Records from 2016 to 2023. Most recent: inspection, 9 August 2023.
Inspection history · 13
9 August 2023
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7770054
9 August 2023
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7789803
31 January 2023
Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7629456
4 February 2022
Drydock Exam · Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7390084
4 March 2021
Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7150003
23 January 2020
Deficiency Check · COI Inspection · Drydock Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6894730
2 May 2019
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6674766
27 February 2019
Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6633827
13 April 2018
Administrative Inspection · Annual Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6393563
12 April 2017
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6132526
29 September 2016
Initial Construction-Excluding Oversight
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6012469
29 April 2016
Annual Inspection · Hull Examination · DAPI Audit · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5886140
28 January 2016
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5810477
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 31 January 2023
Resolved
Life jackets must be marked with retro reflective material. Retro reflective materials on life jackets was worn out. Provide new retro reflective material for life jackets.
46 CFR 185.604(h)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 March 2023
Resolved 28 February 2023
Resolution: New retro tape provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 January 2023
Resolved
Machinery and equipment installed must be suitable for the vessel and its operation for the purpose intended. Power steering hose where fitting is connected is corroded. Provide new parts to eliminate corrosion.
46 CFR 182.100
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 March 2023
Resolved 28 February 2023
Resolution: New hose installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 January 2023
Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. Ventilation duct opening in engine rooms was stuck open when closure activated. Conduct maintenance to ensure vent closures close at all times when operated.
46 CFR 182.465(h)
Action required: 10 - Deficiency Rectified
Resolved 31 January 2023
Resolution: Vent closure operational.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 4 February 2022
Resolved
All vessels must have navigation lights that are in compliance with Navigation Rules. Stern light not operational. Provide operational stern nav light.
46 CFR 183.420
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 March 2022
Resolved 26 February 2022
Resolution: Stern light provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 February 2022
Resolved
Remote fuel shut off valves required to be marked. Old fuel shutoff placard for system that is no longer used on vessel remains. Remove unused fuel shutoff placard.
46 CFR 185.608
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 March 2022
Resolved 26 February 2022
Resolution: Old fuel signs removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 February 2022
Resolved
Vessel required to have interlock for blower switch. Vessel exhaust blower interlock not operational on vessel that has fuel tanks for gasoline. Blower switch must be of the type interlocked with the starting switch and the ignition switch so that the blowers are started before the engine starter motor circuit or the engine ignition is energized. Provide operational interlock.
46 CFR 182.460(e)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 March 2022
Resolved 26 February 2022
Resolution: Interlock provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 February 2022
Resolved
Protect passengers, crew, and vessel from electrical hazards including fire originating in electrical equipment. A maximum of four conductor terminals shall be permitted to be installed on a single battery stud. 6 conductors were installed on one battery stud. Reduce to four conductors on each stud.
46 CFR 183.200
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 March 2022
Resolved 26 February 2022
Resolution: Battery terminal with 4 conductors.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 4 February 2022
Resolved
The name of the vessel must be marked on each life float paddle. Life float paddles not marked with name.
Provide names on life float paddles.
46 CFR 185.604
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 March 2022
Resolved 26 February 2022
Resolution: Paddles marked.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 February 2022
Resolved
The number and identification of the items stowed inside and their sizes must be marked in clearly legible letters and numbers on each container for life jackets.
Overhead storage of life jackets not labeled with numbers, identification, or sizes. Provide marking for stowed life jackets.
46 CFR 185.604
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 March 2022
Resolved 26 February 2022
Resolution: Lifejacket storage marked.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 4 March 2021
Resolved
FCC Safety Certificate was expired (26JAN20). Provide valid FCC Safety Certificate for vessel.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 April 2021
Resolved 27 March 2021
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 4 March 2021
Resolved
Hydrostatic release for EPIRB was expired. Install new hydrostatic release to ensure installment is set to automatically float free and activate in accordance with regulations.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 April 2021
Resolved 4 March 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 March 2021
Resolved
Vessel's COI required 24 Adult Type I PFDs, during the inspection the vessel only had 23 Adult Type I PFDs. Vessel is limited to 21 passengers until they procure (01) Adult Type I PFD.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 April 2021
Resolved 27 March 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 March 2021
Resolved
First Aid Kit had expired medication during annual vessel inspection. Remove expired materials from vessel's first aid kit and resupply with updated resources iaw 46 CFR 160.041.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 April 2021
Resolved 27 March 2021
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 23 January 2020
Resolved
All six hand red flare distress signals on board were found to be expired. Replace expired distress signals per 46 CFR 180.68
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 February 2020
Resolved 27 January 2020
Resolution: Red flares supplied.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 23 January 2020
Resolved
The life float weak link did not have an identification tag. Replace weak link with of proper strength for the size od the life float per 46 CFR 180.137.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 February 2020
Resolved 21 February 2020
Resolution: Replacement weak link received and installed