Records from 1991 to 2023. Most recent: inspection, 9 August 2023.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 51
9 August 2023
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7770054
9 August 2023
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7789803
31 January 2023
Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7629456
4 February 2022
Drydock Exam · Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7390084
4 March 2021
Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7150003
23 January 2020
Deficiency Check · COI Inspection · Drydock Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6894730
2 May 2019
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6674766
27 February 2019
Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6633827
13 April 2018
Administrative Inspection · Annual Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6393563
12 April 2017
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6132526
29 September 2016
Initial Construction-Excluding Oversight
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6012469
29 April 2016
Annual Inspection · Hull Examination · DAPI Audit · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5886140
28 January 2016
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5810477
21 June 2012
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4351648
28 January 2010
COI Inspection · Hull Examination · Deficiency Check · DAPI Audit · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3671542
7 May 2009
Annual Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3469634
9 January 2008
Annual Inspection · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3127548
27 September 2007
Hull Examination · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3067491
18 January 2007
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2932611
30 October 2006
Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2810763
29 August 2006
Annual Inspection · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2762637
18 July 2005
Hull Examination · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2431128
12 February 2004
Annual Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2010258
27 May 2003
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1803145
13 February 2003
Hull Examination · Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1746612
12 February 2002
Re-Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1484306
12 May 2001
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1063994
26 February 2001
Re-Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1386992
13 March 2000
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1047397
10 February 2000
Hull Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1372945
6 October 1999
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 784185
7 May 1999
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1126703
20 April 1999
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1378670
12 March 1999
Re-Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1395156
13 February 1998
Re-Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1386202
16 May 1997
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1106391
14 April 1997
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1100126
7 March 1997
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1396676
14 February 1997
COI Inspection · MARPOL Annex V Examination · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1356092
29 July 1996
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1092950
6 June 1996
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1357642
8 May 1996
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1405910
8 March 1996
Re-Inspection · MARPOL Annex V Examination · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1374520
7 February 1996
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1454298
3 May 1995
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1457266
15 April 1995
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 136471
3 March 1995
Re-Inspection · MARPOL Annex V Examination · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1422477
1 March 1994
COI Inspection · MARPOL Annex V Examination · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1405502
4 March 1993
Re-Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 837672
18 March 1992
Re-Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 946317
8 March 1991
Initial Certification · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 917554
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 31 January 2023
Resolved
Life jackets must be marked with retro reflective material. Retro reflective materials on life jackets was worn out. Provide new retro reflective material for life jackets.
46 CFR 185.604(h)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 March 2023
Resolved 28 February 2023
Resolution: New retro tape provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 January 2023
Resolved
Machinery and equipment installed must be suitable for the vessel and its operation for the purpose intended. Power steering hose where fitting is connected is corroded. Provide new parts to eliminate corrosion.
46 CFR 182.100
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 March 2023
Resolved 28 February 2023
Resolution: New hose installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 January 2023
Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. Ventilation duct opening in engine rooms was stuck open when closure activated. Conduct maintenance to ensure vent closures close at all times when operated.
46 CFR 182.465(h)
Action required: 10 - Deficiency Rectified
Resolved 31 January 2023
Resolution: Vent closure operational.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 4 February 2022
Resolved
All vessels must have navigation lights that are in compliance with Navigation Rules. Stern light not operational. Provide operational stern nav light.
46 CFR 183.420
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 March 2022
Resolved 26 February 2022
Resolution: Stern light provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 February 2022
Resolved
Remote fuel shut off valves required to be marked. Old fuel shutoff placard for system that is no longer used on vessel remains. Remove unused fuel shutoff placard.
46 CFR 185.608
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 March 2022
Resolved 26 February 2022
Resolution: Old fuel signs removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 February 2022
Resolved
Vessel required to have interlock for blower switch. Vessel exhaust blower interlock not operational on vessel that has fuel tanks for gasoline. Blower switch must be of the type interlocked with the starting switch and the ignition switch so that the blowers are started before the engine starter motor circuit or the engine ignition is energized. Provide operational interlock.
46 CFR 182.460(e)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 March 2022
Resolved 26 February 2022
Resolution: Interlock provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 February 2022
Resolved
Protect passengers, crew, and vessel from electrical hazards including fire originating in electrical equipment. A maximum of four conductor terminals shall be permitted to be installed on a single battery stud. 6 conductors were installed on one battery stud. Reduce to four conductors on each stud.
46 CFR 183.200
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 March 2022
Resolved 26 February 2022
Resolution: Battery terminal with 4 conductors.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 4 February 2022
Resolved
The name of the vessel must be marked on each life float paddle. Life float paddles not marked with name.
Provide names on life float paddles.
46 CFR 185.604
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 March 2022
Resolved 26 February 2022
Resolution: Paddles marked.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 February 2022
Resolved
The number and identification of the items stowed inside and their sizes must be marked in clearly legible letters and numbers on each container for life jackets.
Overhead storage of life jackets not labeled with numbers, identification, or sizes. Provide marking for stowed life jackets.
46 CFR 185.604
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 March 2022
Resolved 26 February 2022
Resolution: Lifejacket storage marked.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 4 March 2021
Resolved
FCC Safety Certificate was expired (26JAN20). Provide valid FCC Safety Certificate for vessel.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 April 2021
Resolved 27 March 2021
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 4 March 2021
Resolved
Hydrostatic release for EPIRB was expired. Install new hydrostatic release to ensure installment is set to automatically float free and activate in accordance with regulations.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 April 2021
Resolved 4 March 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 March 2021
Resolved
Vessel's COI required 24 Adult Type I PFDs, during the inspection the vessel only had 23 Adult Type I PFDs. Vessel is limited to 21 passengers until they procure (01) Adult Type I PFD.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 April 2021
Resolved 27 March 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 March 2021
Resolved
First Aid Kit had expired medication during annual vessel inspection. Remove expired materials from vessel's first aid kit and resupply with updated resources iaw 46 CFR 160.041.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 April 2021
Resolved 27 March 2021
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 23 January 2020
Resolved
All six hand red flare distress signals on board were found to be expired. Replace expired distress signals per 46 CFR 180.68
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 February 2020
Resolved 27 January 2020
Resolution: Red flares supplied.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 23 January 2020
Resolved
The life float weak link did not have an identification tag. Replace weak link with of proper strength for the size od the life float per 46 CFR 180.137.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 February 2020
Resolved 21 February 2020
Resolution: Replacement weak link received and installed
Documentation › Markings/Placards › Lifejacket Placard
Issued 28 January 2010
Resolved
PROVIDE LIFEJACKET DONNING PLACARD FOR VARIOUS LIFEJACKETS
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 3 March 2010
Resolved 26 February 2010
Navigation › Piloting/Steering › Coast Guard Light List
Issued 28 January 2010
Resolved
UPDATE COAST PILOT AND LIGHT LIST
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 March 2010
Resolved 26 February 2010
Navigation › Piloting/Steering › Compass Deviation Table
Issued 28 January 2010
Resolved
PROVIDE COMPASS DEVIATION TABLE
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 March 2010
Resolved 26 February 2010
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 28 January 2010
Resolved
PROVIDE ALCO SENSOR TESTING DEVICES.
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 March 2010
Resolved 26 February 2010
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 29 August 2006
Resolved
Provide proof for operating EAP program.
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 September 2006
Resolved 20 October 2006
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 29 August 2006
Resolved
Provide information of last MIS submission.
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 September 2006
Resolved 20 October 2006
Documentation › Certificates/Documents › FCC SSL
Issued 29 August 2006
Resolved
Obtain current and valid FCC SSL
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 September 2006
Resolved 20 October 2006
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 29 August 2006
Resolved
Renew as original lifelines on lifebuoy
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 September 2006
Resolved 20 October 2006
Construction/Loadline › Hull › Hull Plating
Issued 29 August 2006
Resolved
Renew as original the scratches in the hull IWO the bow and the keel as needed
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 December 2006
Resolved 30 November 2006
Electrical › Electrical Distribution System (service)
Issued 12 February 2004
Resolved
Remove or properly repair dead-end wires located at operating station. LEGACY COMPONENT DESC: Wiring
Condition: Improper/Lack of Maintenance
Due 12 March 2004
Resolved 12 March 2004
Engineering › Electric Propulsion System
Issued 12 February 2004
Resolved
Missing interlock with ignition switch. Vessel is gasoline operated and must meet this requirement. LEGACY COMPONENT DESC: Interlock Circuitry
Condition: Improper/Lack of Maintenance
Due 12 March 2004
Resolved 12 March 2004
Fire Fighting › Fixed Fire Detection System
Issued 12 February 2004
Resolved
Missing Vapor detector. LEGACY COMPONENT DESC: Detector/Call Point Grouping
Condition: Placed in Improper Service
Due 12 March 2004
Resolved 12 March 2004
Navigation › Piloting/Steering
Issued 12 February 2004
Resolved
Provide current US Coast Pilot. LEGACY COMPONENT DESC: US Coast Pilot
Condition: Improper/Lack of Maintenance
Due 12 March 2004
Resolved 12 March 2004
Navigation › Collision/Grounding Avoidance
Issued 12 February 2004
Resolved
Provide all-around light. LEGACY COMPONENT DESC: Navigation Lights
Condition: Unknown
Due 12 March 2004
Resolved 12 March 2004
Operations/Management › Drug and Alcohol Testing
Issued 13 February 2003
Resolved
Provide employee acknowledgement of company drug plan IAW 46CFR Part 16. LEGACY COMPONENT DESC: Employee Coverage
Condition: Unknown
Due 27 February 2003
Resolved 30 April 2003
Engineering › Fuel Oil Service System
Issued 13 February 2003
Resolved
Remove or provide explosion proof intrinsically safe atmosphere for wiring located in fuel tanks space IAW 46CFR182.410. LEGACY COMPONENT DESC: Ventilation
Condition: Improper Installation
Due 27 February 2003
Resolved 30 April 2003
Engineering › Fuel Oil Service System › Hose
Issued 13 February 2003
Resolved
Lose fuel hose clamp.
Condition: Unknown
Due 13 February 2003
Resolved 13 February 2003
Electrical › Electrical Distribution System (service) › Wiring
Issued 13 February 2003
Resolved
Dead end wire located at operating station.
Condition: Unknown
Due 13 February 2003
Resolved 13 February 2003
Documentation › Certificates/Documents
Issued 13 February 2003
Resolved
Missing Safety Certificate. LEGACY COMPONENT DESC: FCC SSL
Condition: Unknown
Due 27 February 2003
Resolved 30 April 2003
Electrical
Issued 12 February 2002
Resolved
Grounding strap for stbd engine disconnected. LEGACY COMPONENT DESC: Grounding strap
Condition: Improper/Lack of Maintenance
Due 12 February 2002
Resolved 12 February 2002
Resolution: Grounding strap re-attached.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 12 February 2002
Resolved
Failed 5 adult CG approved lifejackets and 1 child CG approved lifejacket.
Condition: Unknown
Due 12 February 2002
Resolved 12 February 2002
Resolution: 5 adult CG approved and 1 CG approved lifejackets provided.
Lifesaving › Buoyant Apparatus
Issued 12 February 2002
Resolved
Water light OOC. LEGACY COMPONENT DESC: Water light
Condition: Unknown
Due 12 February 2002
Resolved 12 February 2002
Resolution: Battery was replaced and light tested SAT.
Electrical › Lighting (service)
Issued 12 February 2002
Resolved
Provide (1) portable light at operating station.
Condition: Unknown
Due 12 February 2002
Resolved 12 February 2002
Resolution: Light provided.
Engineering
Issued 10 February 2000
Resolved
Prove proper operation of cooling water discharge temperature gauge in accordance with 46CFR182.15-5(b).
Condition: Unknown
Due 13 March 2000
Resolved 13 March 2000
Documentation
Issued 7 May 1999
Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 7 May 1999
Resolved 7 May 1999
Engineering
Issued 7 May 1999
Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 7 May 1999
Resolved 7 May 1999
Fire Fighting
Issued 7 May 1999
Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 20 May 1999
Resolved 7 May 1999
Fire Fighting
Issued 12 March 1999
Resolved
Bottle for pre-engineered fixed fire fighting system corroded and unserviced. Renew and provide all other requirements as per 46 CFR 181.420.Or, as an alternative, provide system as per 46 CFR 181.400.
Condition: Unknown
Due 12 March 1999
Resolved 12 March 1999
Construction/Loadline
Issued 12 March 1999
Resolved
Starboard, mid-chamber failed alternative chamber inflation test. Properly repair and complete tests IAW MSO Honolulu Inspection Note #22 to the satisfaction of the attending Marine Inspector.
Condition: Unknown
Due 12 March 1999
Resolved 12 March 1999
Engineering
Issued 12 March 1999
Resolved
Permanently secure fuel tank space vent inside of console on port side.
Condition: Unknown
Due 12 March 1999
Resolved 12 March 1999
Documentation
Issued 12 March 1999
Resolved
Provide proof of FCC Operators Permit.
Condition: Unknown
Due 12 March 1999
Resolved 12 March 1999
Lifesaving
Issued 14 February 1997
Resolved
Provide an operable waterlight with an eighteen feet lanyard for the buoyant apparatus (BA).
Condition: Unknown
Due 14 February 1997
Resolved 14 February 1997
Engineering
Issued 14 February 1997
Resolved
Vent ducting holed. Permanently repair port and stbd vent ducting to fuel tank space.
Condition: Unknown
Due 14 February 1997
Resolved 14 February 1997
Documentation
Issued 14 February 1997
Resolved
Provide proof of the Employees' Assistance Program (EAP) and documentation of the supervisory 60-minute training in accordance with 46CFR16.
Condition: Unknown
Due 14 February 1997
Resolved 14 February 1997
Lifesaving
Issued 14 February 1997
Resolved
Mark all PFDs, ring buoy, buoyant apparatus, and EPIRB with the vessel's official number.
Condition: Unknown
Due 14 February 1997
Resolved 14 February 1997
Engineering
Issued 14 February 1997
Resolved
Renew port vent closure and prove proper operation of stbd and aft vent closures for the fuel tank space.
Condition: Unknown
Due 14 February 1997
Resolved 14 February 1997
Lifesaving
Issued 14 February 1997
Resolved
Permanently install the proper size weak ling for the buoyant apparatus (BA).
Condition: Unknown
Due 14 February 1997
Resolved 14 February 1997
Documentation
Issued 14 February 1997
Resolved
Provide a valid FCC Safety Radio Certificate.
Condition: Unknown
Due 14 February 1997
Resolved 14 February 1997
Engineering
Issued 14 February 1997
Resolved
In lieu of plastic straps, install double stainless steel hose clamps at each flexible hose connection in the fuel system.
Condition: Unknown
Due 14 February 1997
Resolved 14 February 1997
Engineering
Issued 14 February 1997
Resolved
Install an emergency fuel shutoff valve in each fuel supply line at the fuel tank connection, operable from outside the fuel tank space.
Condition: Unknown
Due 14 February 1997
Resolved 14 February 1997
Electrical
Issued 14 February 1997
Resolved
Properly deadend wiring and properly splice wiring under the helm console.
Condition: Unknown
Due 14 February 1997
Resolved 14 February 1997
Navigation
Issued 6 June 1996
Resolved
PROVIDE AND POST (IF PRACTICABLE) EMERGENCY BROADCAST PLACARD IAW _x001C_ IFR 46 CFR 185.406.
Condition: Unknown
Due 6 June 1996
Resolved 6 June 1996
Lifesaving
Issued 8 May 1996
Resolved
ISSUED 14 NEW "T" REQUIREMENTS. SEE CG-835 NEW "T" CHECKLIST W/CASE FILE OR DISPATCHER OUTER ISLAND FILE.
Condition: Unknown
Due 8 May 1996
Resolved 8 May 1996
Lifesaving
Issued 8 March 1996
Resolved
Provide reflective tape on one adult and one child PFD that are weathered and repair one child PFD with damaged outer covering.
Condition: Unknown
Due 8 March 1996
Resolved 8 March 1996
Engineering
Issued 8 March 1996
Resolved
Renew fuel tank space exhaust ducting.
Condition: Unknown
Due 8 March 1996
Resolved 8 March 1996
Construction/Loadline
Issued 8 March 1996
Resolved
Make proper repairs to bolt rope on port side stern, last 12 inches.
Condition: Unknown
Due 8 March 1996
Resolved 8 March 1996
Lifesaving
Issued 8 March 1996
Resolved
Renew reflective tape on buoyant apparatus.
Condition: Unknown
Due 8 March 1996
Resolved 8 March 1996
Lifesaving
Issued 8 March 1996
Resolved
Make buoyant apparatus pendants in hanks.
Condition: Unknown
Due 8 March 1996
Resolved 8 March 1996
Electrical
Issued 8 March 1996
Resolved
Provide emergency lighting.
Condition: Unknown
Due 8 March 1996
Resolved 8 March 1996
Deck/Cargo
Issued 8 March 1996
Resolved
Properly mouse anchor chains.
Condition: Unknown
Due 8 March 1996
Resolved 8 March 1996
Engineering
Issued 8 March 1996
Resolved
Provide fuel tank dimensions.
Condition: Unknown
Due 8 March 1996
Resolved 8 March 1996
Lifesaving
Issued 8 March 1996
Resolved
Freshen markings on buoyant apparatus.
Condition: Unknown
Due 8 March 1996
Resolved 8 March 1996
Documentation
Issued 8 March 1996
Resolved
Provide FCC safety certificate and FCC station license.
Condition: Unknown
Due 8 March 1996
Resolved 8 March 1996
Fire Fighting
Issued 8 March 1996
Resolved
Provide evidence of servicing of the fire fighting equipment.
Condition: Unknown
Due 8 March 1996
Resolved 8 March 1996
Lifesaving
Issued 8 March 1996
Resolved
Provide 6 smoke flares.
Condition: Unknown
Due 8 March 1996
Resolved 8 March 1996
Fire Fighting
Issued 3 March 1995
Resolved
PROVE PROPER OPERATION OF THE HALON SYSTEM, TO INCLUDE VENTS AND ALARMS.
Condition: Unknown
Due 3 March 1995
Resolved 3 March 1995
Fire Fighting
Issued 3 March 1995
Resolved
SERVICE OR RENEW ONE B2 FIRE EXTINGUISHER IN ACCORANCE WITH 46 CFR 180.25- 15(b).
Condition: Unknown
Due 3 March 1995
Resolved 3 March 1995
Fire Fighting
Issued 3 March 1995
Resolved
SERVICE ONE HALON BOTTLE.
Condition: Unknown
Due 3 March 1995
Resolved 3 March 1995
Lifesaving
Issued 3 March 1995
Resolved
INSTALL SEA PAINTER FOR BUOYANT APPARATUS IN ACCORDANCE WITH 46 CFR 180.20.
Condition: Unknown
Due 3 March 1995
Resolved 3 March 1995
Lifesaving
Issued 3 March 1995
Resolved
STENCIL LIFE PRESERVERS STORAGE IN ACCORDANCE WITH 46 CFR 180.25-15(b).
Condition: Unknown
Due 3 March 1995
Resolved 3 March 1995
Fire Fighting
Issued 3 March 1995
Resolved
REPAIR OR RENEW VENT CLOSURES FOR FUEL TANK COMPARTMENT.
Condition: Unknown
Due 3 March 1995
Resolved 3 March 1995
Engineering
Issued 8 March 1991
Resolved
PROVIDE EMERGENCY FUEL SHUTOFF VALVES WHICH ARE OPERABLE FROM THE MAIN DECK.
Condition: Unknown
Due 8 March 1991
Resolved 8 March 1991
Documentation
Issued 8 March 1991
Resolved
PROVIDE A COPY OF FCC FORM 824 TO MSO HONOLULU (A TEMPORARY FCC CERTIFICATENOW ON BOARD).
Condition: Unknown
Due 8 March 1991
Resolved 8 March 1991
Engineering
Issued 8 March 1991
Resolved
FUEL LINES SHALL BE REPLACE WITH COPPER TUBING IN ACCORDANCE WITH 46 CFR 182.15.40(A).
Condition: Unknown
Due 8 March 1991
Resolved 8 March 1991
Engineering
Issued 8 March 1991
Resolved
PROVIDE A FUEL TANK FILL PIPE SO THAT OVERFLOW OF LIQUID OR VAPOR CANNOT ESCAPE TO THE INSIDE OF THE VESSEL.
Condition: Unknown
Due 8 March 1991
Resolved 8 March 1991
Engineering
Issued 8 March 1991
Resolved
SEAL DECK PENETRATION ABOVE THE FUEL TANK SO AS TO MAKE THAT PORTION OF DECK VAPORTIGHT.
Condition: Unknown
Due 8 March 1991
Resolved 8 March 1991
Engineering
Issued 8 March 1991
Resolved
PROVIDE A VENTILATION SYSTEM AND A FIXED FIRE FIGHTING SYSTEM FOR GASOLINE FUEL COMPARTMENT. THIS FUEL TANK IS NOT TO BE USED UNTIL IT IS SATISFACTORILY INSPECTED BY A USCG MARINE INSPECTOR.
Condition: Unknown
Due 8 March 1991
Resolved 8 March 1991
Lifesaving
Issued 8 March 1991
Resolved
PROVIDE A WEAK LINK FOR VESSEL'S BUOYANT APPARATUS.
Condition: Unknown
Due 8 March 1991
Resolved 8 March 1991
Navigation
Issued 8 March 1991
Resolved
PROVIDE A MAGNETIC COMPASS FOR VESSEL.
Condition: Unknown
Due 8 March 1991
Resolved 8 March 1991
Engineering
Issued 8 March 1991
Resolved
PROVIDE DUCTING FOR THE FUEL TANK COMPARTMENT SUPPLY VENTS IN ACCORDANCE WITH 46 CFR 182.15-45(f)-(h).
Condition: Unknown
Due 8 March 1991
Resolved 8 March 1991
Engineering
Issued 8 March 1991
Resolved
REROUTE FUEL TANK COMPARTMENT EXHAUST VENTILATION DUCT WHERE THE INTAKE ENDIS LEAD AS DIRECTLY AS POSSIBLE TO THE LOWEST PART OF THE COMPARTMENT.
Condition: Unknown
Due 8 March 1991
Resolved 8 March 1991
Engineering
Issued 8 March 1991
Resolved
THE DISCHARGE END OF THE FUEL TANK VENT PIPE SHALL TERMINATE ON THE HULL EXTERIOR IN ACCORDANCE WITH 46 CFR 182.15-25(C)._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 March 1991
Resolved 8 March 1991