Records from 1990 to 1996. Most recent: inspection, 10 September 1996.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Fire Fighting
Issued 27 December 1993
Resolved
VESSEL'S FIRE EXTINGUISHERS NOT INSPECTED SINCE AUGUST 1992._x001C_ _x001C_ 46 C.F.R. 91.25-20_x001C_ SOLAS CH II-2 REG 6.5
Condition: Unknown
Due 28 December 1993
Resolved 28 January 1994
Lifesaving
Issued 27 December 1993
Resolved
LIFEBOAT FOOD RATIONS HAVE EXPIRED SINCE 1984._x001C_ _x001C_ 46 C.F.R. 94-20-5_x001C_ SOLAS CH III REG 38.18
Condition: Unknown
Due 28 December 1993
Resolved 28 January 1994
Lifesaving
Issued 27 December 1993
Resolved
LIFEJACKETS ARE NOT EQUIPPED WITH LIGHTS OR WHISTLES._x001C_ _x001C_ 46 C.F.R. 94.42-1(b) & 46 C.F.R. 94.42-5_x001C_ SOLAS CH III REG 32.1.6 & CH III REG 32.3.1_x001C_
Condition: Unknown
Due 28 December 1993
Resolved 28 January 1994
Lifesaving
Issued 27 December 1993
Resolved
RING BUOY WATER LIGHTS WERE INOPERATIVE._x001C_ _x001C_ 46 C.F.R. 94.43-5_x001C_ SOLAS CH III REG 31.2
Condition: Unknown
Due 28 December 1993
Resolved 28 January 1994
Navigation
Issued 27 December 1993
Resolved
SHIP'S WHISTLE INOPERATIVE._x001C_ _x001C_ _x001C_ 72 COLREGS PART D RULE 33
Condition: Unknown
Due 28 December 1993
Resolved 28 January 1994
Accommodation/Occupational Safety
Issued 27 December 1993
Resolved
VESSEL HAS NO APPROVED MARINE SANITATION DEVICE ABOARD.
Condition: Unknown
Due 27 January 1994
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Accommodation/Occupational Safety
Issued 13 November 1990
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 18 May 2002
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 13 November 1990
Resolved
A VIOLATION OF 46 CFR 25.25-5 IN THAT NO PFDS WERE ONBOARD THE VESSEL FOR ACREW OF SEVEN._x001C_ PENALTY STATUE 46 USC 4106.
Condition: Unknown
Due 25 January 1994
Resolved 25 January 1994
Documentation
Issued 13 November 1990
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 25 January 1994
Resolved 25 January 1994
Engineering
Issued 13 November 1990
Resolved
A VIOLATION OF 33 CFR 155.420 (A)(1-3) IN THAT THE VESSEL DID NOT HAVE FIXED PIPING AS REQUIRED FOR VESSELS 100-400 GT FOR THE REMOVAL OF OILY WASTE. _x001C_ PENALTY STATUE 33 USC 1321 (j)(2)._x001C_
Condition: Unknown
Due 25 January 1994
Resolved 25 January 1994
Engineering
Issued 13 November 1990
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 25 January 1994
Resolved 25 January 1994
Fire Fighting
Issued 13 November 1990
Resolved
A VIOLATION OF 46 USC 4102 (A) IN THAT THE VESSEL'S PORTABLE FIRE EXTINGUISERS WERE NOT KEPT IN A CONDITION FOR IMMEDIATE AND EFFECTIVE USE. PENALTY STATUTE 46 USC 4102._x001C_
Condition: Unknown
Due 27 January 1994
Resolved 28 January 1994