Records from 2016 to 2025. Most recent: inspection, 2 September 2025.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 2 September 2025
No resolution recorded
Exhaust gas must not leak from the piping or any connections. Exhaust leaking from generator into engine room.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 2 September 2025
Resolved
Each collision bulkhead required by § 179.210, must be watertight. Collision bulkhead was found holed.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 January 2026
Resolution: Completed necessary repairs to make collision bulkhead watertight.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 September 2025
Resolved
"All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. The following maintenance items were identified as a non-conformities:
- Starboard engine alternator belt loose and frayed
- Starboard engine reduction hoses chaffed"
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 August 2026
Resolution: Belts replaced
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 2 September 2025
Resolved
At each initial and subsequent inspection for certification, the marine inspector shall view the vessel afloat and shall conduct the following tests and inspections of the hull structure and its appurtenances: Examine all weathertight closures above the weather deck. Forward and center bridge windows leaked when water was applied. Repair seal to satisfaction of marine inspector.
Old T - 46CFR176.25-5
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 23 February 2026
Resolution: Replace windows on bridge and well as accommodation areas of vessel. Professional installed windows on bridge. Workmanship on accommodation spaces will have to be reviewed after time in service.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 2 September 2025
Resolved
The person in command of a documented vessel must have on board that vessel the original Certificate of Documentation currently in effect for that vessel. Original COD is not on vessel. COD onboard expired in July 2025. Current COD was applied for on August 28, 2025.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 August 2026
Resolution: Reissued def due to calendar year.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 2 September 2025
Resolved
At each inspection for certification the marine inspector shall examime the bilges and other spaces to see that there is no accumulation of oil or other matter which might create a fire hazard. MI observed diesel fuel in the metal cup on the fuel filter for the generator.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 August 2026
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 2 September 2025
No resolution recorded
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessel's stability letter, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 25 millimeters (1 inch) numbers and letters at the entranceway to that deck. Aft entranceway to second deck missing sign for maximim umber of passengers.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 October 2025 — due date passed with no resolution recorded
09 - Working and Living Conditions › 091 - Living Conditions › Dirty, parasites
Issued 2 September 2025
Resolved
At each inspection for certification and at every other inspection, quarters, toilet and washing spaces, galleys, serving pantries, lockers, and similar spaces may be examined to determine if they are serviceable and in sanitary condition. MIs observed live and dead roaches in several compartments of the ship. Owner/operator must exterminate infestation with an effective method.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 October 2025
Resolved 26 January 2026
Resolution: At the time the vessel when back in the water, there were no signs of infestation. Utilized foggers and bait traps.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 2 September 2025
Resolved
No marine employer may engage or employ any individual to serve as a crewmember unless the individual passes a chemical test for dangerous drugs for that employer. Captain was not listed as a member of the vessel' s drug testing program.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2025
Resolved 20 August 2026
Resolution: Captain and crewmembers were enrolled in consortium.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 2 September 2025
Resolved
Each hatch exposed to the wearther must be watertight. The hatch into the forpeak was not properly sealing and water was entering the space. MI observed knife edge wasted and seal compressed in several areas.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 October 2025
Resolved 26 January 2026
Resolution: Knife edge and deck around hatch replaced.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 2 September 2025
Resolved
A battery charger intended for connection to a commercial supply voltage shall employ a transformer of the isolating type. An ammeter that is readily visible shall be included in the battery charger circuit. Two chargers installed for two ship's service battery banks had no ammeters installed in the circuits being charged.
46 CFR 183.05-20(f)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 October 2025
Resolved 20 August 2026
Resolution: installed.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 2 September 2025
Resolved
Except as noted in paragraph (c) of this section, stations in the maritime service must be licensed by the FCC either individually or by fleet. FCC Station License in not on vessel
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2025
Resolved 20 August 2026
Resolution: Copy of FCC Station License was on vessel.
01 - Certificates & Documentation › 013 - Documents › Garbage record book
Issued 2 September 2025
No resolution recorded
The master or person in charge of a ship, including a drilling rig or platform, to which this section applies shall ensure that one or more placards meeting the requirements of this section are displayed in prominent locations and in sufficient numbers so that they can be read by the crew and passengers. These locations must be readily accessible to the intended reader and may include embarkation points, food service facilities, garbage handling spaces, living spaces, and common areas on deck. Garbage plaquard is missing.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 October 2025 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 September 2025
Resolved
Fill pipes and sounding pipes must run as directly as possible, preferably in a straight line, from the deck connection to the top of the tank. Such pipes must terminate on the weather deck and must be fitted with shutoff valves, watertight deck plates, or screw caps, suitably marked for identification. Fuel fill not labeled as required.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 October 2025
Resolved 20 August 2026
09 - Working and Living Conditions › 091 - Living Conditions › Ventilation (Accommodation)
Issued 2 September 2025
Resolved
Each potable water tank shall be provided with a means of drainage and, if it is equipped with a manhole, overflow, vent, or a device for measuring depth of water, provision shall be made to prevent entrance into the tank of any contaminating substance. Water fill is missing fill cap.
21 CFR 1250.82(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2025
Resolved 20 August 2026
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 2 September 2025
Resolved
Installations and equipment shall be made reasonably reasonably safe from electrical shock of personnel. MI's found open light receptacles in the overhead spaces of holds #2 and #3 below deck.
Old T - 46 CFR 183.01-5(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2025
Resolved 20 August 2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 September 2025
Resolved
Each ring life buoy must be of an approved type, constructed in accordance with subpart 160.050 of this chapter. Two of the new life rings were not approved under 160.050. The SOLAS tape on the ring was also not approved. Replace ring life buoy with approved type.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 October 2025
Resolved 20 August 2026
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 2 September 2025
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. Concrete patch was found in engine room next to starboard engine sea suction. Must complete permanent repair at next drydock.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 26 January 2026
Resolution: Concrete patches removed and hull plate replaced in areas of raw water strainers.
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 2 September 2025
Resolved
At each inspection for certification and at every other inspection, quarters, toilet and washing spaces, galleys, serving pantries, lockers, and similar spaces may be examined to determine if they are serviceable and in sanitary condition. MI observed that the PVC sink drain in the prep area was not properly connected to the drain hose causing water to leak onto the base of the cabinet when the water was running.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2025
Resolved 26 January 2026
Resolution: sink drain correctly in stalled.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 2 September 2025
Resolved
A vessel must comply with ...47 CFR part 80.
When using DSC techniques...ship stations must use maritime mobile service identities (MMSI) assigned by the Commission or its designees.
MMSI was not entered into DSC radio.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 September 2025
Resolved 20 August 2026
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 August 2025
Resolved
The construction and arrangement of a vessel must allow for safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. Passengers on board the vessel observed water intrusion from the main cabin overhead subsequently running down the bulkheads during a heavy rain event. Serving trays were being used to collect the water and dump it overboard. Owner/operator must identify and repair the location of the leak to prevent further water intrusion to the satisfaction of the attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 August 2025
Resolved 26 January 2026
Resolution: Source of leak was determined to be from multiple areas including improberly installed bridge windows and wasted stairs which allowed water to enter vessel. Repairs completed to the satisfaction of Marine Inspector.
09 - Working and Living Conditions › 091 - Living Conditions › Dirty, parasites
Issued 15 August 2025
Resolved
At each inspection for certification and at every other inspection, quarters, toilet and washing spaces, galleys, serving pantries, lockers, and similar spaces may be examined to determine if they are serviceable and in sanitary condition. Passengers on board the vessel observed roaches in the area where the food was being prepared and staged. Owner/operator must exterminate infestation with an effective method.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 August 2025
Resolved 26 January 2026
Resolution: No evidence of infestation on this date. Owner used fogger and bait traps.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 27 June 2025
Resolved
Each pressure type wire connector and lug must meet UL 486A (incorporated by reference; see 46 CFR 175.600) or other standard specified by the Commandant. The use of twist-on type wire nuts is permitted under the following conditions: The connections must be made within an enclosure and the insulated cap of the connector must be secured to prevent loosening due to vibration. Twist-on type wire nuts found installed over bar sink without an enclosure.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2025
Resolved 10 July 2025
Resolution: Twist nuts removed and properly spliced.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 June 2025
Resolved
A vessel must be operated in accordance with applicable
laws and regulations in such a manner as to afford
adequate precaution against hazards that might endanger
the vessel and the persons to be transported.
The below deficiencies provide objective evidence that the vessel is substandard and not proactively managing technical and operational requirements. Vessel must make correction to the below deficiencies and get underway with marine inspectors to perform satisfactory operational test and drills prior to any movement.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 9 July 2025
Resolved 15 July 2025
Resolution: Got vessel underway and conducted satisfactory drills.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 26 June 2025
Resolved
Electrical equipment and circuits which are a necessary part of any system vital to the safe navigation of the vessel will be given special consideration and shall be subject to certain additional requirements as determined by the Officer in Charge, Marine Inspections. Generator utilized to power fire pump / bilge pump inoperable. 46 CFR 183.01-10(a)
Action required: 30 - Ship detained
Due 9 July 2025
Resolved 15 July 2025
Resolution: Generator repaired and properly working.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 26 June 2025
Resolved
A power-driven fire pump shall be installed on each mechanically propelled "L" vessel. Installed fire pump suction valve is seized closed and not able to open in the vent of emergency.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 9 July 2025
Resolved 10 July 2025
Resolution: Valve operation repaired.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 26 June 2025
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts. Paper navigation charts for vessel was outdated by two years.
Condition: Invalid
Action required: 30 - Ship detained
Due 9 July 2025
Resolved 15 July 2025
Resolution: Paper charts for AOR purchashed.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 26 June 2025
Resolved
On or before March 11, 1999, an existing vessel must comply with the bilge high level alarm requirements in § 182.530. On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: A machinery space bilge, bilge well, shaft alley bilge, or other spaces subject to flooding from sea water piping within the space. High level alarm for engine room found not working. Captain of vessel stated that he cut the wires to it because it was going off non stop.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 9 July 2025
Resolved 9 July 2025
Resolution: All high level alarms tested and working.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 26 June 2025
Resolved
On or before March 11, 1999, an existing vessel must comply with the bilge high level alarm requirements in § 182.530. On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: A machinery space bilge, bilge well, shaft alley bilge, or other spaces subject to flooding from sea water piping within the space. High level alarm for rudder room found not working.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 9 July 2025
Resolved 14 July 2025
Resolution: High level alarm repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 June 2025
Resolved
At least one ring life buoy must be fitted with a 60 ft lifeline. Vessel has no lifelines attached to the ring buoys.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 9 July 2025
Resolved 15 July 2025
Resolution: Life line properly attached.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 June 2025
Resolved
A vessel must carry one floating water light. Floating water light on second deck STBD side inoperable.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 9 July 2025
Resolved 15 July 2025
Resolution: Floating water light repaired.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 26 June 2025
Resolved
Shutoff valves. installed so as to close against the fuel flow shall be fitted in the fuel supply line one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. The shutoff valve at the tank shall be operable from outside the tank compartment, preferably from an accessible position on the weather deck. Remotes for fuel tank shut off valves were found disconnected from the valve assembly.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 9 July 2025
Resolved 14 July 2025
Resolution: Control cable properly repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 June 2025
Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 910 millimeters (3 feet) in length, but not more than 1,830 millimeters (6 feet), securing the water light around the body of the ring life buoy. Floating water light lanyard wasted.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2025
Resolved 15 July 2025
Resolution: Floating waterlight lanyard repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 June 2025
Resolved
Each ring life buoy must be marked with Type II retro-reflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. None of the ring life buoys were marked with retroreflective tape.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 9 July 2025
Resolved 15 July 2025
Resolution: retro reflective tape installed.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 26 June 2025
Resolved
A vessel on a lakes, bays, and sounds, or rivers route must carry three hand red flare distress signals approved in accordance with 46 CFR 160.021 and three hand orange smoke distress signals approved in accordance with 46 CFR 160.037. Three hand red flares were found expired.
Action required: 60 - Rectify deficiencies prior to movement
Due 9 July 2025
Resolved 10 July 2025
Resolution: Red flares purchased.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 June 2025
Resolved
The owner, charterer, master or managing operator shall instruct each crew member, upon first being employed and prior to getting underway for the first time on a particular vessel and at least once every three months, as to the duties that the crew member is expected to perform in an emergency including, but not limited to, the emergency instructions listed on the emergency instruction placard required by § 185.510 of this part. Drills have not been completed and documented as required.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2025
Resolved 10 July 2025
Resolution: Drill logs created and performed at the dock with crew.
02 - Structural Conditions › N/A - No Subsystem › Wheelhouse -door -window
Issued 26 June 2025
Resolved
Each window, port hole, and its means of attachment to the hull or deck house, must be capable of withstanding the maximum load from wave and wind conditions expected due to its location on the vessel and the authorized route of the vessel. Window on bridge stbd side fractured.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2025
Resolved 10 July 2025
Resolution: Broken window replaced.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 26 June 2025
Resolved
Unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle, waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom. Vessel was found utilizing combustible waste receptacles.
Condition: Design Flaw
Action required: 60 - Rectify deficiencies prior to movement
Due 9 July 2025
Resolved 10 July 2025
Resolution: Plastic trash cans removed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 June 2025
Resolved
A marine employer whose vessel is involved in a casualty or incident that is, or is likely to become, a serious marine incident as defined in § 4.03-2 of subchapter A of this chapter shall comply with the requirements of § 4.06 in subchapter A of this chapter. Alcohol testing device required by 46 CFR 4.06-3 was not available. Captain of vessel stated he was not aware of how alcohol testing would be conducted.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 9 July 2025
Resolved 15 July 2025
Resolution: Alcohol test equipment purchased.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 26 June 2025
Resolved
The hailing port of the vessel must be marked on some clearly visible exterior part of the stern of the vessel. Hailing port missing from stern of vessel.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2025
Resolved 10 July 2025
Resolution: Hailing port labeled.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 June 2025
Resolved
A bilge pipe in a vessel of not more than 19.8 meters (65 feet) in length must be not less than 25 millimeters (1 inch) nominal pipe size. A bilge pipe in a vessel of more than 19.8 meters (65 feet) in length must be not less than 40 millimeters (1.5 inches) nominal pipe size. A bilge suction must be fitted with a suitable strainer having an open area not less than three times the area of the bilge pipe. All bilge suction screens are plastic and do not meet size requirements. Rudder room completely missing suction screen.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 9 July 2025
Resolved 10 July 2025
Resolution: Proper bilge suction screens installed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 June 2025
Resolved
All vessels shall be provided with bilge pumps in accordance with Table 182.25-10(a) - 2 fixed power pumps rated at 50 GPM. Fixed power pump installed on starboard engine inoperable.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 9 July 2025
Resolved 15 July 2025
Resolution: Fixed power pump repaired.
14 - Pollution Prevention › N/A - No Subsystem › VGP: General
Issued 26 June 2025
Resolved
At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris, or other matter that might create a fire hazard, clog bilge pumping systems, or block emergency escapes. Rudder space found to have oily sludge in bilge.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2025
Resolved 15 July 2025
Resolution: rudder space bilge cleaned.
09 - Working and Living Conditions › 091 - Living Conditions › Dirty, parasites
Issued 26 June 2025
Resolved
At each inspection for certification and at every other vessel inspection, quarters, toilet and washing spaces, galleys, serving pantries, lockers, and similar spaces may be examined to determine that they are serviceable and in a sanitary condition. Insect infestation found throughout vessel to include bar area and galley.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 9 July 2025
Resolved 10 July 2025
Resolution: Vessel was exterminated and bugs removed.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 26 June 2025
Resolved
Suitable covers, guards, or rails shall be installed in way of all exposed and hazardous places such as gears, machinery, etc. Belt guard missing from starboard engine.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2025
Resolved 10 July 2025
Resolution: Belt guard installed.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 26 June 2025
Resolved
At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris, or other matter that might create a fire hazard, clog bilge pumping systems, or block emergency escapes. Engine room bilges filled with rags that would prevent bilge suction from operating correctly.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 9 July 2025
Resolved 10 July 2025
Resolution: Rags removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 June 2025
Resolved
In systems and applications where flexible hoses are permitted to be clamped: Double hose clamping is required where practicable. Secondary hose clamp is broken on both port and stbd MDE exhaust piping.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 9 July 2025
Resolved 10 July 2025
Resolution: Required hose clamps installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 June 2025
Resolved
Batteries shall be effectively screened by a cage or similar structure to minimize the danger of accidental spark through dropping a metal object across terminals. All batteries in engine room found without protective covers.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 9 July 2025
Resolved 10 July 2025
Resolution: Battery covers installed.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 26 June 2025
Resolved
Remote fuel shutoff stations shall be marked in at least 1-inch letters indicating purpose of the valve and direction of operation. Remote fuel shutoff stations are not marked with direction of use.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2025
Resolved 15 July 2025
Resolution: Shutoff stations properly labeled.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 26 June 2025
Resolved
Except where specifically stated otherwise, an existing vessel must comply with the intact stability and seaworthiness regulations which were applicable to the vessel on March 10, 1996, or, as an alternative, the vessel may comply with the regulations in this part. Exhaust piping for generator removed leaving a hole in the hull of the engine room.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2025
Resolved 10 July 2025
Resolution: Generator exhaust installed.
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 26 June 2025
Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years. Vessel does not have updated Radio Telephony Certificate.
47CFR80.902
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2025
Resolved 20 August 2026
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 26 June 2025
Resolved
One ship station license will be granted for operation of all maritime services transmitting equipment on board a vessel. Vessel does not have the required Station license.
47CFR80.13
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2025
Resolved 6 August 2025
Resolution: Obtained station license.
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 26 June 2025
Resolved
Except as provided in §§ 80.177 and 80.179, operation of transmitters of any ship station must be performed by a person holding a commercial radio operator license or permit of the class required below. The operator is responsible for the proper operation of the station. No one onboard has a Radio Operator permit. 47CFR80.155
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2025
Resolved 10 July 2025
Resolution: [name withheld] has vessel operator permit.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 June 2025
Resolved
Fuel fill screw caps shall be suitably marked for identification. Fuel fills are not marked "DIESEL".
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2025
Resolved 10 July 2025
Resolution: Fuel fill properly labeled.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 26 June 2025
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. First aid kit missing required contents.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2025
Resolved 10 July 2025
Resolution: First AID kit purchased.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 June 2025
Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets and immersion suits. Storage compartment on main deck aft around bar area, missing label for lifejacket amount in that location.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2025
Resolved 10 July 2025
Resolution: Extra lifesaving equipment removed from lockers.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 June 2025
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Storage location for child life jackets did not have an appropriate means for separation.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2025
Resolved 15 July 2025
Resolution: life jackets properly separated.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 June 2025
Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Vessel has multiple different life jackets but missing the donning instructions for new life jackets purchased.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2025
Resolved 10 July 2025
Resolution: Donning instructions supplied for extra jackets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 June 2025
Resolved
Each life jacket must be marked in clearly legible block capital letters with the vessel's name. Name of vessel missing on new life jackets.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2025
Resolved 15 July 2025
Resolution: name of vessel placed on new life jackets.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 June 2025
Resolved
A portable or temporary electric cord or cable must be constructed and used in compliance with the requirements of §111.60-13 in subchapter J of this chapter for a flexible electric cord or cable. No flexible cord may be used except as allowed under Sections 400-7 and 400-8 of NFPA NEC 2002. Unless specifically permitted in 400.10, flexible cables, flexible cord sets, and power supply cords shall not be used for the following: (1) As a substitute for the fixed wiring of a structure. Permanently installed extension cords are being used in rudder space.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2025
Resolved 10 July 2025
Resolution: Extension cord removed from rudder space.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 26 June 2025
Resolved
An existing vessel equipped with machinery powered by gasoline or other fuels having a flash point of 43.3 °C (110 °F) or lower must comply with the requirements of § 182.410(c) on or before March 11, 1999. An enclosed space containing machinery powered by gasoline or other fuels having a flash point of 43.3 °C (110 °F) or lower must be equipped with a flammable vapor detection device in compliance with § 182.480. Gasoline powered pump found stored in rudder space.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 9 July 2025
Resolved 10 July 2025
Resolution: Gasoline pump removed from vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 June 2025
Resolved
Main propulsion machinery. The marine inspector may require that the main propulsion machinery be operated both ahead and astern. The attached, auxiliary machinery and cooling water system shall be checked. STBD MDE has leak on the jacket water expansion tank.
46CFR176.25-10(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2025
Resolved 10 July 2025
Resolution: Jacket water expansion tank repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 June 2025
Resolved
Main propulsion machinery. The marine inspector may require that the main propulsion machinery be operated both ahead and astern. The attached, auxiliary machinery and cooling water system shall be checked. Belt that controls alternator and R/W cooling pump on the STBD MDE is loose and can be moved by hand.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 10 July 2025
Resolved 15 July 2025
Resolution: New belt installed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 June 2025
Resolved
Battery terminal connections shall be made with permanent type connectors. Spring clips and other temporary type clamps are not permitted. Wing nuts found on battery terminals.
OLD T 46 CFR 183.05-20
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2025
Resolved 10 July 2025
Resolution: Wing nuts removed from battery.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 3 October 2024
Resolved
Operator applied cement patch on bottom plate located underneatht the port main engine. Operator instructed to remove cement patch and make proper repairs. Vessel entered dry dock at Hurricane Cove Shipyard on October 3, 2024. Observed satisfactory cutout of bottom plate. Repair continues. Make proper repairs prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 October 2024
Resolution: Observed satisfactory NDT by dye pen of new insert.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 3 October 2024
Resolved
Observed hole on starboard exterior side shell in way of forward concession stand. Make proper repairs to prevent water intrusion into main salon.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 October 2024
Resolution: Observed satisfactory repair.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 3 October 2024
Resolved
Operator applied composite material in way of broken weld seam in way of the starboard support beam located on 2nd deck aft of the wheel house, allowing water intrusion inside the vessel. Observed water droplets dripping from the ceiling in main salon. Suspected source of water intrusion coming from broken weld seam. Make proper repairs to prevent water intrusion.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 October 2024
Resolution: Observed satisfactory repairs to broken weld seam.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 3 October 2024
Resolved
Found wasted bottom plate located in lazarette, aft port corner. Crop and renew wasted metal to good material.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 October 2024
Resolution: Observed satisfactory NDT by dye pen of new insert.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 September 2024
Resolved
A vessel must be provided with a main steering gear that is:(1) Of adequate strength and capable of steering the vessel at all service speeds. Office received a report that vessel is experiencing steering issues. Marine inspector will attend vessel to confirm the condition of steering test. Vessel is restricted from carrying passengers until test is complete with marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 September 2024
Resolved 28 September 2024
Resolution: Satisfactory steering test conducted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 11 April 2024
Resolved
Shutoff valves, installed so as to close against the fuel flow, shall be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. The shutoff valve at the tank shall be operable from outside the tank compartment, preferable from an accessible position on the weather deck. Vessel is missing fuel shutoff valves due to deck work making them inaccessible.
46 CFR § 182.20-40 (3)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 April 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 11 April 2024
Resolved
On or before March 11, 1999 an existing vessel must comply with the bilge high level alarm requirements in 182.530. Vessel has 04 bilge high level alarms that are inoperable and must be fixed.
46 CFR § 182.115 (d)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 April 2024
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 11 April 2024
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. Weld port side aft deck plate where there is a hole to the lazarette.
46 CFR § 177.115
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 April 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 April 2024
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Separate children's and adults life jackets and properly label the stowage space.
46 CFR § 180.78(a)(5)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 April 2024
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 11 April 2024
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. Make proper repairs to leak in way of starboard fresh water fill.
46 CFR § 177.115
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 April 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 April 2024
Resolved
The name of a vessel must be marked or painted in clearly legible letters and number. Each life jacket, immersion suit, and ring life buoy must be marked in clearly legible block capital letters with the vessel's name. Properly label all lifesaving equipment including
life jackets and ring buoys.
46 CFR § 185.604 (b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 May 2024
02 - Structural Conditions › N/A - No Subsystem › Marking of IMO number
Issued 11 April 2024
Resolved
For vessels other than those covered in paragraphs (b)
and (c) of this section, the name of the vessel must be
on some clearly visible exterior part of the port and
starboard bow and stern of the vessel. Properly label
vessel's hull.
46 CFR § 67.123 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 May 2024
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 11 April 2024
Resolved
Each EPIRB ... must be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative; The EPIRB test required by paragraph (a) shall be logged or otherwise documented, as applicable. Master must ensure monthly test is being done and logged.
46 CFR § 185.728 (c)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 June 2024
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 11 April 2024
Resolved
Except as provided in § 80.13(c), stations must have an authorization granted by the Federal Communications Commission. Obtain a valid FCC Station License.
47 CFR § 80.405
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 October 2024
Resolution: Vessel restricted to within 1000 ft from shore.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 11 April 2024
Resolved
Except as provided in § 173.17, no person may use a vessel to which this part applies unless: It has a number issued on a certificate of number by the issuing authority in the State of principal operation. Obtain a valid FL State Registration.
33 CFR § 173.15
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 October 2024
Resolution: Vessel operator provided evidence of valid FL State Reqistration.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 11 April 2024
Resolved
The owner or operator must conduct all tests as required by the OCMI, and make the vessel available for all specific inspections and drills. Vessel must complete satisfactory fire drill and man overboard drill in the presence of a Coast Guard Marine Inspector.
46 CFR 176.404(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 April 2024
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 11 March 2024
Resolved
Operating without a valid COI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 April 2024
Resolution: Completed satisfactory COI inspection.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 March 2024
Resolved
Failure to meet requirements of 46 CFR Part 16
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 April 2024
Resolution: Provided evidence of program compliance
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 15 February 2024
Resolved
To maintain a valid Certificate of Inspection, you must complete your annual inspection within the periods specified in § 176.500(b)(1) [annual inspection within 3 months before or after each anniversary date] and your Certificate of Inspection must be endorsed. Vessel did not complete annual COI inspection w/i 3 months before or after anniversary date.
46 CFR 176.502
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 April 2024
Resolution: Completed COI Renewal
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 20 October 2022
Resolved
Vessel missing FCC Station License. Provide valid station license.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 October 2022
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 20 October 2022
Resolved
Vessel not equipped with an EPIRB on a Limited Coastwise route. Vessel restricted to within 3 miles of shore until vessel is installed with a valid EPIRB.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 October 2022
Resolution: Vessel installed new EPIRB.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 20 October 2022
Resolved
Vessel's PA system not working properly. Make repairs for proper operation of PA system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 October 2022
Resolution: Witnessed proper operation of PA system.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 October 2022
Resolved
Ground detection is not functioning properly. Make proper repairs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 October 2022
Resolution: Witnessed satisfactory repair of ground detection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 October 2022
Resolved
Vessel not equipped with serviceable life buoys, provide 3 life buoys in serviceable conditions.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 October 2022
Resolution: Witnessed 3 ring buoys on board vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 October 2022
Resolved
Properly mark stowage of life jackets.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 October 2022
Resolution: Observed proper marking of life jacket stowage.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 October 2022
Resolved
Observed excessive leaking from shaft seal. Make proper repairs to shaft seal.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 October 2022
Resolution: Witnessed satisfactory repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 October 2022
Resolved
Did not witness satisfactory bilge suction from steering compartment. Make proper repairs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 October 2022
Resolution: Witnessed satisfactory test of the bilge system from steering compartment.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 October 2022
Resolved
High level bilge alarms did not operate from steering compartment and engine room to indicators on the bridge.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 October 2022
Resolution: Witnessed satisfactory test of high level bilge alarms from all compartments.
10 - Safety of Navigation › N/A - No Subsystem › Monitoring of voyage or passage plan
Issued 20 October 2022
Resolved
Vessel missing marking indicating passenger capacity on upper deck. Install proper marking for passenger capacity on upper deck.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 October 2022
Resolution: Vessel installed passenger capacity for upper deck limitations.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 18 January 2022
Resolved
To maintain a valid Certificate of Inspection, you must complete your annual inspection within the periods specified in 176.500(b)(1) [annual inspection within 3 months before or after each anniversary date] and your Certificate of Inspection must be endorsed. Vessel is outside of three month window for Inspection and is not permitted to operate until annual inspection has been completed.
46CFR176.502
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 October 2022
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 23 June 2020
Resolved
Life ring must be relabeled with vessel name and grabline must be replaced.
46 CFR 180.70
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2020
Resolved 9 September 2020
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 June 2020
Resolved
Deep fat fryer in galley must be removed.
46 CFR 184.700
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 23 June 2020
Resolved 23 June 2020
Resolution: fryer was removed before inspection team departed
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 23 June 2020
Resolved
Upper deck passenger capacity placard must be replaced at the entraceway to that deck.
46 CFR 185.602
Action required: 705 - Other - as specified
Due 30 June 2020
Resolved 9 September 2020
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 18 June 2019
Resolved
46 CFR 182.530 (a)- On a vessel of at least 26 ft a visual and audible alarm must be provided at the operating station to indicate a high water level. Rudder Room visual indication was not working., replace as necessary.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 June 2019
Resolution: Bilge alarm replaced
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 18 June 2019
Resolved
46 CFR 185.604 (i)-Each ring life buoy must be marked with type II retroreflective material. Retro-reflective tape on life buoy is deteriorated and needs to be replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 June 2019
Resolution: Picture submitted of fixed tape
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 June 2019
Resolved
46 CFR 183.200 (b) Electrical equipment on a vessel must be installed and maintained to protect passengers, crew and other persons from electrical hazards including fire caused by or originating from electrical equipment. Vessel has 03 extension cords used on main deck for lights.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 June 2019
Resolution: Removed from vessel
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 18 June 2019
Resolved
46CFR 180.68 (a) A vessel on a limited Coastwise route needs 6 red flares and 6 orange hand smoke distress signals. Vessel only has 11 flares on board. Needs one more.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 June 2019
Resolution: New flares on board
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 18 June 2019
Resolved
47 CFR 80.903- Every vessel subject must have an inspection of the radio installation once every five years by an FCC licensed technician.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 June 2019
Resolution: FCC documentation updated and sent in
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 27 September 2018
Resolved
Vessels on partially protected routes are required to have 6 day and 6 night signal flares. Add 3 day flares and 2 night flares. 46CFR180.35-5(a)1
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 September 2018
Resolution: recieved email with photo evidence of rectified deficiency.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 September 2018
Resolved
Rubber couplings on pipes should be double clamped. Various couplings throughout engine compartment found inadequate. Double clamp all couplings identified during inspection.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 October 2018
Resolution: operator sent photo evidence via email.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 27 September 2018
Resolved
Shutoff cylinoid terminal connector on auxilary engine needs replaced with fully enclosed terminal lug.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 October 2018
Resolution: Recieved photo evidence via email.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 27 September 2018
Resolved
Clamps on outflow pipe from generator are inadequate. Replace with correct size.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 October 2018
Resolution: recieved email with photo evidence of rectified deficiency.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 September 2018
Resolved
Vessel must complete an annual inspection prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 September 2018
Resolution: recieved email with photo evidence of rectified deficiency.
Lifesaving › Hand Flares › Expired
Issued 12 June 2017
Resolved
Vessels on a limited coastwise route are required to have 6 red distress signals and 6 daylight distress signals. Vessel is missing 3 daylight and 2 red distress signals. Replace missing distress signals.
Due 23 June 2017
Resolved 14 June 2017
Resolution: recieved copy of reciept for new flares via email.
Construction/Loadline › Hull › Bottom Plating
Issued 5 May 2016
Resolved
Provide repair proposal for portside steel hull bottom wastage under engine bed. Also, stern centerline to portside wastage.
Action required: 705 - Other - as specified
Resolved 10 May 2016
Resolution: Vessel completed satisfactory repairs IAW proposed repair plan.
Construction/Loadline › Hull › Hull Plating
Issued 5 May 2016
Resolved
Crop and renew as original wastage on centerline water tank hold bulkhead.
Action required: 705 - Other - as specified
Resolved 10 May 2016
Resolution: Vessel satisfactorly conducted repairs IAW proposed repair proposal.