Records from 1991 to 2007. Most recent: inspection, 17 June 2007.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 12
17 June 2007
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2964276
13 June 2007
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2960871
23 January 2006
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 2572014
19 September 2003
Annual Inspection · Ballast Water Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1901443
14 November 2001
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 295533
29 December 1999
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 436021
7 February 1997
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 400244
13 September 1994
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 370502
5 May 1993
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 476254
29 November 1991
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 347263
23 March 1991
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 342609
27 January 1991
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 341596
Fire Fighting › Fire Main › Condition
Issued 17 June 2007
Resolved
Entire fire main pop has numerous pin holes (i.e. 10 pin holes in approximately 10m length alongside cargo hold #3)
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 June 2007
Resolution: Vessel replaced and tested firemain. Class attest to the repairs.
Fire Fighting › Fire Main › Condition
Issued 13 June 2007
Resolved
Fire main pipe along cargo hold #1 has 15 pin holes. Repair/replace to the satisfaction of class and attending Coast Guard Marine Inspector. 74 SOLAS 2004 Ed. II-2/Reg 14.2.1
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 June 2007
Resolution: Vessel replaced fire main and tested new piping. Class attested to repairs.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 13 June 2007
Resolved
Deckrails and bulwarks joints/seams correded and coming apart. Repair to the satisfaction of class. ICLL 66 Reg 25
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 4 May 2010
Resolution: To the satisfaction of attending Coast Guard Marine Inspector
Fire Fighting › Emergency Fire Pumps
Issued 19 September 2003
Resolved
Emergency fire pump could not provide any water pressure. The pump could not get suction. LEGACY COMPONENT DESC: Pressure
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 October 2003
Resolution: Recieved class report.
Accommodation/Occupational Safety
Issued 19 September 2003
Resolved
EEBD (Emergency Escape Breathing Device) empty condition in way of (1) lower level of engine room; (2) outside of steering gear flat and aft engine room exit.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 October 2003
Resolution: Recieved class report.
Fire Fighting › Combustible Materials
Issued 19 September 2003
Resolved
Improper stowage of oxidizers, corrossives and oil based lubricants in steering flat.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 October 2003
Resolution: Recieved class report.
Deck/Cargo › Cargo Refrigeration
Issued 19 September 2003
Resolved
Numerous soft patches on cargo reefer condensor piping in engine room.
Action required: 705 - Other - as specified
Due 23 November 2003
Resolved 3 October 2003
Resolution: Recieved class report.
Navigation
Issued 29 December 1999
Resolved
Required to provide permanent containment around vent for steering system hydraulic oil. To be corrected by next dry dock.
Condition: Unknown
Due 14 November 2001
Resolved 14 November 2001
Deck/Cargo
Issued 13 September 1994
Resolved
VESSEL DOES NOT HAVE CONTAINMENT AROUND LUBE OIL PIPING ON DECK.
Condition: Unknown
Due 11 February 1997
Resolved 11 February 1997
Navigation
Issued 13 September 1994
Resolved
VESSEL WAS MISSING B.A. CHART 1081(REQUIRED CHART FOR MSO LA/LB AOR)
Condition: Unknown
Due 14 September 1994
Resolved 14 September 1994
Navigation
Issued 27 January 1991
Resolved
A VIO OF 33 CFR 164.30 IN THAT THE VSL DID NOT HAVE O/B U.S. CHART 12304 ORTHEIR ACCEPTABLE FOREIGN EQUIVALENT WHICH WAS REQUIRED FOR THE VSL'S ROUTE FROM CAPE HENLOPEN TO PACKER AVENUE MARINE TERMINAL, PHILADELPHIA, PA._x001C_ _x001C_
Condition: Unknown
Due 27 January 1991
Resolved 27 January 1991