report attesting to the completed repairs. Def cleared by [name withheld], MSU Portland.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 1 February 2008
Resolved
Self-closing fire doors in the stairway are not functioning properly - latches are broken or missing, and fire doors are not closing. Issued deficiency under 74 SOLAS II-2, Regulation 47. 70a.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 May 2008
Resolution: Received class report from agent clearing deficiencies.
Engineering › Fuel Oil Service System › Filter
Issued 26 August 2004
Resolved
Prove proper operation of the inoperable FO purifier (#2) which is missing a motor to the satisfaction of class.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 August 2004
Resolution: Class report was obtained, and vessel re-inspected. FO purifier was operating satisfactorily.
Fire Fighting › Combustible Materials › Grounds
Issued 26 August 2004
No resolution recorded
Remove all excess oily residue from floors of engine & steering room spaces.
Action required: 17 - Rectify deficiencies prior to departure
Resolution: Vessel re-inspected and found to be free of excessive oil.
Fire Fighting › Means of Escape › Doorways
Issued 26 August 2004
Resolved
Change locking devices located on interior doors of main deck that lead to the main engine room and steering room to a type of locking device that can be operated from both sides of the door. Current arrangement prevents ingress into the spaces for emergency fire fighting.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 August 2005
Fire Fighting › Firemans Outfit › Quantity
Issued 26 August 2004
Resolved
Re-locate firefighting suits so that they are stored in two separate locations. Update fire plan to reflect the location of the suits.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 August 2005
Engineering › Diesel Engine (propulsion-direct drive)
Issued 8 April 2003
Resolved
Excessive lube oil leaks on main diesel engine. Obtain class report prior to departure. LEGACY COMPONENT DESC: Cylinder Head
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 April 2003
Resolution: Recieved class report attesting to repairs. Corrected
Engineering › Diesel Engine (propulsion-electric)
Issued 8 April 2003
Resolved
Excessive fuel leaking from #1 Generator fuel pump and collecting in 55 gal drum. LEGACY COMPONENT DESC: Pump, High Pressure (fuel injection)
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 April 2003
Resolution: Received class report attesting to repairs. Corrected
Construction/Loadline › Structures › Scupper
Issued 8 April 2003
Resolved
Stack scupper plugged. excess water leaking into engineroom.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 April 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 8 April 2003
Resolved
Two stanchions on accommodation ladder were broken and loose. LEGACY COMPONENT DESC: Deck Rail
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 April 2003
Deck/Cargo › Cargo Stowage
Issued 2 January 2002
Resolved
NO.6 Cargo hold hydraulic pump supply line wasted and leaking. Repair to the satisfaction of class. LEGACY COMPONENT DESC: Cargo Hatch Hydraulics
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 January 2002
Resolved 29 April 2002
Resolution: RCVD CLASS REPORT STATING THAT THE #6 CARGO HOLD HAS BEEN REPAIRED AND IN GOOD ORDER.
Fire Fighting
Issued 11 October 2000
Resolved
PROVIDE VERIFICATION THAT FIRE SUITS (INCLUDING PROTECTIVE HELMET) COMPLIESWITH THE REQUIREMENT OF SOLAS OR PROVIDE NEW SUITS. SOLAS CHPT I REG 11/ CHPT II-2 REG 17. ITEM TO BE CORRECTED TO THE SATISFACTION OF CLASS PRIOR TO NEXT U.S. PORT AFTER SAILING FOREIGN.
Condition: Unknown
Due 14 February 2001
Resolved 14 February 2001
Navigation
Issued 17 August 1996
Resolved
U.S. COAST PILOT NOT ON BOARD. CORRECTED PRIOR TO DEPARTURE FM BALMS._x001C_
Condition: Unknown
Due 22 August 1996
Resolved 22 August 1996
Lifesaving
Issued 17 August 1996
Resolved
SOLAS 74 III/7.1.3, AUTO-LAUNCH APPARATUS FOR BRIDGE WING LIFEBUOYS INOPERABLE. CORRECTED PRIOR TO DEPARTURE FM BALMS.
Condition: Unknown
Due 22 August 1996
Resolved 22 August 1996
Navigation
Issued 17 August 1996
Resolved
LIGHT LIST NOT ON BOARD. CORRECTED PRIOR TO DEPARTURE FM BALMS.
Condition: Unknown
Due 22 August 1996
Resolved 22 August 1996
Lifesaving
Issued 17 August 1996
Resolved
SOLAS 74 III/19, PORT & STBD EMBARKATION LADDERS WASTED/ROTTED. CORRECTED PRIOR TO DEPARTURE FM BALMS.
Condition: Unknown
Due 22 August 1996
Resolved 22 August 1996