Records in 1991. Most recent: inspection, 6 August 1991.
A report is not offered for this hull: Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. Reports.
Inspection history · 4
6 August 1991
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 676171
13 March 1991
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1222739
11 March 1991
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 342336
11 March 1991
Certificate of Compliance
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 910080
Navigation
Issued 11 March 1991
Resolved
33CFR164.33(a) CHART OF AREA 11302 NOT ON BOARD._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 March 1991
Resolved 11 March 1991
Unknown
Issued 11 March 1991
Resolved
46CFR35.30-1(c) RADIO ROOM WARNING SIGN MISSING._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 March 1991
Resolved 11 March 1991
Documentation
Issued 11 March 1991
Resolved
33CFR155.750 VESSEL HAD NO OIL TRANSFER PROCEDURES ONBOARD._x001C_
Condition: Unknown
Due 11 March 1991
Resolved 11 March 1991
Electrical
Issued 11 March 1991
Resolved
REPAIR ELECTRICAL WIRING AND FITTINGS ON STARBOARD CARGO MANIFOLD (ONE QUICK CLOSING VALVE) AND ON #3&7 PORT BALLAST TANK VENT GAS DETECTION DEVICES._x001C_ _x001C_
Condition: Unknown
Due 15 March 1991
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 11 March 1991
Resolved
REMARK/REPLACE THE FADED CARGO DECK EMERGENCY SHUTDOWN I.D. TAGS._x001C_ 46CFR153.296_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 March 1991
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 11 March 1991
Resolved
REPAIR OR REPLACE THE INOPERATIVE OIL WATER SEPARATOR PUMP AND TEST SYSTEM. RETAIN ALL WASTE ON BOARD UNTIL COMPLETED. 33CFR155.370_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 March 1991
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 11 March 1991
Resolved
PROVIDE TWO ADDITIONAL FIREFIGHTING SUITS (4 REQUIRED, 2 ON BOARD)._x001C_ SOLAS CH. II-2, REG. 17-3.1.2_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 March 1991
Resolved 11 March 1991
Deck/Cargo
Issued 11 March 1991
Resolved
REPAIR OR REPLACE ALL (DETIORIATED) DOUBLE-BOTTOM/BALLAST TANK VENT FLAME SCREENS. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 March 1991
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 11 March 1991
Resolved
REPAIR OR REPLACE ALL (DETIORIATED) FUEL VENT FLAME SCREEN BRACKETS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 March 1991
Resolved 11 March 1991
Navigation
Issued 11 March 1991
Resolved
INSTALL A FIXED RECHARGE STORAGE TANK FOR THE HYDRAULIC STEERING SYSTEM._x001C_ SOLAS CH.II-1, REG. 29-12.3_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 May 1991
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past