MAURY USCG vessel records Sign in
← All vessels

REF VEGA

REF VEGA is a 1984 freight ship. The Coast Guard has recorded 37 inspections since 1991, most recently in December 2011, along with 59 deficiencies — 2 with no resolution recorded — and 7 operational controls.

Records from 1991 to 2011. Most recent: inspection, 27 December 2011.

Built
1984
Last inspected
27 December 2011
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8422709 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
359922
Flag
SOVIET UNION
—
Maury page id
psix-359922

Inspections, by type

…with no type recorded20
…past their stated due date2
Years with a record 17 calendar years (1991–2011)
The 37 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 15 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it4779 - Convention (Subpart B), Net Ton
12383 - Convention (Subpart B), Gross Ton
11871 - Dead Weight, Ton
19111 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 37

27 December 2011 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4208118
17 February 2010 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3680934
16 March 2009 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3623236
12 March 2009 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3432644
9 March 2009 Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3430593
18 October 2008 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3347124
17 October 2008 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3347099
10 March 2008 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3158657
22 June 2007 ISPS II Exam · MARPOL Annex V Examination · PII Safety Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2970526
20 June 2007 Type not recorded
No type recorded · Station Panama City · USCG Heartland District (CGD-H) · Activity 2968282
18 June 2007 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2966360
17 October 2006 ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2802545
2 June 2006 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2668540
31 May 2006 Ballast Water Examination · PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2666129
9 January 2006 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2563335
26 September 2005 ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2504566
12 August 2005 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2460803
8 April 2005 ILO-147 Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2329150
7 October 2004 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2215746
26 July 2004 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2146170
7 May 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2061867
24 October 2003 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1935215
22 October 2003 Ballast Water Examination · Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1933835
6 January 2003 Re-Inspection · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1726610
15 October 2002 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1690358
22 October 2001 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 294808
14 March 2001 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 287871
16 July 1999 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 430466
25 February 1998 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 447351
29 October 1997 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 409334
6 June 1997 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 404313
26 December 1996 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 40273
26 December 1996 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 398834
7 October 1996 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 396193
26 January 1996 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 387243
19 March 1995 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 376395
13 February 1991 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 341998

Deficiency record · 59

Lifesaving › Lifeboat › Watertight Enclosure
Issued 27 December 2011 No resolution recorded
0610-Lifeboats-Cargo ships shall carry one or more totally enclosed lifeboats complying with LSA Code section 4.6. A portion of the back panel of the port side lifeboat steering station is missing. Provide documentation from class society attesting to the watertight integrity of the lifeboat. 74 SOLAS (09 cons) III/31.1; 74 SOLAS (unamend) III/35; LSA Code/4.6
Action required: 705 - Other - as specified
Due 10 January 2012 — due date passed with no resolution recorded
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 27 December 2011 No resolution recorded
1030-Steering gear alarm-Ships shall be provided w/ a main steering gear to the satisfaction of the Administration. PSCO conducted test of the ship steering from the bridge, the audible alarm for steering power failure is not operational. Provide documentation from certified tech attesting to the proper operation of the steering gear alarm on the bridge. 74 SOLAS (unamend) II-1/29 and I/11
Action required: 705 - Other - as specified
Due 10 January 2012 — due date passed with no resolution recorded
Navigation › Collision/Grounding Avoidance › Automatic Radar Plotting Aid (ARPA)
Issued 27 December 2011 Resolved
1530-Radar-All ships of 3,000 gross tonnage and upwards shall have a second automatic tracking aid, or other means, to plot automatically the range and bearing of other targets. Master reported the starboard side ARPA was non-operational on the vessel's eNOA. However, during the exam PSCO received tech report attesting to proper operation of the radar. 74 SOLAS (09 cons) V/19.2.7.2
Action required: 17 - Rectify deficiencies prior to departure
Due 27 December 2011
Resolved 27 December 2011
Resolution: Received, reviewed and accepted technician report from [name withheld], LLC stating the deficiency was rectified. Tech installed a new modulator and magnetron and tested the unit with satisfactory results.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 18 October 2008 Resolved
CLASS "A" FIREDOOR LEADING FROM ENGINE ROOM TO INCINERATOR ROOM CAN NOT BE FULLY CLOSED TO MAINTAIN INTEGRITY OF CLASS "A" FIRE BOUNDATY. SOLAS '74 II-2 /23(d)
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 9 March 2009
Resolved 9 March 2009
Resolution: Received proper documentation satisfying requirement.
Engineering › Compressed Air System (start air) › Piping
Issued 18 October 2008 Resolved
COMPRESSED AIRLINE FOR STARTING OF EMERGENCY GENERATOR HAS A LEAK NEXT TO THE AFT PART OF THE CARGO HOLD #4 PORT SIDE. SOLAS '74 I / 11(a)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 9 March 2009
Resolution: Received proper documentation satisfying requirement.
Lifesaving › Lifeboat › Propeller Shaft
Issued 10 March 2008 Resolved
Lifeboat clutch will not engage shaft in reverse. Repair lifeboat clutch so proper operation of motor can be achieved.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 March 2008
Resolution: Received class report clearing this deficiency.
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 10 March 2008 Resolved
MDE and generators # 1,2, and 3 have installed hoses that are being used for fuel oil leakage, which is being deposited directly into the bilges.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 March 2008
Resolution: Received class report clearing this deficiency.
Personnel › Certificates/Documents/Licenses › License, Chief Mate
Issued 22 June 2007 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 June 2007
Resolution: Received confirmation from the vessel’s flag state that they had received the applications for endorsement for the Chief Mate and Chief Engineer and that they are eligible to sail under the temporary Panama endorsement until 15AUG2007.
Lifesaving › Lifeboat › Propulsion Engine
Issued 31 May 2006 Resolved
Port lifeboat needs to be repaired so that it will start and run. Lifeboat would not start. Should be repaired prior to departure to the satisfaction of the Coast Guard.
Action required: 17 - Rectify deficiencies prior to departure
Due 31 May 2006
Resolved 2 June 2006
Resolution: Port Lifeboat now working properly.
Engineering › Steering Gear System › Piping
Issued 8 April 2005 Resolved
Repair oil leak #1 Steering gear pump. Clean slippery deck to satisfaction of USCG.
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 April 2005
Resolved 8 April 2005
Resolution: Leak on #1 steering gear pump was repaired and deck of compartment was cleaned to satisfaction of CG marine inspector.
Operations/Management › Ballast Water Managment › Alternative Management Method
Issued 8 April 2005 Resolved
Record of ballast water reporting forms found not to be on board. Vessel to implement ballast water records that are signed and kept on board vessel for two years.
Action required: 705 - Other - as specified
Due 8 May 2005
Resolved 30 June 2005
Resolution: 30JUN05: Inspected containment--completed to the satisfaction of CG inspectors [name withheld], and [name withheld]
Lifesaving › Lifeboat › Hull
Issued 8 April 2005 Resolved
Both port and starboard lifeboats found to have damage on inboard forward cradles on hull. Temporary repairs have been placed on fractures. Class society surveyor or flag state representative to attest to lifeboat damage and overall structural integrity.
Action required: 705 - Other - as specified
Due 15 April 2005
Resolved 12 April 2005
Resolution: Class surveyor attested to the proper repair.
Lifesaving › Lifeboat › Windows/Translucent Panels
Issued 8 April 2005 Resolved
Both port and starboard aft lifeboat wheelhouse windshields cracked allowing weather/water to enter lifeboats. Repair as original to satisfaction of class society surveyor or flag state representative.
Action required: 705 - Other - as specified
Due 8 May 2005
Resolved 12 April 2005
Resolution: Class surveyor attested to the proper repair.
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 8 April 2005 Resolved
Lube oil venting on main deck missing oil containment holds. Class society surveyor or flag state representative to attend to proper placement of containment holds. **NOTE* On 12 may Russian maritime society requested 45 days to complete contaiment holds, Due 24 May 2005
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 May 2005
Resolved 30 June 2005
Resolution: 30JUN05: Inspected containment holds--built to the satisfaction of CG inspectors [name withheld] and [name withheld]
Construction/Loadline › Structures › Superstructure
Issued 8 April 2005 Resolved
Cargo hold #3 fractured IWO coming and hydraulic ram foundation. Class society surveyor or flag state representative to attest to fractures, welds and structural integrity of cargo hold #3.
Action required: 705 - Other - as specified
Due 8 May 2005
Resolved 12 April 2005
Resolution: Class surveyor attested to the proper repair.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 7 October 2004 Resolved
DIRECTED MASTER TO ARRANGE FOR CLASS SUEVEYOR TO ATTEND TO CLEAR DEFICIENCIES IDENTIFIED WITH ACTIVITY 2146170 26JUL04 PRIOR TO VESSEL DEPARTING JACKSONVILLE, FL AND FAX REPORT TO THIS OFFICE
Action required: 17 - Rectify deficiencies prior to departure
Due 7 October 2004
Resolved 9 October 2004
Resolution: RECEIVED FAXED REPORT FROM CLASS. CORRECTED TO THE SATISFACTION OF MARINE INSPECTOR
Fire Fighting › Fire Pumps › Suction Valve
Issued 26 July 2004 Resolved
Provide to the satisfaction of class that soft patch on #3 Fire Pump Suction is of adequate design and specifications for piping in accordance with SOLAS ChII-1 reg 26 Prior to next US port.
Action required: 15 - Rectify deficiencies by next port
Resolved 9 October 2004
Resolution: RECEIVED FAXED CLASS REPORT THAT DEFICIENCY WAS CORRECTED TO THE SATISFACTION OF CLASS.
Engineering › Freshwater System (piston cooling) › Piping
Issued 26 July 2004 Resolved
Repair or replace salt water line on Main Diesel engine after cooler for piston in accordance with SOLAS ChII-1 Reg 26 prior to next US port to the satisfaction of class.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 9 October 2004
Resolution: RECEIVED FAXED REPORT THAT DEFICIENCY WAS CORRECTED TO THE SATISFACTION OF CLASS
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (air intake)
Issued 26 July 2004 Resolved
Prove to the satisfaction of class that patch on main engine blower is of adequate design and specification in accordance with SOLAS Ch II-1 Reg 26 prior to next US Port.
Action required: 15 - Rectify deficiencies by next port
Resolved 9 October 2004
Resolution: RECEIVED FAXED REPORT THAT DEFICIENCY WAS CORRECTED TO THE SATISFACTION OF CLASS
Construction/Loadline › Structures › Door
Issued 26 July 2004 Resolved
Repair/replace emergency generator door in accordance with ILLC 66 Annex I reg 12 prior to next US port.
Action required: 15 - Rectify deficiencies by next port
Resolved 9 October 2004
Resolution: RECEIVED FAXED REPORT THAT DEFICIENCY WAS CORRECTED TO THE SATISFACTION OF CLASS.
Fire Fighting › Remote Fuel Shutoff
Issued 22 October 2003 Resolved
Remote control for F/O shutdown panel is made of plexiglass, and is permanently affixed. Crew unable to open for periodic servicing /testing or use during an emergency. SOLAS 74/78 (unamended) II-2 Reg. 50b
Condition: Improper Installation
Due 22 November 2003
Resolved 24 October 2003
Fire Fighting › Miscellaneous Items
Issued 15 October 2002 Resolved
Replace piping which connects and is between #2 and #3 fire pumps. Noted adjacent piping to also be wasted and easily holed by tapping with hammer.
Action required: 705 - Other - as specified
Due 15 October 2002
Resolved 9 January 2003
Resolution: Received Class report Via Fax from ABS. ABS attested to the correction of the replacement of the piping.
Accommodation/Occupational Safety › Washroom/Toilet
Issued 15 October 2002 Resolved
Provide hot and cold running water and operable toilet for hospital space. Vsl is using operating room w/ no facilities as hospital space. Explained to Master that it was impracticle for sick/injured mbr's to walk entire athawrtship to use facilities. Def. is to USCG sat.as vsl is not sig. to ILO. LEGACY COMPONENT DESC: Hot and Cold Running Water
Action required: 705 - Other - as specified
Due 15 October 2002
Resolved 6 January 2003
Resolution: Vessel has Hot and Cold Running Water in Hospital space.
Lifesaving
Issued 16 July 1999 Resolved
MAKE PERMANENT REPAIRS TO STARBOARD LIFEBOAT ENGINE TO INCLUDE COOLING WATER, AND EXHAUST LEAK._x001C_ SOLAS 74 (AMENDED) 111/41.6.3
Condition: Unknown
Due 16 July 1999
Resolved 19 July 1999
Unknown
Issued 7 October 1996 Resolved
MARINE SANITATION DEVICE DOES NOT HAVE U. S. COAST GUARD CERTIFICATION LETTER, 33CFR159.7
Condition: Unknown
Due 30 December 1996
Resolved 30 December 1996
Accommodation/Occupational Safety
Issued 26 January 1996 Resolved
RENEW MISSING NATURAL VENTILATION CLOSEURE LOCATED AFT ON #2 DECK._x001C_ SOLAS 74 AMENDED II-2/16.9
Condition: Unknown
Due 6 February 1996
Resolved 6 February 1996
Electrical
Issued 26 January 1996 Resolved
RENEW/ REPAIR INOPERABLE EMERGENCY LIGHTING FIXTURE LOCATED ON THE AFT DECKHOUSE STARBOARD SIDE ON THE MAIN DECK. SOLAS 74 AMENDED II-1/42.2_x001C_
Condition: Unknown
Due 6 February 1996
Resolved 6 February 1996
Fire Fighting
Issued 26 January 1996 Resolved
RENEW/ REPAIR DETERIORATED/ MISSING COVERS FOR FIRE FIGHTING SAND BOXES_x001C_ LOCATED FORWARD ON THE AFT DECK HOUSE. SOLAS 74 AMENDED II-2/21
Condition: Unknown
Due 6 February 1996
Resolved 6 February 1996
Fire Fighting
Issued 26 January 1996 Resolved
RENEW DETERIORATED HOSES TO PORTABLE FIRE FIRE EXTINGUISHERS LOCATED IN THEEMERGENCY GENERATOR ROOM. SOLAS 74 AMENDED II-2/21
Condition: Unknown
Due 6 February 1996
Resolved 6 February 1996
Engineering
Issued 26 January 1996 Resolved
RE-ATTACH EMERGENCY CUT OUT FOR FUEL OIL SUPPLY TO MAIN ENGINE. #a.22
Condition: Unknown
Due 6 February 1996
Resolved 6 February 1996
Lifesaving
Issued 26 January 1996 Resolved
REMOVE OIL AND OIL RESIDUE FROM AREA SURROUNDING SEPERATORS.
Condition: Unknown
Due 6 February 1996
Resolved 6 February 1996
Lifesaving
Issued 26 January 1996 Resolved
REMOVE EXCESS OIL FROM DECK IN STEERING GEAR ROOM.
Condition: Unknown
Due 6 February 1996
Resolved 6 February 1996
Engineering
Issued 26 January 1996 Resolved
RENEW AS ORGINAL DETERIORATED COOLING WATER SUPPLY PIPE FOR MAIN ENGINE_x001C_ FUEL VALVES. STARBOARD SIDE IN BOARD OF #3 AIR COMPRESSER.
Condition: Unknown
Due 6 February 1996
Resolved 6 February 1996
Electrical
Issued 26 January 1996 Resolved
RENEW AS ORIGINAL DETERIORATED SEA WATER COOLING SUPPLY PIPE TO #3 AIR_x001C_ COMPRESSOR.
Condition: Unknown
Due 6 February 1996
Resolved 6 February 1996
Electrical
Issued 26 January 1996 Resolved
RENEW AS ORIGINAL DETERIORATED SEA WATER COOLING SUPPLY PIPE TO #1 AIR_x001C_ COMPRESSOR.
Condition: Unknown
Due 6 February 1996
Resolved 6 February 1996
Engineering
Issued 26 January 1996 Resolved
RENEW AS ORIGINAL DETERIORATED STEAM PIPING LOCATED IN LOWER LEVEL ENGINE_x001C_ ROOM, FORWARD STARBOARD CORNER.
Condition: Unknown
Due 6 February 1996
Resolved 6 February 1996
Lifesaving
Issued 26 January 1996 Resolved
REMOVE EXCESS PAINT STOWED IN LOWER LEVEL ENGINE ROOM FORWARD.
Condition: Unknown
Due 6 February 1996
Resolved 6 February 1996
Lifesaving
Issued 26 January 1996 Resolved
REMOVE OIL AND OIL RESIDUE FROM ENGINE ROOM CONTAINMENTS.
Condition: Unknown
Due 6 February 1996
Resolved 6 February 1996
Lifesaving
Issued 26 January 1996 Resolved
PROVIDE AND POST EMERGENCY MUSTER LIST AND INSTRUCTIONS IN THE ENGINE _x001C_ ROOM IN A CONSPICUOUS PLACE. MUST BE IN LANGUAGE UNDERSTOOD BY THE CRE. SOLAS 74 AMENDED III/8.3
Condition: Unknown
Due 6 February 1996
Resolved 6 February 1996
Fire Fighting
Issued 26 January 1996 Resolved
PROVIDE ON BOARD, INSTRUCTIONS FOR MAINTENANCE AND OPERATION OF ALL_x001C_ INSTALLATIONS FOR MAINTENANCE AND EQUIPMENT FOR FIGHTING AND CONTAINMENT _x001C_ OF FIRE. SOLAS 74 AMENDED II-2/20
Condition: Unknown
Due 6 February 1996
Resolved 6 February 1996
Lifesaving
Issued 26 January 1996 Resolved
PROVIDE ON BOARD VESSEL, TRAINING MANUAL FOR LIFESAVING APPLIANCES._x001C_ SOLAS 74 AMENDED III/18.2/51
Condition: Unknown
Due 6 February 1996
Resolved 6 February 1996
Fire Fighting
Issued 26 January 1996 Resolved
RENEW AS ORIGINAL DETERIORATED FIRE MAIN PIPING TO FIRE HYDRANT LOCATED AFTON PORT BOAT DECK. SOLAS 74 AMENDED II-2/21
Condition: Unknown
Due 6 February 1996
Resolved 6 February 1996
Lifesaving
Issued 26 January 1996 Resolved
REMOVE EXCESS PAINT AND FLAMMABLE LIQUIDS STOWED IN THE FORWARD BOSN HOLD_x001C_ SOLAS 74 AMENDED II-2/18.7
Condition: Unknown
Due 6 February 1996
Resolved 6 February 1996
Fire Fighting
Issued 26 January 1996 Resolved
RENEW DETERIORATED DISCHARGE HOSE TO PORTABLE CO2 FIRE EXTINGUISHER LOCATEDIN THE ENGINE CONTROL ROOM. SOLAS 74 AMENDED II-2/21
Condition: Unknown
Due 6 February 1996
Resolved 6 February 1996
Accommodation/Occupational Safety
Issued 26 January 1996 Resolved
RENEW/ REPAIR INOPERABLE NATURAL VENTILATION CLOSURE LOCATED STARBOARD_x001C_ SIDE ON THE #3 DECK HOUSE. SOLAS 74 AMENDED II-2/16.9
Condition: Unknown
Due 6 February 1996
Resolved 6 February 1996
Accommodation/Occupational Safety
Issued 26 January 1996 Resolved
RENEW/ REPAIR INOPERABLE NATURAL VENTILATION CLOSURES LOCATED ON THE_x001C_ ROOF OF THE #3 DECK HOUSE. SOLAS 74 AMENDED II-2/16.9
Condition: Unknown
Due 6 February 1996
Resolved 6 February 1996
Fire Fighting
Issued 26 January 1996 Resolved
PROVIDE A GASKET FOR INTERNATIONAL SHORE CONNECTION. SOLAS 74 AMENDED II-2_x001C_19.4
Condition: Unknown
Due 6 February 1996
Resolved 6 February 1996
Lifesaving
Issued 26 January 1996 Resolved
REMOVE EXCESS OIL AND OIL RESIDE FROM THE MOTOR ROOM LOCATED IN THE #1_x001C_ DECK HOUSE.
Condition: Unknown
Due 6 February 1996
Resolved 6 February 1996
Accommodation/Occupational Safety
Issued 26 January 1996 Resolved
RENEW/ REPAIR DETERIORATED NATURAL VENTILATION DUCTS LOCATED ON THE _x001C_ STARBOARD SIDE OF THE #1 DECK HOUSE. SOLAS 74 AMENDED II-2/16.9
Condition: Unknown
Due 6 February 1996
Resolved 6 February 1996
Deck/Cargo
Issued 26 January 1996 Resolved
RENEW/ MISSING VENTILATION CLOSURE FOR THE FORWARD PAINT LOCKER._x001C_ SOLAS 74 AMENDED II-2/16.9
Condition: Unknown
Due 6 February 1996
Resolved 6 February 1996
Fire Fighting
Issued 26 January 1996 Resolved
RENEW/ REPAIR INOPERABLE SPRINKLER SYSTEM ACTIVATION VALVES FOR THE FORWARDPAINT LOCKER. SOLAS 74 AMENDED II-2/18.7_x001C_
Condition: Unknown
Due 6 February 1996
Resolved 6 February 1996
Fire Fighting
Issued 26 January 1996 Resolved
RENEW AS ORIGINAL DETERIORATED FIRE MAIN PIPING LOCATED ON THE MAIN DECK,_x001C_ PORTSIDE OF #3 DECK HOUSE. SOLAS 74 AMENDED II-2/21
Condition: Unknown
Due 6 February 1996
Resolved 6 February 1996
Lifesaving
Issued 26 January 1996 Resolved
PROVIDE ON BOARD VESSEL, INSTRUCTIONS FOR ON BOARD MAINTENANCE OF LIFESAVING APPLIANCES. SOLAS 74 AMENDED III/19.3/52
Condition: Unknown
Due 6 February 1996
Resolved 6 February 1996
Navigation
Issued 26 January 1996 Resolved
PROVIDE REQUIRED WARNING STATEMENT FOR MANEUVERING FACT SHEET. _x001C_ 33 CFR 164.35(g)
Condition: Unknown
Due 6 February 1996
Resolved 6 February 1996
Lifesaving
Issued 26 January 1996 Resolved
RENEW RETRO REFLECTIVE MATERIAL TO PORT AND STARBOARD LIFE BOATS,_x001C_ LIFE BOATS SHALL BE FITTED WITH RETRO REFLECTIVE MATERIAL IN ACCORDANCE_x001C_ WITH SOLAS 74 AMENDED III/30.2.7
Condition: Unknown
Due 6 February 1996
Resolved 6 February 1996
Lifesaving
Issued 26 January 1996 Resolved
CONDUCT SATISFACTORY FIRE AND ABANDON SHIP DRILL TO THE SATISFACTION OF_x001C_ THE ATTENDING U.S.C.G. INSPECTOR.
Condition: Unknown
Due 6 February 1996
Resolved 6 February 1996
Lifesaving
Issued 26 January 1996 Resolved
RENEW/ REPAIR STARBOARD LIFERAFT CONTAINER TO BE WATERTIGHT, EXCEPT FOR_x001C_ DRAIN HOLES IN THE CONTAINER BOTTOM. SOLAS 74 AMENDED III/39.7.3
Condition: Unknown
Due 6 February 1996
Resolved 6 February 1996
Fire Fighting
Issued 26 January 1996 Resolved
RENEW ALL DEFECTIVE FIRE HOSES THROUGHOUT THE VESSEL. SOLAS 74 AMENDED_x001C_ II-2/20
Condition: Unknown
Due 6 February 1996
Resolved 6 February 1996
Electrical
Issued 26 January 1996 Resolved
PROPERLY SECURE ELECTRICAL DISTRIBUTION BOX LOCATED CENTER LINE AFT ON THE_x001C_#2 DECK. SOLAS 74 AMENDED II-1/45.5.5
Condition: Unknown
Due 6 February 1996
Resolved 6 February 1996

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.