← All vessels
MARIANNE
Freight Ship · Refrigerated Cargo Ship class · Built 1980s · USCG Northeast District (CGD-NE) · Other hulls named MARIANNE
MARIANNE is a 1986 freight ship. The Coast Guard has recorded 32 inspections since 1991, most recently in January 2010, along with 46 deficiencies and 4 operational controls.
Records from 1991 to 2010. Most recent: inspection, 28 January 2010.
- Built
- 1986
- Last inspected
- 28 January 2010
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 46 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
8613451 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
3EPK7
359931
Flag
PANAMA
—
Maury page id
psix-359931
Inspections, by type
The 32 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 1984.
Documentation record
Tonnage as PSIX records it3330 - Convention (Subpart B), Net Ton
5756 - Convention (Subpart B), Gross Ton
7234 - Dead Weight, Ton
10875 - Displacement, Ton
5756 - Convention (Subpart B), Gross Ton
7234 - Dead Weight, Ton
10875 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 32
28 January 2010
PII Safety Exam · ISPS III Exam
Physical examination · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 3667173
4 April 2008
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3177374
1 June 2005
Ballast Water Examination · PII Safety Exam · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2375430
23 July 2004
PI Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 2141658
2 June 2004
MARPOL Annex V Examination · MARPOL Annex I Examination · Annual Inspection · Ballast Water Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2086156
18 December 2003
Ballast Water Examination
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1969223
10 December 2003
Ballast Water Examination · Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1961673
10 December 2003
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2010168
7 November 2003
Security Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1944959
8 July 2003
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1843320
5 June 2003
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1810603
29 May 2003
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1805849
28 May 2003
Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1804599
10 April 2002
Annual Inspection · MARPOL Annex V Examination · Passenger/Freight Vessel Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1603332
1 February 2002
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1481536
5 March 2001
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 287675
24 April 2000
Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 276964
19 February 2000
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 274223
21 May 1999
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 428710
14 August 1998
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 419216
3 February 1997
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 400431
18 November 1995
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 384954
21 August 1995
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 381814
31 May 1994
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 498738
11 March 1994
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 365114
11 March 1994
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 367462
18 December 1992
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 523581
25 January 1992
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 348581
16 August 1991
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 648746
18 April 1991
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 343213
19 March 1991
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 342547
19 February 1991
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 341987
Deficiency record · 46
Lifesaving › Lifeboat › Speed
Issued 28 January 2010
Resolved
Mast step for portside lifeboat missing. Provide arrangement for properly securing the foot of the mast.
Rectify deficiency prior to departure. SOLAS 74 Consd. 2004 CH I Reg 11
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 28 January 2010
Resolved
Chief Engineer does not have current Panamanian endorsement to national license, nor an application for new endorsement on file. Rectify deficiency prior to departure.
Lifesaving › Lifeboat › Propulsion Engine
Issued 28 January 2010
Resolved
After numerous attempts crew was unable to start motor on starboard side lifeboat/rescue boat. Repair engine to where it shall be capable to be started in all conditions.
Lifesaving › Lifeboat › Lifeline (becketed)
Issued 4 April 2008
Resolved
Vessels portside lifeboat grab line has 2 broken eyes for the starboard side grab line. Repair or replace eyelets and restring grab lines. SOLAS Chapter III, Reg 5.a
Lifesaving › Lifeboat Equipment › Bailer/Bucket
Issued 1 June 2005
Resolved
Both lifebaots were missing buoyant bailers.
Cite: LSA Code IV Reg. 4.4.8.3
Lifesaving › Lifeboat Equipment › Survival Manual
Issued 1 June 2005
Resolved
Both lifebaots are missing survival manuals.
Cite: LSA Code Chapter IV Reg. 4.4.8.4
Lifesaving › Lifeboat Equipment › Tin-opener
Issued 1 June 2005
Resolved
Both lifeboats are missing 02 can openers.
Cite: LSA Code Chapter IV Reg. 4.4.8.23
Electrical › Electric Generation Source (emergency) › Conductor
Issued 23 July 2004
Resolved
Electrical insulating mats are to be installed IWO of the emergency generator switchboard IAW SOLAS, Ch. II-1, Regulation 45.2.
Lifesaving › Launching Appliances › Block
Issued 23 July 2004
Resolved
The aft releasing block, where the wire falls attach to the lifeboat, on the starboard lifeboat is to be renewed due to excessive wastage (SOLAS Ch. III, Regulation 20).
Construction/Loadline › Structures › Trunk
Issued 23 July 2004
Resolved
The landing platform, IWO the engineroom emergency escape trunk, is to be renewed due to excessive cracking of the welds and sagging of the platform (SOLAS Ch. II-1, Regulation 3-1).
Engineering › Fuel Oil Storage/Transfer System › Flange
Issued 23 July 2004
Resolved
Vessel is to renew the leaking gasket for the emergency generator fuel tank - bottom access plate (SOLAS Chapter II-1, Regulation 43.3.1.1.
Lifesaving › Launching Appliances
Issued 2 June 2004
Resolved
Falls on Starboard Life Boat were not long enough for the survival craft to reach the water, to be correct prior to departing the port. IAW SOLAS 2001 (Consolidated) Chapter III Regulation 16.6. LEGACY COMPONENT DESC: Falls
Accommodation/Occupational Safety › Occupational Safety
Issued 10 December 2003
Resolved
WASHER WITH ELECTRICAL CORD PLACED IN WASH ROOM. THIS CREATES A RISK DUE TO THE CONDUCTIVITY WHICH MAY EXIST. SOLAS 74/78 CH-II/REG 45/1.2 . CORRECT PRIOR TO DEPARTURE AND PROVIDE CLASS REPORT LEGACY COMPONENT DESC: Portable Electric Equipment/Appliances
Fire Fighting › Combustible Materials
Issued 10 December 2003
Resolved
5 GALLON PAIL HALF FULL WITH OIL IN FRONT OF #3 S/S GENERATOR. SOLAS 74/78 CHII-1, REG 26. CORRECT PRIOR TO DEPARTURE AND PROVIDE CLASS REPORT.
Fire Fighting › Combustible Materials
Issued 10 December 2003
Resolved
NUMEROUS 5 GALLON PAILS FILLED WITH OILY RAGS THROUGHOUT ENGINE ROOM. SOLAS 74/78, CH II-1, REG 26. CORRECT PRIOR TO DEPARTURE AND PROVIDE CLASS REPORT.
Fire Fighting › Combustible Materials
Issued 10 December 2003
Resolved
55 GAL DRUM 1/2 FULL OF HYDRAULIC OIL WITH WOODEN AND PAPER COVER IN AFTER STEERING. SOLAS 74/78, CH II-1, REG 26. CORRECT PRIOR TO DEPARTURE AND PROVIDE CLASS REPORT.
Accommodation/Occupational Safety › Occupational Safety
Issued 10 December 2003
Resolved
HYDRAULIC OIL ON DECK IN AFTER STEERING, AFT OF THE BULKHEAD, STARBOARD SIDE. SOLAS 74/78 CH II-1, REG 26. CORRECT PRIOR TO DEPARTURE AND PROVIDE CLASS REPORT. LEGACY COMPONENT DESC: Slip Trip and Fall Hazard
Fire Fighting › Combustible Materials
Issued 10 December 2003
Resolved
10/5 GALLON PAINT CANS (50 GALLONS) SITTING ON THE DECK IN FOC'SLE. SOLAS 74/78 CHII-2, REG 18.7. CORRECT PRIOR TO DEPARTURE AND PROVIDE CLASS REPORT LEGACY COMPONENT DESC: Paints/Varnishes/Other Finishes
Accommodation/Occupational Safety › Medical/First Aid
Issued 10 December 2003
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Lifesaving › Embarkation Appliances/Stations
Issued 10 December 2003
Resolved
STARBOARD LIFEBOAT EMBARKATION GRATING IS WASTED/BROKEN. THE WELDING HAS RUSTED THROUGH, CREATING A SLIP, TRIP, AND FALL HAZARD. ( ILO/147). CORRECT PRIOR TO DEPARTURE AND PROVIDE CLASS REPORT.
LEGACY COMPONENT DESC: GRATING
Accommodation/Occupational Safety › Washroom/Toilet
Issued 10 December 2003
Resolved
A FLEXIBLE HOSE FROMTHE DECK ABOVE IS BEING USED FOR DRAINAGE INTO THE SHOWER BASIN. (ILO 147). CORRECT PRIOR TO DEPARTURE AND PROVIDE CLASS REPORT. LEGACY COMPONENT DESC: Shower/Bathtub
Accommodation/Occupational Safety › Washroom/Toilet
Issued 10 December 2003
Resolved
INADEQUATE OPERATIONAL TOILETS FOR THE AMOUNT OF CREW ON-BOARD. 06 FUNCTIONAL TOILETS ARE REQUIRED ON BOARD FOR A VESSEL OF THIS SIZE. ( ILO 147). CORRECT PRIOR TO DEPARTURE AND PROVIDE CLASS REPORT LEGACY COMPONENT DESC: Toilet
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 10 December 2003
Resolved
VESSEL'S HIGH PRESSURE CO2 FIRE FIGHTING SYSTEM IS MISSING SERVICING CERTIFICATES. SOLAS 74/78, CHII-1, REG 26. LEGACY COMPONENT DESC: SERVICING CERTIFICATES
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 10 December 2003
Resolved
FIRE EXTINGUISHER IN PORTSIDE AFT FOC'SLE IMPROPERLY MOUNTED. ( SOLAS 74/78, CH II-1, REG 26). CORRECT PRIOR TO DEPARTURE AND PROVIDE CLASS REPORT. LEGACY COMPONENT DESC: Mounting Bracket
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 10 December 2003
Resolved
FIRE EXTINGUISHER IN DECK HOUSE AFT OF #1 CARGO HOLD IMPROPERLY MOUNTED ( UNABLE TO RELEASE FROM MOUNTING BRACKET. SOLAS 74/78, CH II-1, REG 26 LEGACY COMPONENT DESC: Mounting Bracket
Accommodation/Occupational Safety › Messroom
Issued 10 December 2003
Resolved
GENERAL CLEANLINESS IN GALLY IS UNSATISFACTORY. (ILO/147). CORRECT PRIOR TO DEPARTURE AND PROVIDE CLASS REPORT. LEGACY COMPONENT DESC: GENERAL CLEANLINESS
Electrical › Electric Generation Source (service)
Issued 10 December 2003
Resolved
ALL 3 OF VESSEL'S SHIP SERVICE GENERATORS HAVE FUEL AND LUBE OIL IN DRIP TRAYS UNDER THE DELIVERY PUMPS ON EACH GENERATOR, A VIOLATION OF SOLAS 74/78 CH II-1 REG 26. VESSEL'S CLASS TO ADDRESS PRIOR TO VESSEL DEPARTURE. LEGACY COMPONENT DESC: Generator
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 10 December 2003
Resolved
External auidt required due to numerous defs involving maintenance, documentation, and overall implementation of a SMS.
Fire Fighting › Firemans Outfit
Issued 28 May 2003
Resolved
Crewman showed up to location opf fire with empty oxygen tank. Crewman made approach and open door to fire without protective gear. There was no formal muster conducted. LEGACY COMPONENT DESC: Self-Contained Breathing Apparatus
Deck/Cargo › Cargo Stowage
Issued 28 May 2003
Resolved
The tanks were lashed with 1/2 line to angle iron. LEGACY COMPONENT DESC: Oxygen & acetylene tanks
Fire Fighting › Structural Fire Protection - General
Issued 28 May 2003
Resolved
4 of 5 stairwell fire doors improperly adjusted and did not self close. LEGACY COMPONENT DESC: Superstructure Construction
Fire Fighting › Combustible Materials
Issued 28 May 2003
Resolved
Improper storage of open paint cans. Paint, brushes, and thinners in open cans. Rags and other assorted clutter stored on floor making it impossible to make entry into space. Fumes very strong in spite of ventilation. LEGACY COMPONENT DESC: Paints/Varnishes/Other Finishes
Lifesaving
Issued 24 April 2000
Resolved
OPEN CANS OF PAINT AND THINNER IN PAINT LOCKER, GENERALLY UNSAFE. _x001C_ SOLAS 74/78 CHAP. I REG. 11(a).
Fire Fighting
Issued 24 April 2000
Resolved
ALL FIRE DOORS WERE NOT SELF CLOSING AND SELF SEALING. _x001C_ SOLAS 74 81 AMMEND. CHAP II-II REG 30.
Fire Fighting
Issued 24 April 2000
Resolved
ENGINE ROOM ESCAPE FIRE DOOR NEEDS SEAL INSTALLED. _x001C_ SOLAS 74/78 81 AMMEND. CHAP. II-II REG. 30.
Fire Fighting
Issued 24 April 2000
Resolved
03 FIRE HOSES WERE DRY-ROTTED AND WERE LEAKING HEAVILY. _x001C_ SOLAS 74/78 CHAP. II-II REG. 21.
Construction/Loadline
Issued 24 April 2000
Resolved
LOADLINE MARKINGS NOT IN CONTRASTING COLORS. _x001C_ ICLL 66 REGULATION CHAP. I REG 8.
Lifesaving
Issued 24 April 2000
Resolved
LIFERING ON BRIDGE NOT SELF-ACTIVATED. NO MANUAL OR AUTOMATIC RELEASE. _x001C_ SOLAS 74 UNAMENDED CHAP III REG. 21(g).
Fire Fighting
Issued 14 August 1998
Resolved
MINOR LEAK IN FIREMAIN PIPE FLANGE IN WAY OF NUMBER THREE CARGO HOLD STARBOARD SIDE IN VIOLATION OF SOLAS 74 II-2/21. CORRECT PRIOR TO NEXT U.S.PORT.
Lifesaving
Issued 3 February 1997
Resolved
GENERAL CONDITION OF BOTH LIFEBOAT CARRIAGES ONBOARD WERE WASTED. HAVE CLASS MAKE COMMENT.
Fire Fighting
Issued 18 November 1995
Resolved
PRIOR TO DEPARTING THE PORT OF TAMPA, REPLACE 03 FIRE HOSES THAT FAILED DURING TEST OF EM. FIRE PUMP._x001C_ _x001C_ _x001C_
Lifesaving
Issued 21 August 1995
Resolved
A DEFICIENCY UNDER SOLAS CH-III REG-31 IN THAT THE VESSEL FAILED TO HAVE ALL THE REQUIRED LIFERING'S MOUNTED WHILE IN U.S. WATERS. CORRECT PRIOR TONEXT U.S PORT._x001C_ _x001C_
Navigation
Issued 19 March 1991
Resolved
A VIO OF 33 CFR 164.30 IN THAT THE U.S. COAST PILOT VOL. 3 USED BY THE VSL WAS NOT CORRECTED TO NTM 45/90 WHICH WAS REASONABLY AVAILABLE AND CONTAINEDCORRECTIONS THAT WERE APPLICABLE TO THE VSL'S ROUTE FROM CAPE HENLOPEN DE. TO CAMDEN, N.J. THERE WAS NO ACCEPTABLE FOREIGN EQUIVALENT O/B.
Navigation
Issued 19 March 1991
Resolved
A VIO OF 33 CFR 164.30 IN THAT THE USCG LIGHT LIST VOL. 2 USED BY THE VSL WAS NOT CORRECTED TO NTM 43/90 WHICH WAS REASONABLY AVAILABLE AND CONTAINEDCORRECTIONS THAT WERE APPLICABLE TO THE VSL'S ROUTE FROM CAPE HENLOPEN DE. TO CAMDEN, N.J.
Navigation
Issued 19 February 1991
Resolved
A VIO OF 33 CFR 164.30 IN THAT THE USCG LIGHT LIST VOL. 2 USED BY THE VSL WAS NOT CORRECTED TO NTM 43/90 WHICH WAS REASONABLY AVAILABLE AND CONTAINEDCORRECTIONS THAT WERE APPLICABLE TO THE VSL'S ROUTE FROM CAPE HENLOPEN TO CAMDEN, N.J._x001C_
Navigation
Issued 19 February 1991
Resolved
A VIO OF 33 CFR 164.30 IN THAT THE U.S. COAST PILOT VOL. 3 USED BY THE VSL WAS NOT CORRECTED TO NTM 45/90 WHICH WAS REASONABLY AVAILABLE AND CONTAINEDCORRECTIONS THAT WERE APPLICABLE TO THE VSL'S ROUTE FROM CAPE HENLOPEN TO CAMDEN, N.J. THERE WAS NO FOREIGN EQUIVALENT O/B.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.