← All vessels
THOR ALLIANCE
THOR ALLIANCE is a 1984 freight ship. The Coast Guard has recorded 34 inspections since 1984, most recently in August 2008, along with 23 deficiencies — 2 with no resolution recorded — and 11 operational controls.
Records from 1984 to 2008. Most recent: inspection, 17 August 2008.
- Built
- 1984
- Last inspected
- 17 August 2008
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 23 recorded · 2 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
8312174 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
HSBE
359132
Flag
GREECE
—
Maury page id
psix-359132
Inspections, by type
…with no type recorded25
…past their stated due date2
Years with a record
17 calendar years (1984–2008)
The 34 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it13950 - Convention (Subpart B), Net Ton
25074 - Convention (Subpart B), Gross Ton
40940 - Dead Weight, Ton
50150 - Displacement, Ton
25074 - Convention (Subpart B), Gross Ton
40940 - Dead Weight, Ton
50150 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 34
17 August 2008
MARPOL Annex V Examination · Ballast Water Examination · ISPS I Exam · MARPOL Annex I Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3294251
16 August 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3294254
1 April 2008
ISPS III Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3175352
1 April 2008
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3175633
27 March 2008
ISM Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3172025
22 March 2008
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3169310
30 October 2007
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3089742
30 October 2007
In-Service Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3089859
18 October 2007
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3082583
5 March 2006
ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2596185
1 March 2006
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2601330
24 January 2006
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2572243
8 June 2005
MARPOL Annex V Examination · ISPS II Exam · Ballast Water Examination · Deficiency Check · MARPOL Annex I Examination · PII Safety Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2382718
8 March 2003
Deficiency Check · Ballast Water Examination · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1754421
28 February 2003
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1751067
25 February 2003
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1754570
23 February 2003
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1752341
21 February 2003
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1747521
11 February 2003
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1779246
30 October 2000
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 283473
20 September 1999
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 432798
17 August 1997
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 406764
16 May 1997
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 403649
31 May 1996
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 391704
10 October 1995
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 383657
5 August 1993
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 646077
22 July 1993
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 646075
14 June 1993
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 358876
7 November 1991
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 346894
1 December 1990
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 340518
17 October 1988
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 326222
5 October 1987
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 318794
16 April 1986
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 308058
7 October 1984
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 298253
Deficiency record · 23
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 17 August 2008
No resolution recorded
Ships crew was unable to operate incinerator as designed.
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 17 August 2008
No resolution recorded
Vessel could not provide hydrostatic test date for bunkering lines.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 1 April 2008
Resolved
Port Side catwalk handrail adjacent to #2 cargo hold broken/fractured causing immediate safety hazard to crew.
Chief mate claimed handrail was broken during heavy seas on transit from New York to Boston.
Navigation › Collision/Grounding Avoidance › Radar
Issued 30 October 2007
Resolved
Master reported an inoperable primary radar. Radar must be repaired prior to departing port.
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 8 March 2003
Resolved
Vessels bunker lines static liquid pressure test has not been tested in accordance with 33CFR156.170. Vessel must provide proper documentation of static liquid pressure test prior to taking bunkers In U.S. waters. LEGACY COMPONENT DESC: Piping
Documentation › Logs/Records
Issued 8 March 2003
Resolved
Vessel can not provide records of static liquid pressure test of it's bunker lines in accordance with 33CFR155.820. LEGACY COMPONENT DESC: Transfer Equipment Test/Inspection Records
Navigation › Piloting/Steering
Issued 21 February 2003
Resolved
MANEUVERING FACTS SHEET MISSING WARNING STATEMENT.
33 CFR 164.35(g)7 LEGACY COMPONENT DESC: Maneuvering Information Fact Sheet
Documentation › Logs/Records
Issued 21 February 2003
Resolved
OIL RECORD BOOL ENTRIES MUST BE INTIALED
33CFR 151.25(h) LEGACY COMPONENT DESC: Oil Record Book
Documentation › Logs/Records
Issued 21 February 2003
Resolved
GARBAGE RECORD BOOK ENTRIES NOT PROPERLY DOCUMNETED
33 CFR 151.55 LEGACY COMPONENT DESC: Garbage Recordkeeping
Engineering › Diesel Engine (propulsion-direct drive) › Crankshaft
Issued 21 February 2003
Resolved
LOSS MOF ENGINE PROULSION CONTROL FROMBRIDGE, TELEGRAPH ON BRIDGE NOT FUNCTIONING PROPERLY.
SOLAS 74/78 II-1 REG 49/1
Lifesaving
Issued 30 October 2000
Resolved
VESSEL MUST PROVIDE DOCUMENTATION FOR THE PROPER SERVICING AND RETURN OF THE VESSELS 3 LIFERAFTS AND EPIRB. AS PER SOLAS 74/78 CH3 19.2.
Electrical
Issued 16 May 1997
Resolved
Properly repair the leak in the ship service diesel generator cooling line prior to return to a U. S. port. Currently a patch is placed over the leak. SOLAS 74 I/11
Engineering
Issued 31 May 1996
Resolved
NO MECHANICAL CLOSURES IN BUNKER STATION, F/O VENT SMALL DISCHARGE CONTAINMENT.
Lifesaving
Issued 31 May 1996
Resolved
SOLAS III/31.1.7: LIFE BOUYS FOR SELF ACTIVATING SMOKE MARKERS ON BRIDGE WINGS NOT 4kg.
Lifesaving
Issued 31 May 1996
Resolved
SOLAS III/38.6.2: NO WEAK LINKS IN PORT OR STBD LIFE RAFT SEA PAINTER LINES.
Fire Fighting
Issued 10 October 1995
Resolved
HAVE CLASS INSPECT ALL SUPPLY AND EXHAUST VENTS LEADING INTO THE ENGINE ROOM BEFORE DEPARTING SAN FRANCISCO BAY. THE FIRE DAMPERS DO NOT WORK PROPERLY.
Electrical
Issued 10 October 1995
Resolved
HAVE CLASS INSPECT THE PORT SIDE MAIN ELECTRICAL CONDUIT LINE LEADING INTO THE HOUSE HAD A CRACK ON THE JUNCTURE OF THE TWO, BEFORE DEPARTURE FROM SANFRANCISCO BAY.
Fire Fighting
Issued 10 October 1995
Resolved
REPAIR/REPLACE SEVEN FIRE HOSES 65MM (2.5IN) THAT HAVE HOLES AND ARE IN UNSATISFACTORY CONDITION, BEFORE NEXT U.S. PORT.
Navigation
Issued 14 June 1993
Resolved
The light list was a 1992 edition and not correct.
Navigation
Issued 14 June 1993
Resolved
The charts were not current. Chart #18649 (56th Ed, 04JUL92) was picked up in LOSMS and not corrected at all. Chart #18645 (22nd Ed, 04APR92) same as18649.
Navigation
Issued 14 June 1993
Resolved
The coast pilot was picked up in LOSMS. Not corrected at all.
Documentation
Issued 1 December 1990
Resolved
OIL TRANSFER PROCEDURES MISSING MEANS OF COMMUNICATIONS AND TOPPING OFF _x001C_ PROCEDURES AS REQUIRED BY 33CFR155.750
Documentation
Issued 7 October 1984
Resolved
THE SUPPLEMENT TO THE IOPP CERTIFICATE AS REQUIRED BY 33 CFR 151.19 WAS NOTAVAILABLE.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.